AEG T61275AC Protex Condenser Tumble Dryer drum not turning Error E50

Поделиться
HTML-код
  • Опубликовано: 25 авг 2024
  • In the middle of a cycle the drum when the drum periodically stop turning it sometimes wont start again on its own (but will if i press the stop/sart switch) and then eventually gets an E50 error.
    When it does start I notice that immediately before starts there is a click (like a relay), but when it won't start there is no click. Pressing the start button will get the click and a start. The click appears to come from the PCB area.
    When it starts the motor works fine and whenver there is a click the motor starts.
    Conclusion: Tested motor run capacitor and seemed faulty so replacement ordered, fitted and machine just completed full cycle.

Комментарии • 5

  • @DeStMi
    @DeStMi  6 лет назад +4

    Tested 7 microF motor running capcitor and found no building resistance when swapping polarity. (Check safety steps needed re discharging capacitors) so ordered a new one and that seems to have solved problem as it's now completed a full cycle.
    Hope this helps someone else as it suprised me that the run capacitor would give these symptoms

  • @grahamoakenfull879
    @grahamoakenfull879 11 месяцев назад

    My belt needs replacing on this model - how easy is it to replace, as i assume you need to remove the drum to thread the new belt replacement through?

  • @DeStMi
    @DeStMi  5 лет назад +2

    It was the 7uF motor run capacitor I replaced on my AEG tumbler. I searched for my order and it has the description & part number "Capacitor for Tumble Dryer 1256417013" I bought from fiyo.co.uk. www.fiyo.co.uk/capacitor-for-tumble-dryer-1256417013. It's been running fine since May with the replacement capacitor for less than £10 shipped.

  • @andreasmuller4938
    @andreasmuller4938 5 лет назад

    Hi DeStMi, i have the same problem with an identical Tumbler (Electrolux TW L4 E), only click-noise, no turning of motor-drum.Do i have to replace the big capacitor mounted below the Motor (18 uF, 425-475V, Diameter ca 40mm, length ca 70mm) ?thanks & regards

  • @asrsziha
    @asrsziha 4 года назад

    E50 mean moter not turning or software promble.