Sir I had seen lot of videos about civil engineering but doesn't got more clarity about certain topics but your way of explanation is very much easy to understand thanks a lot sir
The main purpose of stirrup is to hold the primary reinforcement bars. They also prevent columns and beams from buckling. The stirrups get placed diagonally when there is tension and compression caused by vertical and transverse tension.
Sir naanga veedu kattittu irukkom basement work la 1"6 jally mattum podanum. Ipa column rise pannanum. But meshthiri column rise pannaama belt concrete pottutaaru .so kambi length kammiyaa irukku.1 adi thaan irukku. 16mm rod use pannirukkom. Ellaarum solluraanga 2 1/2 adi yaathu venum apa thaan kambi rise panna mudiumnu. But antha meshthiri kambi rise pannaama vidduraaru. Corner pillars laiye intha pblm irukku. Itha epadi sari panrathu. Drilling panni rod 1 adikku irakki paste panni welding panna safe ah irukkumaa??? Load thaanguma ipadi panna?? Suppose 2 floor kattalaama safe ah irukkumaa ?? Ethuvum pblm varumaa?? 2. Oru pillar line vittu konjam thalli irukku. Atha epadi sari panrathu?? Column la king aduchu kambi rise pannalaamaa ??? Is that safe for 2 floors??? Plz give me your valuable suggestion. Intha situation la unga advice romba helpa irukkum sir.
In Framed Structure, What is the difference between Building a Structure Frame and Slab for all the floors and then later, work on Brick Walls & lentil VS Build the Brick walls along with the Structure Frame & slab on every floor?
Sir 9" Column 2 rod lapped in 4.5 feet from basement and another two rod lapped in 9feet from basement total column 12 nos all are same is there any problem plse help
The main purpose of stirrup is to hold the primary reinforcement bars. They also prevent columns and beams from buckling. The stirrups get placed diagonally when there is tension and compression caused by vertical and transverse tension.
அண்ணா உங்கள் வீடியோவை பார்த்த பிறகு தான் பொறியாளர் இல்லாமல் வீடு கட்டுவது தவறு என்று தெரிகின்றன பொறியாளரிடம் வேலை ஆட்கள் மிகச்சிறந்த முறையில் வேலைய செய்கின்றார் ஆனால் பிரர் இடத்தில் ஐம்பது சதவீதம் வேலை ஆட்கள் வேலையும் தெரிவது இல்ல வேலையும் செய்வதில்லை மிகுந்த வருத்தம் அளிக்கிறது அண்ணா
ஒரு தளம் மட்டும் செய்தாலும் எப்படி கம்பி இணைக்காமல் செய்ய முடியும். தோராயமாக ஒரு கணக்கு செய்து பார்ப்போம் Development length minimum 1'6" Foundation deapth minimum 5'0" Basement height minimum 3'0" Basement to roof top minimum 10'6" Future lab at parapet 3'0 Total height 23'0" வருகிறது. 23 அடிக்கு கம்பியை வெட்டி நிறுத்தலாம் என்று நீங்கள் கூறினால் மீதி 17 அடி கம்பியை என்ன செய்வது. மேலும் 23 அடி பில்லரை தூக்கி நிறுத்தி கையாள்வது சற்று சிரமம் இல்லையா. இல்லை 20 அடி என்று இரண்டாக வெட்டி பயன்படுத்தினால் ரூப் பீமில் 100% lapping வரும் அது முற்றும் தவறு இல்லையா. அதனால் கண்டிப்பாக lapping தேவைபடும் தானே நீங்களே சொல்லுங்கள்...
இல்லை சார் நீங்க ஒரே இடத்தில் ஜாயின்ட் வரகூடாது என்று சொல்லுறிங்க ஆனா வெளிநாடுகளில் எல்லாம் எத்தனை கம்பி இருந்தாலும் ஒரே இடத்தில் தான் ஜாயின்ட் பண்ணுற இதுக்கு என்ன பதில் சொல்லுறிங்க பதில் எதிர்பார்க்கிறேன் சார்
@@rantonyrmrmantony1180 இங்கு உள்ள structural engineer அனைவரும் கூறும் கருத்து சரியானது 50% க்கு மேல் ஒரே இடத்தில் lap செய்ய கூடாது அப்படி செய்தால் அந்த இடம் weaker zone ஆகும் . ஒரே இடத்தில் lapping வைப்பது தவறு என்பதே என் நிலைபாடு.
Nangalu vidu katta start pandrom full time unga videos tha
nalla videos enakku romba helpful sir super sir
Er sir,
Technial பற்றி தெரியா விட்டாலும்
வீடியோ பார்க்க ஆவலாக உள்ளது.
Keep it up.
நன்றிகள் ஐயா
Sir I had seen lot of videos about civil engineering but doesn't got more clarity about certain topics but your way of explanation is very much easy to understand thanks a lot sir
Thank you so much
Example you gave for lapping joint will not be forgotten in my entire life time sir thank you sir.
நன்றி
வணக்கம் ஐய்யா தங்கள் நல்ல முறையில் தகவல் தொகுக்கப்பட்டுள்ளது வாழ்துவோம்
ஐய்யா நன்றி🙏💕 தெரிவித்து கொள்கிறேன். தங்கள் விலாசம் தேவை.
Sir ,Ipo ground floor Mattum v2 katromna ...Apo column correct ah evlo length vaikkanum .....then ..nxt floor consider pannunomna ..Antha 1st floor ku lapping crcta entha potion la pannanum
மிகவும் பயனுள்ள தகவல் அண்ணண்😍.
Bar bending schedule video podunga sir
அருமை ங்க அண்ணா🌟.
Iii
Correct sir.... But if we follow this type of procedure there will be wastage of steels..... How to overcome this wastage.... Pls tell me sir.....
Anna column rod horizontala 4 no's of rod pottu erukinga.oru oru rodkku distance yevalu vaikkanunu oru viedo potinga and stirups pathiyum sollunga
அருமையான பதிவு அண்ணா 💐💐
Sir electrical and plumbing details ah oru video podunga
Nandri thalaivare❤
One fine information
அருமையான பகிர்வு
நன்றி
Neat explaination sir❤️
Brother naa footingla irunthu yeduthutu vara column steel yenna size la cut panlamnu keturntha
How to calculate labour cost for excavation to basement level pls upload one video for rate of labour work
Brother coloumn il ring etharkaga podavendum athan avasiyam enna
The main purpose of stirrup is to hold the primary reinforcement bars. They also prevent columns and beams from buckling. The stirrups get placed diagonally when there is tension and compression caused by vertical and transverse tension.
வணக்கம் சகோ நீங்கள் விலக்கியது சில இடங்களில் சற்று புரியவில்லை ....
ஓவர் லேப் செய்த இடத்தில் வெல்டிங் பன்னலாமா
Sir naanga veedu kattittu irukkom basement work la 1"6 jally mattum podanum. Ipa column rise pannanum. But meshthiri column rise pannaama belt concrete pottutaaru .so kambi length kammiyaa irukku.1 adi thaan irukku. 16mm rod use pannirukkom. Ellaarum solluraanga 2 1/2 adi yaathu venum apa thaan kambi rise panna mudiumnu. But antha meshthiri kambi rise pannaama vidduraaru. Corner pillars laiye intha pblm irukku. Itha epadi sari panrathu. Drilling panni rod 1 adikku irakki paste panni welding panna safe ah irukkumaa??? Load thaanguma ipadi panna?? Suppose 2 floor kattalaama safe ah irukkumaa ?? Ethuvum pblm varumaa?? 2. Oru pillar line vittu konjam thalli irukku. Atha epadi sari panrathu?? Column la king aduchu kambi rise pannalaamaa ??? Is that safe for 2 floors??? Plz give me your valuable suggestion. Intha situation la unga advice romba helpa irukkum sir.
Tomorrow call me 8428756055
நன்றி
Good Explanation Great
நன்றி
Sir footing epdi design pandrathunu soluingaa sir
Your videos are very well explained, keep going
can we use 12mm for column... and 8mm for footing?
In Framed Structure, What is the difference between Building a Structure Frame and Slab for all the floors and then later, work on Brick Walls & lentil VS Build the Brick walls along with the Structure Frame & slab on every floor?
Anna next video la . Column rod kink adikaradhu podunga
Great👍
Sir 9" Column 2 rod lapped in 4.5 feet from basement and another two rod lapped in 9feet from basement total column 12 nos all are same is there any problem plse help
Sir water tang pillar podalama solluga sir
Sirapu miga sirapu
சார் 6அடி காலம் குழி ராடு எவ்வளவு அளவு கட் பண்ணணும்
அருமை
நன்றிங்க அண்ணா
Vera level 🤗
Column il concrete podumpothu asaiyamal irupatharkaga va ring podugiroma please explai rings column il etharkaga poda vendum sollungal
The main purpose of stirrup is to hold the primary reinforcement bars. They also prevent columns and beams from buckling. The stirrups get placed diagonally when there is tension and compression caused by vertical and transverse tension.
Thankyou brother
Ena sir column remma large iruku....v2 da illa vera ethuvomma
Thanks
Thanks sir
Lindil beam la rings 135 degree valaikanuma
Yes
Kk
Vera level sir
அண்ணா உங்கள் வீடியோவை பார்த்த பிறகு தான் பொறியாளர் இல்லாமல் வீடு கட்டுவது தவறு என்று தெரிகின்றன
பொறியாளரிடம் வேலை ஆட்கள் மிகச்சிறந்த முறையில் வேலைய செய்கின்றார் ஆனால் பிரர் இடத்தில் ஐம்பது சதவீதம் வேலை ஆட்கள் வேலையும் தெரிவது இல்ல வேலையும் செய்வதில்லை மிகுந்த வருத்தம் அளிக்கிறது அண்ணா
Suppar
சூப்பர்
Nice sir 👍👍
சார் வணக்கம் அனைத்து அளவிலான கம்பி பில்லர்களுக்கும் கான்கிரீட் போடும் போது கவர் அளவு ஒரு இன்ஞ் அளவு போதுமானதாக இருக்குமா சார்
காலம் 1.5 இன்ச் கவர் வைக்க வேண்டும் சகோதரா
@@ErKannanMurugesan thank you sir
Super brother ena romba nal video ila
வேலை பளு சகோதரா... this video dedicated for you bro
அண்ணா, G+1 கட்டிடத்திற்க்கு lapping இல்லாமல் முழு நீளம் கம்பி காலம் அமைக்கலாமா
தூக்கி நிறுத்த முடியாது
10&10 ATI roof poda kambi cement kanakku video theliva puriyuramathiri podunga cement ethanai moottai kambi ethanai kg
Illanna ithulaye reply pannunga
Good sir
Camera correcta position panni kattunga kannu valikudhu ...
👍
Single Storey building column lapping is required or not required?
Column lapping is must for all storey
@@venuprasad7116 @Er Kannan murugasan sir direct ta footing to roof ..column rod place pannalam.. Illa cut panni Centre la lapping pannuma
ஒரு தளம் மட்டும் செய்தாலும் எப்படி கம்பி இணைக்காமல் செய்ய முடியும்.
தோராயமாக ஒரு கணக்கு செய்து பார்ப்போம்
Development length minimum 1'6"
Foundation deapth minimum 5'0"
Basement height minimum 3'0"
Basement to roof top minimum 10'6"
Future lab at parapet 3'0
Total height 23'0" வருகிறது.
23 அடிக்கு கம்பியை வெட்டி நிறுத்தலாம் என்று நீங்கள் கூறினால் மீதி 17 அடி கம்பியை என்ன செய்வது. மேலும் 23 அடி பில்லரை தூக்கி நிறுத்தி கையாள்வது சற்று சிரமம் இல்லையா.
இல்லை 20 அடி என்று இரண்டாக வெட்டி பயன்படுத்தினால் ரூப் பீமில் 100% lapping வரும் அது முற்றும் தவறு இல்லையா.
அதனால் கண்டிப்பாக lapping தேவைபடும் தானே நீங்களே சொல்லுங்கள்...
Correct sir.... But if we follow this type of procedure there will be wastage of steels..... How to overcome this wastage.... Pls tell me sir.....
After long gap.. Epdi irukenga bro
நல்லா இருக்கேன் சகோ. நீங்க எப்படி இருக்கீங்க...
@@ErKannanMurugesan nala irukom.. Enga veedu basement work mudiya pogudhu bro. Adhan full time site visit la irukren
நல்லது சகோ. நல்ல நினைவுகளை உங்களுக்கு வழங்கும்.
Nice anna
🙏🙏🙏🙏
Assalamu alaikum wa alaikum Salam wa rahmathllhi wa barakatuhu saroshkan shabika yen Roomba Nala video podalana
வீடியோ மூலம் கம்பி வேலைகள் அனைத்தும் தெரிந்து கொள்ள முடிகிறது
300rd like!👍👌
Hi sir
Bro unga contact kadikuma
இல்லை சார் நீங்க ஒரே இடத்தில் ஜாயின்ட் வரகூடாது என்று சொல்லுறிங்க ஆனா வெளிநாடுகளில் எல்லாம் எத்தனை கம்பி இருந்தாலும் ஒரே இடத்தில் தான் ஜாயின்ட் பண்ணுற இதுக்கு என்ன பதில் சொல்லுறிங்க
பதில் எதிர்பார்க்கிறேன் சார்
Answer me
இங்கு என்ன செய்கிறார்களோ அதைத்தான் நான் சொல்லமுடியும்.
வெளிநாடுகளில் அப்படி செய்கிறார்கள் என்றால் நீங்கள் அவர்களிடம்தான் கேட்க வேண்டும்.
@@ErKannanMurugesanஉங்கள் வீடியொ எனக்கு பிடிக்கும் ஆனால் இது எனது கேள்விக்கு சரியான பதில் இல்லை
இங்கு கண்சல்டிங் பண்ணுவதும் தமிழ் என்ஜினியர் தான்
@@rantonyrmrmantony1180 இங்கு உள்ள structural engineer அனைவரும் கூறும் கருத்து சரியானது 50% க்கு மேல் ஒரே இடத்தில் lap செய்ய கூடாது அப்படி செய்தால் அந்த இடம் weaker zone ஆகும் .
ஒரே இடத்தில் lapping வைப்பது தவறு என்பதே என் நிலைபாடு.
😅😂🎉🎉🎉