Oil Burner Ignition Transformer and Electrode Troubleshooting!

Поделиться
HTML-код
  • Опубликовано: 5 июн 2024
  • In this HVAC Oil Burner Video, I go over the Troubleshooting of the Ignition Failure on the Oil Fired Boiler or Furnace. We examine the Oil Primary Control, the Cad Cell, the Electronic Ignition as well as the Ignition Transformer and Electrode Placement/Adjustment. I use the Electrode Gauge Gap tool. I go over each step and give tips for testing as we move through it. Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos/Articles
    • Gas Furnace Burner Tra...
    • Oil Burner Ignition Tr...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicetech.com/store
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
    Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicetech.com/hvac-ca...
    Our Newest Articles: www.acservicetech.com/articles
    Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
    Our Other Resources: www.acservicetech.com/resources
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicetech.com/tools
    Our Tool List on Amazon: www.amazon.com/shop/acservice...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtools.com/?aff=8
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.com/show/74KXLz5...
    Apple Podcasts: podcasts.apple.com/us/podcast...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #oil #oilburner #burner #troubleshooting
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Комментарии • 151

  • @acservicetechchannel
    @acservicetechchannel  6 лет назад +2

    Tool List- www.amazon.com/shop/acservicetech
    Support- www.patreon.com/acservicetech
    For those that are looking for the tools used in the videos: (Linked Below)
    Intermittent Ignition Oil Primary Control by ICM- amzn.to/2AGvcPi
    Nitrile Gloves 100pk - amzn.to/2jG2rHS
    Cad Cell with Bracket by Beckett 7006U- amzn.to/2jGajJk
    Beckett 51771u Electronic Ignitor with "A" base- amzn.to/2ib22N8
    Ignition Transformer "Allanson 2721-628G"- amzn.to/2noADwD
    Multipurpose Electrode Gap Gauge by Beckett- amzn.to/2AqavV5
    Beckett Z2000u Gauge Kit "Z" for setting electrode gap- amzn.to/2jFuPd2
    Here is the Link for the UEI DL479 Multimeter with temp sensor- amzn.to/2jtsUbJ
    Here is the Link for the UEI DL 469 Multimeter- amzn.to/2jw4ePJ
    Here is the link for the Irwin Wire Stripper/Cutter/Crimper- amzn.to/2dGTj2V
    Here is a link to the Stanley 6 in 1 screwdriver- amzn.to/2x7NuaZ
    Other tool links can be found in the video description section.
    ACSERVICETECH is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.
    All of the ACSERVICETECH Playlists- ruclips.net/channel/UCOZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public
    If you want to support the ACSERVICETECH Channel and receive more HVACR content, check out www.Patreon.com/acservicetech

  • @kevinhalloran2378
    @kevinhalloran2378 3 года назад +1

    Thank you for the great video, I knew my Teledyne pool heater was getting fuel and air, it just would not fire up. watched the video and was able to get up and running after disassembling and cleaning the jets.

  • @paintegrity.
    @paintegrity. Месяц назад

    You told me things they never taught me after 2 training classes- Thank You! You definitely understand T-shooting unlike many Techs who are monkey see monkey do.

  • @thomasmekeel6996
    @thomasmekeel6996 5 лет назад +6

    Great video, repaired our burner myself after multiple attempts by service company. Thank you for taking the time to help us out!

  • @mrmixelplx
    @mrmixelplx 3 года назад +2

    Thanks. Best video on this subject I've seen. Concise and to the point.

  • @holgate1970
    @holgate1970 5 лет назад +2

    Many Thanks for this informative video. It saved my butt after I lost track of the wires changing out a bad primary relay.

  • @javaqen
    @javaqen 5 лет назад +6

    Great job. Very easy to watch and listen to. The video was well done and we could see all the wiring etc. We used it to troubleshoot and found that we needed a new transformer. Just finished installing it and cleaning the nozzle, screen etc and the furnace is now purring like a kitten. Thanks so much.

  • @jeffhermida4788
    @jeffhermida4788 2 года назад

    What an excellent video. Great explanation! Learned so much. Thanks!

  • @nicolasbach1378
    @nicolasbach1378 2 года назад

    ...Yep electrode was gone...needed your video...surely after powering up ...no spark at the tips... made a new one with an old one and we have LiftOff...!!! Thank You for all this...

  • @knighthvac4876
    @knighthvac4876 6 лет назад +2

    Great video as always! Love them Beckett AFG Oil burners

  • @SourDoughChef
    @SourDoughChef 6 лет назад

    Thank you for the video, it helped me get going again!

  • @WeatherNut27
    @WeatherNut27 5 лет назад +2

    @8:17 Awesome! That is not something I have seen on a video and I watched many oil burner videos. Very cool to see and understand. Thanks!

  • @CO_MP
    @CO_MP 6 лет назад +6

    Excellent video. It ALMOST makes me want to return to the east coast where I used to work on oil-burning furnaces and water heaters. I don’t miss it a bit. :)
    Funny. I had one call for an oil burning furnace not working. Customer complained entire house stunk of exhaust. When I smelled it, it was like there was a Mack truck idling down in the basement.
    Turns out customer purchased a new couch that sat very low to the carpet (very small legs). They put it over their cold air return in the family room causing a vacuum in the basement-a vaccuum pulling on the exhaust damper! We ended up having some custom legs made for the customer to raise the couch to allow air to enter unrestricted into the return. One thing I’ll never forget was how it could suck closed the door to the basement and slam it pretty hard. That’s how tight the house was and strength of the vacuum created.

  • @johnwaters123
    @johnwaters123 4 года назад

    Very helpful video. Thank you.

  • @edgarrujel3293
    @edgarrujel3293 3 года назад

    Buen vídeo, me aclaro el funcionamiento del equipo, gracias. Saludos!

  • @MegaCyberleader
    @MegaCyberleader 2 года назад

    bought a brand new one, since the one i had was basically 25 years old. And it was so well built i only had to hook up 4 hours and it was clearly marked.

  • @omgwtfits7612
    @omgwtfits7612 3 года назад +2

    If you are working on a real nasty one it’s safer to use a flare nut wrench on that fuel line. You can get a cheap imported set from any chain auto parts store for like $12 and it’s just a little bit more secure. Great video helped me a lot

  • @socialcivilian2703
    @socialcivilian2703 2 года назад

    Thanks for explaining some troubleshooting.

  • @enjoytheoutdoors1018
    @enjoytheoutdoors1018 5 лет назад

    Great explanation of your video. Thank you.

  • @saidyassin5498
    @saidyassin5498 Год назад

    Excellent Vídeo, Thanks!

  • @bc42875
    @bc42875 4 года назад

    Thanks for the video. Great info.

  • @angelperdomo596
    @angelperdomo596 2 года назад

    Great video, very instructive

  • @jcstevegigs
    @jcstevegigs 3 года назад +2

    Great video!! Thank you for the info.
    What would happen if the electrodes were set to far in front of the nozzle?

  • @kennyw7453
    @kennyw7453 6 лет назад +10

    Very good video.
    As a side note I would like know the 2 people in the world that constantly give these videos a thumbs down; unbelievable and sad.

    • @acservicetechchannel
      @acservicetechchannel  6 лет назад +3

      Ha ha, always one or two!

    • @dgmenace73
      @dgmenace73 5 месяцев назад

      Very good videos....I think some people do the thumbs down because they know its a good video and just wanna be jerks. I have only did a thumbs down on click bait videos or entirely stupid ones....lol

  • @charlesheyward5859
    @charlesheyward5859 2 года назад

    Fantastic vid !

  • @beephoon7489
    @beephoon7489 3 года назад +4

    Very good video. Please show more video on troubleshooting on oil furnace. I really enjoy watching all your videos. Keep up the good work

    • @acservicetechchannel
      @acservicetechchannel  3 года назад +1

      Thanks, will do!

    • @beephoon7489
      @beephoon7489 3 года назад +1

      @@acservicetechchannel I have refer to all my friends about your video.

    • @beephoon7489
      @beephoon7489 3 года назад

      My friends are all amazed when they watch your video. Don't forget to focus on oil furnace. Your video is very detailed in information

  • @lanceengel3741
    @lanceengel3741 Год назад

    This video saved me last year. Let's see if we can do that again.

  • @sureNuckle
    @sureNuckle 4 года назад +1

    Great video sir! Just went and tested mine like you suggested, and my spark seemed to be a lot weaker than what yours looked like. What would be the reason for a weak spark? Thank you again.

  • @buckofranco2298
    @buckofranco2298 Год назад

    Spark at the springs (alligator clip) seemed weaker than how it looked in the video, but when I performed the 'trick' at 8:15 spark at the nozzle looked fine. While I was in there I hit the conductors with steel wool. Put everything back together and it fired up. Not sure what did the trick but thank you for the troubleshooting tips.

  • @SamsungGalaxy-wy3tw
    @SamsungGalaxy-wy3tw 3 года назад +2

    Like your videos. Precise and concise without background music/noise. Do you happen to know the resistance between the two primary leads of the electronic igniter (Beckett 746001)? I bought a new Beckett electronic igniter but the resistance between the two primary leads is infinity. Is it normal? It wouldn't make sense if it were a iron core transformer but not sure about electronic transformer. The resistance between the two secondary leads (springs) is somewhere around 4 ohms, which makes sense.

  • @unclesalty7778
    @unclesalty7778 6 лет назад

    Nice video! Thanks!!

  • @ronemtae3468
    @ronemtae3468 Год назад

    Thank you extremely helpful

  • @gmrocwater9922
    @gmrocwater9922 4 года назад

    Nice Job 👍👍👍

  • @sirhc07
    @sirhc07 4 года назад

    Good video I just remove the eye when testing a transformer good tip using that clip on the ignition spring

    • @acservicetechchannel
      @acservicetechchannel  4 года назад +1

      Thanks Christopher!

    • @sirhc07
      @sirhc07 4 года назад

      @@acservicetechchannel you welcome please do more videos on oil burners

  • @acservicetechchannel
    @acservicetechchannel  6 лет назад

    If you want to support the ACSERVICETECH Channel and receive more HVACR content, check out www.Patreon.com/acservicetech
    All of the ACSERVICETECH Playlists- ruclips.net/channel/UCOZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public

  • @solarisenergy2104
    @solarisenergy2104 3 года назад +1

    Nice demonstration. well done.

  • @carloscarmo9238
    @carloscarmo9238 6 лет назад

    Great video tks

  • @jcstevegigs
    @jcstevegigs 6 лет назад +1

    Great video. I’m always so afraid to move the electrodes so I don’t change the gap. Cool to know there’s a $4 gauge on Amazon that I can buy!!! Thanks.

  • @droppindots5612
    @droppindots5612 3 года назад +1

    You ever use the "Z Gauge" to adjust electrodes..? Really easy setup..

  • @drakemilly8892
    @drakemilly8892 3 месяца назад

    Hey if I get hired I think I'm going to support the channel if I get hired

  • @christopherkanuk2546
    @christopherkanuk2546 2 года назад

    Thank you

  • @egold1006
    @egold1006 Год назад

    I installed a new transformer, non electronic model, but found issues when I used the front foam gasket.I was getting an occasional reset of the burner control. I discarded it and it has not reset since. Thinking my heating system was designed in the 60`s might not handle these newer 3000 plus rpm motors.The real problem was that my gas water heater was connected to the same flue pipe as the burner.

  • @geojor
    @geojor 6 лет назад

    great, thanks ...

  • @alreedyalrighty588
    @alreedyalrighty588 6 месяцев назад

    Great video. Does the spark need to be blue? Mine is more yellow. Would that keep it from igniting?

  • @dannyw7662
    @dannyw7662 3 месяца назад

    Good vid thnx.

  • @corbana4743
    @corbana4743 Год назад

    Thanks

  • @billsmith1008
    @billsmith1008 4 года назад +1

    I am thinking of using an oil furnace transformer to create a spark for theatrical purposes. However, I would need to run something like 25 feet of cord from the transformer to where I want the spark to occur. Is this possible and if so what type of wire should be used for this?

  • @dlinberg7561
    @dlinberg7561 3 года назад

    I measured 30 volts where the thermostat connects to the Honeywell R8184G relay control. Does the transformer that controls the furnace blower supply power to that Honeywell R8184G or is does a different transformer supply power to it? My heat pump is controlled by a different thermostat. Was wondering if I need to run one wire from the heat pump to Honeywell R8184G to pull the relay in so it turns on the oil furnace when it's to cold for the heat pump to operate? Also assuming the transformer that supplies power to heat pump thermostat and heat pump controls also supplies power to the Honeywell R8184G?

  • @mattfoley6082
    @mattfoley6082 Год назад

    My 30 year old burner was shutting down every few days and sometimes would take several seconds to ignite. Could not figure out why. Good oil flow, new nozzle and electrodes. Replaced old transformer with a new Beckett electronic igniter for $50. Problem solved! Now she fires up instantly. The electronic igniters have much higher voltage.

  • @kyleh1974
    @kyleh1974 4 года назад

    Beckett makes a tool called the z gauge now that allows much easier electrode adjustments.

  • @tbirdpimp07
    @tbirdpimp07 6 лет назад

    Lavinmoniere always wears gloves also he rattles a screwdriver in the retention head next level!

    • @acservicetechchannel
      @acservicetechchannel  6 лет назад

      Thanks tbirdpimp07!

    • @bradybell6129
      @bradybell6129 5 лет назад +1

      Too bad that he mumbles instead of talking clearly like this guy.

    • @marksteven3534
      @marksteven3534 5 лет назад +1

      But; WHY does he wear gloves ??

    • @joequillun7790
      @joequillun7790 2 года назад +1

      @@marksteven3534 I'm 65, been a jet eng. mech my whole life, and can't stand those stupid gloves. (Like taking a shower in a raincoat). I remember when they came on the scene...maybe 15-20 yrs ago? Money is being made, is why they're being promoted. (Like wearing these stupid masks.) If your hands get dirty, when you're done, wash them with Go-Jo. W/O gloves, at least you can feel what you're holding, and don't have-ta worry about pinching them. But I'm sure there are those who don't like dirty hands. I call it the "pussification" of America. (But hey, that's just me. What do I know.)

  • @chipper442
    @chipper442 4 года назад +1

    Does the transformer/spark stay active during the burn cycle, or just long enough for the spray pattern to ignite and be recognized by the cad cell? Thank you.

  • @chrisscinto889
    @chrisscinto889 5 лет назад

    Do you have an in depth video on burner heads and air tubes?

  • @SotS1689
    @SotS1689 5 месяцев назад

    Thanks for the video. The spark I am getting from my contact springs is very small. My furnace usually runs, but periodically won't start unless I press the reset button. Any idea what the issue could be?
    I've cleaned the nozzle and checked the electrode position - both seem fine.
    My contact springs do seem somewhat corroded though, could that be causing it?

  • @wetdewlap8741
    @wetdewlap8741 6 лет назад

    Great video!! I was hoping you could lend your expertise in a little dilemma that I have had this passed Thursday... so I called my oil company to come and do the routine maintenance of cleaning the furnace, changinging thr filter.. etc?Was quoted 149.00 for the routine maintenance.The technicncian told me I needed a new igniter.. that mine was weak... I agreed and the final cost was 450.00. My heat was then turned off because it was a fairly warm day.. had dinner, went to do dishes and BAM... we have no hot water now( our hot water is powered by the furnace just as our heat is). So now I am freaking out.. fast forward a few hours and it’s grtting a bit cold in the house so I turn the heat back on... go to do dishes after dinner and low and behold I have hot water again... now I am thinking wth?? So just to see if I’m not going crazy I turn the heat off again and sure enough I have no hot water again. I did this three more times just to rule out any weird coincidences and to reassure myself I am not crazy.... I’m not... well maybe a little but on this particular subject.. I am not.. so .... I call the company back and tell them , hey.. had some work done to the tune of almost 500 bucks and now I have no hot water unless I turn my thermostat up to 65 to kick on the furnace... I have never had to do that before in a year and a half to be exact.. so whatever the technician did... something went wrong.. obviously I don’t want to have to turn my heat on during summer to get hot water.. they are sending someone on Monday.. but now I am feeling a little distrustful and would like to know if you have any idea what this could be. As I said during summer our thermostats is off... never have I ever had to turn it up to get hot water.. please help if you have any suggestions.Thanks so much for your time..

    • @acservicetechchannel
      @acservicetechchannel  6 лет назад

      It sounds like possibly the control for the boiler is now changed and instead of always keeping the water jacket at 160-180 degrees all the time, it only turns the burner on when heat circulation is required. That is if I am understanding correctly, thanks

    • @mongoslade2325
      @mongoslade2325 5 лет назад

      They turned the low limit all the way down, turn it back up to 160, next level

  • @Jaysonthomas128
    @Jaysonthomas128 5 лет назад

    I was wondering if you could answer a question. My weil mclain boilers primary controller doesn't supply enough power to the blue ignition wire. (.3 of an Amp) motor, selenoid both have 120 and cad cell is disconnected. Is there anything that may prevent power from going through the ignition wire. Also is it safe to use a intermittent primary controller which combines the motor, oil valve selonoid and ignition wires together instead of a controller that activates them separately. (temporary fix) Thanks in advance.

  • @jcstevegigs
    @jcstevegigs 5 лет назад

    My tenant says the furnace is making a “womp, womp, womp, womp” sound before infighting? I’ve yet to hear it when I’m there. She said it usually happens 1st thing in morning when she turns the heat up. Any ideas what could make that sound? I changed nozzle and filter today. Seems to run just fine.
    She said the noise sounds like a washing machine? Weird

  • @tommurphy116
    @tommurphy116 2 года назад

    Any thoughts on what would make the transformer spark go away intermittently? When burner starts to stumble i Iift the transformer slightly off of the springs and there is no arc from springs to electrodes. I cut power at wall switch. If I don't cut power primary control will trip. Changed primary control and transformer and cad.Thoughts?

  • @donaldbakerakathedonaldaka5261
    @donaldbakerakathedonaldaka5261 Год назад +1

    Instead of disconnecting the CAD cell wires or putting tape on the eye, simply pull the eye from its socket

  • @x.y.8581
    @x.y.8581 3 года назад

    I get a spark without disconnecting one of the cad cell wires. Right now my furnace will not run and the reset button is not working (is not "popped" out - pushing it does nothing).

  • @HandsONreviews4u
    @HandsONreviews4u 2 месяца назад

    My relay doesn’t have a wire attached to the T T…..and keeps tripping off at times. At times it trips off, but stays on for two or three days that my relay does not have a wire connecting to both T and T does it need it in order to run correctly?

  • @Aviator168
    @Aviator168 4 года назад

    My oil water heater recently has a problem. It does not turn on when the water drops to certain temperature. But when I press the reset button, it turns on and will heat the water to the preset temperature and only does it once. I am suspecting the aquastat is not working propertly. Am I right in this regard?

  • @Drottninggatan2017
    @Drottninggatan2017 3 года назад +1

    Does this mean that the electrodes are sparking at all times as long as the burner is burning?
    I thought that the spark only ignited the flame and then after some 15 seconds it stopped sparking.

    • @robsterlobster6068
      @robsterlobster6068 Год назад +1

      That's correct, it is the primary control that tells the transformer to spark! Once you achieve combustion with atomized fuel / air mixture the spark is no longer needed.
      The motor shuts down and the control goes into reset if the cadmium sulfide eye fails to see sufficient light. This means that if the flame is dirty enough it will shut down due to poor fuel / air mixture.

  • @allensooter8429
    @allensooter8429 5 лет назад +2

    You did a good test to show a good igniter, but you have failed to show how to test for a no spark from the igniter. Could it be the controller or the igniter, how do you tell.

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад

      Hey Allen, there is only two wires going into the spark module or spark transformer. If you have power in but no spark across the alligator clip when testing when the cad cell is covered then it is a bad spark module or spark transformer, thanks

  • @BriZentTiZo
    @BriZentTiZo 3 года назад

    What does it mean if I can get it running by smacking the top cover of the burner?

  • @Scandal929
    @Scandal929 Год назад

    Would an ignition transformer work sometimes and not others? I've had 3 HVAC companies come out for an intermittent shutoff, no error codes on the control box. One suggested a thermostat, replaced it but the problem reoccurred. Another changed the blower motor and fan assembly, the problem still persists. It sometimes short cycles and other times runs for days with no issue. Any thoughts?

  • @shaheenalam9967
    @shaheenalam9967 5 лет назад

    Please i need help. My boiler ignition pump not getting signal from plc and showing trip, sequence failure. What should i check. Thanks in advance.

  • @Dmanbbb
    @Dmanbbb 4 месяца назад +1

    Help me set my airflow. I've got .75 70B nozzle, what should the airflow be set at 1-10?

  • @chrisboucher9916
    @chrisboucher9916 3 года назад

    is tt a dry contact up to the thermostat ? tried putting ac on an oil furnace and i get no fan and my contacter is not closing help

  • @capitolrefrigerationheatin7501
    @capitolrefrigerationheatin7501 6 лет назад

    do the spark electrodes need to have points on them? I see a lot that dont and it still seems to ignite oil

    • @acservicetechchannel
      @acservicetechchannel  6 лет назад

      As long as they are meeting the spark gap then the electrodes are fine with or without the points, thanks Capitol!

  • @thewitters9846
    @thewitters9846 2 года назад

    Do the springs need to touch the electrodes

  • @796andy2
    @796andy2 5 лет назад

    completely broke and have no heat , 17 f tonite ... have good flame but wont stay running , any way to jump out cad cell so stays on ?? i know, i know .... ill keep an eye on it . have no other options . starts and runs good , shuts off after 30 seconds or so , everything else seems fine ...

  • @genebohannon8820
    @genebohannon8820 2 года назад

    Do you need to borrow a set of wrenches?

  • @kathiebrown7939
    @kathiebrown7939 5 лет назад

    What would cause oil getting into the transformer cavity?

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад

      That could be a loose connection or blow back when the blower shuts off. I would call a service tech if it is not just the loose connection, thanks

  • @jayfox5
    @jayfox5 4 года назад +1

    What ever that box is called with the reset button mine seems to be clicking more the normal like a solenoid clicking noise last night the heat was off I tapped on the box and the heat went out I’m assuming the contacts might be bad what’s that box called ?

    • @lindalewis4380
      @lindalewis4380 4 года назад

      Mine is clicking now, too, after years of my heat sometimes never turning off.

  • @texasflood3165
    @texasflood3165 Год назад

    Struggling with mine now..tripping out at least once a day…frustrating

  • @funny12reddog
    @funny12reddog 4 месяца назад

    My oil furnace shuts down and black smoke rolls out by ignitor assembly. it does it intermittently. Help? We replace nozzle but not sure size is correct, changed air filter, oil filter, and fire looks good.

  • @xavierzambrano3158
    @xavierzambrano3158 6 месяцев назад

    Question. My oil furnace runs for a day or 4 and then goes to lock out. What donu suggest to trouble shoot this?

  • @plucy470
    @plucy470 6 лет назад

    Never saw a guy put the buss bars on the tranformer for a test. Don't you need the fan blowing the spark into the spray?

    • @acservicetechchannel
      @acservicetechchannel  6 лет назад +2

      You can blow on it but we are just testing to make sure that there are no cracks on the porcelain, thanks

  • @JasonTylerRicci
    @JasonTylerRicci 5 лет назад

    Can't find solution : Riello F40 oil boiler starts (air, fuel, spark) yet only runs for 1-2 secs. Then upon second attempt (ignition) it stays running fine. Sometimes, it takes a third attempt to run properly. Sounds like the flame goes out almost instantly.

  • @j.christopherlindsey8933
    @j.christopherlindsey8933 4 года назад

    Yep, learned the hard way to not use a meter/test leads that aren't rated for the voltage. Meter and leads were fine afterwards, but I received a physically unpleasant sensation. "OKAY, not doing that again!"

    • @acservicetechchannel
      @acservicetechchannel  4 года назад

      Yeah don't try to measure it, just check the gap by placing an alligator clip on one spring or clip with the power off and then disconnect one cad cell wire to test spark, thanks!

    • @j.christopherlindsey8933
      @j.christopherlindsey8933 4 года назад

      @@acservicetechchannel Several other things leading up to that "snake bit" furnace story, but the moral is "don't get frustrated and do something stupid." I've never felt a meter buzz and be shocked through the leads before.

  • @Ajcruz913
    @Ajcruz913 8 месяцев назад

    Can't the cad cell eye just be removed or would that not work?

  • @jcforever6671
    @jcforever6671 5 лет назад

    Good video but the easiest way to do it is to just turn on the furnace and as soon as as it turns on open the cover and with a well insulated screwdriver check for spark On a Becket oil burner you have 15 to 45 seconds Ignition trial before it shuts off on safety well enough time for you to have a screwdriver and just check for spark no need to disconnect the primary control But that's just me everyone has their own ways but other than that nice video

    • @acservicetechchannel
      @acservicetechchannel  5 лет назад +3

      Yeah, as a teacher of 15 year olds and up for HVACR, I just try to teach everyone the safest possible way to do things so their hands are not in contact with objects that are powered in case there is a mistake, thanks

  • @TheSugardaddy44
    @TheSugardaddy44 5 лет назад

    How come when I test my transformer I don’t remove the cad cell and it still arks

  • @chadman9482
    @chadman9482 6 лет назад

    While running My oil furnace keeps shutting off for a second and restarting. Do you have a guess on what’s going on?

  • @gabrielvelasquez1754
    @gabrielvelasquez1754 Год назад

    Why is there a short (jump) across the thermostat terminals?

    • @jcorava
      @jcorava Год назад

      It is to simulate calling for heat. If you're burner is hooked up to your boiler and you have your thermostat connected and calling for heat then you should not need to do this jump.

  • @boostmobile2622
    @boostmobile2622 5 лет назад

    Mine is not getting power to the pump

  • @matthewotremba9230
    @matthewotremba9230 4 года назад +1

    i use my tounge

  • @oilburner9989
    @oilburner9989 3 года назад

    Dude, you had the tip of your index finger all over the face of the nozzle, therefore contaminating the nozzle orifice. That's a big no-no, bro!

  • @PM-zu3cz
    @PM-zu3cz 4 года назад +1

    Just use an insulated screwdriver.

  • @subhendudas8507
    @subhendudas8507 5 лет назад

    Sir
    Hindi version chahiye

  • @luissanchez4493
    @luissanchez4493 5 лет назад

    haw too clean soffa

  • @MegaCyberleader
    @MegaCyberleader 2 года назад

    me and my brother love tesla and make a jacobs latter and harvested 1 drop of eletricity it then jumped out of its container onto my bothers thigh causing him to get zapped, I asked how much you think was in that drop of juice. he said, oooh about 25000 volts lol he jumped and it burt a hole in the pant, but he was otherwise okay lol.

  • @texasflood3165
    @texasflood3165 Год назад

    No technical help on oil furnaces where i live..1 or 2 guys that’s it..

  • @jermaineb3202
    @jermaineb3202 3 года назад +1

    Thank you

  • @vanessah893
    @vanessah893 4 месяца назад

    How do u replace the contact springs on the transformer