- Видео 41
- Просмотров 675 561
DIGICON AUTOMATION
Индия
Добавлен 22 май 2019
Digicon is a 21 years young , ever growing , customer centric , Solution Provider in field of Industrial Automation / Control Automation. We are a self sufficient Organization , capable of taking care of Pre & Post Sale Technical as well as Service Needs of our Customers ; backed up by a team of enthusiastic Engineers. Digicon is having a manufacturing set up at Ahmedabad and Sale - Service Office at Mumbai.
HO / Regd Off :
Plot No 179, Road No 4, Gidc, Kathwada,
Off S P Ring Road, Nr Gvmm - Odhav,
Ahmedabad - 382430 ( India ).
Phone : 079 29702955 / 9998402238
Email : sales@digicon.in
BO (MUMBAI):
104 , Sambhav Industrial Estate, Navghar, Vasai Road ( E ),
Mumbai - 401210 (India).
Phone : 9130051949 / 9322263157
Email : mumbai@digicon.in
HO / Regd Off :
Plot No 179, Road No 4, Gidc, Kathwada,
Off S P Ring Road, Nr Gvmm - Odhav,
Ahmedabad - 382430 ( India ).
Phone : 079 29702955 / 9998402238
Email : sales@digicon.in
BO (MUMBAI):
104 , Sambhav Industrial Estate, Navghar, Vasai Road ( E ),
Mumbai - 401210 (India).
Phone : 9130051949 / 9322263157
Email : mumbai@digicon.in
Installed and Configured 500kW VFD ROHPP PLC Electric Control panel for RO Water Plant System
We have successfully installed and configured 500KW VFD RO-HPP PLC Control panel for RO water plant system for one of our customer in Gujarat.
This Panel includes VFD, PLC, Soft-starter and HMI for this system.
This Panel includes VFD, PLC, Soft-starter and HMI for this system.
Просмотров: 693
Видео
How to Troubleshoot and Diagnose the Fault 2-Over voltage & 9-Under voltage in Vacon VFD ? | DIGICON
Просмотров 1,7 тыс.3 года назад
How to Troubleshoot and Diagnose the, Fault 2 - Over voltage Fault 9 - Under voltage In Vacon VFD's...
Integration of Vacon 20 with Temperature sensor using PID control || DIGICON AUTOMATION || DANFOSS
Просмотров 2,4 тыс.3 года назад
Integration of Vacon 20 with Temperature sensor using PID control, also you can see the power wiring, control wiring and parameters configuration in this video.
How to troubleshoot and diagnose the WARNING/ALARM 25, 27 and 28 ? _BRAKING RESISTORS || DIGICON
Просмотров 5213 года назад
ALARM 25, Brake Resistor Short Circuit ALARM 27, Brake IGBT / Brake Chopper Short Circuited / Brake Chopper Fault ALARM 28, Brake Check
How to troubleshoot and diagnose the WARNING/ALARM 10 and 11 || DIGICON AUTOMATION || Danfoss
Просмотров 3,9 тыс.3 года назад
Warning / Alarm 10, Motor Overload Temperature : According to the electronic thermal protection (ETR), the motor is too hot. The fault occurs when the motor is overloaded by more than 100% for too long. Warning / Alarm 11, Motor Thermistor over temperature : Check whether the thermistor is disconnected. Select whether the frequency converter issues a warning or an alarm in parameter 1-90 Motor ...
How to troubleshoot and diagnose the Errors in Danfoss VFD ? || DIGICON AUTOMATION || DANFOSS
Просмотров 2,7 тыс.3 года назад
In this video we troubleshoot and diagnose the following Errors, Error 85, 86, 88, 89, 92, 93 and 95
How to troubleshoot and diagnose the WARNING/ALARM 12, Torque Limit? || DIGICON AUTOMATION | DANFOSS
Просмотров 13 тыс.3 года назад
Torque Limit is a drive function that puts limits on the torque the motor can deliver. The torque has exceeded the value in parameter 4-16 Torque Limit Motor Mode or the value in parameter 4-17 Torque Limit Generator Mode.
Commissioning of control panel for Plough/Batch Mixing system by us for one of our Customer
Просмотров 3313 года назад
We have successfully installed and configured MCC Electric Control panel with PLC and VFD for Plough/Batch Mixing system at one of our customer’s plant in West Bengal.
DIGICON offers on site repair/Maintenance Contracts for Danfoss/Vacon VFD’s || A.M.C. || DIGICON
Просмотров 3204 года назад
Digicon offers on site repair / Maintenance Contracts for Danfoss / Vacon VFD’s ; Backed by a team qualified, well trained, Experienced Engineers. THESE SERVICES ARE OFFERED BY HOUSE OF DIGICON , HAVING MORE THAN 20 YEARS HANDS-ON EXPERINCE OF SELLING & RENDERING AFTER SALE SUPPORT FOR ALL RATINGS OF DANFOSS DRIVES.
Troubleshoot, If the drive is not responding to speed/reference command. || DIGICON || DANFOSS
Просмотров 6184 года назад
Troubleshoot, If the drive is not responding to speed/reference command.
How to troubleshoot and diagnose the WARNING/ALARM 47, 24 V Supply low? || DIGICON AUTOMATION
Просмотров 4,3 тыс.4 года назад
The supply on the power card or control card is out of range. There are 3 supplies generated by the switch mode supply (SMPS) on the power card: • 24 V • 5 V • ±18 V
How to troubleshoot this, If motor is not reaching maximum speed? || DIGICON AUTOMATION || DANFOSS
Просмотров 2564 года назад
In this video we will show you that, How to troubleshoot if Motor is not reaching maximum speed in Danfoss VLT series VFD's. Also, we will show you about the possible causes, test, and solutions..
How to troubleshoot and diagnose, If Motor is running in the wrong direction || DIGICON || DANFOSS
Просмотров 1604 года назад
In this video we discussed about, what we have to do if motor running in the wrong direction.
How to troubleshoot and diagnose the Alarm 14 Earth (Ground) Fault & Alarm 16 Short Circuit?
Просмотров 12 тыс.4 года назад
Alarm 14, Earth (ground) fault There is current from the output phase to ground, either in the cable between the drive system and the motor, or in the motor itself. Alarm 16, Short circuit There is a short circuit in the motor or motor wiring.
How to troubleshoot and diagnose the Alarm 29 and Alarm 244 Heat-sink temperature? || DIGICON
Просмотров 3,5 тыс.4 года назад
The maximum temperature of the heat sink is exceeded. The temperature fault is not reset until the temperature drops below a defined heat sink temperature. The trip and reset points are different based on the frequency converter power size. Alarm 244 is only for enclosure type F frequency converters. It is equivalent to Alarm 29
PRESSURE BOOSTER CONTROL SYSTEM IN CASE OF MULTIPLE PUMPS USING VACON-20 VFD || DIGICON AUTOMATION
Просмотров 1,4 тыс.4 года назад
PRESSURE BOOSTER CONTROL SYSTEM IN CASE OF MULTIPLE PUMPS USING VACON-20 VFD || DIGICON AUTOMATION
"VFDnet - Digicon Offers Simple, Yet Cost Effective Solution to add IIOT features to VFD" || DIGICON
Просмотров 3434 года назад
"VFDnet - Digicon Offers Simple, Yet Cost Effective Solution to add IIOT features to VFD" || DIGICON
DIGICON offers control panel for Independent AHU control with BMS Connectivity || DIGICON AUTOMATION
Просмотров 3324 года назад
DIGICON offers control panel for Independent AHU control with BMS Connectivity || DIGICON AUTOMATION
How to troubleshoot this, If your motor is not running by VFD? || DIGICON AUTOMATION || DANFOSS
Просмотров 1,2 тыс.4 года назад
How to troubleshoot this, If your motor is not running by VFD? || DIGICON AUTOMATION || DANFOSS
How to Troubleshoot and Diagnose the ALARM/WARNING 13 in Danfoss VFDs? | DIGICONAUTOMATION | DANFOSS
Просмотров 12 тыс.4 года назад
How to Troubleshoot and Diagnose the ALARM/WARNING 13 in Danfoss VFDs? | DIGICONAUTOMATION | DANFOSS
CUT TO LENGTH MACHINE USING DANFOSS VARIABLE FREQUENCY DRIVE (VFD) AND MOTION CONTROL OPTION (MCO)
Просмотров 1,4 тыс.4 года назад
CUT TO LENGTH MACHINE USING DANFOSS VARIABLE FREQUENCY DRIVE (VFD) AND MOTION CONTROL OPTION (MCO)
How to Run Danfoss VLT Drives with Modbus Communication via ModScan Software || DIGICON AUTOMATION
Просмотров 15 тыс.4 года назад
How to Run Danfoss VLT Drives with Modbus Communication via ModScan Software || DIGICON AUTOMATION
Configuring Danfoss VLT HVAC Basic FC-101 for Air handling unit (AHU) and FAN Application || digicon
Просмотров 39 тыс.4 года назад
Configuring Danfoss VLT HVAC Basic FC-101 for Air handling unit (AHU) and FAN Application || digicon
How do I configure JOG speed operation on Danfoss VFD's ? || DIGICON AUTOMATION || DANFOSS
Просмотров 6 тыс.4 года назад
How do I configure JOG speed operation on Danfoss VFD's ? || DIGICON AUTOMATION || DANFOSS
Extracting & loading parameters into Danfoss VLT FC-051 using MCT10 software || DIGICON AUTOMATION
Просмотров 9594 года назад
Extracting & loading parameters into Danfoss VLT FC-051 using MCT10 software || DIGICON AUTOMATION
How to Troubleshoot and Diagnose the ALARM/WARNING 8 in Danfoss VFD's? | DIGICONAUTOMATION | DANFOSS
Просмотров 8 тыс.4 года назад
How to Troubleshoot and Diagnose the ALARM/WARNING 8 in Danfoss VFD's? | DIGICONAUTOMATION | DANFOSS
How to Install and Replace the VFD Cooling Fan into Danfoss VLT AutomationDrive FC 360 (4 kW/5.5 HP)
Просмотров 12 тыс.4 года назад
How to Install and Replace the VFD Cooling Fan into Danfoss VLT AutomationDrive FC 360 (4 kW/5.5 HP)
How to Troubleshoot and Diagnose the Error 84 in Danfoss VFD's? || DIGICON AUTOMATION || DANFOSS
Просмотров 14 тыс.4 года назад
How to Troubleshoot and Diagnose the Error 84 in Danfoss VFD's? || DIGICON AUTOMATION || DANFOSS
Communication setup between Danfoss VLT HVAC BASIC FC-101 & Phoenix Contact PLC || DigiconAutomation
Просмотров 8 тыс.4 года назад
Communication setup between Danfoss VLT HVAC BASIC FC-101 & Phoenix Contact PLC || DigiconAutomation
How to achieve Modbus communication between Danfoss VLT HVAC BASIC FC101 & Danfoss MCX06D Controller
Просмотров 16 тыс.4 года назад
How to achieve Modbus communication between Danfoss VLT HVAC BASIC FC101 & Danfoss MCX06D Controller
Clark William Hernandez Shirley Martin Nancy
Sir. Please selection Krna sikhaye
Please give me contact number
Sir apka video dekhke drive chalu kiya to huwa nahi
Sir in fc 302 model...not coming option of parameter 0. 50 ...what can we do
Hi Dear How to get the registers addresses of the fc101 vfd
Sir motor speed badana hae kaes badae
Super
Sir, our vfd first showed overcurrent fault, but now the frequency, current and voltage are shown to be fluctuating up and down repeatedly back and forth. This is for RO High pressure pump system
Very Good working
Ghalti se auto on ka button press hoo gaya ab woh start nahi hoo rha
S/N950202A252 Setig
❤❤❤❤good video🎥🎥
Currently troubleshooting a DanFoss VFD using Etherent/IP. When we send an output from the PLC it receives the command to start but does not receive the reference speed that we are sending it. Not sure why its not interpreting the reference value. Tried following your steps and param 3-15 is set to Analog Input 53. What are you referring to by positive wire and negative wire?
Now 10v singnal from?
can you provide the location of where the backup 24v connect to, it looks for it so obviously it will fix it
Sir danfoss 360 ko synchronisation kaise kre or external source kliye parameters kya h
Volume too low
Thanks thanks and thanks a lot for this video. Problem resolved.
👍👍❤ thanks frind
me aparece el err 84 me apoyas yo lo tradusco a español gracias
Good
i want to know about terminal 20 and 33 setting i am using this terminal for over limit
coloco os mesmos parametros e o inversor não funciona o speed up e speed down, o que pode ser?
Please guide on automation drive.
Motor thermistor kaise connect karenge isme
Sir Danfoss 51 model me agar password laga ho to password kai hata be.
Danfoss me multistage speed ke baare me video banaye.
Hello is the Modbus address is same for all models of Danfoss vfd? Also please share your contact details, I have some douts it will be helpfull
Dear sir frequency ko modulate karne ke liye vfd me referance source 3-15 ko kis per rakhna padega
How to change prameter in danfoss VLT a.c.microw drive if password set by unknown peroson.
Very useful video sir 🎉😊😊 please make a video on danfoss 301 drive
Dear i have danfoss FCM 305 - with worming indicated local stop - i tried every thing - can you help
Dear i have danfoss FCM 305 - with worming indicated local stop - i tried every thing - can you help
Dear i have danfoss FCM 305 - with worming indicated local stop - i tried every thing - can you help
DBR VALUES FOR FC360 SERIES VFD?
Hola, que porcentaje del tiempo se aceleración o desaceleración se tiene que aumentar? y cual es el limite?
where terminal 33 defined in program?
Should we turn of the drive first?
Lock or unlock kaise kiya jaaye
How can we replace it with old drive of commercial trademill ??
Sir humari company mai danfoss vfd ,wo phase loss dikhata hai bar bar ,humne output cables aur motor check ki okay hai,shi chalti h lekin 2 -3 gnte m fault aata hai isko reset kese kre
Sir parametr disturbe ho gya hai ahu start nhi ho rha
We have this product in religious place...it have some tactical issues...how we can repair...can u help us
On command selector switch. Drive running ok. In case power failure. Again power come. Vfd running. I want power come time. Vfd selector switch reset/on. Parameter tell me sir
How to reset AL13 over current alarm
2 wire vfd start command given sir. With selector switch.. But inase power failure. Again come. Selector switch on Position automatically on. But i want power come vfd selector switch rest on/off. Perameter number tell me sir.
Sir fc 51. Vfd.2 wire selector switch on command given. Running ok. In case power failure. Again come power. Vfd on directly. When ever power come selector switch reset on. Pls perameter number tell me sir
Hi can u help me to Wire this. Once the RTD senses Hig Temp. The Danfoss Controller Increase the Frequency Signal Output to Motor.