How to prevent pc ups from shutting down with no load --- Its About Everything
HTML-код
- Опубликовано: 19 окт 2024
- Hello every one
Welcome to another episode of
Its About Everything
/ itsabouteverything01
This episode is the details analysis of the the problems that we have with our pc ups.
You see this ups's are made in such a way that they can only be used with pc's only and if you try to use it with some other appliances then they either turns off or shows over load.
In this video i am modifying a frontech ups so that it can run at a least amount of load , such as 5 or 10 watts for running dsl modems or wifi routers.
The actual solution is replacing a resistance that tell the controller when to turn off and bypassing it keeps the ups on at no load unlike before when it used to turn off when there was no load.
I also have another video about the detail repair of this ups you can click the link here to see the video.
• Frontech jil power 600...
I hope you like this video
if so then don't forget to subscribe to my channel
and hit the like button as well
as share this video to you friends.
As always this video was not sponsored by any product shown used or name mentioned.
Thanks a lot for watching this video
i'll see you soon.
Is there any other alternative method other than this?? Please reply soon!!
Yes there is an alternative way i will make a video soon.
Allow me to pin your comment so that others can see.
Thank you sir!! waiting for your new update!!!!
Sir, please make a video on it soon!!
sir atne din RUclips pe search kar kar ke ajj jake sehi video mila ....
Thank You Sir...🙏🙏🙏
I have tested what this gentle man has suggested for the Frontech UPS with iBall UPS. I want to give the good news that it works ! Very good ! Thank you for the tip and help.
However, the iBall UPS board and Frontech are not exactly same but similar. I was able to locate the said SMD 620 Ohm resistor. I connected two wires as suggested and connected a 1.2 K resistor. I suppose the calculations for the iBall UPS are a bit different. So I didn't use the suggested 56 K resistor but used 1.2 K. So Here is what I think works for iBall :
1. With 620 Ohm min load required is about 120 Watt
2. With 1.2 K minimum load required is abut 60 Watt
3. With 2.2 K minimum load required is about 30 watt
Earlier connecting only a laptop to the UPS would cause it shut down after 30 secs. Now with the change of resistor to 1.2 K I can run a laptop and it works fine.
Again thank you so much !
Ik this is 5 months old but can you remember why resistor did you change on the iball ups like no (R14)?
I actually removed one through hole resistor (1.3k ohm) and the ups works fine now but after watching this video i found the 620ohm resistor what should i do? Because after removing that resistor (not the smd 620ohm) now my ups outputs only 160V AC?
I have ver old model UPS may be around 2004 model made by Powetech. There is no such resister available there. Can you pls help me. I just want to use it for router.
hi, can you please tell me which resister to be removed to disable no load cut off in APC ES 500 ups
Can we connect a variable resistance I.e. preset of appropriate value to change the minimum/maximum load requirement?
If it's possible , then It will be more useful in situations , we'll not have to use multiple ups units as per their different minimum load requirement.
Yes you can. But also think of this :
1. You have to use a pot meter or variable resister. Where will you mount them ? They will easily catch dust if kept outside.
2. For different loads you have to keep adjusting it. This is tedious to do.
So if you want to use it for variable loads use a multi-position switch, with preset resistors connected.
mere pas same board ha isme 0 to 100w out ke liye konsa value chaiye? aur isme low battry voltage ko bypass kese kare? 11.50v par off hojata ha. me bms battry use karna chata hu
What about the wires out and can i get 10-100 watt on the board fitted already on the back side of the ups?
बहुत अच्छा वीडियो था सर और एक दूसरा वीडियो बनाए सर अलक यूपीएस कंपनी का सेम टू सेम वैसा ही हमारे पास अलग कंपनी का यूपीएस है. जरूर रिप्लाई देना और वीडियो बनाओ.
I have prolink pro 700. same board. which registor use for 1w to 150/200w?
Good tiching karte hai 👌👍👌👌👌👍👌
Can I use 71k resistance
can we convert this into solar?
Sir can i remove r19 resistor for long time run...
Thanks a lot for providing a valuable information.
I have a ups that i replaced the four transistors & replaced busted plate fuse. Now, when i plug the battery, the spark is not normal and when i plug the power cord with the battery connected, the transistor in one of the heat sinks is blown again. What could be the cause? Can you help me?
Yes..... Thanks for uploading this video......it's essential and also informative & very very helpful....
Hello Brother, I need load variance in between 5w to 50w. what resistor need to attach. Please help.
If we can solder 100k ohms then okey or not for only home theater.... I want to install UPS in my car. XUV500....please tell
Bhai plz make a video to disable ups from shot down on low voltage so that ups will not turn off when battery voltage go below 10 voltage
I want to run my laptop and a router and a Fan for example. 150W load how much resistance needed?
Sir ji mujhe iski kit board chahiye kya milega mujhe.. plz help me
Well said man. Thanks
I tried the same in intex ups..
But it did not work.. could u suggest what should i do.. and its not easy tp find tge resitor responsible for the change in load. ..please help me out with this..
I have frontec ups pls.make a video on how to remove autocut and no load detector circuit in frontec ups so that uninterrupted 220 volt current can flow contineously. I need it for some projects pls.
Same information I would like to know please help and reply must
Reply please
I have tested what this gentle man has suggested for the Frontech UPS with iBall UPS. I want to give the good news that it works ! Very good ! Thank you for the tip and help.
However, the iBall UPS board and Frontech are not exactly same but similar. I was able to locate the said SMD 620 Ohm resistor. I connected two wires as suggested and connected a 1.2 K resistor. I suppose the calculations for the iBall UPS are a bit different. So I didn't use the suggested 56 K resistor but used 1.2 K. So Here is what I think works for iBall :
1. With 620 Ohm min load required is about 120 Watt
2. With 1.2 K minimum load required is abut 60 Watt
3. With 2.2 K minimum load required is about 30 watt
Earlier connecting only a laptop to the UPS would cause it shut down after 30 secs. Now with the change of resistor to 1.2 K I can run a laptop and it works fine.
Again thank you so much !
@@mathewthomas597 thanks for this info, it'll be very useful for me. I also have an Iball ups.
Thanx dear ❤️❤️❤️👍👍
bhai mera naya UPS 1 saal huya sirf.. itna din chal raha tha aaj se kaam nahi kar raha hai.. mere paas ips hai toh ups battery sirf 1 sec ke liye chalta tha toh kaam karna kyu bandh huya bata sakte hai plz..
Bhi intex ups mai konsa resistance replace karna hai
Bro zebronic u725 achanak chalte chalte off hokar on ho jata hai kya problem ho sakta hai please btao bhaiya kya kare.
I have same pcb board.I remove the 620 ohm resistor but unfortunately the connection there be desolder fully and l am not able to connect another value resistor.what should I do sir!! Please reply sir soon with solution!!
Sir i want to use it from 10 watt to 220 watt can you tell me how much resistance i needed in that case .??please tell me
Hi, i have a smililar but oposite problem.
My ups shuts down without reaching its full load.
I hear a relay and after a second it shutsdown. only at 200W being rated at 600W. Any idea on the problem?
I think It happens when the battery gets old and looses its capacity.
@@ItsAboutEverything01 The thing is that i´ve switched to a LI-ON battery that stays well above 12V so thats not the issue.
It has the power of the battery it will just shutdown
@@ItsAboutEverything01 Well i know its not that, because i´ve putted a new 39Ah lion battery connected to it. It stays above 12V easely it doesnt trigger the battery protection.
3S or 4S Li-ion battery. Whats the voltage of the pack.
@@ItsAboutEverything01 3S LI-ION batterys to match the acid that was there
Sir mere pas ak power guerd ups hay Mera ups 2-3 min chalnaka bad dc mode may shift ho Jay ,1,2 second bad phar ac mode shift ho Jay,may iska open Kare,all components fresh,not dry sold,wire connector ok,but phirvi same problem.
Very good information sir.....nice video
Hello sir Aik chota sa ups hay andar battery b fit hay usmay . Kavya chala raha hay lekn laptop charger lgatay hee trip/off ho jata hay.
sir 82k se kitane vaat chalae ja sakate hain? Please Sir reply
Sir. What is this resistance code in Ups PCB...??
56k is not available in our area .. alternative resistor batao.. please
Bro mere pass ye hi model hai or mere ko 10 watt se jitna load ye leta hai
Utna hi load ke liy konsa rasistor lagega
Aapka bohoot dhanyavad.
My router is 9 volt 0.6 amp and after power cut it is on hardly 5 to 6 min..and my ups battery is 12v 7 Ah. Plzz suggest what kind of resistance I should use.
Plzz sir..and my battery is new
Cpu backup achha hay
Leken monitor back up nehi hay
Problem Kaya bata digiye please
23 watt LED k lye kitna value ka resistance laga na chyee.??
Bhai mere ups ke output ko galtise 230V AC supply se connect kardiya so ab ups ka buzzer calu band ho raha he or supply bhi chalu band ho raha he or andar relay bhi on off ho rahe he kya hogaya hoga usme?
When I run pc then it's fine. But when I run same wattage of fan ,light then after 5min relay is cut off. Solution?
I need a little help, I also have the same model, a resistance has gone short, (R13, gray resister , orange orange gold gold gray) the color code is atrandum no one is able to find its value, can u pls check its value through multimeter & kindly tell me, I can send u the image also.
Water guns ki video chahie Sar ji❤❤
But i need 0 to 200 watts - what resistor i have to put? Pls reply gee
I have Iball nirantar 622 ups, I cant able to identify the resistor. can you please help me to find!
I have tested what this gentle man has suggested for the Frontech UPS with iBall UPS. I want to give the good news that it works ! Very good ! Thank you for the tip and help.
However, the iBall UPS board and Frontech are not exactly same but similar. I was able to locate the said SMD 620 Ohm resistor. I connected two wires as suggested and connected a 1.2 K resistor. I suppose the calculations for the iBall UPS are a bit different. So I didn't use the suggested 56 K resistor but used 1.2 K. So Here is what I think works for iBall :
1. With 620 Ohm min load required is about 120 Watt
2. With 1.2 K minimum load required is abut 60 Watt
3. With 2.2 K minimum load required is about 30 watt
Earlier connecting only a laptop to the UPS would cause it shut down after 30 secs. Now with the change of resistor to 1.2 K I can run a laptop and it works fine.
Again thank you so much !
I have same ups plz say if i run constantly by using battery all time what can i do
Mere pas champion ups 800 hai. Kaise modify karu. 80watt ke upar hi chalta hai. Mujhe 60 Watt par chalna hai. I can't identify this resistor. Please help me.
Bhai companies low load auto off function dalte kyon hai?
Hii bro good video👍
Mera same ups hai jo flickering karta hai bulb ya tubelight pe aisa hota hai ya koi fault hai halka vibrations ho raha aisa jalta hai bulb
Thank you bro.. Am using NUMERIC Digital 600 Ex-C model 150k not work for me. Am using 300k instead of 150k.
hlw bro mere paas bhi same he pliz help kar do
Hi brother I have also same model, is it work for you ? and till what load it will take
@@khagendra6332 speak Hindi
Yes it worked for me I put 330kohm register it work , I put a two way switch , so that I can run heavy load and no load, 150,180 kohm not working ,put 300 or more than 300kohm it will work
Why dont you show the connection after removing the insulation tape used on the pcb?
10watt se 300watt output nikalne ka batao Bhai mere pass hai UPS
Bro ups battery totally not lose energy before sutdown so how to make till last enrgy used ups reply
Mere pas Supercomp company ka ek pirana UPS hai. Maine bohotot kosis karli but phir bhi UPS automatically off ho raha hai... Please help me🙏🏻.. bohot paresan ho gaya hu mai.. thodi madat mil jati to bari meherbani hoti..
Cann i connect 12v 1amp router
??
Sir mere pass same circuit h.. Pr jb me on krta hu.. To 100 watt ka bulb blink krte hi cut off ho jata h or red light jlne lgti h? Solution btay please
How to use zebronics ups .. circuit is quite different
Thanks for the tip idol... Ill try this.
Sir mene bhi apke jese hi Kya but vo ose nikalte hi band ho gya or abhi on bhi nhi ho rha Kya koe solution hai sir ho to please btao
Mujhe PC bhi chalana hai aur power na hone par 9 watt ka led bulb ya mobile charger bhi chalana hai. to kya karna hoga..
Ya ups ka name kya ha or iska now pch milaga q ku mera ups ka motherboard jal gya ha
I cange it with 56 k, normal res. But i cant start computer, showing red light in main power but give backup frm battery with same load?
Can you help me? How can I change??
I have the same problem ,Raju bro are you fix it ?
mine Worked with 200k ohm resistor for wifi router. Thanks
@Pritam Halder around 50k or 100 k
@Pritam Halder try 68k
Thanks
Bhai kitna backup deta hai same mere saath
40 second bhai
my computer automatically Restart when main power cuts off..
ye ups ka problem hai kya????
Variable resistance lgaya ja sakta hai 159k .....??
Yes
Matlab 150k ka volume control 620 ohm ke registance ke sath chalega...plz guide me...
Registance isliye kyunki zero registance nhi kar sakta
Direct bhi kr sakte h kya isko bina registrance k
When I plug my computer ups the current of the house trip what is the problem
Sir my new zebronice ups no backup. Salussion tell me please
Hi sar I am using same board how to fix auto cut off
Load or no load backup mode turns off after 15 seconds.why.pkease help.
Same problem in my ups
Salussion tell me please
Hello bhai mujge aapki help chahiye
Sir pls pls pls pls pls hlp. Mera ups automatically band chalu hota hai kabhi 5 min chalata hai kabhi 7 kabhi 2. Isiliye maina NAYA battery liye phir v same problem hai pls pls pls hlp sir ..i m in a great trouble. Koi dukan dar nhi bana pa raha
Please specify correctly where the resistor is connected. I dont understand you. If any other mathode to solve this problem
I have a serious problem, when ever i run my pc, when power cuts , the ups is unable to act quickly and my whole system gets off in 1 sec. After the whole system gets off then it again starts with ups battery with beeping sound.
Is it beeping every second after it starts again or beeping every 10 second.
@@ItsAboutEverything01 every 10 sec while restarting. And sometimes it beeps every second while running the pc also. It just doesnt act in case of a power cut.. the whole pc shuts down immediately when power cut, its like i have no ups
Me too I lost a computer smps and 5 wifis
Sir please additional lagaya Gaya ओहम resistance dikhaiye
Bro I have emerge ups same problem..but there is no 620 smd resister.
It's 6200 means 620 ohm
Sir iska circuit board Kha milega
56k register not working taking any loan, just beeping continuously and turning off
Luminous 600va ka dikhana plz no load sutdown
Ye board milti hai market me
Aap Nahin resistant ka number Nahin bataya new circuit Koi Piche micro Integrated circuit Piche Hota Hai micro IC usmein kaun sa register number rahega aap reply dijiye na aajkal ke Microtek company ke Aate Hain UPS board usmein kaun sa rahega register number kaun sa Rahega aur kaise cut off Karen
Kit kaise milega iska Nam batao please
Sir 56k ka restor to bata diya magar wattage bhi to batao
How ..to .use ..your ..tecnick in zebornick board
I have tested what this gentle man has suggested for the Frontech UPS with iBall UPS. I want to give the good news that it works ! Very good ! Thank you for the tip and help.
However, the iBall UPS board and Frontech are not exactly same but similar. I was able to locate the said SMD 620 Ohm resistor. I connected two wires as suggested and connected a 1.2 K resistor. I suppose the calculations for the iBall UPS are a bit different. So I didn't use the suggested 56 K resistor but used 1.2 K. So Here is what I think works for iBall :
1. With 620 Ohm min load required is about 120 Watt
2. With 1.2 K minimum load required is abut 60 Watt
3. With 2.2 K minimum load required is about 30 watt
Earlier connecting only a laptop to the UPS would cause it shut down after 30 secs. Now with the change of resistor to 1.2 K I can run a laptop and it works fine.
Again thank you so much !
More detils plz ?
If direct the relay then it will keep on
Yes, that can be done too. I didn't thought of that until now. Thanks for sharing.
@@ItsAboutEverything01 brother can you make one vedio on that cos i too much disappointing from shutdown even battery is charge any other way to bypass the ic ?
how to direct the relay?
@@almasud2011 just one relay you on and one off in opposite directions normally Ac relay on and for dc is of you have to of the Ac really and on the dc it called AC bypass just thats it
agar realy ko nikal de to chalega ... ?
i ball ka ups ha to kaya karu
Microtek JM SW 4000 bina load k auto off ho jata hai mujhe ye system band karna h isme
Hmara ups chalu hai us pr hamne badi battery lagaai or us pr Ac karent ata hai
Pujan kumar singdaha se u.p.s मे उलटा बैटरी मे लगा ते तब क्या होगा
My ups is not working .
Are bhai tep laga diya hai kaise pata chalaga
Bhai WiFi rautor jitni der chalta hai
Yeah to bta de mere main zener diodes nhi h
Instead of connecting to ups u could have got power bank