Lekin success nhi hai 5min.baad cutoff ho ja rha r19 resistance ko nikalne ke baad v Aapka video success nhi hai qki maine ye prayog kar liya 5min.cutoff ho ja rha hai
thank you Bhai 😍 Bhai moi tu apunar channel 1k subscribers r porai follow kori asu . Bhaut bhal lage dei apunar video Bilak😍. Moi nijeu eta channel khulisu apunar pora inspire hoi. Ei link tut ebar click kori dibo please ruclips.net/channel/UC_8LddpYA_GkDXlS5uRe-1Q
Ye ups khas pc ke liye design hai aur ye kit nya advance smart mode me aata hai agar galti se hum pc shutdown karke ise band na kre to automatically ye ups band ho jata hai taki hmara bil km aaye ye advance future isme hai aur isse pahle ke ups Jo lambi kit ka tha usme ye advance future nhi hai isliye woh purane ups se hum light ya mobail charge kr skte hai lekin nye adwance walese nhi bhai ne nye ups me jugad kr diya thanks mere pas dono ups hai isliye mujhe ye bat smj aayi aur jo pc hardware repair ka kam krte hai unhe bhi pata hogi shayad
Hi you're always excellent. Your video are all informative. Please let me know is it possible to increase mosfets add extra mosfet in this ups. please reply. Please also let me know is it possible to add extra transformer.
Bhai mere pas ek frontech ka computer ups hai usme aisa mother board nahi hai usme lambavala mother board hai usme 5min auto cut off kaise band karu bhai pls video banao
Can you please let know if the UPS is from Artis? In my Artis UPS board, R19 registor is not there but still it is auto-cutting off. How to disable this?
UPS मे IC555 लगी होती है जीसमे कम्पनी द्वारा टाईम सेट किया होता है , जो BC 547 से आगे की IC पर कन्ट्रोल होता है , कोई पुर्जा हटाने से टाईमीग नही बढती ।
@@BrothersExperimentAssam ak bada ic hay lakin r19 resistance nahi hay or ak mini ic hay lakin konsa wala resistance hatana hay wo nahi pata is topic pe ak video bana do please
Thanks you... it's very useful and working perfectly 🥰🥰🥰
Wonderful and useful video bro God bless you u more knowledge 🙏
Very informative video thanks for it keep it up and help us
Good evening super experience explanation 5 minutes atocut resistance remove problem salve tq🤝🤝🤝👌👍🙏🙏🙏
Excellent dada... Khub khub helpful video ...ata sotti kaj kora 😍😍😍
Thank you vaii ghar kot hoi 2mar
Bahut badiya bhai
Thanks bro mere mai work ho raha mera ups frontech ka hai
Sir Mera ups inverter me pcb board ke andar R19 resistance nehi hai to kehse karna hoga long Mather board hai
Bhai bahut hi badhiya video banaye ho yahi problem mere v ups me hai
Very helpful video,
Lekin success nhi hai 5min.baad cutoff ho ja rha r19 resistance ko nikalne ke baad v
Aapka video success nhi hai qki maine ye prayog kar liya 5min.cutoff ho ja rha hai
Lekin mera ups atchi tarike se km kor raha hai
@@BrothersExperimentAssam Bhai tumhara video edit Kiya hua hai
Very Useful Video...Thank You for making video on my Request.. kya yeh trick Intex Protector 725 UPS me work hogi ?
725 ups me work korega ki nehi tray korke dekhna porega
Great, working.
Thank u 😊 so much Bhai 😍 super love from Assam bhaut bhal lagise
ধন্যবাদ😍😍
thank you Bhai 😍 Bhai moi tu apunar channel 1k subscribers r porai follow kori asu . Bhaut bhal lage dei apunar video Bilak😍. Moi nijeu eta channel khulisu apunar pora inspire hoi. Ei link tut ebar click kori dibo please ruclips.net/channel/UC_8LddpYA_GkDXlS5uRe-1Q
Nissoy Sam aru lagi thaka adin success hoba
@@BrothersExperimentAssam 😊😊🥰 dhanyabad Bhai 😍 thanks
@@simpleinventions3168 ghar kot hoi 2mar
thanks bro😘😘😘
thanks bro......
Hello sir hamare pass kdkee ka ups hai lekin 1/1 mosfet laga huwa hai hamko 2/2 mosfet lagana hai kitna ka mosfet lagaye
Ekdum sahi hai bhai mene kiya hai..
R19 cute karne ke bad bhi ups off horaha hai please reply
IC 555 मे टाईमीग कम्पनी द्वारा सेट की होती है , किसी पुर्जे को इधर ऊधर करने से डेड ही होगा UPS
Thanks bro
Usefull❤
iBall nirantar 621v ups hai mera usme r19 resistance hatane se ups on hi nhi ho Raha hai sir is ups ko long time backup kaise le video banao.
Nice video bru
Very good solution
Ye ups khas pc ke liye design hai aur ye kit nya advance smart mode me aata hai agar galti se hum pc shutdown karke ise band na kre to automatically ye ups band ho jata hai taki hmara bil km aaye ye advance future isme hai aur isse pahle ke ups Jo lambi kit ka tha usme ye advance future nhi hai isliye woh purane ups se hum light ya mobail charge kr skte hai lekin nye adwance walese nhi bhai ne nye ups me jugad kr diya thanks mere pas dono ups hai isliye mujhe ye bat smj aayi aur jo pc hardware repair ka kam krte hai unhe bhi pata hogi shayad
Ha bhai, lekin koi aur kam me leta ho tab ye jaruri hai
Mere paas aap jaisa zebronic ka ups ka mother board hai usme Rellay ka track born ho gaya hai ups nahi on ho Raha hai kya Rellay kharab hai
I have same board , removing r19 works. I have connected 150 AH ,but it shutdown after 2 hours automatically, any solution?
Bro please 🥺 make video use extra battery current leaked
very good all of this idia
Very nice ji sar
Good job👍👍
Thank you 💚💚
Ye ups bord mai jo buzzer hai uske niche smd diode hai uska no bataon aplz mere wale ups mai o jal gya hai to no nhi dikh
Hi you're always excellent. Your video are all informative. Please let me know is it possible to increase mosfets add extra mosfet in this ups. please reply. Please also let me know is it possible to add extra transformer.
thank you ji 😊😊 or ups kit me extra mosfet or tranformer nehi lgaa sakte 😊😊
Bhai ZEBVU Model:ZEB-U725 ko oto kat hoany say ksay roky btao bhai 🙏
Bhai... ei trick a desktop ot current gole besi time cholibo nki
ধন্যবাদ
Bhai mere pas ek frontech ka computer ups hai usme aisa mother board nahi hai usme lambavala mother board hai usme 5min auto cut off kaise band karu bhai pls video banao
Mere ups KO board may r19 Ka ragistor Nahi hai k say solutions Kare may
Supar 👌👌👌
How much battery backup ???? Increased one computer.
Kiya ye ups 14 v me work karega....
Can you please let know if the UPS is from Artis? In my Artis UPS board, R19 registor is not there but still it is auto-cutting off. How to disable this?
Complain to company😁
@@someoneliving1 😂😂
PCB ka Solutions bataye sir..
yeh solar say kaisay charge hogaa???
Really very very useful and also helpful... Thanks
Sir Mena Battery terminal wrong connection car diya ..board on nahi ho raha h
Bhibis ups ki overload protection kyse bypass kare..?
Bhai ye hi rajistar hataya hu mai apne Intex ups se to ups pura off ho gya tha jod diya to wapas chalu ho gya
कनेक्टर साईड मे एक हरा रेसिस्टंन्स खडा लगा है, उसकी व्हॅल्यू क्या है
Ata kon company ka ups ar pcb board
My circuit resistor smd. It removed r19 smd resistor it work or not help me
It will also work in smd
Bro low battery auto cut kese band kare
Ishme bek shit me jo ic rehti ripey kare
Ok
Auto cut ko disable karne par ups 9 watt LED bulb ko kitne ghante Tak jala sakte hai. Waiting for your reply please . Thank.
Bhai Battery Ka ah por dipend korega. 🙂
Mera R19 cut karne ke bad kam load pr chal raha cpu ka load pr band ho raha kya karu
Ye pcb naya kaha milega
SKIP TO 4.20 TO SAVE YOUR VALUABLE TIME ...!!!
Bhai mera ups me long bip sound aa rha hai koi lod nhi chal rha h kya problem ho sakta hai
Ha Bhai Mera bhi load nhi le Raha
Pic16f72 computer UPS up sukham old PCB auto cut kaise band Karen
Hello brother,
My ups is getting off after 4 beeps after disconnecting ac power...can you please suggest me any solution
Ic check korke dekhiye
Agar hum registan ko hata de tu charge hone me docket nahi hoga na
Nehi hoga bhai
👍👍👍
100% working..
Thanku sir...
this is pure sine wave or modified sine wave???
pure shine wave not a modified shine wave
Bhai yahi kiya or on nhi hota hai help me
E bord how to bying
भाई मेरी kit में R19 का rajistens नही लगा हैं आप ko पिक कैसे bheju bataye कैसे चेक karu aa
Bhai capacitor OR diode ka side me hoga
Mera frontech ups hai mere ko r19 nhi mil rha hai
Vai me r19 ek leg khol diye but circut dead ho giye
UPS मे IC555 लगी होती है जीसमे कम्पनी द्वारा टाईम सेट किया होता है , जो BC 547 से आगे की IC पर कन्ट्रोल होता है , कोई पुर्जा हटाने से टाईमीग नही बढती ।
Brother mera sawal ye hai ki UPS ka transformer 0-6 v ka hota hai to fir ye 12v ki battery ko charge kaise kar leta hai.
Primary side me extra winding hota hai charging keliye green yellow blue black
@@BrothersExperimentAssam wo to 140v ka hota hai na ?
@@yogeshkumardewangan7438 140 nehi thora alag hota hai ye transformer
@@BrothersExperimentAssam to kul mila kar transformer ke secandry coil se hi hota hoga na charging to.
All redy remove R19 resistor but not continew work
Next video diya hunkale ❤️
okk 😁😁
भाई जि डेलटा ईनभटर का यवाला पोबलमका केसे समाधान होगा
Sir battery 10 volt ka niche chal sakta hai
10 volt ka niche Low Battery dikhata hai
Ye board luminous ups ka hai
Kitne wat Tak is per load Chala sakte hain
max 300w
सर धन्यवाद,इसमें कितने वाट का लोड दे सकते है।
300 watt
Sir mere 300 nahi 70 watt ka bhi load nahi le Raha kya hua hoga
ups cord me deiod khrab ho gya he konsa leaga
Konsa diode
Mera ups 750 ka hai microcantolar ic 650 ka hala hai 2 minute me off hojata hai kyu
Help
Off nhi hoga thik hai but battery 🔋 turant down ho jata h . Output voltage bad jata h bulb heat ho jayega....bekar hai ye sab inverter nhi hoga bhai
Kya hum ise 360 watt se 600 watt kar sakte hai kya ??
Nehi ups ka watt fix hota hai
@@BrothersExperimentAssam 12 v ke battery ke limit se 360 watt ka hi limit honga
Yah motherboard kiss ups mein laga hai
Su Kam ups me R19 hatane par bhi kam load me band ho ja raha hai । Ab kaise होगा ।
Same here bro
Hello bhai pls reply me main kese dhundu bhai r29 resistor kionki mere ups me bhai smd wala resistor hai r19 number prrr
2 capacitor c10 or c2 ak d12 diode pass he ye resistance
@@BrothersExperimentAssam bhai ak diode kon sa hai
@@BrothersExperimentAssam can i contact you on instagram
Diode location d12
@@BrothersExperimentAssam bhai instagram prr dm kr skta hu sir?
Apne double battery use Kiya h koi problem to Nahi Hoga n
Mera zebronic Ka ups h kya isme ho Sakta h . Kyki apka video dhekh kr try krne wala hu
Nehi kush problem nehi hoga
R19 me ne nikala pora ups band ho geya
IC 555 मे टाईमीग कम्पनी द्वारा सेट की होती है , किसी पुर्जे को इधर ऊधर करने से डेड ही होगा , टाईमीग नही बढेगी ।
Bhai mere ups keypad mein relay kharab ho gaya hai
Sir 100w ke bulb me ups 1 minute me band ho rha battery new hai fir bhi
Fan chalkar dikhya?
Computer ko kuch nuksan toh nahi hoga na bhai.
Nehi
Bhai disconnect karne ke baad ups on nhi ho Raha hai
Ups battery point me current mar raha hai keise thik kare
Apka MOSFET short ho goya hai Akbar MOSFET ko change korke dekhiye
Sir R19 nahi hai ..
Bhai mere ups me yea resistance nahi hai ma kaya karu ma kayse thik karu
Apka ups me ic se feedback hota hai
@@BrothersExperimentAssam ak bada ic hay lakin r19 resistance nahi hay or ak mini ic hay lakin konsa wala resistance hatana hay wo nahi pata is topic pe ak video bana do please
Pls tell me
Bhai mera nhi ho Raha ye Tarika
Vai kaj nehi hua plz tell me another trick
7ah ki battery 12 watt ka load kitna time backup dega?
12 hours 12 w led ligt
@@BrothersExperimentAssam 12volt 12ah Battery se Ek PC OR ek Desktop 4minute se jyada nehi chal raha hai,, iska kya solution ho sakta hai
R19 numer mila but register nhi mila
Luminus ups ka dikha
Our ups ot resistor tu besari puwa nai.... Video ata bonai deyok
thakibo xokolo circuit r design beleg belag hb pare
Nhi ho rha