How to set the parameters in Siemens VFD | Siemens sinamics V20 | VFD parameters

Поделиться
HTML-код
  • Опубликовано: 8 июл 2021
  • hello dosto agar aap channel pe naye hai to please channel ko subscribe kar le. thanks❤️
    #bossvlogs

Комментарии • 113

  • @jeetusadafule6913
    @jeetusadafule6913 6 месяцев назад

    Nice🎉

  • @muhammadasghar2762
    @muhammadasghar2762 6 месяцев назад +1

    EXCELLENT INFORMATION SIR.

  • @4thsubject359
    @4thsubject359 Год назад

    Its very helpful and I set a VFD after watching this video. And I succeeded in setting everything and running well.
    Thank you so much Vai.

  • @AwesomeMachineries47
    @AwesomeMachineries47 2 года назад +1

    Thanks sir
    Nice video
    Again thanks for
    Today help me

  • @RAJKUMAR-rz1gy
    @RAJKUMAR-rz1gy 3 года назад +2

    Very nice video bhi

  • @nitinsatle4536
    @nitinsatle4536 3 года назад +2

    Ye barabar banaya, 1 no

  • @amarendrachary1877
    @amarendrachary1877 6 месяцев назад

    Super explanation Thank you sir

  • @abdussamad2577
    @abdussamad2577 2 года назад +1

    Very good explanation

  • @pawankumar-oz5wt
    @pawankumar-oz5wt 6 месяцев назад +1

    Please do one video on VFD faults and rectification

    • @bossvlogs8822
      @bossvlogs8822  6 месяцев назад +1

      Sure. I will make and upload soon

  • @kspuri9694
    @kspuri9694 7 месяцев назад +1

    Good

  • @rakeshkumarrawat2144
    @rakeshkumarrawat2144 2 года назад

    Nice detail

  • @sundarmds5145
    @sundarmds5145 2 года назад +1

    Hi sir tq u

  • @ILAYARAJAraja
    @ILAYARAJAraja 5 месяцев назад

    We made it Vfd Motor parameters as per motor name plate details , but the motor current is showing wrong 12A in hmi but the actual motor current is 6Amps , what is my mistake? Please share the details

  • @dilawarkhan4838
    @dilawarkhan4838 Год назад +1

    Hamaray pas edhr uae yahi darive lgi hoi hai .jab as ko on krtay hai to on ho jati hai magar pamp nai on hitay .kai dfa aysa ho chuka hai .

  • @MrMsJomol
    @MrMsJomol 2 года назад +1

    How to connect e stop push bottom in the vfd circuit

  • @user-qb2sf7xp4v
    @user-qb2sf7xp4v Год назад +1

    How to set parameter for using Do1+ Do1- as a Run feedback while vfd starts and stop

  • @kumarsaurabh3936
    @kumarsaurabh3936 5 месяцев назад

    Speed ref perameter? For potential meter

  • @karunakaran9631
    @karunakaran9631 2 года назад +1

    Thanks sir ..nice clear explain.. 🎉🎉🎉
    Sir if any timer control in drive stop after commend motor stopped later

    • @bossvlogs8822
      @bossvlogs8822  6 месяцев назад

      Yes you can set the delay timing to stop and start

    • @baikunthalenka2776
      @baikunthalenka2776 6 месяцев назад +1

      @@bossvlogs8822 why ramp up and ramp down available in vfs

    • @bossvlogs8822
      @bossvlogs8822  6 месяцев назад

      Ramp timings control the time that is taken to either start the motor and ramp it up to the required speed (ramp-up) or the time it takes to slow the motor down, normally to a standstill (ramp-down).

  • @Excited_Electron
    @Excited_Electron Год назад

    My V20 is having its frequency value flashing and not running. Also, if I power recycle, its parameters get reset . I guess it should be in configuration mode. How to bring it back to normal ?

  • @krunalprajapati3369
    @krunalprajapati3369 Год назад

    Sir motor temperature ka parameter konsa he

  • @mulayam3696
    @mulayam3696 6 месяцев назад

    Dear sir mere pas v20model drive hai, jo ki potentiometer se speed control ho rahi hai,, but I want, one more frequency that is fixed, when I give an input, then it should be at that fixedfrequency, after input off it should be operate on potentiometer speed, please tell me the parameter no. And input connection terminal.

    • @bossvlogs8822
      @bossvlogs8822  6 месяцев назад

      Which frequency is fixed?? And which frequency are you controlling through the potentiometer?? and what you want?? I didn't understand

  • @ajaygoswami1363
    @ajaygoswami1363 2 года назад

    V20 को मुझे 3 स्पीड मे चलना है cn003 मे तो इसके कॉन्टेक्टर के कनेक्शन डाइग्राम बना कर दे सकते हो

  • @shravankumarnandhigam8963
    @shravankumarnandhigam8963 Год назад

    Selector switch and auto mode and hand mode and relay connection setting parameter number sir

  • @baikunthalenka2776
    @baikunthalenka2776 Месяц назад

    F-72 fault how solve this problem please help

  • @prosenjitsutradhar8802
    @prosenjitsutradhar8802 Год назад +1

    Which parameter should be set in VFD to see frequency of vfd on HMI.

    • @bossvlogs8822
      @bossvlogs8822  Год назад

      For that you have to change the wiring and the program also..

    • @mtiagil2305
      @mtiagil2305 6 месяцев назад

      @@bossvlogs8822 may we know the diagram connection between vfd and hmi? Thank you.

  • @abdussamad2577
    @abdussamad2577 2 года назад +1

    Potentiometer ki setting bhi to batani chahiye

  • @zyp51
    @zyp51 2 года назад +1

    Sir my Motor feeber converter fault

  • @GulabSingh-zc4kf
    @GulabSingh-zc4kf 2 года назад +1

    Bahut hi sunder jankari sir thank you. kya vfd market me milta hai kya price hai bataye

    • @bossvlogs8822
      @bossvlogs8822  2 года назад

      Sab VFD market ne available hai…price VFD ke model par depend karta h

    • @baikunthalenka2776
      @baikunthalenka2776 6 месяцев назад +1

      @@bossvlogs8822 right

  • @MrMsJomol
    @MrMsJomol 2 года назад +1

    Will it run with out minimum frequency?

  • @neerajschauhan1
    @neerajschauhan1 4 месяца назад +1

    2:23 SINAMICS V20 is showing continuous F23 error , pls help to resolve

    • @bossvlogs8822
      @bossvlogs8822  4 месяца назад

      With firmware version 3.9.5, the parameter p291 has got two additional bits added. Bit 3 and bit 4.
      These two additional bits were for development use and the added functions are disabled from default.
      However, it has been found that if cloning from an earlier version, bit 4 can inadvertently get set to "0", activating an additional detection.
      So with certain motors or with loads, F23 can be generated due to the ripple seen on the DC link.
      Disabling the F23 Trip
      Due p291 is service mode protected p3950 must be set first to 46 for access.
      If access is done from the BOP then this parameter will be saved automatically.
      If access is done from the Smart access module the settings will need to be saved manually.
      In p291 there are now the bits 0 to bit 4.
      The bits 0 and 4 needs to be "1". The bits 1, 2 and 3 needs to be "0"
      So the binary bit pattern is "10001" and p291 will this will show "11" in Hex
      So setting p291 to 11(Hex) will disable the trip with F23.

  • @shekharp5970
    @shekharp5970 Год назад +1

    Ran command ka parameter nahin bole please tell me

  • @darmandrkumar1401
    @darmandrkumar1401 Год назад +1

    सर हमारे पास इसी मॉडल का ड्राइवर है ऑटोमेटिक रन हो जा रहा है क्या प्रॉब्लम हो सकता है सर

    • @bossvlogs8822
      @bossvlogs8822  Год назад

      Uske handle ke throttle ko check karo ya wiring ka kuch issue hoga… ya fir handle me sensor ya limit switch laga ho

  • @vaghelasatish2995
    @vaghelasatish2995 2 года назад +1

    👌👌👌👌

  • @Contentsquad122
    @Contentsquad122 Год назад

    Bhai 30kw pump k liye parameters kaisa set karna hy and vo pump auto mode me nahi chal raha hy

  • @djzkddndnskskskd2727
    @djzkddndnskskskd2727 5 месяцев назад +1

    How to fixe f60 error ?

    • @bossvlogs8822
      @bossvlogs8822  5 месяцев назад

      This message occurs when internal switching is incorrect or absent. Possible reasons are problems with electromagnetic compatibility and hardware or software lack of connection. You need to reset the error and if it persists, replace the converter.

  • @karunakaran9631
    @karunakaran9631 7 месяцев назад +1

    F5 fault how to fix

    • @bossvlogs8822
      @bossvlogs8822  6 месяцев назад

      This type of error indicates that the motor power is too high, the load cycle is high, and the frequency converter overloads. To troubleshoot, you need to check the electric motor's and frequency converter's technical characteristics and ensure that the load cycle does not exceed the limit values.

  • @sateshchavan9415
    @sateshchavan9415 Год назад +1

    मो नंबर मिल सकता है क्या भाई

  • @dilawarkhan4838
    @dilawarkhan4838 Год назад

    Sir ap k wp number mil sakta hai.

  • @prabhatranjan3516
    @prabhatranjan3516 Год назад +1

    Bhai numbr send kro

    • @bossvlogs8822
      @bossvlogs8822  Год назад

      Bhai ap sabhi logo ka jo bhi query ho comments kar do answer mil jayega..

    • @baikunthalenka2776
      @baikunthalenka2776 6 месяцев назад

      @@bossvlogs8822 right

  • @baikunthalenka2776
    @baikunthalenka2776 7 месяцев назад +1

    Indi him password

    • @bossvlogs8822
      @bossvlogs8822  6 месяцев назад

      I didn’t understand what you want to say, can you repeat again?

    • @baikunthalenka2776
      @baikunthalenka2776 6 месяцев назад +1

      @@bossvlogs8822 which application you used VFD telescopic belt conveyor

    • @bossvlogs8822
      @bossvlogs8822  6 месяцев назад

      @baikunthalenka2776 telescopic belt conveyor you can use for multiple work, like loading, unloading, materials transfer and many more.

    • @baikunthalenka2776
      @baikunthalenka2776 6 месяцев назад

      @@bossvlogs8822 yes sir right indo application user I'd and password send please

    • @baikunthalenka2776
      @baikunthalenka2776 6 месяцев назад +1

      @@bossvlogs8822 which place you work sir