Low Voltage Short on 5 Year Old Rheem Condenser, Identical To Another Recent Repair.

Поделиться
HTML-код
  • Опубликовано: 25 ноя 2024

Комментарии • 58

  • @kevinkrug466
    @kevinkrug466 2 года назад +5

    I never thought to check a short like that, I'm going to steal that and claim it as my own. Good job sir

  • @Paulie1232
    @Paulie1232 2 года назад +6

    Great catch.......

  • @bryansimon4072
    @bryansimon4072 2 года назад +2

    Experience is a good thing. Good call.

  • @charliebrewer617
    @charliebrewer617 2 года назад +2

    Really simple issue that take experience to find as quickly as you did. Good job.

  • @khx73
    @khx73 2 года назад +2

    Exact same problem on my own Trane a few years ago. Repair guys came and fired the parts cannon right away instead of intelligently diagnosing it.
    I was tired of waiting for them to order parts and play the guessing game while I ran emergency heat, so I found the fault myself. At least I ended up with ​a free spare DFC and TDR board under warranty.
    Same black tape fix, too!

  • @ggreenlee19
    @ggreenlee19 2 года назад +4

    Great find, I like how you troubleshoot problems.

  • @brandongonzalez3681
    @brandongonzalez3681 2 года назад +1

    I’ve ran into this at least 8 times in the last 3 months, for Goodman and Rheem Heatpumps. Usually the first thing I check now. I work in the South Atlanta area. Good catch!

  • @scottk0623
    @scottk0623 2 года назад +4

    Great find on that, I think the buzzards we’re hoping you didn’t use the disconnect 🤣🤣. Stay well

  • @georgesummerlin1602
    @georgesummerlin1602 2 года назад +7

    I bet I've come across 10 trane units each year with same Issue. Something we should probably look at when we install. Good video Curtis

    • @HVACGUY
      @HVACGUY  2 года назад +2

      I was thinking the same thing, because I install these.

  • @josejulian5116
    @josejulian5116 2 года назад +2

    The first one I had with a bad contactor took me forever, I was new and didn’t want to call someone and be clown of, the very next shorted one was the wires on to of suction line, I learned them pretty quick. Great job on the repair.

  • @davidgilpin5200
    @davidgilpin5200 2 года назад +3

    Nice job, Curtis. She'll have heat tonight.

  • @bobgallo3775
    @bobgallo3775 2 года назад +1

    Have seen so many Goodman/Amana units with the same problem. I used to put a piece of tubing insulation over the wires to prevent a repeat.

  • @mattbilodeau2433
    @mattbilodeau2433 2 года назад +2

    Good catch Curtis thanks for sharing your skills with us you got a big fan in California 👊

  • @davidmayes6960
    @davidmayes6960 2 года назад +3

    Had the same problem on my unit.. It fried the board twice before i found it!! And a contactor.

  • @txmade72
    @txmade72 2 года назад +6

    Great video I'm fairly new to the hvacr trade also new to your channel as well and your channel is very informative and helpful. Thanks keep up the awesome work 👍🏿

    • @HVACGUY
      @HVACGUY  2 года назад +1

      Thanks 🙏. I’m glad they help.

  • @sebastianwilson1134
    @sebastianwilson1134 2 года назад

    Nice job, I had this problem on a Daikin HP, the other day, those short testers are life saves, I've seen a lot of them do the exact same thing, now I just automatically remove the condenser wires from the tstat wires at air handler, and replace fuse most of the time it will fire right up and I head to the condenser. Contactor and pressure switch, and tstat wires rubbing on copper I check first. Won't believe how many dogs chew those outside wires lol

  • @davidcruickshank2419
    @davidcruickshank2419 2 года назад

    Another job well done sir!

  • @biblebloopers946
    @biblebloopers946 2 года назад +2

    Damn man, good find

  • @llservice3376
    @llservice3376 2 года назад

    Great find, expierence shows

  • @bobparrott8130
    @bobparrott8130 2 года назад +2

    🤓👍 Good man
    Sometimes shorts can be a bear cat to find... Nice efficent job !!

  • @corruptedbrain6
    @corruptedbrain6 6 месяцев назад

    thats why you charge on what you know. ty bro

  • @enriquehvac6004
    @enriquehvac6004 2 года назад +1

    I’ve been a tech a year now, seen this about 5 times already

  • @georgegibbs8696
    @georgegibbs8696 2 года назад +1

    Icp and Goodman are notorious for this same issue.

  • @davewolfy.5932
    @davewolfy.5932 2 года назад +1

    Great video thanks !

  • @donnellbaxter8050
    @donnellbaxter8050 2 года назад +1

    Good job

  • @Captain_Kdawg
    @Captain_Kdawg 2 года назад

    very common problem with the newer rheems. soon as they say nothing comes on/ no power to the thermostat.and its a Rheem. i will go directly to the condenser. possibly only having to go to the air handler one time.

  • @Heavy_metal_rulez
    @Heavy_metal_rulez 2 года назад +1

    nice! for whom the bell toll's! awesome video

  • @wonderhomie2011
    @wonderhomie2011 2 года назад +2

    The Rubaduski!

  • @louispierre8037
    @louispierre8037 2 года назад

    I carry Automotive wire loom the 2 wire size Just for this situation, On many of my service calls even if even if that is not the problem I'll cover the wires with wire loom To prevent any future problems

  • @tedhicks5431
    @tedhicks5431 2 года назад

    Rheem carrier goodman bard they have same problem sometimes the defrost t stat wire also at least its not high voltage and blows a hole in copper lines

  • @markadams5429
    @markadams5429 2 года назад

    I was under the impression that it was code are those disconnects to be right outside behind the condensing unit... At least it is here where I live

  • @Tacompton425
    @Tacompton425 2 года назад +2

    Disconnect that far away is major code violation here.

  • @c21meister
    @c21meister 2 года назад +2

    Most of the Goodman heat pumps have horrible wire runs and rub out

  • @MrCedmac123
    @MrCedmac123 2 года назад

    I found the same issue a few months back

  • @sknight0391
    @sknight0391 2 года назад

    Good job bird doggin' that one. 😎👍

  • @brucehux248
    @brucehux248 2 года назад +1

    Did you not check the charge , even though it was a short? Cost of call should include a charge/ indoor heat check....just saying. Go DAWGS !!

  • @tombeilman5579
    @tombeilman5579 2 года назад +1

    Can it wait till Monday ,no it’s getting down to 65 tonight

  • @jerrylockhart3069
    @jerrylockhart3069 2 года назад +1

    Crazy

  • @jerrylockhart3069
    @jerrylockhart3069 2 года назад +1

    A lot of guys would’ve condemned the board first

  • @miguelmaynez8536
    @miguelmaynez8536 2 года назад

    HEY ANY ADVICE WHAT DO YOU USE TO RECORD YOUR VIDEOS WITH JUST CAME ACROSS YOUR CHANNEL THE OTHER DAY

  • @Jon_Pearl
    @Jon_Pearl 2 года назад +1

    Booyeah! For a penny's worth of heat shrink, Rheem could have prevented that.

  • @greenhaven1722
    @greenhaven1722 2 года назад +1

    what kind of camera are you using?

    • @HVACGUY
      @HVACGUY  2 года назад +1

      I’ve recently switch to the GoPro Hero 10

  • @milotorres6894
    @milotorres6894 2 года назад +1

    Irony of time and manufacture , exactly the same , tape and zip ties , day and night always had loose leads to compressors on package furnace RTU s usually cooked them no protection on sheet metal punched holes not even deburred or supported correctly...✌️💪👍🙏🤔😔⚡🔥

  • @stephwaylonwells3218
    @stephwaylonwells3218 2 года назад +1

    👍

  • @curtm.1684
    @curtm.1684 2 года назад +1

    Do all transformers buzz like that?

    • @HVACGUY
      @HVACGUY  2 года назад +4

      Normally…As soon as I say yes, I’ll find one that don’t. But, that’s pretty standard.

  • @walterskelton411
    @walterskelton411 2 года назад

    Without past experience that would have been a right pain in the posterior to fix. It could easily have been an intermittent fault. Call back after call back :(

    • @clayevans3421
      @clayevans3421 2 года назад

      Sometimes they will only short when it rains hard! Depends on how much it’s rubbed

  • @gingerstrand6153
    @gingerstrand6153 2 года назад +1

    Go Olympics! Love me some games! Good video

    • @graymodeler
      @graymodeler 2 года назад

      Some ice skater chick did a Quad spin!

  • @steveblake8766
    @steveblake8766 2 года назад

    411 thumbs up