Hydrant Ops with Boost Engine

Поделиться
HTML-код
  • Опубликовано: 22 авг 2024
  • This video details the use of a second engine to boost the water supply through a hydrant assist valve after the first due engine performed a forward hose lay.

Комментарии • 10

  • @IcedEarth426
    @IcedEarth426 3 года назад +5

    Thank you for these videos. As a new FF I'm still learning the basics of how these kinds of operations go. Seeing it in action along with an explanation is very helpful.

  • @joshroten3997
    @joshroten3997 4 месяца назад

    During my career we called them 4-way valves and they work great, especially in areas where you have and use hydrants a lot, and run two-piece engine companies (or single engines that are used to working one as attack and one as supply). Great tool.

  • @apodaca309
    @apodaca309 3 месяца назад

    Good class now i have to sell it to the brass is there any benefits with iso

  • @rodimus371
    @rodimus371 2 года назад

    Good stuff thank you for posting

  • @curtisvincentz7290
    @curtisvincentz7290 2 года назад +1

    Hypothetically, if the hydrant is only capable of 1500gpm, how is robbing water from the same outlet port going to increase water output? Your utilizing the same GPM …

    • @stephenhusak6098
      @stephenhusak6098 Год назад +3

      You arent increasing volume, you are increasing pressure for long hose lays.