Safety Relays: Part 1

Поделиться
HTML-код
  • Опубликовано: 14 окт 2024
  • Why do we use Safety Relays?
    1. Implementing various safety functions- commonly in plant environments
    2. Commonly used with other safety relays
    3. Each relay will monitor one specific function
    4. Contacts can be open or closed, like a normal relay
    5. Electronic evaluation, and control outputs based on evaluations
    6. Can be fully electronic
    7. Will still function if device fault occurs
    8. Redundant features help overcome wiring errors
    Devices that commonly use Safety Relays:
    1. Emergency Stops
    2. 3 Position Devices
    3. Safety Gates
    4. Pressure Sensitive Mats
    5. Contact Strips
    6. Foot Operated Switches
    7. Time Delay Scenarios
    Other videos on relays: • Time Delay Relays Basics
    Get the FULL video transcript here: www.rspsupply....
    Want to see similar products to those featured in this video: www.rspsupply....
    Check out our full line of Industrial Hardware on our website: rspsupply.com
    Additional Links -
    Website:
    rspsupply.com/
    Engineering Page:
    rspsupply.com/...
    Panel Fabrication Page:
    rspsupply.com/...
    Procurement Services Page:
    rspsupply.com/...
    Manufacturers Page:
    rspsupply.com/...
    Relays & Timers:
    rspsupply.com/...
    Industrial Safety:
    rspsupply.com/...
    PLCs & IO:
    rspsupply.com/...
    Signal Power Conditioning:
    rspsupply.com/...
    Terminal Blocks & Connectors:
    rspsupply.com/...

Комментарии • 22

  • @kevin00861
    @kevin00861 2 года назад +2

    Honestly;
    whenever I login to RUclips for self-turoring and find your good-looking face i like the video before I even watch it!
    keep up the good job!

  • @stevesaboe9671
    @stevesaboe9671 5 лет назад +16

    Also wondering when you guys are doing Pt. 2! Thanks!

  • @eytanmagen3615
    @eytanmagen3615 5 лет назад +2

    This is an normal use example of a safety relay , you may like to add them to this video .
    It takes two hands to activate these switches, minimizing the risk of accidental equipment start up. A complete system requires two switches, one safety relay, and two outlet boxes.
    Safety relays control the two switches by sending an output signal when both switches are activated within 0.5 seconds of each other. Self-monitoring circuitry offers additional protection-if any part of the system fails, the entire system shuts down until repaired.

  • @LBTennis
    @LBTennis 3 года назад +1

    If we ever have 1st contact with aliens, i want this guy to do the talking.

  • @chadhartley8067
    @chadhartley8067 4 года назад +1

    Still no part 2. Thanks guys.

  • @benjamin5562
    @benjamin5562 5 лет назад +5

    Still waiting on Part 2. Any word on when it might drop?

  • @holycraponcracker
    @holycraponcracker 6 лет назад +2

    Can you give a practical exam? Where a safety relay must be used rather than a standard one and why?

  • @aima2936
    @aima2936 5 лет назад +1

    I could not find the part 2,

  • @cagryagmur7849
    @cagryagmur7849 5 лет назад

    Than you for your effort , i learn a lot.

  • @movax20h
    @movax20h 4 года назад

    Are there any programmable Safety Relays that are controlled using microcontroller?

    • @ivanbratanov8699
      @ivanbratanov8699 2 года назад +1

      Yes, they are called safety PLCs. Their usement is still concentrated on safety, but user could implement individual logic inside it depending on specific project requirements. Safety PLCs have also a fieldbus interface to communicate with other PLCs. You may take a look at ABB Pluto series for example…

  • @ncameron7
    @ncameron7 4 года назад

    When are you releasing part 2?

  • @gybx4094
    @gybx4094 4 года назад +3

    Safety Relays are only required for SIL (Safety Integrity Level) certified systems. Some R&D systems don't even require safety relays. If you're only using an E-Stop to shutdown a system, then a Safety Relay may be overkill. It's never wrong to use it, but spending $400 for an Allen Bradley Guardmaster instead of using two $20 octal relays is a huge waste of money. I fully understand that production systems with dangerous conditions and numerous input parameters must have them.

    • @hugoburns8344
      @hugoburns8344 4 года назад +2

      to shutdown a system normally is used button "shutdown the system". The bundle E-Stop button and Safety Relay imply much more than simple "shutdown system". So usage of safety relay isn't overkill. Either you have reliable safety system or not. You pay $400 not for simple relay, you pay for relay with special features which encrease reliability of safety system implemented.That's the point.

  • @mohammadrashad9003
    @mohammadrashad9003 5 лет назад +1

    still waiting for part 2

  • @ToolsAandLogic
    @ToolsAandLogic 2 года назад

    You forgot to mention that safety relay has positive guided contacts. In case of welding of NO contact, all contacts are immovable and hence guarantee that no safety is comprised.

  • @DStan23
    @DStan23 5 лет назад +14

    They must be studying how these safety relays work. Because there is no part 2 even 5 months later.

    • @victoribi0361
      @victoribi0361 Год назад +2

      They have it now xd

    • @DStan23
      @DStan23 Год назад +1

      @@victoribi0361 about time buddy LoL

  • @sunimalfernando4347
    @sunimalfernando4347 6 месяцев назад

    ❤️❤️❤️❤️🫶✊