Flex vs. Metal vs. Duct Board: Differences and Use Cases

Поделиться
HTML-код
  • Опубликовано: 14 май 2024
  • Subscribe and follow my Podcast on Apple or Spotify!
    Apple: apple.co/32AOwgU
    Spotify: spoti.fi/3FXNg4X
    Sign up for our twice-weekly newsletter:
    buildshownetwork.com/newsletter
    To sponsor a video or advertise with us visit:
    www.buildproductions.com
    Want to learn more about building? buildshownetwork.com/
    Build Show Network on Instagram: / thebuildshow
    Huge thanks to our Show sponsors Builders FirstSource, Polywall, Huber, Rockwool & Viewrail for helping to make these videos possible! These are all trusted companies that Matt has worked with for years and trusts their products in the homes he builds. We would highly encourage you to check out their websites for more info.
    www.bldr.com/
    www.Poly-Wall.com
    www.Huberwood.com
    www.Viewrail.com
    www.Rockwool.com

Комментарии • 139

  • @danielashton5697
    @danielashton5697 Год назад +11

    As a former HVAC installer, I spent an inordinate amount of time repairing/ replacing duct board and flex duct with metal because they just don’t hold up over time and really adversely affected system performance

  • @mattp4079
    @mattp4079 Год назад +8

    Det. John McClane taught me everything about the utility and durability of metal ducting. Ever try low-crawling with a .45 and a Bic lighter through fiber board or flex?

  • @RobinBos909
    @RobinBos909 Год назад +8

    I'm a HVAC tech in the Netherlands, we only use solid metal ducting in our installations. I work with one of the few companies who specializes in air heating(/cooling) for residential buildings. Even if we need to cross load bearing beams or so, we make custom conduit in al kind of shapes and sizes. Only when there are no options for solid, we use flex. Never would we use some kind of fiberboard!

  • @CoconutPalmPictures
    @CoconutPalmPictures 6 месяцев назад +5

    I was waiting to hear about insulating metal ducts but never heard anything. How is that accomplished in an un-AC attic or crawlspace?

  • @crabkilla
    @crabkilla Год назад +6

    3:15 that is the most beautiful ductwork I have seen installed 🤩

    • @TerryKashat
      @TerryKashat Год назад +1

      Please DON’T ever use Duct Board. Ever. I put some other posts in this thread. You will see my reasoning.

  • @Anthony.Delagarza
    @Anthony.Delagarza Год назад +5

    When he said you guys know what to do, who else yelled out, “Oooooon the build show!”

  • @burtfamilyhistory347
    @burtfamilyhistory347 Год назад +4

    Just reducted an 1875 farmhouse, added vents in rooms that were missing and upgraded the return from one 4x6 in the front room to a real return on both floors. Best upgrade ever. Nice to know they’ve used the right products in the right way!

  • @DrMJJr
    @DrMJJr Год назад +58

    FOR ME, I’d do metal duct everywhere no matter what; there’s just no substitute for the ability to repeatedly clean them on a regular basis.

    • @hoopie1022
      @hoopie1022 Год назад +2

      Facts

    • @TerryKashat
      @TerryKashat Год назад +2

      100%. The other stuff is not just bad in performance - it’s bad for your health.

    • @MrElemonator
      @MrElemonator Год назад +2

      You need to replace your filter on a regular basis

    • @gregorybergere
      @gregorybergere Год назад +1

      How many ventilation systems are designed for cleaning? I gues none with flexible trunking.

    • @dannym1772
      @dannym1772 10 месяцев назад +2

      I actually just got my air ducts cleaned and did not know this. My air ducts were really old and now they completely broke them all over the place. I have to do a full replacement now since i had non-metal ducts and the cleaning company ruined them.

  • @Tom-pc7lb
    @Tom-pc7lb Год назад +10

    Always get your ducts in a row.

  • @alonzosmith6189
    @alonzosmith6189 Год назад +8

    Learn so much from this channel. I was told to stop finding issues in my house by the wife.

    • @DrMJJr
      @DrMJJr Год назад +2

      That means you’re LEARNING!! 👏🏽👏🏽👏🏽👏🏽

  • @1agaragedoorssacramento
    @1agaragedoorssacramento Год назад

    Great video Matt!

  • @1stWorldProblemsSolved
    @1stWorldProblemsSolved Год назад +10

    Good to know my older all metal ducts are still the best option.

    • @MrElemonator
      @MrElemonator Год назад

      Also good to know metal is great at transferring heat so there is a energy factor where the heat might take longer with metal ducts.

  • @ecospider5
    @ecospider5 Год назад +15

    My house had a lot of flex ducting when it was built. I didn't know this till after I had my ducts cleaned and the cleaners tore multiple of the runs going under the house.

    • @electroluxwash
      @electroluxwash Год назад

      Ouch how it wasn’t too expensive to fix 🙏🏼

    • @ecospider5
      @ecospider5 Год назад +1

      @Electrolux Wash I was able to get to all of them and fix them with tape. I do wonder if that is a hidden problem for the new owners who have been there more than a decade.

  • @xslabcabxhearsex
    @xslabcabxhearsex Год назад +3

    I have been doing HVAC/sheet metal mechanic for over 33 years.if you can invest in a custom metal duct system done by a reputable professional company.it will cost more but worth it.

  • @Smallduckenergy
    @Smallduckenergy Год назад

    Good job inacho

  • @Rocco101
    @Rocco101 Год назад +24

    Metal duct all the way , seal all seams really really well and it will last a lifetime time.
    Great video Matt
    Appreciate you

    • @buildshow
      @buildshow  Год назад +4

      Right on. Totally agree

    • @TerryKashat
      @TerryKashat Год назад +4

      100% Metal duct all the way.
      The cheaper options should not even be available for something as important as our air.

    • @jakubsebor4756
      @jakubsebor4756 Год назад

      @@buildshow that's why you used pvc duct hose in your house. Do you remember the Zehnder system?

    • @lukemarks9132
      @lukemarks9132 Год назад

      @@jakubsebor4756 what’s wrong with the zehnder ducts

  • @ddivinia
    @ddivinia Год назад +3

    How about noise concerns. Sound thru the ducts from room to room. Metal ducts has got to be louder. In that conditioned space - what is your target humidity level? Love the show, D.

  • @hoopie1022
    @hoopie1022 Год назад +37

    Duct board has no use case for being a duct. Exterior insulation sure, a duct that airflow goes through absolutely not. Way too much fiber shedding and I’ve seen way too many home owners have respiratory issues when duct board is in the home.

    • @lrc87290
      @lrc87290 Год назад +3

      I think you are talking about the old duct board with the raw fiberglass on the inside. Our 35 yr. old condo community I help manage has this horrible stuff. It is disgusting after 35 years and honest duct cleaning companies won't clean it. The board they are showing has a coating of some kind.

    • @hoopie1022
      @hoopie1022 Год назад +2

      @@lrc87290 The newer duct board does has a black liner on it which I agree is a million times better but it also starts to breakdown over time but this system they have built with the Dehus is also pretty advanced so in this VERY RARE case it might work out okay.

    • @compasteedee
      @compasteedee Год назад +7

      I agree with this 100%. It is a horrible product, even in its current iteration. It is a disposable product in a permanent application. There are plenty of other problems, such as combustion and fire conduction, and any one of them should be enough to have it outright banned. In Canada there are no building codes that allow it, from the largest producer of pulp and fiber in the world; that should tell you something.

    • @brettbret8836
      @brettbret8836 Год назад +1

      As a wellness expert who specializes in environmental toxins i can tell you that duct board is going to contaminate the air with toxic materials.

    • @TerryKashat
      @TerryKashat Год назад +2

      I can personally vouch for this.
      An office building I used to work in - I noticed I had respiratory challenges when I spent too much time there. Wouldn’t clear until a full day or two of not being there.
      After I did my own inspection - duct board everywhere.

  • @boby115
    @boby115 Год назад +12

    In my neck of the woods (St Louis metropolitan area) well over 90% of the homes are built with basements, sheet metal ductwork was always used and continues to be used to this day. Sized, supported and installed correctly sheet-metal ductwork can withstand the test of time with few problems. The problem I’m starting to see is the lack of skilled tradesmen in this field, the Legacy sheet metal men are starting to retire and die off (I am seeing less pants legs and cheeked or rounded corners used , i’m assuming the contractors don’t want to pay for the extra time or have the expertise).

    • @goobygoober455
      @goobygoober455 10 месяцев назад +2

      Over here in Lancaster County, PA and surrounding areas we mainly use fiberglass ductboard instead of metal. Not many of the guys know how to do metal anymore

  • @oldschool6798
    @oldschool6798 Год назад

    Good, to the point program. Thanks much.

  • @quacktony
    @quacktony Год назад +6

    I never knew duct board could be use to make ducts. The insulation properties were there but I assumed stainless steel pipes or flex duct was used. Good to know

  • @gerwynsamuel
    @gerwynsamuel Год назад +2

    Matt, how do mini-ducts in a high velocity small duct system compare?

  • @MrStreaty122
    @MrStreaty122 Год назад +12

    I thought it was best practice to use solid metal ducts for the majority of runs, and then flex for the last 5-10 ft if absolutely necessary

    • @goobygoober455
      @goobygoober455 10 месяцев назад

      I think code is 14 feet max for flex

  • @bquedenfeld
    @bquedenfeld Год назад +10

    43 yrs. in the HVAC business I delt with a 3 and more I would never ever use duct board in my home it's not allowed in Hospital and Schools so why should anyone want that in their home.

    • @TerryKashat
      @TerryKashat Год назад +4

      I didn’t know it wasn’t allowed in Hospitals & Schools but that simply backs up my HIGH scolding of this product.
      Shouldn’t be on the market.

  • @louiem4134
    @louiem4134 Год назад

    One of the first few to see as soon as it posted noice.

  • @erhvacramirez8023
    @erhvacramirez8023 Год назад

    For me the better way always is BUILD system or combination between metal round and flex !

  • @andrewnaber520
    @andrewnaber520 7 месяцев назад

    Hey Matt, you ever see or come across Alumaflex? Thoughts on that?

  • @georgek.5817
    @georgek.5817 Год назад +4

    Higher quality products always cost less long term

  • @EOTE_TX
    @EOTE_TX Год назад +4

    I am building a custom home with a gambrel roof. I decided to custom build my ducts out of 1" aluminized insulation board in a triangular shape fitting to the lower section of the lower gambrel of the roof. The duct is compact, and was easy to build and install. I taped it together with aluminum tape and zip tape. I also created the inlet and outlet plenums out of the same materials. I used 6" flexible duct to provide air to the registers from the second floor to the main floor ceilings. Since the home is in an "L" shape I used 12" flexible ducts between the floor trusses to transfer air between ducts on both sides of the gambrel roof. The temperature difference between different parts of the home only varies about 1/2 of a degree from day to day. Then again, because the roof is 6-1/2" PolyIso on the exterior and 6" of fiberglass batt insulation on the inside and the walls are 3-1/2" PolyIso on the outside and 6" of fiberglass batt on the inside the house varies only 1/2 degree from day to day. Coupled with an HVAC system and dehumidifier the duct work performs flawlessly. The amount of insulation ensures that the house temperature does not change significantly and the load on the HVAC system is negligible. We had a night where the temperature dropped to 9 dgrees Fahrenheit and we purposely turned off the HVAC unit overnight for 12 hours. The inside temperature only dropped 3 degrees. This is a 3800 sq. foot home with 2 floors and only a 5 ton HVAC system. I call it my big Yeti!

    • @imtheonevanhalen1557
      @imtheonevanhalen1557 Год назад

      In my area R-8 duct board is required.....2 inch. I used R-8 duct board for the 20' plenum, and came off with 6 inch flex duct. Works very well and passed inspection with no problem.

  • @joshuaellison01
    @joshuaellison01 Год назад

    We are searching for a solution to our in slab duct repair issue. There appears to be areas which are deteriorating and the spray encapsulation, like Duct Armor, seems like a good solution. Anyone have experience or feedback on this method? Replacing what's in the slab does not appear to be an option, neither is installing split units or overhead duct work.

  • @larryseibold4287
    @larryseibold4287 Год назад +1

    An end to end metal duct is loud compared to flex duct or duct board, so there is a trade off beyond cost, even if oversized a bit.

  • @DonTruman
    @DonTruman Год назад

    How do you clean ducts? I presume you have to pull it apart, then run some sort of brush-vacuum through it.

  • @patora911
    @patora911 Год назад +8

    I need the breakdown of how easy these are for ninjas to crawl through…

    • @TerryKashat
      @TerryKashat Год назад +1

      I was concerned about Solid Snake - but you make a good point too 😂

    • @redneckgoatfarmer
      @redneckgoatfarmer Год назад +2

      Sheet metal duct is the only ninja approved duct. Due to higher cost sheet metal ducts are utilizing thinner metal which can bare less weight and it is noticeable noisier. Making it much harder on ninja.

  • @townsendliving9750
    @townsendliving9750 Год назад +1

    Hydronic heat and cooling, per room home runs to cassette systems. Each room can be temperature controlled, can be installed by the most rookie DIY homeowner, easy to clean and maintain.

  • @pleasenomore100
    @pleasenomore100 Год назад

    I'm having a new home built, and I'm afraid that my HVAC contractor is going to pencil whip the DALT test on my ductwork.
    How to I keep my HVAC contractor honest with duct air leakage testing (DALT), it is energy conservation code in NC. I'm certified through AABC and performed numerous DALT tests in a commercial setting using equipment from Retrotec and Oriflow.

  • @MultiYlin
    @MultiYlin Год назад +10

    a quick question: I see Germans begin to use rigid plastic for duct work.

    • @Abdullah34610
      @Abdullah34610 Год назад +1

      My initial concern would be warping when hot. Also how porous/vulnerable to mold it is. Probably depends a lot on the material.

  • @michaelshettig7805
    @michaelshettig7805 Год назад +6

    If you're building a million-dollar house, I would get an upgrade alternate price on metal ductwork and see if it fits into your budget.

    • @terrencesauve
      @terrencesauve Год назад +1

      Well that the main problem with new homes. Many pick the kitchen upgrade or the third bathroom over insulation and better HVAC. You only want to pay for what you see, not what comes out of your pocket every month...

    • @hotrodpaully1
      @hotrodpaully1 Год назад +1

      If you're building a $1000 dollar house I still would use metal

  • @jaxchristian6408
    @jaxchristian6408 4 месяца назад

    Flex duct most common because easiest and cheapest to install. Easy to crush crawling around in the attic

  • @juligrlee556
    @juligrlee556 Год назад +4

    Does anybody know the physics of sizing metal ducts to best guide heat from the furnace to the extreme other end of a series of rooms at distance from the source? Discussion of products without proper location and sizing is at least as important as materials. Also, what options you use to insulate your metal pipes has a lot to do with efficiency, especially when the furnace is downwind of prevailing winds outside winds or thermal issues in walls. Everyone believes they are the perfect duct system designers although they know little about volume of moving air inside of the ducts themselves. Additionally, where to place furnace outflow to rooms and where to place cold return is the field of HVAC designers for each room. There is a lot to know in planning your HVAC ductwork and very few qualified HVAC flow designers capable of providing even heat to a 3 BD house with large living quarters, entertainment centers, office space, play room etc.

    • @kellyhutson8988
      @kellyhutson8988 Год назад

      Good point, that's why engineers make the medium bucks.

    • @terrencesauve
      @terrencesauve Год назад +2

      That's why we use hydronic heating and mini split a/c. Theres so much head loss moving air through joist space that it doesn't make sense anymore. We used to only have hydronics half a century ago, why not go back to systems that still works 50 years later. All these shitty lined cardboard will have to be ripped out in 20 yrs.

  • @Casmige
    @Casmige 4 месяца назад

    Wow!, Nacho certainly has his ducts in order…!

  • @1oldbluesheepdog
    @1oldbluesheepdog Год назад

    Is the metal ductwork insulated or does it have to be in a controlled space?

    • @kellyhutson8988
      @kellyhutson8988 Год назад +1

      It comes uninsulated but can be wrapped in insulation if used in an unconditioned space. You just have to check the insulation type and specs for the space you're using it in and make sure it's installed correctly.

  • @Regnarrussell
    @Regnarrussell Год назад +2

    My home has duct board and flex duct. It’s horrible and I will swap it out for metal. I may even spray foam the surface to insulate.

  • @Jameson4327
    @Jameson4327 Год назад +3

    You haven’t put out a video on cleaning ductwork. I just cleaned my house and I was shocked at the amount of dirt,hair? whatever.

    • @hoopie1022
      @hoopie1022 Год назад

      ruclips.net/video/bWCr66fX_k4/видео.html

  • @danielstoscup755
    @danielstoscup755 Год назад +1

    Hey guys I have a 30 year old house with metal ducting and I hear it creak and pop every time my furnace kicks on and off. I assume it’s from the metal expanding and contracting, any advise for how I can fix it?

    • @hoopie1022
      @hoopie1022 Год назад +1

      Sometimes you can find the spot that pops and just stuff foam or insulation around that area to keep it tight…I know that’s a gangster recommendation but it’s the easy cheap option. If you want the expensive option get new duct that is thicker metal.

  • @kenreynolds1000
    @kenreynolds1000 Год назад +1

    Corrugated pipe kills flow. Anyone who has studied head loss will tell you round and smooth is best. Sharp corners are bad too. Hard to do and mostly overcome with more horsepower.

  • @hoopie1022
    @hoopie1022 Год назад +2

    And you can clean flex duct as long it’s not brittle.
    You can clean and incapsulate lined ductwork or duct board according to the IICRC and NADCA standards per the NADCA ACR 2013

  • @macoveialex6823
    @macoveialex6823 Год назад

    What about HDPE?

  • @loctobert9421
    @loctobert9421 Год назад +1

    Love that "Tesla" has become equivalent to "High-end" or "Great quality".

    • @turbo3922
      @turbo3922 Год назад +2

      Yeah that doesn't make a lot of sense to me. There are plenty of other cars that are better known for build quality and high cost. Tesla has a reputation for poor quality control (big panel gaps, misaligned parts, etc).

    • @02au17
      @02au17 9 месяцев назад

      ​@@turbo3922true but non car people probably dont know that

  • @dsdragoon
    @dsdragoon Год назад

    The best ducts are the ones running throughan air condition attic space.

  • @williammauzy7918
    @williammauzy7918 Год назад +3

    Metal duct work everywhere, sprayed with foam. Only way to go.

    • @TerryKashat
      @TerryKashat Год назад

      100% Metal Duct. I would advise against the foam and use sealing tape. It’s healthier from a biological standpoint.

    • @audreye7078
      @audreye7078 Год назад +1

      @@TerryKashat insulation?

    • @TerryKashat
      @TerryKashat Год назад

      @@audreye7078 the foam is not biologically healthy from a chemical standpoint.
      Insulation is technically fine - the challenge wise that is you want NO fiberglass insulation exposed to the air leaks or interior of your duct do that the fiberglass never gets in the duct pathway.

  • @Loadrunner620
    @Loadrunner620 Год назад +1

    Flex duct always installed incorrectly 60% inefficient.
    Fixed metal duck is the best.
    Avoid ninety-degree turns elbows. Use a slight curve elbow. Insulate around the metal

  • @frankminisplitking
    @frankminisplitking Год назад +3

    Wouldn’t it be cool, no pun intended, if there was an in-between board and sheet metal… I think as systems get more efficient and complicated… why haven’t we come up with something better? An “in between” would be awesome, as more people care about the “lungs of their house” and their investment. Obviously it would be great if we can use the same tools we already use for duct board… but a smoother, more resistant finish on the interior… maybe a neoprene layer, call it duct board pro…

    • @tonycosta2455
      @tonycosta2455 Год назад +1

      Double wall metal ductwork. Very expensive but, you get an inner liner of metal a inner layer of insulation then an outer metal layer.

    • @frankminisplitking
      @frankminisplitking Год назад +1

      @@tonycosta2455 I’m sure that’s more awesomeness, but looking to offer an in-between metal and duct board for the budget minded. I saw someone post about plastic something from Germany, sounds interesting… hopefully we can use the same tools!

    • @1hiphopnow
      @1hiphopnow 9 месяцев назад

      Even if there were the experts would advise against it cuz it’s not 100% 🤷🏼‍♂️

  • @1galste
    @1galste 5 месяцев назад

    after several test of air flow the amount of gain of metal is not justified by the higher cost. Also with time the metal duct became noisier. Last consideration is that if you put a piece of flex along a metal built system the efficiency people is talking about is really less, even using a short amount o flex. Metal is better but it is not all gold as they say.

  • @concreteguyjd
    @concreteguyjd Год назад

    What, no FRP ducts?

  • @gordonlee5761
    @gordonlee5761 Год назад

    I use rigid galvanized steel for most parts of my ductwork. I only use duct board for return air and registers, connecting with 7ft long flex ducts for noise control. I have a MERV13 media filter and a whole house dehumidifier system so I don’t think it gonna cause IAQ issues.

  • @moabfool
    @moabfool Год назад +1

    The loss of velocity alone is a good reason to never do flex. Metal or don't bother.

  • @tullgutten
    @tullgutten Год назад +2

    Flex should be illegal for any closed space like in wall or attic as it is garbage for air flow, it collects dust innside that leads to mould and is impossible to clean after some years without destroying and need to replace it all (it is really a 5 to 10 year max product before replacement is needed/reccomend.
    Steel is great for everything except working with it as it takes more time but as long as it doesn't get water on it it is a 100 year product that only needs inspect/clean for dust now and then and it is easy clean, will not get damadged from cleaning at all, fire resistant (still a fire hazard if flames get into it without any fire dampener) it is silent since it is smooth and heavy.
    The foam board one i haven't seen before but it should have many of the same benefits as metall just not nearly as easy to clean

    • @tullgutten
      @tullgutten Год назад

      As a homeowner and doing full renovation on my house im going for steel duct in and out to my HRV with aluminium semi flex expandable duct the last meter for long bends and it is also a "lifetime" product.
      Half meter flex out from the HRV to give easy access for cleaning and it all being in a "closet" for easy access to replace only used for noise reduction.
      Then steel and possibly semi flex Aluminium the rest.
      Still making it so not done. but i am limiting plastic flex only to 1 meter to and from the HRV since it is some thin flimsy shit only for vibration free connection.
      Also going to hang the HRV on acoustical spring hangers to isolate vibration from the house frame (not any noticeable vibration tho as it is not the rotating ceramic core type

  • @gregorybergere
    @gregorybergere Год назад

    It is worrying how much of a new house is made up of complex chemicals, especially plastics in many forms. Do we know what is slowly leaching out over the years into these tightly sealed boxes? We usually only find out after people get sick.

    • @cosmicallyderived
      @cosmicallyderived Год назад

      There’s an air exchanger Matt likes to have installed. Fascinating devices that balance pressure and cycle air. Air still comes in but heat and cold is dealt with and particulates too.

  • @Ed-jg3ud
    @Ed-jg3ud Год назад

    Is it me or is the audio on this seem weird and kinda off? Like they re-recorded after the fact and dubbed it in?

  • @winkel08
    @winkel08 Год назад +3

    I would strongly discourage the use of duct board due to poor air quality

    • @lrc87290
      @lrc87290 Год назад

      See my answer above

  • @nathanmrudd
    @nathanmrudd Год назад +1

    Good content, but I demand more than 5mn. 😂

  • @wendellsatterwhite50
    @wendellsatterwhite50 Год назад +4

    Why couldn't you use PVC?

    • @mitchdenner9743
      @mitchdenner9743 Год назад

      You could if your independently wealthy.

    • @stephen7938
      @stephen7938 Год назад +1

      Static charge build up, possible fire hazard.

    • @shannabolser9428
      @shannabolser9428 Год назад

      I've seen it used for underground system

    • @wendellsatterwhite50
      @wendellsatterwhite50 Год назад

      Didn't Matt have a show where it was used in an underground system in a house in Colorado?

  • @TerryKashat
    @TerryKashat Год назад +11

    Matt - I highly suggest you highly advise against Duct Board and advise against Flex Duct.
    These things are cheap and cause respiratory issues due to the fiber glass insulation entering your space.
    Additionally - the porous nature of Duct Board allows for moisture build up and mold. Go look at any installation and you WILL FIND MOLD on the Duct Board and that gets injected into your air.
    I speak from personal experience.
    It should have never made it to market.

    • @terrencesauve
      @terrencesauve Год назад +3

      These are great points. Carrying out or moving moist air with lined cardboard is just a terrible idea.

    • @goobygoober455
      @goobygoober455 10 месяцев назад

      Fiberglass duct is pretty resistant to moisture unless you pour water on it when installing or leave it in the rain

    • @TerryKashat
      @TerryKashat 10 месяцев назад

      @@goobygoober455 and when there is a leak in the cieling? Or major humidity challenge in the building. Game over - both things happen and it is hard to detect once installled.

    • @drunkennewfiemidget4251
      @drunkennewfiemidget4251 8 месяцев назад

      This is just straight up wrong.

  • @duanehundley
    @duanehundley Год назад +1

    Which one is the quietest?

    • @winkel08
      @winkel08 Год назад +1

      Using flex is the quietest I would only use duct board if necessary given you live close to the ocean and concerned with the main duct rusting out otherwise use metal for main duct and flex going to vents if you use all metal it's a good bit noisier you can do 3 to 5 foot of flex and the rest metal going to the vent

    • @hoopie1022
      @hoopie1022 Год назад

      I think lined metal is quieter than anything but duct board is pretty quiet

    • @kenreynolds1000
      @kenreynolds1000 Год назад

      Anything to decouple a solid pipe vibration to the vent. That’s why they use a short section of flex.

    • @winkel08
      @winkel08 Год назад +3

      That may be true but I don't care for lined metal bc of the fibers in the insulation their is a reason hospitals don't allow lined metal or duct board in their facilities

    • @WastedBuff
      @WastedBuff Год назад +1

      @@winkel08 Just added a note for my builder to do exactly this based on your comment. Thanks!

  • @TinyGiraffes
    @TinyGiraffes Год назад +1

    Their Mic's sound off. I've heard Matt enough to know the higher parts of his voice aren't getting recorded. (It's happening on all of them; so I doubt it's intentional.)

  • @edwardlucero9665
    @edwardlucero9665 Год назад

    😂 only if this were a real message. You notice it is a message recording, not even sleepy Joe would leave a voicemail.😂

  • @1hiphopnow
    @1hiphopnow 9 месяцев назад

    So duct board and flex is useless ✍🏻 steel it is

  • @oatlord
    @oatlord Год назад +1

    "Equates" or rather "e-queets"

  • @ridiculous_renovations
    @ridiculous_renovations Год назад +3

    Duct board where it's appropriate for only a 20% bump in price of the ductwork seems like a no-brainer.

  • @tjrooger1092
    @tjrooger1092 Год назад +5

    This is all a bit misleading. When a HVAC system is installed, there's a duct flow calculation done. It doesn't matter what the % reduction is. The ducts would be upsized if the loss was significant enough to matter. Like you'd use a 7" flex instead of a 6" metal. The double the cost must just be for materials only. The labor alone is probably 5 times. Flex duct can be a 20+ foot run without worrying about seams.

  • @virgil3241
    @virgil3241 Год назад +2

    New builders using flex duct should be sued and then banned from building. Cheap and fast is the only reason they do it, and then charge a normal price or more anyway. Should be banned from building, since they probably hide it as well from home owners that dont know any better

  • @TerryKashat
    @TerryKashat Год назад +1

    Flex Duct and even worse Duct Board have NO BUSINESS being used. They should be banned - taken off the market. It’s so cheap and so BAD for you in any application. I speak from personal experience on Duct Board.
    Nobody is ever going to replace them once installed.