We made it Vfd Motor parameters as per motor name plate details , but the motor current is showing wrong 12A in hmi but the actual motor current is 6Amps , what is my mistake? Please share the details
Ramp timings control the time that is taken to either start the motor and ramp it up to the required speed (ramp-up) or the time it takes to slow the motor down, normally to a standstill (ramp-down).
My V20 is having its frequency value flashing and not running. Also, if I power recycle, its parameters get reset . I guess it should be in configuration mode. How to bring it back to normal ?
Dear sir mere pas v20model drive hai, jo ki potentiometer se speed control ho rahi hai,, but I want, one more frequency that is fixed, when I give an input, then it should be at that fixedfrequency, after input off it should be operate on potentiometer speed, please tell me the parameter no. And input connection terminal.
With firmware version 3.9.5, the parameter p291 has got two additional bits added. Bit 3 and bit 4. These two additional bits were for development use and the added functions are disabled from default. However, it has been found that if cloning from an earlier version, bit 4 can inadvertently get set to "0", activating an additional detection. So with certain motors or with loads, F23 can be generated due to the ripple seen on the DC link. Disabling the F23 Trip Due p291 is service mode protected p3950 must be set first to 46 for access. If access is done from the BOP then this parameter will be saved automatically. If access is done from the Smart access module the settings will need to be saved manually. In p291 there are now the bits 0 to bit 4. The bits 0 and 4 needs to be "1". The bits 1, 2 and 3 needs to be "0" So the binary bit pattern is "10001" and p291 will this will show "11" in Hex So setting p291 to 11(Hex) will disable the trip with F23.
This message occurs when internal switching is incorrect or absent. Possible reasons are problems with electromagnetic compatibility and hardware or software lack of connection. You need to reset the error and if it persists, replace the converter.
This type of error indicates that the motor power is too high, the load cycle is high, and the frequency converter overloads. To troubleshoot, you need to check the electric motor's and frequency converter's technical characteristics and ensure that the load cycle does not exceed the limit values.
Nice🎉
EXCELLENT INFORMATION SIR.
Its very helpful and I set a VFD after watching this video. And I succeeded in setting everything and running well.
Thank you so much Vai.
Thanks sir
Nice video
Again thanks for
Today help me
Very nice video bhi
Ye barabar banaya, 1 no
Super explanation Thank you sir
Very good explanation
Please do one video on VFD faults and rectification
Sure. I will make and upload soon
Good
Nice detail
Hi sir tq u
We made it Vfd Motor parameters as per motor name plate details , but the motor current is showing wrong 12A in hmi but the actual motor current is 6Amps , what is my mistake? Please share the details
Hamaray pas edhr uae yahi darive lgi hoi hai .jab as ko on krtay hai to on ho jati hai magar pamp nai on hitay .kai dfa aysa ho chuka hai .
??
How to connect e stop push bottom in the vfd circuit
How to set parameter for using Do1+ Do1- as a Run feedback while vfd starts and stop
Speed ref perameter? For potential meter
Thanks sir ..nice clear explain.. 🎉🎉🎉
Sir if any timer control in drive stop after commend motor stopped later
Yes you can set the delay timing to stop and start
@@bossvlogs8822 why ramp up and ramp down available in vfs
Ramp timings control the time that is taken to either start the motor and ramp it up to the required speed (ramp-up) or the time it takes to slow the motor down, normally to a standstill (ramp-down).
My V20 is having its frequency value flashing and not running. Also, if I power recycle, its parameters get reset . I guess it should be in configuration mode. How to bring it back to normal ?
Sir motor temperature ka parameter konsa he
Dear sir mere pas v20model drive hai, jo ki potentiometer se speed control ho rahi hai,, but I want, one more frequency that is fixed, when I give an input, then it should be at that fixedfrequency, after input off it should be operate on potentiometer speed, please tell me the parameter no. And input connection terminal.
Which frequency is fixed?? And which frequency are you controlling through the potentiometer?? and what you want?? I didn't understand
V20 को मुझे 3 स्पीड मे चलना है cn003 मे तो इसके कॉन्टेक्टर के कनेक्शन डाइग्राम बना कर दे सकते हो
Selector switch and auto mode and hand mode and relay connection setting parameter number sir
F-72 fault how solve this problem please help
Which parameter should be set in VFD to see frequency of vfd on HMI.
For that you have to change the wiring and the program also..
@@bossvlogs8822 may we know the diagram connection between vfd and hmi? Thank you.
Potentiometer ki setting bhi to batani chahiye
Sir my Motor feeber converter fault
Bahut hi sunder jankari sir thank you. kya vfd market me milta hai kya price hai bataye
Sab VFD market ne available hai…price VFD ke model par depend karta h
@@bossvlogs8822 right
Will it run with out minimum frequency?
Yes, but it will depend on the load and motor capacity..
Hello
2:23 SINAMICS V20 is showing continuous F23 error , pls help to resolve
With firmware version 3.9.5, the parameter p291 has got two additional bits added. Bit 3 and bit 4.
These two additional bits were for development use and the added functions are disabled from default.
However, it has been found that if cloning from an earlier version, bit 4 can inadvertently get set to "0", activating an additional detection.
So with certain motors or with loads, F23 can be generated due to the ripple seen on the DC link.
Disabling the F23 Trip
Due p291 is service mode protected p3950 must be set first to 46 for access.
If access is done from the BOP then this parameter will be saved automatically.
If access is done from the Smart access module the settings will need to be saved manually.
In p291 there are now the bits 0 to bit 4.
The bits 0 and 4 needs to be "1". The bits 1, 2 and 3 needs to be "0"
So the binary bit pattern is "10001" and p291 will this will show "11" in Hex
So setting p291 to 11(Hex) will disable the trip with F23.
Ran command ka parameter nahin bole please tell me
सर हमारे पास इसी मॉडल का ड्राइवर है ऑटोमेटिक रन हो जा रहा है क्या प्रॉब्लम हो सकता है सर
Uske handle ke throttle ko check karo ya wiring ka kuch issue hoga… ya fir handle me sensor ya limit switch laga ho
👌👌👌👌
Bhai 30kw pump k liye parameters kaisa set karna hy and vo pump auto mode me nahi chal raha hy
kaun sa parameters??
@@bossvlogs8822 VFD Siemens Sinamics V20
@@bossvlogs8822 send your wats app number bro
How to fixe f60 error ?
This message occurs when internal switching is incorrect or absent. Possible reasons are problems with electromagnetic compatibility and hardware or software lack of connection. You need to reset the error and if it persists, replace the converter.
F5 fault how to fix
This type of error indicates that the motor power is too high, the load cycle is high, and the frequency converter overloads. To troubleshoot, you need to check the electric motor's and frequency converter's technical characteristics and ensure that the load cycle does not exceed the limit values.
मो नंबर मिल सकता है क्या भाई
Sir ap k wp number mil sakta hai.
Bhai numbr send kro
Bhai ap sabhi logo ka jo bhi query ho comments kar do answer mil jayega..
@@bossvlogs8822 right
Indi him password
I didn’t understand what you want to say, can you repeat again?
@@bossvlogs8822 which application you used VFD telescopic belt conveyor
@baikunthalenka2776 telescopic belt conveyor you can use for multiple work, like loading, unloading, materials transfer and many more.
@@bossvlogs8822 yes sir right indo application user I'd and password send please
@@bossvlogs8822 which place you work sir