Sir same video hai.only .apko 6nos prameter extra set karna hoga.baki settings same hai. Ager apko chahiye to hum.details bhej dunga .ok sir. Thanks for watching this video
Setting parameters |Parameter P2179 P2180 Function Delay time for motor is blocked [ms] Current limit for no loadidentified [%] Delay time for noHoad identification ms] Setting Defines the delay time for identifying that the mo tor is blocked. Range 0 to 10000 (factory default 10) This parameter defines the threshold current for A922 (no load applied to inver ter) relative to PO305 (rated motor cur- rent) Range 00 to 10.0 (factory default 30) Defines the delay time for detecting a missing output load Range: 0 to 10000 (factory default 2000)
Sir p0011 lock prameter And p0012 unlock prameter Aap jo bhi code p0011 me dala hoga. Ohi same code p0012 me dalana hoga. Phir apka vfd unlock ho jayega. Ok ji
Realy ke jagah per aap direct lamps use kar sakte ho.koi problem nahi hoga.ok Lekin vfd realy ka voltage ⚡️ jarur dekh lena.230v Ya 24v dc. Usi hisab se Utne voltage ka lamps use karo 👍
Vfd input single phase supply And vfd output moter cable connection karo.program karo.moter namplte dekh ke. Bad me moter start ho jayega. Very easy sir. Phir bhi kuch problem ho mujhe comments karo
F2 fault shows up while drive is running at either half or full speed, not during ramping action. I will change deceleration time to higher value. System voltage is 480v, 3 phase F2 दोष तब दिखाई देता है जब ड्राइव आधी या पूरी गति से चल रही हो, रैंपिंग क्रिया के दौरान नहीं। मैं मंदी के समय को उच्च मूल्य में बदल दूंगा। सिस्टम वोल्टेज 480v, 3 चरण है Phir bhi kuch problem hai to.mujhe comments kijiye please
Dear sir mere pas v20model drive hai, jo ki potentiometer se speed control ho rahi hai,, but I want, one more frequency that is fixed, when I give an input, then it should be at that fixedfrequency, after input off it should be operate on potentiometer speed, please tell me the parameter no. And input connection terminal.
Maine di1 aur DI2 use kiya hai forward and rev ke liye,,, please tell me the another terminal no. Which I can use for fixed frequency, when sensor give input to vfd, it frequency should be changed, after input off it should be work on potentiometer speed.
Its settings are also included like press keypad. Still you don't know then. Watch the video of my G120 Siemens. It is on my channel. Keypad like this. Eska bhi iop 2 Ka settings same hai Ager apko malum nahi to.mera video hai g120 siemens vfd ka. Uska same keypad jaisa aap settings kar sakte ho.ok ji Thanks for watching this video
F20 appears in the display: Unexpected heating.Carry out a reset by turning the machine on and off. If the error can't be rectified, please contact Siemens Home Appliances Service and arrange a service appointment डिस्प्ले में F20 दिखाई देता है: अप्रत्याशित हीटिंग। मशीन को चालू और बंद करके रीसेट करें। यदि त्रुटि को सुधारा नहीं जा सकता है, तो कृपया सीमेंस होम अप्लायंसेज सर्विस से संपर्क करें और सेवा अपॉइंटमेंट की व्यवस्था करें
Sir apki video babut helpful rahta hai.
Etna details video koi nahi batata hai pure youTube per.thanks God
Sir Apke jaisa Etna details video koi Nahi banaya . thanks sir
Very good informative video
So nice of you
बहूत बढिया super
Very useful video sir 👍 👌 👏
So nice of you
Sir samz me aa gya thanks❤
Very useful informative video vfd related
So nice of you
Nice programming information
Thanks
Very good video
Thanks
Wow awesome
Thanks 🤗
Nice video
Thanks
Awesome video thanks so much
Very welcome
Super
Thanks
💯💯💯💯💪💪
Useful video
Thanks a lot
Very useful ☺️
Thank you 🙂
Very useful 👍
Thanks a lot
Sir v20me multi step speed settings ka video banaya
Sir same video hai.only .apko 6nos prameter extra set karna hoga.baki settings same hai.
Ager apko chahiye to hum.details bhej dunga .ok sir.
Thanks for watching this video
Thanx sir
Most welcome
Sir 0-10V output pe video banaiye pl
Bahut jald milega apko video
Autoprint offset machin me instal karneke bad iska perameter seting kia hoga
Sabhi settings same hoga ,lekin aap speed control mins hz apne hisab se set kar lena .ok
Thanks
Welcome
vfd ka fan chalu rahne ke liye konsa setting kare
Sabse Asan tricks vfd ko reset karke dubara se challu kijiye sahi ho jayega ok
Phir bhi problem ho mujhe comments kijiye please
Do vou have some video about calcule configure automatic motor p340?
Sir very soon you will get video on our channel. 👍
@@Ruchielectrical Thanks. It would also be nice to have a video on how to back up the parameters.
Backup prameter
P0010 >30 set
P0971 >1 set
👍
Thanks for joining my ruchi electrical team
Hi , thanks for video. How can i see torque?
Setting parameters
|Parameter
P2179
P2180
Function
Delay time for motor is blocked [ms]
Current limit for no loadidentified [%]
Delay time for noHoad identification
ms]
Setting
Defines the delay time for identifying that the mo tor is blocked.
Range 0 to 10000 (factory default 10)
This parameter defines the threshold current for A922 (no
load applied to inver ter) relative to PO305 (rated motor cur-
rent)
Range 00 to 10.0 (factory default 30)
Defines the delay time for detecting a missing output load
Range: 0 to 10000 (factory default 2000)
Thanks for joining my ruchi electrical team
Sir locked VFD ko unlocked karna ke lya paremater or password kya hoga
Sir p0011 lock prameter
And p0012 unlock prameter
Aap jo bhi code p0011 me dala hoga.
Ohi same code p0012 me dalana hoga.
Phir apka vfd unlock ho jayega.
Ok ji
sir , drive chalu hone pr led indicater bulb chalu karna hai , bina relay ka , kaise chalu kare
Realy ke jagah per aap direct lamps use kar sakte ho.koi problem nahi hoga.ok
Lekin vfd realy ka voltage ⚡️ jarur dekh lena.230v
Ya 24v dc.
Usi hisab se Utne voltage ka lamps use karo 👍
@@Ruchielectrical vfd relay voltage kaise check kare
Very nice useful video for VFD settings all in one
Thanks a lot
Sir iss VFD se single phase motor kaise run kare
Vfd input single phase supply
And vfd output moter cable connection karo.program karo.moter namplte dekh ke.
Bad me moter start ho jayega. Very easy sir.
Phir bhi kuch problem ho mujhe comments karo
Yes sir but F2 error ya rha hai ..input voltage ok hai
F2 fault shows up while drive is running at either half or full speed, not during ramping action. I will change deceleration time to higher value. System voltage is 480v, 3 phase
F2 दोष तब दिखाई देता है जब ड्राइव आधी या पूरी गति से चल रही हो, रैंपिंग क्रिया के दौरान नहीं। मैं मंदी के समय को उच्च मूल्य में बदल दूंगा। सिस्टम वोल्टेज 480v, 3 चरण है
Phir bhi kuch problem hai to.mujhe comments kijiye please
Can we drive a single phase motor using this vfd?
Yes sir can you run single phase motor using this vfd.
Thanks for visiting my channel
Ok sir thank you...Plese sir make on vedio on this
Which parameter is need to set
Sir transistor output relay connection wrong hai Do- mein 24- negative aayega aap ne positive loop kr rakha hai
Yes correct
Wiring time mistake ho Gaya hoga
Negative aayega
Dear sir mere pas v20model drive hai, jo ki potentiometer se speed control ho rahi hai,, but I want, one more frequency that is fixed, when I give an input, then it should be at that fixedfrequency, after input off it should be operate on potentiometer speed, please tell me the parameter no. And input connection terminal.
Terminal use di2 fixed speed
Di1 potentiometer
Prameter settings
P701 set 1 potentiometer
P702 set 2 fixed speed
Fixed speed frequency setting p1058
Apne pura video dekha nahi kya.
Usame hum details me bataya hu.
Ok don't worry
Thanks for watching and joining my ruchi electrical team
Maine di1 aur DI2 use kiya hai forward and rev ke liye,,, please tell me the another terminal no. Which I can use for fixed frequency, when sensor give input to vfd, it frequency should be changed, after input off it should be work on potentiometer speed.
Di2 and di3 use reverse forward
And di1 potentiometer
Di4 use fixed speed
Hi, How can I read rpm from an analogic port?
For this, you have to connect a meter to the vFD analog output terminal. Sale Peak 152 Can RPM Through Meters ok
IOP 2 setting tell us please
Its settings are also included like press keypad. Still you don't know then. Watch the video of my G120 Siemens. It is on my channel. Keypad like this.
Eska bhi iop 2
Ka settings same hai
Ager apko malum nahi to.mera video hai g120 siemens vfd ka.
Uska same keypad jaisa aap settings kar sakte ho.ok ji
Thanks for watching this video
Ok boss
Hello sir
Mere drive me f20ka fault aa rha hai
Please help me
F20 appears in the display: Unexpected heating.Carry out a reset by turning the machine on and off. If the error can't be rectified, please contact Siemens Home Appliances Service and arrange a service appointment
डिस्प्ले में F20 दिखाई देता है: अप्रत्याशित हीटिंग।
मशीन को चालू और बंद करके रीसेट करें। यदि त्रुटि को सुधारा नहीं जा सकता है, तो कृपया सीमेंस होम अप्लायंसेज सर्विस से संपर्क करें और सेवा अपॉइंटमेंट की व्यवस्था करें
मो नंबर मिल सकता हैं भाई
Kya kam hai bhai mobile no.se.
Description me hai. Mobile no.