How To Run Sprinkler Wire

Поделиться
HTML-код
  • Опубликовано: 26 июн 2019
  • Shop Direct Burial Wire: www.sprinklerwarehouse.com/pr...
    Sprinkler Warehouse Pro Adrian Sanchez talks with the Steve Okelberry Irrigation Professional and owner of Sprinkler Warehouse about how to run sprinkler wire in your yard's irrigation system.
    🌿 Sprinkler Warehouse: Your One-Stop Shop for Irrigation & Landscaping Needs 💦
    bit.ly/sw-homepage
    We offer a hefty selection of professional-grade products for both contractors and DIY enthusiasts, from smart solutions for efficient water management to sprinkler system accessories to the repair tools to keep everything running smoothly.
    _____________________________________________
    Shop All Categories:
    Shop Controllers → bit.ly/sw-controllers
    Shop Drip Kits → bit.ly/sw-drip-kits
    Shop Rotors → bit.ly/sw-rotors-
    Shop Spray Heads → bit.ly/sw-spray-heads
    Shop Valves → bit.ly/inline-valves
    Shop Blu-Lock → bit.ly/sw-blu-lock
    Shop Nozzles → bit.ly/sw-nozzles
    Shop PVC Fittings → bit.ly/sw-pvc-fittings
    RUclips comments are not monitored. Please direct your questions to the customer service representatives on www.sprinklerwarehouse.com. Warehouse hours are 8am-5pm Monday through Friday.
    #sprinklerwarehouse
    #irrigation
    #sprinklersystem
  • ХоббиХобби

Комментарии • 30

  • @ericnewton5720
    @ericnewton5720 3 года назад +14

    That coil in the wire will do nothing for power surges... lol. Although it sure looks fancy.
    The only way to protect against surges, is the excess voltage above your desired voltage, has a way to go to ground without going through the solenoids into the water.

    • @54565syu
      @54565syu 3 года назад +2

      Yup that’s why they are starting to put ground rods in for timers

    • @greengoat5654
      @greengoat5654 Год назад

      Now hold on, what's up with those I am iron things that come around sensitive electronic cables and how would grounding affect anything, you're not grounding out your live circuit me hopes

    • @greengoat5654
      @greengoat5654 Год назад

      @@sammyjoe2390 shhhhhhhhh

  • @dalatina911
    @dalatina911 Год назад +1

    Wow awesome video, very informative!!

  • @djea3589
    @djea3589 Год назад

    KUDOS to you: I am a sparky. I have NEVER heard anyone except for me tell anyone else to leave an extra 12 inches of wire in a panel. I ALWAYS leave extra in every box, device box as well as panel. When you get good at it no one will even notice the extra wire....until they need it and eventually they will need it.
    BTW, if you are a pro company and running wire like this, use different colors for different valve banks. If you had red, black, blue you would know that red was zones 1-4, black 5 - 9 and blue 10 -14 etc. Similarly one could use color codes for bubblers and sprinklers etc, so that the zone doesn't matter, only the kind of device. The time should be the same for every zone of the same type and group by type in the controller for easier programming.
    However, Underground Feed wire like 16/4 through 16/10 is a LOT easier to run and every solenoid would be on one color ( and you would have extra wires in the bundle if one had a problem. That would give you 9 zones.

  • @noeeon9910
    @noeeon9910 3 года назад +3

    You guys should waterbore next time. Put a 2inch nozzle at the end of a 3/4" sch40 pipe and thread a hose bib adapter on the other end. And there you have a water bore.

  • @JEK
    @JEK 11 месяцев назад

    awesome thank you for saving me time and money.

  • @Son_of_Aragorn
    @Son_of_Aragorn Месяц назад

    Is 16 AWG "marine wire" good for sprinklers? Wasn't sure if all 16 AWG wire are created equal. Thank you!

  • @cspill99
    @cspill99 Год назад

    I have old copper piping ran for my wiring encase. Is it possible to run the wire through the soldered pipes. I'm thinking the issue would be the 90 degree turns. Any suggestions or should I just bury it? How deep?

  • @heroknaderi
    @heroknaderi 4 года назад +1

    You guys are very amazing and helpful 👍

    • @manuelgallardo2621
      @manuelgallardo2621 4 года назад

      Can you make a video step by step how to connect the valves

    • @kevinm8865
      @kevinm8865 4 года назад

      @@manuelgallardo2621 I don't believe Kevin Naderi makes videos. You can reach out to SprinklerWarehouse.com support. They have lots of videos online.

  • @noeeon9910
    @noeeon9910 3 года назад

    Also not a bad valve manifold..

  • @zazaazuza6969
    @zazaazuza6969 3 года назад +8

    Why do you use many single wire cables instead of one multiple wires cable?

    • @gastcast2959
      @gastcast2959 3 года назад +1

      Probably cheaper in bulk

    • @noeeon9910
      @noeeon9910 3 года назад

      Because multistrand is trash, lol ok it's not trash it has its uses. But single strand is way better.. and just like pipe sizing you have to account for losses based off your wire thickness ( gauges )

    • @mefirst4266
      @mefirst4266 2 года назад

      BECOS THE BOYS PROBABLY STOLE THEM LAST NIGHT...... WHAT THE HELL DO YOU THINK..........

    • @mefirst4266
      @mefirst4266 2 года назад

      OR IT COULD BE TOO SEE IF THEY CAN COUNT................

  • @platinumlawnservice
    @platinumlawnservice Год назад +3

    I hate seeing a bunch of red wire when trying to diagnosing problems. I much prefer a unique color for every valve

  • @johnkosheluk1041
    @johnkosheluk1041 3 года назад

    Or there is a output term in the controller

  • @kayrealist9793
    @kayrealist9793 Год назад +1

    I think its always better to put those wires in a pvc pipe of some sort. When trees and plants root around the area it could ruin your wires causing some major headache.

    • @graphguy
      @graphguy Год назад

      ya PVC pipe is dirt cheap, no need to not spend the extra pennies.

  • @johnkosheluk1041
    @johnkosheluk1041 3 года назад +2

    That coil wires does not cause a noise choke in the wire

    • @mefirst4266
      @mefirst4266 2 года назад

      IN ELECTRONICS IT DOES ...... BUT THIS IS I READ A BOOK IN HOME DEPOT AND I JUST KNEW THAT I COULD BE A GREAT INSTALLER NOW.

  • @MrCubansurfer
    @MrCubansurfer 3 года назад +2

    Why don’t you use a real smart controller like the Rachio 3 🤦🏻‍♂️

    • @mefirst4266
      @mefirst4266 2 года назад

      AHHHH LOOK AT THE ILLIGLE HELP ....... DOESN'T THAT ANSWER THE QUESTION !!!!!!!!!!!! IF HE DID THAT THEN HE WOULD HAVE TO PAY THE MF'S $5.5O AN HOUR........

  • @adamchou9123
    @adamchou9123 2 года назад

    If anything, it's 2.5 extra feet of wire they sell you

  • @bonniemittleman6963
    @bonniemittleman6963 Год назад

    I wish I had Hired you. I paid 5k in early March 20 for an 8 zone system. One zone never worked. All pipes and wires are exposed to surface. No proper water distribution. And a manifold in a walkpath already two people have fallen on it. And so many More issues. I'm gradually trying to fix issues. But have lost more than 10k in landscape. And cried many nights. Now I know.

  • @vicbranson1061
    @vicbranson1061 Месяц назад

    Stupid video. I see guys working, but no one explaining whats going on.