what are neutral section of overhead equipment in railway
HTML-код
- Опубликовано: 18 окт 2024
- Dosto es video me OHE k overhead equipment ke neutral section k bare me bataya gya hai....Hog wale locomotive es section ko cross karte hai to unhe supply kaise milti hai...sab janane k liye video ko pura dekhiye achha lage to like kijiye share kijiye
Credit of video clip given to:- TC Rail - Наука
Extremely remarkable info. Admin, you are doing an excellent job buddy..
आपके द्वारा दी गई जानकारी अनमोल है।आप जब भी किसी विषय पर वीडियो बनाते हैं ,तो उस विषय की विस्तृत जानकारी देते हैं।ये मुझे बहुत अच्छा लगता है और आसानी से समझ में आ जाता है।आजकल इस तरह से समझाने वाला व्यक्ति मिलना बहुत ही दुर्लभ है, वो भी मुफ़्त में।
I didn't understand why someone are disliking this video.. who gives such a good information about railways like this channel..
Great videos Har Video ke saath kuch naya sikhne ko milta hai. Thankyou for your efforts.
Sir, you give real important information. I am a Mumbai local commuter and all the questions I used to get, you have answered them and many more. Thanks and please keep up the good work.
Itni acchi jaankarikeliye aapko bahut bahut dhanyabad.
Excellent video. I have so often looked at the OHE from the train window and wondered these were. Thanks! I look forward to more such videos. One question from my side: I have heard that there were dead sections in CR zones when the loco such as a WCAM2 used to move from DC to AC sections. Were they similar to these neutral sections as well?
Yes....one side ac another side dc....
Sir apke saare videos bahot acchche hote h... Just worth it
Thank you so much bhai...mai iss neutral section ka information bahut dino se dhund rha tha.
Sir kya gajab ki knowledge dete ho aap hume ,dhanyawad aise hi rochak jankari dete rhiega , Railway ki kitaab ho aap
Thank you.....
Waah bhai kya khub knowledge knor hai jaisa naam sakta kaam supeb bhai bahut tarakki milni chahiye
Nice info bro.... Bahot khoob... Ye pehli baar hamko pata chala hai....Thancuu so much
Excellent, itna easy method se samjhaya gaya.
Uninsullated overlapping of OHE ruclips.net/video/XmFSym51wYM/видео.html
Sir very nice video I saw whole video sir you are great!
Neutral section overhead equipment diamond crossing pe hai jab train is line se gujarti hai tab train ke locopilot pento down karte hai jab locomotive neutral section se niklane ke baad phirse pento raise karke locomotives running mode pe karte hai.
Main railway functions aapse sikha hai. Aapka bahut Dhanyawad 🙏
Gzb knowledge hai.... Bhai..... Very good
Nice Video Puri jankari Mili AAJ...😊
Good information,mai bhi yhi soch rha tha ki itni lambi line ko alg alg jagah se current deta hoga
T-scott transformer nhi use karte kya 3phase to 1 phase karne ke liye
Sir iska matlab har 40km mai pantograph ko niche kiya jata hoga lekin raat mai driver ko nhi pta chla to uske koi major problem ho sakti hai
Very effective and informative video..thanks..
Ap best of one RUclipsr ho
Acchi video bhai , helpful knowlwdge bhai
Fantastic explaination sir. This is indeed useful information
Sir High speed train eg bullet train
Unme bhi aisa hi system hota hain ??
Buller trains are running very fast. for every neutral section, will they have so much time to Stop cut supply totraction in very High speed ??
In the sides of track there are single phase transformers plss make a video on these too..,..thnx for sharing ur informative videos
Ankit Kumar
Those are AT auxiliary transformer s
For local supply like station premises etc.
Ravinder Kumar thnx first of all for your response
By the way what is AT
Ankit Kumar
Actually OHE works on 25 KV
But you know our local appliances like fan, lights, announcement system etc. at platform area runs on 220V as in our homes.
So for that purpose AT (Auxiliary Transformer) is used,; for 25kv-220v
Ravinder Kumar thnx sir keep on adding more videos
Ankit Kumar
No No; I don't make and post video regarding this. Actually when I watched this video I found that it is required some more fact so I replied.
As I'm Senior Section Engineer in OHE Railway
Mind-blowing bhai..mja aa gya
When tracks are changed are there ohe wires for electric locomotives ?
Bahut informative vdo
if possible, iss topic ko thoda aur detail mein nxt vdo mein explain kariye.
Sahi hai bhai nahi to apne indian tech channels moork banane ka kaam karte hain, par tumhari videos sahi hai bhai.
Aise vedios dete rehna bhai ..... 👍
Bauth mst bhai...ise choti choti but important things Ko bataya karo..
Ye Mumbai emu pe hota he, but iska reason aaj pata chala.
Thank you.... hm waha ki local train ki light off ho jati hogi
Knowledge Knorr but me sochtha tha ki.. AC to DC Ko change karte honge. Isiliye off then on hota hoga karke.
Bhai ji loco ka DJ off krne k sath pento bhi down krna pdta h kya
Sir ye btaiye
Emu me 3-4 penthograph hote hai
To
Kya
Hr ek penthograph down Kiya jata hai.....?
Plz rply
Sir sheshnag train me 9 locomotive hote hai to use neutral section aane par kaise control Kiya jata hai
जबरदस्त वीडियो :)
Conventional neutral mein pentograph uper niche bar bar hota hai kya ? Uski speed kitni hoti hai us time ?
But sir new locomotives mei iski jarurat nahi padti.... Splcly train jab speed mei chal rahi hoti toh sir kya.......
Salute hai boss🤚👍👍
Good video, but if train is multiple unit then how this works as multiple pentograph will be touching overhead wire
Very good information. Keep it up boss.
Hlw sir mera ek sawal h khabhi khabhi rell ki bogi aage hoti h or locomotive phicy to locomotive ko kesy pta hoga h ki aage ka singnal Kiya hoga or kesy chalti h us time p rell
Nice vdo.. app bohut ache somjhaya . AVI symbol ke bare me bataye...ohe symbol Jo app use kiye...
Hamare liye aap bahut achchhee lagi Aapki jankari mere liye bharti karlo plise sir ji
So, interesting knowledge supperb.
Bohot bohot shukriya bhaii
Aur bhi training se related vdo bnane ki kosis kre....
Thanku
Sar agar ohe pa chala jaaye hue Ji se to kya locomotive mein Aag lag sakti
Diesal engine to OHE se connected nahi rehta hai fir coaches m electricity supply kese jaati hai?
जब ट्रेन रात में 1-2 घंटे लगातार तेज स्पीड में चलती रहती है, तब लोको पायलट न्यूट्रल सैक्शन कैसे पार करते है(पेंटोग्राफ कैसे डाउन या इंजन बंद करते हैं)
Uninsullated overlapping of OHE ruclips.net/video/XmFSym51wYM/видео.html
Ekdam umda....... sir ek baat btayein ki ohe dwara electricity lete hai toh maine pdha hai ki circuit complete track se hta hai ... toh fir jab hum track ko hath lgate hai toh hume current kyun nai lgta??
Track me neutral supply hota hai....gud topic.... eske upar video lakar batate h
udit sethi kyun ki railway track ko jagah jagah earth (electrically ground) kiya jaatata hai.... because earth ka resistance humare yani insaan ke resistance se kum hoti hai... is liye electric current low resistance path ko use karti hai
Sub station ke transformer ke secondary part se ek wire OHE wires ke saath connect ki jaati hai.... aur dusre wire ko ground kiya jaata hai dusri ore loco se bijli apna kaam karke earth ko (ground) ko chali jaati hai... is tarah se circuit complete hota hai
abhishek dasgupta toh isse toh losses bht hnge...earth leakage jaise aur bht
udit sethi nahi hote because on the secondary side of the transformer on a railway grid me neutral nikalne ke liye star connection kia jaata hai .... us neutral ko ground kiya jaata hai.... aur phase ko ohe catenaries me diya jaata hai. Jab bijli apna kaam kar ke wheels se hote hue ground hoti hai..... dono grounding terminals ko bahut pass me rakha jaata hai
Sar Mera sawal yah hai High tension lineon mein vibration machine lagai jaati hai per railway railway mein itna vibration hota hai to vibration machine kyon nahin lagai jaati
Thanks very much for this information.
SIR LOCAL TRAIN (MUMBAI) AUR VANDE BHART JAISI TRAINO ME KAE PAINTOGRAF DIYE HOTE H VHA PAR NETRUL SECTION KO KAISE PAR KARTE H 😊😊
Extraordinary containt. Keep it up
ipr-fut section pr bhi video and...light signals of locomotive..headlight ke bgal wali yellow light jo blink krti h wo kisliye hai...and slr ke guard gate ke bagal me upar choti side lamp hoti h...wo kisliye hai...
Mridul Ranjan maira videos bhi dekhna bhai please....🙂
Light signal of locomotive par video milegi jaldi hi...baki k liye wait karna padega
Sir OHE ke pawer ket ho jaye to locomotive kitna dur jaa sakta hai es ke uper 1 video bana wo
Emu trin mein toh 3 or 4 engine hota hein. Matlab 3 or 4 pantograph hota hein. Toh agar 1 pantograph neutral section se par kare toh dusta wala toh phase se jura hota hein. Agar train ka 2 pantograph 2 alag ohase se jura hota hein toh kya woh train pe koi effect karega? Samjha dijiye sir
Uninsullated overlapping of OHE ruclips.net/video/XmFSym51wYM/видео.html
Good explanation sir .
Amitji want to know why guards exchange flag or show it to opposite direction comming or going goods or mail exp. Train.
Sir loco off krte mtlb PANTOGRAPH niche krte he
Neatural section ko cross krte time pe pantograph ko down kr diya jata hai kya????
yes
In latest Loco pilot has to switch off DJ (Dis-Jointer)
The sign shown in this video are for the same
I.e. to indicate Loco pilot that when to switch off and when to switch on the DJ
Taaki wo do live phase ko short n kr de..jisse ki ek unsymmetrical L-L fault aayega jo ki unbalancing ka karan bnega
Only drip the dj panto ko down nhi krte hai..
Very well explained , Thanks
Achhi koshish ki aapne
But is kafi kuch nhi btaya
The most important 'PTFE type neutral section' jo abhi railway me practice me hai
But still I appreciate your efforts,👍👍
Hahaha mere ghar ke pass hi neutral section hai daily base pr yaha se passenger train chalti h soch raha hu jaa ke chain puling kar du fir mAja aayega...
😊😊
Thats the evilest thing i can imagine😂😂😂
फिर बेटा तुझ पर रेलवे की कानूनी कार्यवाही होगी,और जेल के हवा खायेगा
@@princejoe1794 😂😂
Wow.... Itna technical hai.....
Sir wag 5 loco ka DJ control circuit with ARNO and auxiliary control circuit ka video banayena please
Sometimes, we see that the wire which connects the two OHE are in the shape of C or S. Why? What is the use of it, and why it is given?
Electric Engine ka starter AC hai ya DC?...
ur videos are amazing. handz off 2u admin
Aap neutral section k bare me bata rahe hai ya neutral zone k bare me
acha bhai short neutral section toh station ke pass bhi provide karte hein aur uss samay rail ka spped 20/15 kmph sppeed me hota he . can you please explain this concept????
sare neutral section ka record control room k pas rahta hai wah train ko us position h speed slow nHi hone denge.....
Great Info👏👏👏
Nice one and specially informative
You are great bro
Thanks for very important information
1.45me Pantagraph touch Kar Gaya,pilots bhul Gaya kya????
very good but could not understand it as it was the first view for me and the contents were related with electrical engineering not home for me.
A grade B grade station me difference par video bana digiye
Wow this video is best😉😉
Neutral section me jab power nhi rahta hai to phir loco chalta kaise hai , loco Ko to turant hi stop ho Jana chaiye.
Please clarify confusion
Loco ki itni speed hoti h ki wah 5 meter ki section ko par kar jata h
Nagpur ke diamond crossing pe dheka hu me..ki loco ka pentograph neche Kiya jata he....kya EMU pe bi pentograph Ko neeche Kiya jata he ya fir aur kuch Kiya jata he,???
use bhi kiya jata h
Knowledge Knorr actually samja NY me..sorry....mera question ye he ki.."kya 12 coach EMU pe pura 4 pentograph Ko neeche Kiya jata he...ya pilot hi kuch on off kar tha he?"
pilot off kar deta hai
Loco pilot raat me bord ko kaise dekhta hoga.....???
Aap ki aawaj bahut acchi hai
Please make videos on how locomotive completes its circuit i.e how phase and neutral are connected in locomotive and how the make the circuit at such high speed
Ok gud.....jaldi hi banayenge
Sir aap Nagpur Junction pe diamond crossing kaam kaisi karta hai unpe aap video banayege?
Ok jarur bana denge
While changing the pentograph from R phase to Y then sparing occur ??
السلام عليكم ورحمة الله: سرآپ بہت اچھاکام کررھےھیں، آپکی تمام ویڈیوبہت اچھی ھوتی ھیں- میں آپکافین ھوں- سربعض جگہ پرریلوےٹریک کےاوپرسفیدچونےسےبجری اورٹریک کےاوپرچونالگایاجاتاھے، کیوں؟ پلیزآپ اِس مسلہ کےاوپرویڈیوبنائیں؟کےاوپرویڈیوبنائیں شکریہ-
شاھدShahid
لاھورچھانیLahore Cantt
پاکستانPakistan
Sir what is the role of senior section engineer and junior engineer in Indian Railways m video bnao please
Excellent sir .
Sir termination of speed restriction for passenger train and termination of indicator passenger train konesa sir Sahi hai comment Kare ke bataye
Sir Owaisi ka current AC rahata hai ki DC
Nice information bro..
Amit Sir plzz charge sheet ke baare mein bataye plzz
Please make video for the knowledge of multiplexer.
Great
Experience
Sir
Why wcam locos use front pantograph all the time?
Simulator k upar vedeo banaye pls
जबरदस्त bro