Orientation and Configuration of Danfoss VLT FC 051/ FC 360 / FC 101 Drives || Digicon Automation

Поделиться
HTML-код
  • Опубликовано: 25 авг 2024
  • || Three wire start stop with speed POT application ||
    Parameter list for Three wire start stop with speed POT application :
    1-20 = Motor Power [kW] [hp]
    1-22 = Motor Voltage
    1-23 = Motor Frequency
    1-24 = Motor current
    1-25 = Motor Nominal Speed
    3-15 = [ 1 ] Analog Input 53
    3-16 = [ 0 ] No function
    3-41 = Acceleration Time
    3-42 = Deceleration Time
    5-10 = [ 9 ] Latched start
    5-12 = [ 6 ] Stop inverse

Комментарии • 89

  • @vijaysharma-qn6nx
    @vijaysharma-qn6nx 4 года назад +1

    thanks sir..very important knowledge.....SV Electronnics Nanded maharashtra

  • @gurpreetsinghpreet3280
    @gurpreetsinghpreet3280 Год назад

    Very very nice sir.

  • @user-li8ph8wr5p
    @user-li8ph8wr5p 7 месяцев назад

    Very Good working

  • @drprajapati7147
    @drprajapati7147 3 года назад +1

    yes good

  • @rameshpatil8065
    @rameshpatil8065 4 года назад +1

    very helpful video

  • @manjulakarunathilaka7949
    @manjulakarunathilaka7949 9 месяцев назад

    👍👍❤ thanks frind

  • @PraveenKumar-qr8mc
    @PraveenKumar-qr8mc 4 года назад +2

    Hello
    Thanks for the wonderful video. I'm using Danfoss VLT HVAC Basic Drive FC 101 and want to use pushbutton for speed up and down. But I noticed there is no terminal 33. As per the manuals, only model Danfoss VLT micro drive FC 51 and VLT automaton drive have terminal 33. Please advise how to use pushbutton for speed up and down for Danfoss VLT HVAC Basic Drive FC 101.
    Thank You

  • @rajeshmondal2424
    @rajeshmondal2424 4 года назад +1

    So good

  • @jaiprakashgupta3332
    @jaiprakashgupta3332 10 месяцев назад

    i want to know about terminal 20 and 33 setting i am using this terminal for over limit

  • @peternauta
    @peternauta 3 года назад +1

    Which language is this?

  • @engineeraliahmadsabir2382
    @engineeraliahmadsabir2382 3 года назад

    Good

  • @Bharataryans
    @Bharataryans Год назад

    How can we replace it with old drive of commercial trademill ??

  • @drprajapati7147
    @drprajapati7147 3 года назад +1

    We have Danfoss ac Drives FC 51 -micro drives ASD ENGINEERING DELHI-92

  • @sdengineers1742
    @sdengineers1742 3 года назад +1

    AM DL Sharma From Rajasthan Am Use FC 360 Drive .
    Our issue
    We Use Control card In 5.5 hp DRIVE then Run The Drive But Used this Control Card in 1.5 kw 2hp then COME Al 38
    Same Control Card Run in 5.5 hp But 2 hp Not Run come Al 38
    so Plz Tell How to Remove Al 38 In Control Card.

    • @DIGICONAUTOMATION
      @DIGICONAUTOMATION  3 года назад

      Alarm 38 for Internal fault, You need to update the software version of VFD to reset this Alarm

  • @eyadadel1959
    @eyadadel1959 Месяц назад

    Hi Dear
    How to get the registers addresses of the fc101 vfd

  • @harshpanchal3372
    @harshpanchal3372 5 лет назад

    Nice video 👍

  • @lalbabuyadav8023
    @lalbabuyadav8023 Год назад

    Hi good morning

  • @michaelnasief9245
    @michaelnasief9245 Год назад

    Dear i have danfoss FCM 305 - with worming indicated local stop - i tried every thing - can you help

  • @_keshav004
    @_keshav004 Год назад

    Please guide on automation drive.

  • @ppremkumarpremkumar6822
    @ppremkumarpremkumar6822 3 года назад +1

    How to connect digital scaling meter and program in danfoss vfd

  • @samisk2169
    @samisk2169 2 года назад

    Hello my friend, well done for posting

  • @MrMsJomol
    @MrMsJomol 3 года назад

    is there any ready signal form vfd for programing with plc?

  • @gauravsharma-gc4cp
    @gauravsharma-gc4cp Год назад

    Sir humari company mai danfoss vfd ,wo phase loss dikhata hai bar bar ,humne output cables aur motor check ki okay hai,shi chalti h lekin 2 -3 gnte m fault aata hai isko reset kese kre

  • @subdaralam5050
    @subdaralam5050 3 года назад +1

    Sir jaise Ham bahar se start stop push button use karnah aur drive ka potential use karna hai

  • @lalbabuyadav8023
    @lalbabuyadav8023 Год назад

    Ek problem hai
    Please help me
    Danfoss fc360 hai usme ek. Warning 7aa raha hai

  • @ultimatesolution9935
    @ultimatesolution9935 Год назад

    Danfoss me multistage speed ke baare me video banaye.

  • @sharifhossain8830
    @sharifhossain8830 3 года назад

    Direction of rotation parameter which one?
    Forward or Reverse or Both
    Thanks

  • @adrianacastaneda5548
    @adrianacastaneda5548 3 года назад

    Buen día. Será que me podrías apoyar con los parámetros y conexión que debería utilizar para un alternado de dos variadores con transductor? Es decir que encienda uno, se para y encienda el segundo, luego se pare y encienda nuevamente el primero etc
    🙏🏻

  • @PDQknives
    @PDQknives 4 года назад +1

    Thanks you, great video! I need to run a motor up to 70 Hz using an external potentiometer, and i can't do it. 3-15 parameter is in "1" already. The motor gets to 50 Hz. Do you know what could be happenning? Thanks!

    • @DIGICONAUTOMATION
      @DIGICONAUTOMATION  4 года назад

      thank you..
      You need to set three parameters...as per below,
      3-03 = 70 Hz
      4-14 = 70 Hz
      6-15 = 70 Hz

    • @PDQknives
      @PDQknives 4 года назад +2

      @@DIGICONAUTOMATION Thank you very much!

    • @ultimatesolution9935
      @ultimatesolution9935 Год назад

      ​@@DIGICONAUTOMATIONbut sir motor may get hot ,I think

  • @user-sg4kw9di6g
    @user-sg4kw9di6g Год назад

    Brak Ragister ka use kha kiya jata hy 😊

  • @sandeepkaushik1998
    @sandeepkaushik1998 4 года назад +1

    Sir delta drive ke auto/manual ckt ke bare me bi btaoge.sir plz

  • @ganpatmungase8517
    @ganpatmungase8517 4 года назад +1

    Dear sir
    whats difrants in - FC -051, FC360 and FC - 101

    • @boobathirajaduraisamy5155
      @boobathirajaduraisamy5155 4 года назад +1

      FC101 Refrigeration Drive most used in chillers, Air-conditioning,
      FC051 is Small Application used automachine drive,
      FC360 is Fan application and Pumb application Specifically used and number of digital input is high.
      Basic different is Different firmware and parameters used in the drive
      You want any help please Call 8637641293 I will guide you,
      Currently I am working in danfoss drives..

  • @dibyaranjanbehera6366
    @dibyaranjanbehera6366 Год назад

    Frequency kaise badha te hain

  • @shubhambhardwaj2687
    @shubhambhardwaj2687 2 года назад

    Sir. Who is relay trip parameters in vlt micro drive 51

  • @consoultechnical1688
    @consoultechnical1688 3 года назад

    Sir fc51 drive mein samne display mein rpm kaise dekhenge.

  • @suncontrols1884
    @suncontrols1884 4 года назад +1

    hi im velu from sun controls bangalofre . i have one doubt my danfoss vfd showing overcurrent error without conneting motor wht is the issu plesae help me

    • @DIGICONAUTOMATION
      @DIGICONAUTOMATION  4 года назад

      Okay sir, you have to do factory reset your VFD.
      ruclips.net/video/7RAzQeYtttY/видео.html

    • @suncontrols1884
      @suncontrols1884 4 года назад +1

      Thank u for reply...one more doubt if I do factory reset all saved data will be delete or only alarm will delete?

    • @DIGICONAUTOMATION
      @DIGICONAUTOMATION  4 года назад +1

      @@suncontrols1884 All data will be deleted

  • @anirbanghosh1592
    @anirbanghosh1592 4 года назад

    dear sir,
    in circuit diagram u have shown that latched start to terminal no 12,do it means a continuous nc puls should be given at point 12 or one time nc pulse is required

    • @DIGICONAUTOMATION
      @DIGICONAUTOMATION  4 года назад +1

      Terminal 12 is for +24V supply, where for latched start we used a terminal no. 18

    • @ultimatesolution9935
      @ultimatesolution9935 Год назад

      Friend,really terminal 12 is a source of +24vdc

  • @rahuldeo7892
    @rahuldeo7892 4 года назад

    I have 7.5 hp danfoss fc51 and it taking 4 to 20 ma frequency command but after power trip vfd is not taking 4 to 20 ma command and there is any alarm and i have connected 55 and 60 number terminals. Please suggest me how do i check and what is parameters of 4 to 20 ma for plc or pid and 0 to 10 volt for 10k port.

    • @ultimatesolution9935
      @ultimatesolution9935 Год назад

      Dear friend,
      According to me,
      For 4-20ma
      3-15......[2]
      For start command you can select 5-10....[8]
      6-22....4ma
      6-23...20 ma
      Rest keep default settings
      Connection diagram:
      Term. 60 ...... +
      Term.55......... -
      Connection of start command
      Between term.12 and Terminal 18.....NO contact.
      Rest on your feedback

  • @mahmoodbhaijaan4062
    @mahmoodbhaijaan4062 4 года назад +1

    sir muje motor ki frequency badaani hai konsa parameter hai

    • @DIGICONAUTOMATION
      @DIGICONAUTOMATION  4 года назад

      Parameter 3-03 = Max. frequency that you want
      Parameter 4-14 = Max. frequency that you want

  • @mohammedeathesham2151
    @mohammedeathesham2151 3 года назад

    Dear sir,
    You explaination was very simple and good.
    I am facing one similar problem at site can you please help me out.
    When i am starting the motor it's frequency is directly going to 50hz.
    I want to control the frequency from 20hz and as vtg increases frequency should also increase.
    Can you please guide me to do the settings for the frequency.

    • @ultimatesolution9935
      @ultimatesolution9935 Год назад

      अगर आप FC 51 use kar rahe hai to
      Parameter
      4-12........motor speed low limit
      Aur 3-02......minimum reference check check kare
      Inme aap 50hz rakhe hue hai.isko 0 ya kuchh rakhe jisse aap start Karna chahte hai.

  • @ratneshtripathi1095
    @ratneshtripathi1095 2 года назад

    Vlt 5000 ka revars and farvard fara mitar sir

  • @niksontalan5803
    @niksontalan5803 4 года назад

    Hello mr.can you make totorial vidio how seting parameters vfd motor dc for me..?

  • @guddumoriya5258
    @guddumoriya5258 Год назад

    Lock or unlock kaise kiya jaaye

  • @sonajipohne2359
    @sonajipohne2359 3 года назад

    Dear Sir
    Danfoss drive FC 102
    This driver problem is ....
    Short circuit (16A) on display
    How to solve this problem
    Plz help me sir

  • @sanjuaher2181
    @sanjuaher2181 3 года назад +1

    Sanjay Aher

  • @ManojKumar-xm3oi
    @ManojKumar-xm3oi 5 лет назад +1

    Sir Dc Se chalane keley kaya program danlna padega

  • @supanditroy7191
    @supanditroy7191 2 года назад

    Frequency wrong show ho raha

  • @harpreetsingh2696
    @harpreetsingh2696 4 года назад

    ID Run ka kya parameter ha sir

  • @classicwheelsunited
    @classicwheelsunited 3 года назад

    Hi there! I am interested on the Digicon Start/Stop panel. Does it have a part number or can you tell me where to buy it? Best regards, Istvan

  • @varatharajvaratharaj1635
    @varatharajvaratharaj1635 Год назад

    Over load production setting

  • @pramodkumarmandal7940
    @pramodkumarmandal7940 4 года назад +1

    Password laga ho to kai se parameter set kare ge

  • @machagiriprasad2305
    @machagiriprasad2305 3 года назад

    Wiring vfd to motor

  • @radhikavermaofficial1811
    @radhikavermaofficial1811 4 года назад +1

    Vlt 2800 parameter setting

  • @sharandeep6819
    @sharandeep6819 3 года назад

    S,haran

  • @asifsaifi6122
    @asifsaifi6122 3 года назад

    Kisi Koo old VFD chaiye too muje reply karke mujse baat kar skte hoo

  • @aaronelieservalenzuelamart2734
    @aaronelieservalenzuelamart2734 4 года назад

    En español por fa

  • @syedtayyab2411
    @syedtayyab2411 4 года назад

    Sir aap ka no milega kya

  • @chaudharykaif
    @chaudharykaif 3 года назад +1

    Port ka parameters tobbataye hi nahi

    • @DIGICONAUTOMATION
      @DIGICONAUTOMATION  3 года назад

      For POT, If u connect the wire on terminal 53 then set [1] on parameter 3-15..

    • @chaudharykaif
      @chaudharykaif 3 года назад

      @@DIGICONAUTOMATION thanks sir

    • @chaudharykaif
      @chaudharykaif 3 года назад +1

      @@DIGICONAUTOMATION vfd037M43A display pe hpf dhikha raha hai to kaya problem hai

    • @DIGICONAUTOMATION
      @DIGICONAUTOMATION  3 года назад

      @@chaudharykaif Can u share a picture ?

    • @chaudharykaif
      @chaudharykaif 3 года назад

      Picture kis pe share karo