Triton T90SR Hot/Cold Issue DEMYSTIFIED! 🔥❄️ | Troubleshooting & Fixing Guide (4K)

Поделиться
HTML-код
  • Опубликовано: 21 авг 2024

Комментарии • 44

  • @valacyo
    @valacyo 22 дня назад +1

    You saved my day man! Shower was running only on the hottest temperature, working like a charm now, Thanks a mil!

  • @novarekify
    @novarekify 6 месяцев назад +3

    Well done. I really appreciate time you put to make this video.

    • @no-sparks
      @no-sparks  6 месяцев назад

      Thanks a mill! Glad you like it

  • @richardotoole6983
    @richardotoole6983 3 месяца назад +1

    That video was top notch. I have installed many from new but its great to get a walk through on the parts inside.
    Thank you❤

  • @cooganniamh
    @cooganniamh 26 дней назад

    Thanks for posting this. We get about 3 years out of our Tritons🤬 Hopefully this will help to prolong them!!

  • @steveg4834
    @steveg4834 2 дня назад

    Great vid problem solved cheers !

  • @karljohnston7574
    @karljohnston7574 3 месяца назад +2

    fair play to you ,great video .followed your instructions problem solved

  • @James-qf3yt
    @James-qf3yt 5 месяцев назад +3

    Excellent video have to say well explained one of the best iv seen on you tube 👍

    • @no-sparks
      @no-sparks  5 месяцев назад

      Much appreciated!!

  • @VH_YT
    @VH_YT 3 месяца назад +1

    Thank you so much your video helped me fix my shower problem.

  • @poddonnell
    @poddonnell 3 месяца назад +1

    Thanks for that young man..... cleaned fliter works perfectly

    • @no-sparks
      @no-sparks  3 месяца назад

      Glad it helped 👌🏽

  • @brendanhanratty9837
    @brendanhanratty9837 3 месяца назад +1

    Great video...very easy to follow for beginners

  • @rayobrien62
    @rayobrien62 3 месяца назад +1

    Thanks man great video going to try it out tomorrow 👍👍👍

  • @SpannerAT34
    @SpannerAT34 3 месяца назад

    Very educational and helpful. I'm gonna give it a go. Shower is running too hot.

    • @no-sparks
      @no-sparks  3 месяца назад

      Hopefully it'll fix 👍🏽

  • @lindamcgough3645
    @lindamcgough3645 5 месяцев назад +2

    Great video.

    • @no-sparks
      @no-sparks  5 месяцев назад

      Thanks a mill glad it helps 👍🏽

  • @marionscanlon1
    @marionscanlon1 3 месяца назад +1

    I loved your video.
    I installed this shower when my old one broke. The problem I have is, the water pressure is not as good as the old shower. What can I do to fix this ?

    • @no-sparks
      @no-sparks  3 месяца назад +1

      The older showers T90SI had a bit more water power than the SR, not much can be done I don't think

  • @clivewuest8529
    @clivewuest8529 16 дней назад

    Thanks for a really informative video. Explained nicely how an electric shower works, and all with that lovely Irish accent you have. I have a different problem in that my Triton Trance shower (has a direct water feed,not a tank), runs boiling hot no matter what position the water flow control dial is in. If I turn the other dial to the middle position its more controllable but only on a scale of warm, so really need the other position working. As is I just have to keep dipping in and out of the shower spray so I dont scold myself. Any idea’s ? ;)

  • @blondie95405
    @blondie95405 2 месяца назад +1

    well done very good video

    • @no-sparks
      @no-sparks  2 месяца назад

      Thanks a mill :p

  • @sineadcarroll38
    @sineadcarroll38 4 дня назад

    Thanks for the video. Any idea why water would run through the shower unit T90SR without the unit be switch on. Causing what seems like airlock.

  • @Frankyfish42
    @Frankyfish42 5 месяцев назад

    Hi, thanks dude. This was Def informative. A question if I can. What in your opinion would be the best upgrade shower to replace on a replacement tank fed system like this? The family are endlessly complaining about pressure and the temp control is too fidgety. Willing to spend a decent few sheckles on this to keep them all happy!

  • @wshakesbeer7582
    @wshakesbeer7582 5 месяцев назад

    Isn't there a valve just below the commissioning switch that can be used to get rid of any air locks? mine turns to cold every couple of minutes, very informational video, i'm going to go through the filter and feed pipe from our water tank to check for blockages, hopefully solves the issue, hard to find info online as to what the problem and solution may be, thankfully we got No Sparks!!

    • @no-sparks
      @no-sparks  5 месяцев назад +1

      I'm not too sure about the valve, there possibly is but I got rid of airlocks by running with the commission link on so the water travels through without the pump running, getting the airlocks out. Yeah might be a good place to start looking for a blockage, that's the same issue we had, would run for a while then it would go cold and repeat the cycle

  • @Scharlie2011
    @Scharlie2011 2 месяца назад +1

    If the tempertaure dial starts at 12 and ends at 5 o clock does that mean the cover dial has problem or the dial behind cover. Newly installed and barely luke warm. Dial only has half the turn yours does. 🥶

    • @no-sparks
      @no-sparks  2 месяца назад

      Yes I'd imagine that's why that is

  • @keithhartnett2035
    @keithhartnett2035 6 месяцев назад

    Nice video, well explained, just fitted a new one thisevening at home, with both elements engaged and temperature up to about 3/4 (2 o clock position) it looses water pressure. It seems to operate at optimum at this, we have good water pressure supply from tank so I dont know what the problem is. It doesnt seem to heat up to max temperature?????

    • @no-sparks
      @no-sparks  6 месяцев назад

      Ahh nice! Does it get hot At this 3/4 position?
      The more you turn the bottom knob towards max heat the less pressure you will feel from the shower head.

    • @susieblake
      @susieblake 5 месяцев назад +1

      Just had one installed but even at the highest heat setting the water is only luke warm . Is there a fault ?

    • @no-sparks
      @no-sparks  5 месяцев назад

      Definitely doesn't sound like it's working as it should 🤔 did it replace an existing shower unit?

  • @MrGreen_
    @MrGreen_ 6 месяцев назад +1

    Hi yea got my t90sr just fitted but it runs but doesn’t show power light can you help .. Pressure seems abit low to comperd to old t90si it replaces

    • @no-sparks
      @no-sparks  6 месяцев назад

      That's strange, so when the shower is running there's no power light on?
      Might be one of two things:
      1-when cover was put on the bulb wasn't clipped into the plastic holder and isnt shining through the cover. Or
      2-The light cable was pulled out of its connection during installation and so the light isn't coming on.
      Regarding the lower pressure, the SR has a different pump. The SI had a brushed motor hence the louder noise and from memory, our old SI was slightly more powerful. There might be a bit of different pressure output from the SR but if it's a massive difference there might be a problem.
      When upgrading did you use the hose and shower head from the newer shower or keep the old one? This might be part of the issue but only a guess. Hope this helps

  • @Lewis4568
    @Lewis4568 7 месяцев назад +1

    Wow it’s been 2years 😮

    • @no-sparks
      @no-sparks  7 месяцев назад +1

      Stop man I know! Back on IG today too haha channel update on the way, how ye been?

    • @Lewis4568
      @Lewis4568 7 месяцев назад +1

      @@no-sparksnice seen it pop up on my notifications and I remember you, but I remember checking a few months back you went off radar, nice that your back

    • @no-sparks
      @no-sparks  7 месяцев назад

      appreciate it! Been so busy havent had a min, appreciate the support bigtime

  • @seamuskelly8612
    @seamuskelly8612 Месяц назад

    Hi No Sparks.... my t90sr is running hot water all the time even when turned all the way to cold. Any ideas why this is ???? Thanks.

    • @no-sparks
      @no-sparks  Месяц назад

      Most likely blocked filter or a blockage in the water inlet, you should notice the water pressure changing when you move the bottom dial. I'm assuming if you move the top dial to cold and it goes cold though correct? Just the bottom not working

    • @seamuskelly8612
      @seamuskelly8612 Месяц назад

      @@no-sparks thanks for the reply..... it stays hot all the time no matter where the two knobs are. Could it be limescale if so how do I clean that ??

  • @rayhughes1974
    @rayhughes1974 3 месяца назад

    brilliant video = please take shower fully apart when it inevitably dies like ours did :)

    • @no-sparks
      @no-sparks  3 месяца назад

      A days activity haha