The same problem is in my APC BACK UPS ES 500( bought in yr 2005 & working fine). I want to use it as back-up for 28w BLDC ceiling fan. Any idea to disable?
One doubt after removing 01B, should I leave the terminals open or do we have to connect them. In the video it looks like it's open but 3:55 You said Normally Connected
Hello dear friend, I have a UPS Blazer 1.4 KVA, after working for a few days, the battery lights are on, as well as the fault lights. The output is cut off. What is the problem? Can you help me? Thank you.
I have watched your video on UPS and it is very useful. We are having Vguard Slender 600 ups. In this how to disable no load shutdown. Any tips?. Thanks
Bro i am using luminous duo pc inverter while on automatically cut off in 2min. I watch your video but I didn't got any idea with this board Can you help what resister I have to remove Please help .. And your explanation is super
@@Panneer in ups, it is not charging bro. First when I on the ups, it was only in battery mode (even when connected to mains), then one day again when I switched on , it showed red light, then completely got shutdown, now not charging. What to do?
Thanks Bro, I searched for the same problem, but no one has a solution to fix it. This helps. Thanks a lot bro..
This is great. Thank you very much. Really helped this video to fix my prolink UPS with few changes. 🙂
Welcome 🤗
Help me please, I have aslo PROLINK ups, auto shutdown after 1min run.
Thanks bro
It worked good, tried with Intex ups removed r19 resistor
It is a greate headache problem which is solved/fixed by you. Thank you
Thank you for your support 😘
did you try it
Thank you bro it's really helpful it's worked actually keep doing bro
Thank you 💞
The same problem is in my APC BACK UPS ES 500( bought in yr 2005 & working fine). I want to use it as back-up for 28w BLDC ceiling fan. Any idea to disable?
There is no option to repair this type ups sir.
Put the load to 100w it will help you
Thanks bro, really worked🙏
very very useful
Bro intha ups la led 9w evalo neram erium solunga bro vetla kolantha iruku ipoo adikadi powercut aguthu athuku use panikaramari 1hr kachu light eriumah CFL inverter mathiri pls sollunga
Approximately 2 to 3 hrs
One doubt after removing 01B, should I leave the terminals open or do we have to connect them.
In the video it looks like it's open but
3:55 You said Normally Connected
no need to connect
Brother I don't find r19 resistor
Thanks
Oru doubt inbuilt battery remove pannitu 28ah battery connect panni battery ya solar la charge pannalaama
no bro, board poidum
Hello dear friend, I have a UPS Blazer 1.4 KVA, after working for a few days, the battery lights are on, as well as the fault lights. The output is cut off. What is the problem? Can you help me? Thank you.
Super bro
Thank you ❤️
Would appreciate the vid if there are ang english sub title. Thanks
After cutting r19 also same issues
Sir i have same ups but old version and circuit also different and bigger type Please tell me how to off auto power saving mode
Circuit diagram needed
GOOD
Bro ennoda ups idhe model thaa but recent ah current cut aana odane off aagirudhu, power switch ah off pannale ups off aagurudhu solution sollunga
I dont understand. My UPS is APC 650VA. I need to disable the auto shutdown. What should i do. Thanks
Numeric ups 600ex la r19 resistor illa bro. Vera epdi panrathu solunga
Mfg year
2010 bro
Athula power cut off option erukkathu bro
Vera option illaya bro
Ella bro.
Antha board la appadi oru system erukkarathukku option erukkathu
Hi Selvam, I have cut the R19 but same issue...Can you guid me please...I use Frontier UPS
R19
@tanpuia laltanpuia see that video
Thanks anna ❣️🤗
Bro anaku current cut aana le pc yum off aagidhu yen🥺🥺
Ups model bro
Bro zebrosonics ups la R19 resister ah remove panniten but still after 60sec cutoff aaguthu bro enna pandrathu pls help me bro....
bro this only for numeric
I need solutions for apc 325va?
Anna enaku battery la 12v iruku but 45 seconds la cut off aaiduchi ena pandrathu
ups model
Numeric digital 600 ex
Sir, this type of ups are pure sine wave or modified sine wave?...pls revert...
@@Panneer thank you
Modified sinewave
thanks u bro
Welcome
Hi bro.. how can we disable it in ZEBRONICS ZEB-U725 U725 UPS?
PCB board ah check pannanum bro
Good, keep it up
Thanku bro usefull
I have one old model numaric ups, how to solve auto cutoff problems
Only new model
Numeric brand use panren athu board different aa irukku athula yeppadi power save mode disable panrathu athula r19 illa
entha board numeric odathu than sir
@@Panneer s sir numeric than
@@Panneer unga number iruntha sollunga whatsapp la board photosend panren
psk9791@gmail.com send me
@@Panneer unga mail ku send panni irukken
hi bro can u check which one should i remove in apc ups 625..
bx625ci-ms
No boards diagram available bro
can u check it.ill send u a picture of the board
numeric 600va ups EB 230v power off condition la battery backup la run but how to stop alarm sound pls help me
remove the speaker
👍
Bro na indha beep sound varakudathu nu adha remove pannen adhuku aprom ups work aagamatingudhu
intha ups legrand campany ya
Numeric 600ex
Sir. Model no ibell ups. 630
Ok send me board pictures .
psk9791@gmail.com
proview 600 ups, old type ups didn't seen any psm table, pls help
Old type is not having r19
Bro nice tip, but I am not sure how to disconnect this in my ups
using soldering iron
Ac supply la ups relay fluctuations aguthu
If battery low power will shutdown faster bro
@@Panneer i connected new battery and switch on its fluctuate
I removed that resistor also
@@TechnicalArt91 same model UPS ?
Yes its numeric
Ji apc ups eappadi panradu sollunga please
find psm modules
Apadinna eanna
For power saving unit control circuit
Adu eappadi change panradu
First you find that sir
Bro Kstar 650va ups, How to solve Auto Cutoff problem??
Need Circuit diagram bro
What is Circuit diagram bro
Please help me.
My ups circuit psm no. R19 same to you and have a 01B.
It's service manual for service engineer. That's is Circuit diagram
Thanks bro I got it. My problem solve. 01B remove and solve my problem. Thank you bro. Love you💝💝💝
Ups brand name?
Numeric
Bro enaku per day ku one time aachum UPS restart agudhu bro... I didnt know why?
Same thing
I have watched your video on UPS and it is very useful. We are having Vguard Slender 600 ups. In this how to disable no load shutdown. Any tips?. Thanks
Same thing.
Find PSU mode companent
you can either connect or not since it will go to" no psw "terminal. or direct. both means the same
Hi bro, pls tell me a solution for my ups input problem, power input indicate pannala backup dan varudhu, green led illa orange led dhan eriyudhu.
I can't understand the problem
@@Panneer power connect aagala, but ups battery out put mattum dhan varudhu
@@ultimatephotography7118 check input relays
@@Panneer single phase dhan irukku veetla so adanal problem irukkuma
600va ups are working only single phase
Bro vguard ups la eppadi pannanum
Same.
Find the PSU mode resistor
Bro i am using luminous duo pc inverter while on automatically cut off in 2min.
I watch your video but I didn't got any idea with this board
Can you help what resister I have to remove
Please help ..
And your explanation is super
Every brands have different types.
Send me pictures to my email
psk9791@gmail.com
I already sent bro
how about apollo blast 600VA? is it R19 too?
No.
Need board schematics
@@Panneer ok, will email you the picture. thank you
Bro plz tell what is the resistor colour code
No color code for that resistor
@@Panneer it's 81Ω
Enoda system edhunala restart agudhune therla bro whether its due to UPS, PSU, or something else
@@Panneer psu is brand new. Only 4-6 months old and its gaming psu. are you sure its PSU FAULT?
@@Panneer i have done adequate steps to stop auto restart in system by disabling auto restart bro
Ups la OPPO A9 phone charger poda finger print la earth varuthu. Normal current la earth varala ean intha broblem
UPS ku ground properah varathu bro check pannunga
@@Panneer epdi check panrathu
Ground pin la indicator vachu parunga
Ups ku earth compy ethum kudukanuma
UPS ku input varathula kudakkanum
My problem is language barrier.
Bro one help please
What
@@Panneer in ups, it is not charging bro. First when I on the ups, it was only in battery mode (even when connected to mains), then one day again when I switched on , it showed red light, then completely got shutdown, now not charging. What to do?
Bro all type ups system this method
no
R19 is not 01B , It's SMD code 810 means 81Ω
I told only r19 resistor number .
I not tell any resistance value
Psm mode இல்லாத யு பி எஸ் ஐ எப்படி மாற்றுவது
Automatic cut off aguthu
@@vinotht9948 bro ahtha remove panna charge yaruma
@@Cwc_2.0 thereyala bro
Akum bro
Numeric 600Ex v auto power cut solution
New or old type
Theriyala but led light 1 than irukku
Mcb border la diagram illa
@@Panneer ups button ha aluththi pidicha on aguthu work aguthu vittuta udanea off aeduthu
Digital 600ex v
GRN meaning
Ground
V gard also same method
yes
how to disable auto shut-down timer on APC BACK-UPS ES 500?
Send board pictures to my email.
psk9791@gmail.com
Sir, Same type ups, after connecting load, output off.
Without load it is working.
What is the problem, bro
battery
Hiii bro please hel me i really need help
What type help
@@Panneer i have an extra ups bro its is double sided pcb i means it have smd transistor so how do i foind the right transistor to remove
@@Panneer plss halp me bro i really need help 🙏🙏🙏🙏🙏
Check the name if PCB board is different model ask UPS brand
@@Panneer bro its umax brand
And r19 prrr smd resistor hai bhai colour wala nhi
Apna no de do mera ups kharab hai
Hindi me bataaen please
hhho
Bro, ithu theriyama 2 times battery change pannitten.
OMG
Bro all type ups system this method
No