How to Replace S-Trap with a P-Trap | How Drain Plumbing Traps Work | Air Actuated Valve Install

Поделиться
HTML-код
  • Опубликовано: 31 июл 2022
  • I replace an illegal plumbing S-trap with a P-trap under the kitchen sink and install an air actuated valve in the system to act as the drain vent. I give a detailed description and illustration of how each of these plumbing traps function.
    Brettley Built features projects involving welding, electrical, plumbing, carpentry and much more. My channel is dedicated to teaching you how to do tackle projects yourself and save money. My wife, daughter, and I live in western Pennsylvania on six acres. We enjoy being outdoors, making improvements to our property, and making things. We adore our four dogs and three cats. We hope you enjoy our videos and spend time with us as we build and create!
    ▶️ ELECTRICAL VIDEOS PLAYLIST: • Electrical
    ▶️ CAROLINA CARPORT GARAGE PLAYLIST: • Carolina Carport Metal...
    ▶️ YANMAR TRACTOR PLAYLIST: • Yanmar Tractor
    ▶️ WELDING VIDEOS PLAYLIST: • Welding
    E-mail: brettleybuilt@gmail.com
    Facebook: / brettley-built-1012760...
  • ХоббиХобби

Комментарии • 86

  • @garyr193
    @garyr193 4 месяца назад +1

    Thank you, sir, for a great help in doing my utility sink in the basement.

  • @rescueponies4325
    @rescueponies4325 5 месяцев назад +3

    Love how clearly you explain all of this. I’ve been afraid of plumbing. But this makes me more confident. I want to put a new smaller vanity in a small bathroom which may require replumbing the sink p-trap. Thanks for this!!!

  • @robertlundgoot4736
    @robertlundgoot4736 4 месяца назад +1

    The best! No nonsense, very clear and concise.

  • @johngoold1218
    @johngoold1218 5 месяцев назад

    The video still helps out a year later - thanks for doing this. I need to change out several "S" traps in the house we are buying.

  • @W0lffb0y
    @W0lffb0y 4 месяца назад

    The detail in this video with all the tidbits. Thank you so much.

  • @jamesphilips4290
    @jamesphilips4290 Год назад

    Fixed up my S-trap kitchen sink thanks to your instructions, Thanks

  • @JeffSG71
    @JeffSG71 Год назад +3

    I’m currently installing a new vanity in a home we just bought and am dealing with an S-trap. Thank you for the instruction.

  • @lauriewilliams4557
    @lauriewilliams4557 6 месяцев назад

    Thank you Brett. This worked for me to change S-trap to P-trap.

  • @duniel2832
    @duniel2832 5 месяцев назад +1

    Awesome video! You saved my day! I really appreciate it! Thank you for taking the time and explaining so well!

  • @mrscheekymonkey24
    @mrscheekymonkey24 Год назад +1

    Thank you! Purchasing a house and the inspector noted s-traps. Feel confident now I can update them myself. ☺️

  • @hubbadubchub
    @hubbadubchub 4 месяца назад

    Incredibly informative and helpful. Thank you so much

  • @TruthSeeeker777
    @TruthSeeeker777 11 месяцев назад

    Great video! To the point, great camera angles, and explanations were cear and and easily understood. Thank you sir!

  • @bouvyc
    @bouvyc Год назад

    Excellent video! Thank you.

  • @davidlutz4423
    @davidlutz4423 3 месяца назад

    Thank you. This is the best and most instructive presentation that I have seen.

  • @odeemom
    @odeemom 5 месяцев назад

    This is such a helpful easy to understand video. Thanks

  • @oddysee3030
    @oddysee3030 Год назад

    Thanks so much! This was VERY helpful. I appreciate you :)

  • @JK-hd2zb
    @JK-hd2zb Год назад

    Nice job

  • @user-dv9dv5yy4p
    @user-dv9dv5yy4p 5 месяцев назад

    Uncle Eddie from National Lampoon was the reference. Thanks for the video!

  • @Yes_I_c4n
    @Yes_I_c4n 7 месяцев назад

    Great video, mate.

  • @dlloytl
    @dlloytl 8 месяцев назад

    Btw this is a great video and you Re great instructor

  • @SwolShark
    @SwolShark Год назад

    Great video!

  • @hippo-potamus
    @hippo-potamus Год назад

    Thanks for the video and explanation, I think I might as well replace mine as well. Did you just buy all the parts at the hardware store or do you have any amazon links for the items?

  • @saramynarcik8179
    @saramynarcik8179 Год назад +3

    Great video. Have you have any experience with diverting greywater from sinks? I'm currently building and would like to be able to switch the drain of the sink from going out to the yard (during dry season) back to septic tank when necessary (during wet season). I've looked at gate valves and/or ball valves to place under the sink for easy access in changing the flow.
    Any thoughts? THX!!

    • @brettleybuilt
      @brettleybuilt  Год назад +2

      I think the issue you would have with valves and gray water is clogging at the valve that will be shut off for months at a time. The thought that comes to mind is to put a clean out before each valve, that way when you go to divert the water you can open the valve that has been closed for months and flush out any debris that has accumulated. I think gate valves would work the best for this application.

    • @saramynarcik8179
      @saramynarcik8179 Год назад +3

      @@brettleybuilt Thank you for your response. Great suggestion for the clean out before the valve. Keep on making the very informative videos!

  • @anthonyrobinson973
    @anthonyrobinson973 8 месяцев назад

    What if I have an AAV beneath the sink but still have a smell when I unscrew the pipes near the
    S trap-- is that normal?
    Great Video. THANKS!

    • @brettleybuilt
      @brettleybuilt  8 месяцев назад

      Yes. If you disconnect the plumbing you will most likely have sewer smells. When everything is installed correctly, there shouldn't be any odors.

  • @miked1307
    @miked1307 9 месяцев назад

    Thank you for the great video. Question, do you always have to install the air actuated valve or is it situation dependent?

    • @brettleybuilt
      @brettleybuilt  9 месяцев назад

      If you can tie into a vent pipe it is better to do that. An air admittance valve or a vent pipe are your two options.

    • @miked1307
      @miked1307 9 месяцев назад

      @@brettleybuilt ok thank you

  • @tubingit10
    @tubingit10 Год назад

    Nice job! If the drain is inside the wall, what fittings do you use to raise the drain? I ask this bc on a new vanity, I don’t want to cut the floor of the vanity to accommodate the p-trap when I can cut into the wall and raise the drain inlet

    • @brettleybuilt
      @brettleybuilt  Год назад

      I would use a Fernco. They are a rubber connection with a clamp on either end that fits over the pvc. If you send me an email I can send you a drawing as it is kind of hard to describe.
      brettleybuilt@gmail.com

    • @tubingit10
      @tubingit10 Год назад

      @@brettleybuilt yep, I’ve used those before. I think now they are using the ones with a metal shield over them

  • @spl4shyboy269
    @spl4shyboy269 Год назад

    great vid ... was there no existing vent connected to the sink drain system already? Do I have to put the air valve on when replacing S to P ?

    • @brettleybuilt
      @brettleybuilt  Год назад +1

      There was, but the vent is after the s trap so you either need to add an air actuated vent or connect the new p trap the vent through the wall.

  • @cdcVintage
    @cdcVintage Год назад

    This video was great. Can I do this without the air actuated valve? My concern is that the valve would fail someday and gases get into my house.

    • @brettleybuilt
      @brettleybuilt  Год назад +2

      If you don't use an air actuated valve, the the p trap has to go into a pipe vent.

  • @joanguerrero3157
    @joanguerrero3157 Год назад

    Awesome video, I have a similar problem but my drain pipe is 2-1/2 would your solution in the video still work?

    • @brettleybuilt
      @brettleybuilt  Год назад

      It would if you used reducing bushings to get to 1 1/2 inch pipe and then follow the setup like in the video. Find an old guy at Lowe's who works in the plumbing department and hopefully he can find the pieces you will need.

  • @dlloytl
    @dlloytl 8 месяцев назад

    Can you make a list of the fittings so i can go to home depot to shop for thiss exact set up?

    • @brettleybuilt
      @brettleybuilt  7 месяцев назад +1

      Not to be lazy, but take a screenshot of the picture and take a picture of the plumbing under the sink and they will be able to help you out. Just make sure you ask an older guy who works in the plumbing department.

  • @ToolTalkCanada
    @ToolTalkCanada Год назад +8

    Great video, but this type of installation would not be permitted in some places, including Ontario, Canada where I live. Here, the code says AAVs must be intalled above the flood level rim of the highest fixture being vented. So I don't think an AAV beneath the sink like yours would pass code here. I have an s-trap under the kitchen sink in our 1950s home and I'm trying to figure out how to fix it without a major remodel.

    • @brettleybuilt
      @brettleybuilt  Год назад +2

      I have never heard of these ever being an issue when installed to our local codes. I hope you find a reasonably easy fix. I am going to the Calgary Stampede in the next year or two with some of my friends from Edmonton. I can't wait.

    • @thisisyourcaptainspeaking2259
      @thisisyourcaptainspeaking2259 8 месяцев назад

      An s-trap with large volume is better than a small volume. Personally, I'd use the valve in this conversion.

    • @m.b.1974
      @m.b.1974 7 месяцев назад

      Dual-seal air admittance valve is best. Thanks for the install video.

    • @don2deliver
      @don2deliver 3 месяца назад

      AAV above sink flood level most places is code. For an addition or extensive remodel only a true 'tto the roof vent' or vent tie in is required

  • @HomeownerDIY
    @HomeownerDIY Год назад +1

    I have never put pipe compound on ABS threads before, but I have heard it can disolve the ABS, have you ever experienced this?

    • @brettleybuilt
      @brettleybuilt  Год назад

      No, I have never had a problem with that and have never heard of it being a problem.

    • @b-tay2427
      @b-tay2427 Год назад +1

      @@brettleybuilt what if you have to change the valve

  • @themostexpertest
    @themostexpertest Год назад

    So I have a reoccurring slow/blocked drain and an s trap. I think it may be due to improper venting. Do you think that's possible? And would this solve my problem if the venting is the problem.

    • @brettleybuilt
      @brettleybuilt  Год назад +1

      If venting is the problem, this will absolutely fix the problem.

  • @EMo-rx7pm
    @EMo-rx7pm Год назад

    Great video. When I empty my bathroom sink, the water in the trap in my shower goes down and gas is getting back thru. You can hear the shower gurgling and then gas smell in shower but only happens when I use the sink. Any ideas?

    • @brettleybuilt
      @brettleybuilt  Год назад

      There is probably an incorrect pipe connection below the floor shortly after the sink drain or the plumbing in the bathroom is not properly vented.

  • @wwfera00
    @wwfera00 Год назад

    How would you install a p trap system in a mobile home sink that has the main pipe not on the wall, but going down on the floor?
    Would a p trap/s trap work with an air admittance valve for venting work?

    • @brettleybuilt
      @brettleybuilt  Год назад

      Can you email me and I will make you a drawing. brettleybuilt@gmail.com

  • @Skashoon
    @Skashoon 6 месяцев назад +1

    Is it necessary to extend vent pipes through the roof? Can they be run up the exterior wall of the house?

    • @brettleybuilt
      @brettleybuilt  6 месяцев назад

      For toilets and showers, yes, the pipe has to go through the roof. I would only use and air admittance valve for sinks.
      If you are considering having the pipe go into an attic or some interior space where the pipe is open and can get air, the answer is absolutely do not do this. The sewer gases will build up in the attic or open space and create a dangerous situation.

  • @sharibland4808
    @sharibland4808 9 месяцев назад

    👍👏

  • @richiestarks6163
    @richiestarks6163 6 месяцев назад +1

    That Cousin Eddie. 😂😂😂😂😂

  • @nandisaand5287
    @nandisaand5287 2 месяца назад

    Is it not correct the lenght of the straight coming off the P-trap (going into the ABS in your example) has to be at least 2x the diameter of the pipe? I saw that somewhere.

  • @Oceanbird971
    @Oceanbird971 2 дня назад

    Hi Brett new subscriber here I got an s trap in my laundry room inside where the discharge hose goes inside the standpipe are there any helpful tips to replace the pipe immediately I don't want gases coming inside my house I got niece's and nephews

    • @brettleybuilt
      @brettleybuilt  2 дня назад

      Can you email me a picture of the current setup and I will email you a drawing of what I would suggest doing. brettleybuilt@gmail.com

  • @gebwv84
    @gebwv84 Год назад +1

    I have an old farm house. S trap under kitchen sink with drain going strait downward. No vent pipe there to convert into a P. Only option is demolition of wall to install vent pipe. I may have to just keep the S. No gas smell ever so far. Home inspector missed this and no shut off valves on toilets, or sinks when I bought it. I have installed water shut off valves since. But, probably will have to live with the S under kitchen sink. Also, I am old school septic. No leach bed. Septic run off and gray water all run into old clay tile going off my property and into farm field tiles. How they did it back then

    • @brettleybuilt
      @brettleybuilt  Год назад +2

      People have used s traps for years without any real issues. If you don't notice any bad odors you should be fine.

  • @biancarose5180
    @biancarose5180 Год назад

    Where can you purchase that valve section?

    • @brettleybuilt
      @brettleybuilt  Год назад

      Lowe's or home depot. That is where I get pretty much all of my materials for everything.

  • @GaryYoung-eq1ph
    @GaryYoung-eq1ph Год назад

    Can p trap be 2 long or big!? And what can happen.

    • @brettleybuilt
      @brettleybuilt  Год назад

      Yes. If the water in the trap is too deep, the water going down from the sink might not have enough pressure to push the water in the trap quickly enough and may cause debris to settle and clog in the trap.

  • @Ezunit1991
    @Ezunit1991 Месяц назад

    If I have vents in the wall, do I still need to replace my s trap?

    • @brettleybuilt
      @brettleybuilt  Месяц назад

      If it has properly worked for years, you can decide if it needs to be changed. If you occasionally get sewer smells aroud the sink, then it needs to be changed. How the trap is vented doesn't matter as much if the water draining is causing enough suction to draw water out of the s trap.

  • @Wilburn2020
    @Wilburn2020 Месяц назад

    Is it possible to get a list of pipes used?

    • @brettleybuilt
      @brettleybuilt  Месяц назад +1

      Your situation is probably going to be a bit different. I would take a picture of your set up now and ask an old guy at Lowe's or Home Depot what you need.

  • @Justme-pe8bt
    @Justme-pe8bt Год назад

    Is there a way to install a p-trap in a limited space, a kitchen cabinet 12 inches wide? A plumber replaced the old metal s-trap with a PVC s-trap, and that's it. Now am researching

    • @brettleybuilt
      @brettleybuilt  Год назад

      Absolutely. You may just have to get creative with the fittings.

    • @brettleybuilt
      @brettleybuilt  Год назад

      If you email me a picture I could give you some suggestions.

    • @deepocean3603
      @deepocean3603 2 месяца назад

      @@brettleybuilt I have a funky plumbing situation in an old 1970's Maine homestead cabin and would appreciate some DIY advice... I will email you some pictures... Thank you so much for taking the time to make this video.

  • @fathead2705
    @fathead2705 11 месяцев назад

    Why didn't you just use 2 abs 45's and offset the abs further back into the corner? Then just use the P-trap with no unnecessary fittings? I feel like that would be much cleaner.

  • @anthonyboyes7225
    @anthonyboyes7225 4 месяца назад

    What Air Actuated Valve did you use for this project?

    • @brettleybuilt
      @brettleybuilt  4 месяца назад

      I misspoke in the video, it is called an air admittance valve. I bought it at Lowe's. It is an Oatey brand valve.

  • @hippo-potamus
    @hippo-potamus 4 месяца назад

    Well finally getting around to replacing these and Im totally lost as to what the parts I need to buy are called. You have both pvc glue pipes and other pipes that have plastic nuts. What those are called nobody fukn knows. I really wish you had a parts list.

    • @brettleybuilt
      @brettleybuilt  4 месяца назад

      Email me and I will help you out. brettleybuilt@gmail.com

  • @shyofthemoon1175
    @shyofthemoon1175 Год назад

    I'm having a real dilemma. My husband and I just bought our first house. They had the master bathroom sink plumbing going into the floor with what looks like a redneck s trap. But the pipe going from the sink into the s is smaller in diameter than the pipe coming from the floor. So the pipe coming from the sink just sits in the s trap and if the s trap fills with water it spills over into the cabinet below the sink. How would we go about fixing this? My husband is fairly handy and I'm pretty good at solving puzzles, we just don't have the money for a plumber right now and we really need to be able to use our sink....

    • @brettleybuilt
      @brettleybuilt  Год назад

      Can you email me a picture of the plumbing and I will send you a suggested diagram of what you could do. brettleybuilt@gmail.com