How to find a refrigerant leak in an air conditioner?

Поделиться
HTML-код
  • Опубликовано: 14 сен 2022
  • Join this channel to get access to perks:
    / @taddydigest
    Wanna Learn more about hvac? Check out my hvac tips for technicians playlist.
    • HVAC Tips for Technicians
    Diversitech 800-002 Pro-2000 Leak Detector Spray - 1 Quart
    amzn.to/3SI2SjI
    Fieldpiece DR58 - Heated Diode Refrigerant Leak Detector
    amzn.to/3y1KvP0
    ‪@DiversiTechCorp‬

Комментарии • 281

  • @dalemihocik4732
    @dalemihocik4732 Год назад +31

    I like how you gave the customer options and didn't judge him on what he chose. I need to find an independent contractor because these company guys are driven to force service contracts and high end equipment down your throat at every given opportunity. Maybe I'll get lucky and find a guy like you.

    • @TaddyDigest
      @TaddyDigest  Год назад +8

      Thank you yeah I just want my customer to be happy. I offer my advice and it's always just what I would do if I had their situation.
      I agree with you A lot of companies are just driven to make a sale and they don't care about the customer

    • @ronniehvac653
      @ronniehvac653 Год назад +3

      Hey Dale, I hear ya brother. I work for a company in the Hudson valley in NY. A lot of competition but countless number of times I'm servicing equipment with the competition's sticker on it. I always try to be as transparent as possible. I've learned that once you lose a customers trust, you've lost their business.

    • @Minimarshi
      @Minimarshi Год назад +2

      @@TaddyDigest I have the same issue, lost about a pound in a year. Have had 3 companies come out only to not pinpoint the leak, guessing it's probably on the back of the evaporator coil like this one. What did you recommend replacing, the coil or the whole handler?

  • @ParabellumX
    @ParabellumX Год назад +21

    I use Fieldpiece's DR82 Infrared Leak Detector. It's freakin awesome!
    I do a 3-hits-it's-a-leak check, but I really don't have to; if it goes off, there's a leak (or I accidentally bumped the tip on something).
    Probably the greatest feature about this particular leak detector is the fact that it gives you three signs to let you know that there is a leak: there's the audible sound, the flashing of the tip, and a vibration throughout the leak detector itself.
    That's awesome!
    So it doesn't matter if you're blind, deaf, or dumb, you will find a leak if there is one!

  • @OcRefrig
    @OcRefrig Год назад +29

    Good video ! But Here’s some tips from a Guy doing it for 42 Years.
    1) if System has at least 1lb of liquid refrigerant in it. ( 410a systems ) Just pull the disconnect. Wait 5 min for system to equalize. Equalized pressures on 410a system at 60 degrees outside with liquid in it will be 170Psig. Higher if its hotter out. See pt chart. 170 is plenty to find a leak with a H10-leak detector or any decent leak detector.
    2) Most Leaks are in evaps. 75% of the time. Start there first.
    3) Rarely have i needed to pressure test over 150 psi to find a Leak with a Ge H10 leak detector.

    • @stevenross9271
      @stevenross9271 Год назад +1

      I have been doing refrigeration and air conditioning for over 45 years. I am partial to my Inficon select. I spent 30 of those years behind a desk as a service manager. I diagnosed techs problems over the phone. Always look for a leak if the unit is low. To just add gas is not performing your job.

    • @stevenross9271
      @stevenross9271 Год назад +1

      The G.E. H-10 with a cord is without a doubt the best leak detector you can get your hands on.

    • @eethridge4065
      @eethridge4065 19 дней назад

      That rare time is that dang ice machine that passes the pressure test twice and has a fan switch that doesn't leak until it hits 275 psi high side....ugh

  • @dioramaworldcustoms
    @dioramaworldcustoms 10 месяцев назад +10

    You are the best teacher on here! I’ve been thinking about going to school for my H-Vac license. Texas is so hot during the summers! I liked & subscribed!

  • @shk2564
    @shk2564 Год назад +13

    “Three dead mice…three dead mice…see how they spin around the blower motor.” 🎶 😂

  • @terrimcglothin2230
    @terrimcglothin2230 Месяц назад +15

    If I can't find a residential leak with an electronic & sonic leak detector within 30-40 minutes , I like to add fluorescent dye while I add refrigerant. This provides comfort cooling until we can reschedule the leak inspection, and let the dye have time to show up After 35 yrs in residential, if I can't find the leak in a half hour or so on most units, then I know it is going to be a tricky one. The uv dye really helps to pinpoint the problem. Owner operators.. Remember, dye is a tool to help you. You dont need to make a fortune on the dye. Be fair to your customers. You will earn a fair profit during the repair or replacement of the coil.

    • @TaddyDigest
      @TaddyDigest  Месяц назад +1

      Excellent advice 👍

    • @GApawpawandnana
      @GApawpawandnana Месяц назад +3

      I wish I could get y’all’s service in NW Georgia. I was told you can’t fix a leak. You have to have a new unit. I get refrigerant added twice a season or use window units.

    • @carolync9408
      @carolync9408 13 дней назад

      I was told leaks could t be fixed period! Dye was added no leak found I was told it must be the unit leaking and that can’t be fixed. The Heil United is 2 years old.

  • @chadriddle3517
    @chadriddle3517 11 месяцев назад +1

    Excellent information in this video! Man I appreciate that for people like me that watches RUclips to learn for homeowner use . Subscribed

    • @TaddyDigest
      @TaddyDigest  11 месяцев назад

      Glad to hear the information was helpful thank you so much for watching

  • @jefflemberg645
    @jefflemberg645 Год назад +45

    How many clowns just fill up your freon and try to sell you a new unit when it all leaks out again?

    • @HippieMosquitoQuatro
      @HippieMosquitoQuatro 5 месяцев назад +3

      Yes.

    • @waynegent2263
      @waynegent2263 5 месяцев назад +8

      My boss gets upset at my sales bc their so low. I always find the leak and make sure customers get repairs pricing and unit price depending on warranty. He hates it but keeps up withit

    • @leestebbins5051
      @leestebbins5051 Месяц назад +2

      Freon? Old timer.

    • @AfiOyeTheNurse
      @AfiOyeTheNurse Месяц назад +2

      Yeeeees! That's why I'm watching this video because we got new unit last year, and the man done put freon in it twice and it's still messed up. He didn't even tell us we had a leak.

    • @southside6924
      @southside6924 29 дней назад +2

      @@AfiOyeTheNurseoh lord that’s not good at all

  • @seadogharris2102
    @seadogharris2102 Год назад +3

    Great information. Just ordered Webb Coil Cleaner from Lowes.

  • @kylehennen
    @kylehennen Год назад +10

    My man’s got a bow tie on his lip!

  • @srobeck77
    @srobeck77 Год назад +20

    The common census for leak checking is to raise the pressure no higher than the highest rating on the low side. Its to avoid damaging the internals of the system.

    • @rwood1995
      @rwood1995 10 месяцев назад +1

      That makes it hard to sell them those items though dont it?? 🤑 JK LOL

    • @g-lato9791
      @g-lato9791 2 месяца назад +1

      Does that also apply to the heat pump tho , since it is reversible and they both use the high pressure

    • @srobeck77
      @srobeck77 2 месяца назад +1

      @@g-lato9791 incorrect. This is a lack of understanding right here. In a heat pump, the high side just alternates between the evaporator and condenser but is still same high side pressure reading to go off and you should not exceed that number.

  • @martinheatingcoolingmartin4693
    @martinheatingcoolingmartin4693 25 дней назад +3

    Excellent work! Thanks for a better understanding on the process. I love learning more and more about my trade.

    • @carolync9408
      @carolync9408 13 дней назад

      And that makes for a great contractor, love to hear that. Some ppl are quick to just make money vs actual saving customers a few dollars.

    • @carolync9408
      @carolync9408 13 дней назад

      I have a question does refrigerant have to be in the unit to use the nitrogen?

    • @carolync9408
      @carolync9408 13 дней назад

      Watching this video tells me why most are saying get a new unit. SMH! Gratitude to you sir for loving and perfect your skills. So appreciated.

  • @garygullikson6349
    @garygullikson6349 11 дней назад +1

    AC guy found our 2008 out of warranty system was out of old type refrigerant. Checked outside unit, no leaks. Plans to check for leaks on inside unit, weld leak if doable, install "stop leak", and new type refrigerant. If systems loses refrigerant, he will deduct charges from total price for new inside unit (or replacement coil) . I was told that old type refrigerant is very expensive, new type is about 95% effective in cooling.

  • @RollingThunder808
    @RollingThunder808 10 месяцев назад +2

    CPS leak detector is the best. We had a leak on the R114 plant and it was like chasing a ghost. We put soap on the area and it took about five minutes and the bubbles were so small it looked like shaving cream. That's how small the leak was.

  • @benb3928
    @benb3928 9 месяцев назад +1

    "I will keep you cool if you let me!" ..clever tag line earned my sub.

  • @godfreyappliance5585
    @godfreyappliance5585 10 месяцев назад +1

    I use accu trak ultrasonic. I have used it for a little over 10 years. Works great. It is not a sniffer. Sniffer will go off with anything that burns.

  • @robsimmons7650
    @robsimmons7650 Месяц назад +2

    H10Pro by Bacharach for leak detectors. Always check the service port caps with electronic before getting the gauges out of the truck and before touching the caps.

  • @dyershvac5884
    @dyershvac5884 Год назад +2

    Great job Tadd!

  • @caru3257
    @caru3257 2 месяца назад +3

    Three dead mice would be a great name for rock band.

  • @maryschultz645
    @maryschultz645 2 месяца назад +1

    thanks for the vid Tad !

  • @RocisBigBroSavage
    @RocisBigBroSavage Год назад +1

    Great quality content. Keep it coming!

  • @thomasglessner6067
    @thomasglessner6067 6 месяцев назад +1

    Great video. Thank for sharing your knowledge and skills. Im subscribed.

  • @calabamian
    @calabamian 10 месяцев назад +1

    Is there anyone cool and honest like you in San Diego?

  • @NytefogNJ
    @NytefogNJ Год назад +3

    I use the Testo 316-4 for R410a systems and the Testo 316-3 for R22, but the Inficon Tek
    Mate is also great option for r-22 systems ( I also have a Inficon tek mate). The Testo 316-4 is probably the most sensitive electronic leak detector I’ve used for r410a.. and I’ve can’t even start to tell you how many electronic leak detectors bought then sold trying to find a good model. Do a Search for NathanHVAC electronic leak detector sensitivity test. He has tested most of the leak detectors I’ve purchased. He has made spreadsheet of the leak detectors and their sensitivity for R22 and R410a refrigerants. I’m trying out Ultrasonic refrigerant leak detector this spring/summer to see if that can help pin point small leak’s faster.

    • @MrDeviousdom
      @MrDeviousdom Год назад +1

      I've used several ultrasonic leak detectors and found that they were useless when trying to find small leaks. See what the return policy is on the tool just in case. A good way to test it is by using a calibration vial.

  • @peterman8058
    @peterman8058 13 дней назад +1

    Nice work!

  • @joshuaseaton7002
    @joshuaseaton7002 Год назад +1

    Hey Tad. What's the 1 to 98 countdown when the wind free units shut off after cooling?

  • @ricardoa4322
    @ricardoa4322 10 месяцев назад +1

    I use the yellow jacket infrared leak detector works great

  • @ronniehvac653
    @ronniehvac653 Год назад +1

    Hey, Tad. I use the yellow jacket sniffer. But I also use the Superior Accu Track ultrasonic leak detector. You could have heard those mice fart before they died.

  • @renaissanceman5847
    @renaissanceman5847 Год назад +3

    I feel for the home owner... but the best thing to do is have some window units ready... 3 units are more than enough to keep you comfortable enough when SHTF with the main AC. they cost $150 each. Then with an older system, especially one approaching 20 years... just get the full install. else with and older system you may find yourself spending more money over the long term vs a new system plus the inconvenience (they always break on a Friday afternoon ) constantly fixing issues as its dies. At least you can get a warranty on installation and equipment that will cover you for a year or more. I also recommend insisting they inject UV dye into the system upon installation or even service. that way its easier to find the leak should one creep up at any point due to installation errors or aging.

  • @thecurious6721
    @thecurious6721 Год назад +2

    Thanks for the tip 👍

  • @sonnguyen-ve7gn
    @sonnguyen-ve7gn 8 месяцев назад +1

    Great video !

  • @TheStantony
    @TheStantony 7 месяцев назад +2

    Hi.
    What are the resons if frequently happen leakage in condenser coil bends

  • @buddybeachboy
    @buddybeachboy 19 дней назад +1

    Great video .

  • @hectordaniel30
    @hectordaniel30 Месяц назад +1

    I joined. Like your videos very thorough .

    • @TaddyDigest
      @TaddyDigest  Месяц назад

      Thank you so much for joining. Here is my email tadfuller1@gmail.com

  • @michaelfesta9289
    @michaelfesta9289 Месяц назад +1

    Great video very Informative And very easy for Me the weekend warrior to follow

  • @williambirt914
    @williambirt914 2 дня назад

    nice job tad, what do youcharge for a leak survey?
    also if a mouse works its way into the main blower squirrel cage it will sound like thunder in your duct work. simply remove and clear sailing.

  • @kabsatofficial
    @kabsatofficial 7 месяцев назад +1

    Thank you ted

  • @alderoth01
    @alderoth01 10 месяцев назад +1

    What does it mean when the copper tubing, the one inside by the unit is warm to the touch, even the copper outside?

  • @stansummers6259
    @stansummers6259 Год назад +1

    Great video buddy

  • @ericwilliams3407
    @ericwilliams3407 7 месяцев назад +1

    Taddy digest have you ever worked on farm equipment ac units I’m a mechanic an have been fighting with one of are equipments ac units I’ve done replaced an fixed where the leak was but it still is leaking down can you help us out

  • @thejimmyrig
    @thejimmyrig Год назад +4

    I have a system from the mid 90s that hasnt run in a few years due to a leak and the refrigerant being super expensive. can a system like that be repaired and retrofitted? or would it be a wash in cost and better to just update?

  • @thecreaturesdancedlikeus3922
    @thecreaturesdancedlikeus3922 28 дней назад +1

    Another great, helpful video! Very nice 👍🏽, very mice 🐁

  • @SteveM-426
    @SteveM-426 11 месяцев назад +1

    Dye is Best! Hands Down.

  • @StevenSchoolAlchemy
    @StevenSchoolAlchemy 10 месяцев назад +1

    tell us about the stop leak additives.

  • @danceaway2nite
    @danceaway2nite Год назад +1

    Bow tie.... mustache?!!! 😂 too cute!!! 😊😊

  • @dgair5635
    @dgair5635 10 месяцев назад +1

    I am just doing some research to learn more. My techs are taking 4 hours to do a leak check after putting dye in the week before :)

  • @southside6924
    @southside6924 29 дней назад +1

    I being hearing good things about the inferred leak detector

  • @joelbell9082
    @joelbell9082 Год назад +4

    If it's a large leak in an air conditioning system it's usually on the high side of the system To check the condenser hook up your high side and low tide gauges turn off the power remove the condenser fan motor from the top of the unit Turn the unit power back on checking the high side pressure with condenser fan motor not working the high side pressure will increase to a point where you might be able to locate the week much easier Do not exceed momentarily 400 PSI Turn off the power check With an electronic leak detector You can also use an UltraViolet leak detector After injecting and allowing the fluid to circulate throughout the system One other method is using nitrogen to build up the pressure to see if we could find a slow leak using a Ultra Violet leak detector after injected fluid All these methods MUST only be performed by specially trained air conditioning service technicians with years of experience Absolutely no homeowners should ever attempt these leak detection procedures which could cause permanent bodily injury or possible death Leave it to the professionals

  • @AfiOyeTheNurse
    @AfiOyeTheNurse Месяц назад +1

    Great video! I feel like people are scheming us and we live in Florida and our AC unit broke 3 times in the last year and we got it new last year. Weird

    • @TaddyDigest
      @TaddyDigest  Месяц назад +1

      It's hard to find Honest companies.

  • @craigmarshall40
    @craigmarshall40 Год назад +2

    You have some good prices 😮

  • @9to5techs
    @9to5techs 4 месяца назад +2

    is goodman heat pump GSZB404210A good for 2014 mobile home? in amarillo texas , r19 walls, r25 roof, r 30 floor, singal pan widows, 1216 sqft home. not air tight it has leaks. temps below 20 is like 8 days during heating seanson. i set termostat to 74 f and am using electric furnace 10 kwh for 108 hours a month. my electric rate is 0.097 kwh. the highest bill to have was 250 but that is from whole home usage. the goodman heat pump says it uses 2.9 kwh at 10 f with a COP of 2.08 and a 2.7 kwh with COP of 1.34 at -5 f. the price for the 5 ton a-coil and 3.5 heat pump is $4,876. i can get 30% off that price on rebate then it whould be $3,413.235 also, why whould tech go with mortex 5 ton a-coil and 3.5 heat pump. thanks for help.

  • @twolfe4295
    @twolfe4295 Год назад +6

    I use the same detector that you have and maybe it would have found the leak if you had used it.

  • @microgreensgrower3946
    @microgreensgrower3946 8 месяцев назад +2

    I'm at 2:20 in the video. Does this hold true for vehicle A/C's? (slow leaks = low pressure side and fast leaks =high pressure side? Thanks for the video!

    • @TaddyDigest
      @TaddyDigest  8 месяцев назад

      It really depends on the size of the area that's leaking

  • @KTK_Rockstar
    @KTK_Rockstar 11 месяцев назад +1

    At what point do you recommend replacing the condenser and evap coil vs just the evap?

  • @StevenSchoolAlchemy
    @StevenSchoolAlchemy 10 месяцев назад +2

    look for oil on the tubing

  • @johnharrisonschulz
    @johnharrisonschulz Месяц назад +1

    500 PSI! The most I ever use is 300 psi for R410A and 150 psi for R22.

  • @kabsatofficial
    @kabsatofficial 7 месяцев назад +4

    500psiig...bro it will not break the system?

  • @flint7777
    @flint7777 Год назад +1

    Good guy

  • @chada472
    @chada472 Год назад +1

    If its a heat pump you have high pressure on the indoor coil when its heating right?

  • @zairuscanales
    @zairuscanales Год назад +1

    Hi! Thank you for this very informative video. I’m your new subscriber. Can I ask you a question regarding our AC unit? We just bought a house and unfortunately the AC is not cooling the room. The AC Unit is manufactured in 2006 (very old). And it’s definitely leaking refrigerant. The technician that checked the unit suggested to add refrigerant and check for leaks 1 or 2 weeks after. Is that okay? Or should I insist to find the leak first?
    I would really appreciate your advise. Thank you on everything that you do!

    • @TaddyDigest
      @TaddyDigest  Год назад

      I would go ahead and let him add refrigerant because you need to know exactly how low it is
      Sometimes, it's hard to find the leak unless the refrigerant is significantly low, so it's good to know how low the refrigerant is before you schedule a leak check

    • @victork3397
      @victork3397 Год назад

      My company likes to use fluorescent trace dye for leak searches. And those require a return visit for Leah search after the dye has been circulating for a few weeks. Maybe that’s what the tech was referring to?

  • @mustangmike6421
    @mustangmike6421 5 месяцев назад +1

    Can u do a video on superheat and subcooling, i know everyone tells people to only check subcooling, which if the system is installed properly the txv will hold the superheat to what it is suppose to be, but alot of the time it's not and superheat is usually way low.

    • @TaddyDigest
      @TaddyDigest  5 месяцев назад

      Type in the search bar super heat and sub cooling taddy digest. I did a video

  • @williamlangley2044
    @williamlangley2044 Год назад +3

    I use dish soap water paint brushes and spray bottle, the leak detector gives me a general idea of the leak is.

    • @SovereignTroll
      @SovereignTroll Год назад

      I was told dish liquids (Dawn, Joy, etc) have lye in them and are corrosive to copper. Use an approved something if you don't want to pay for Big Blue etc..
      Also chlorine sterilizer in condensate drains can attack furnace parts, use vinegar. Yet in reach-ins salad dressings and tomato products seem to eat coils. Who is right?

  • @KTK_Rockstar
    @KTK_Rockstar 11 месяцев назад +1

    Just curious what your thoughts are on UV dye and leak checking that way

  • @sbnatomicrecords
    @sbnatomicrecords 3 месяца назад +2

    Great info. Its a shame when you have guys add more freon and try to sell it to the customer knowing there is a leak. Smh

  • @user-ni2gf8gb9x
    @user-ni2gf8gb9x 5 месяцев назад +1

    I have had hit or miss with Electronics. It often goes off (all brands) if its near water in the pan , My Inficon goes off in light wind, My field piece just goes off because field piece. lol I almost always have better luck with Nitro and visual with soap bubbles.

  • @markbrown6669
    @markbrown6669 15 дней назад +1

    Great video, my question is if the condenser is grounding out at start up and burning out the fuse do I need to replace the condenser

    • @TaddyDigest
      @TaddyDigest  14 дней назад

      Not sure I would probably need more info

    • @markbrown6669
      @markbrown6669 14 дней назад

      @@TaddyDigest I replace fuses in the electric box to the condenser turn on the system and it start sparking, I shut it off and I had the wiring check and check the fuses again and one of them was shorted out again. I'm not sure if the shortage is because the condenser needs to be replace or if there's something else I can do before replacing the condenser.

  • @bruceelias2732
    @bruceelias2732 Год назад +1

    Thank you sir

  • @user-cb4qd5fc1x
    @user-cb4qd5fc1x 4 месяца назад +1

    😮 damn mans a pro

  • @MetalDetectingwithCZkidd
    @MetalDetectingwithCZkidd Год назад +12

    I would not recommend to anyone to go 500psi on a leak test. I, like Oc have been doing it a long time. Never pressure tested that high, even on the commercial side of things. Can get dangerous. Usually there are operating max pressures listed, I would not exceed those. There is a leak detector that works via sound. I had one of those as well, no matter how small the leak, it would sound like a hurricane in your ears. Nice vid.

    • @MrDeviousdom
      @MrDeviousdom Год назад +1

      500+ psi is where a 410a system is operating during the summer.

    • @MetalDetectingwithCZkidd
      @MetalDetectingwithCZkidd Год назад +2

      @@MrDeviousdom where? If so, clean the coil. Maybe in AZ. Not in FL.

    • @MrDeviousdom
      @MrDeviousdom Год назад

      @@MetalDetectingwithCZkidd In hot areas. I don't understand the point of your comment.

    • @epeterson711
      @epeterson711 Год назад +1

      Agreed! I have never heard of anyone EVER going to 500 psi!

    • @MrDeviousdom
      @MrDeviousdom Год назад +1

      @@epeterson711 well, I'm in AZ and it does all the time on rooftop units.

  • @scottchristian71
    @scottchristian71 12 дней назад +1

    What about the charred wires ?

  • @craigmarshall40
    @craigmarshall40 Год назад +1

    H10 with the long probe

  • @gregstewart8654
    @gregstewart8654 5 дней назад +1

    When you have a fast leak it can be anywhere

  • @tomasavilla1175
    @tomasavilla1175 Год назад +1

    My unit froze up the lines are copper so I turned the unit off so it can thaw from the big ice block so would that problem be from having a leak in the system? Thanks in advance

    • @TaddyDigest
      @TaddyDigest  Год назад

      Could be from leaking refrigerant.
      Could be from a dirty filter.
      Could be from low air flow.
      Just use a process of elimination to figure out.

  • @johnharrisonschulz
    @johnharrisonschulz Месяц назад +2

    How much do you charge for a new evap coil? Here in California it's about $4,500 to replace an evap coil. If it's under warranty, it's about $2,000. Some hvac companies don't even check to see if it's under warranty. I've done two evap coils under warranty this year as a second opinion. The first two companies diagnosed bad evap coils and never checked to see if they were under warranty and quoted the customer about $4,500.

    • @TaddyDigest
      @TaddyDigest  Месяц назад

      wow that is bad
      That is way over priced

    • @salehm1723
      @salehm1723 25 дней назад

      4500$!! That's crazy

  • @jerrysinclair423
    @jerrysinclair423 3 месяца назад +1

    I’ve been using the same leak detector. Had to replace the battery and sensor. Other than that, it’s been a great detector! I’ve also use a H10. A little expensive but what isnt these days?!

  • @jonswisher8796
    @jonswisher8796 Год назад +8

    Most refrigerant leak detectors are incredibly sensitive. If you add any refrigerant you should always do a leak search. A basic leak search only takes 10-15 minutes to make sure you don’t have a good size leak. You don’t have to reclaim the gas and add nitrogen, the refrigerant is the gas you are looking for, and soap bubbles will also blow bubbles regardless if there is nitrogen, as long as there is pressure, don’t complicate it. You can’t give the customer the choice you are supposed to make as a trained technician when it’s such a simple move and avoids callbacks

  • @jonbeck6035
    @jonbeck6035 12 дней назад +1

    Dont forget to pull the disconnect, ive sone that a couple times, best way to learn is to get zaped i guess or just pay attention haaha.

  • @lonestaryall2501
    @lonestaryall2501 Год назад +1

    Mice?? Yuck!! Great job on this system by you!!

  • @TynaGaines
    @TynaGaines 19 дней назад +1

    I'm having this same exact problem with my ac. Guy came out couple years ago and replaced the fan thing on the inside unit and said that would fix our problem. The system will not hold refrigerant. The line constantly freezes up. Definitely don't have $$ for a brand new system. Just need an honest trustworthy HVAC person to look at it and find the leak and tell me if it can be fixed. I'm in Virginia about 50 miles south of DC and 50 miles north of Richmond if you know of anyone in the area you can recommend.

    • @TaddyDigest
      @TaddyDigest  19 дней назад

      You could try some leak Sealant, and u v dye define the leak.
      Check out my video on leak sealant

  • @charlesbarkley1340
    @charlesbarkley1340 10 дней назад +1

    If Steven crowder went into HVAC

  • @tonyrandall6261
    @tonyrandall6261 Год назад +1

    Homeowner must have picked the platinum package, all that he took loose

  • @wow1022
    @wow1022 4 месяца назад +1

    the 3 blind mice met their doom 😂

  • @user-tt3dv6sw2f
    @user-tt3dv6sw2f Год назад +2

    Can an overcharging the system cause the TXV to get stuck closed?

    • @TaddyDigest
      @TaddyDigest  Год назад +1

      Overcharging will definitely to stay closed

    • @user-tt3dv6sw2f
      @user-tt3dv6sw2f Год назад +1

      @@TaddyDigest Thanks for that, the tech told me that the TXV is bad and he need to install a new coil, the system is 3-year-old. I took an image of his 4 port manifold + Micron gauge where it showed the following, on the left side, a pressure of 96.3 Psig below it is 39.1 SH, and below it is 29.5 VSAT. On the right side it shows pressure of 278.8 Psig, 16.8 SC, and below it 90.7 LSAT. I would very much appreciate your thoughts on this

    • @TaddyDigest
      @TaddyDigest  Год назад

      Yeah it looks Like there is too much liquid in The condenser And not Enough Liquid In the evaporator so definitely could be the filter dryer for the t x v

  • @AzizAziz-tp6wd
    @AzizAziz-tp6wd Месяц назад +1

    Good price

  • @JC-sc9rx
    @JC-sc9rx Месяц назад +1

    Tad is solid

  • @RodneyThomas-qk8ce
    @RodneyThomas-qk8ce 17 дней назад +1

    Put your finger in there and see if theres some oil in there lmao classic 😅

  • @guadalupemartinez-mj5ie
    @guadalupemartinez-mj5ie Месяц назад +1

    Technician said had freon leak! On evaporator! $. Ouch! He put leak seal! Looked like a syringe. What are you thought on leak seal. After a month, failed to cool again!

  • @scottygenao2051
    @scottygenao2051 11 месяцев назад +2

    You only put the max on what the system tells you #tag . Especially if you putting nitro on the low side if low side says max250psi you put 250psi

    • @gabooda2380
      @gabooda2380 10 месяцев назад

      there is no way to only put nitrogen in the low side unless you would disconnect the coil.
      But yeah, the coil clearly states design pressure and R22 is very low pressure. I thought last one I saw was 150 on the R22 coil and 450 on 410a coil.

  • @MonsurBakare
    @MonsurBakare Месяц назад +1

    I joined

  • @robertsneed7689
    @robertsneed7689 Год назад +1

    Can I use shampoo as well? Thanks for sharing.

  • @sv1201
    @sv1201 26 дней назад +1

    With the industry going through a major shift to A2L refrigerants starting in 2025, does it make sense to install a current system based on R-410A or wait until next year for A2L systems?

    • @TaddyDigest
      @TaddyDigest  25 дней назад

      If you don't have to replace your system, now I would wait

    • @sv1201
      @sv1201 25 дней назад +1

      @@TaddyDigest I did some research and installers are saying that the new systems might have a price hike of around 30% due to new sensors addressing flammability, tighter standards, etc. Is this true or attempts to sell the remaining inventory?

    • @TaddyDigest
      @TaddyDigest  25 дней назад

      I will figure it out and get back to you

  • @maryschultz645
    @maryschultz645 2 месяца назад +1

    just got a quote for r22 refrigerant at 3 lbs it was over $900 that sounds pretty steep

    • @TaddyDigest
      @TaddyDigest  2 месяца назад

      Dang that is so expensive

    • @maryschultz645
      @maryschultz645 2 месяца назад

      glad i held off especially when theirs apparently a severe leak

    • @centauri8820
      @centauri8820 Месяц назад

      If you look around online you can buy 5lb cans of R-22 for $220. Of course if you have a severe leak don't bother on such an old system and get it upgraded.

  • @jesusnavarrete9213
    @jesusnavarrete9213 2 месяца назад +1

    Can I put pressure in my condenser

  • @user-ni2gf8gb9x
    @user-ni2gf8gb9x 5 месяцев назад +1

    Hay Taddy, Got an unrelated Question, sorry to post on your video. I went to a Goodman PKG HP the other day with Compressor not starting. I could hear it trying like a dead CAP. Checked the CAP (70x5 duel) it was 4.7 on fan and 311 on Herm!! 311/5 wow. Cap was 1.5 yrs old. I replaced it and system began to run. Was pulling 15.5 amps at start then 10 minutes in I noticed it had risen to 18 then ten minutes latter it was near 20. The RLA is 26. I traced the wires and found nothing mis wired to the cap so I called it the Compressor and recommended the Comp. I did not find any strange readings when I did OHM the comp tho before I restarted with the new CAP. Have you seen this before? It is a new one on me.

    • @TaddyDigest
      @TaddyDigest  5 месяцев назад +1

      Is it a 2 stage compressor was it going into high stage? And that's why it pulled more amps
      Or is it just single speed

    • @user-ni2gf8gb9x
      @user-ni2gf8gb9x 5 месяцев назад

      @@TaddyDigest Single speed

    • @anthonybernier9952
      @anthonybernier9952 3 месяца назад

      The capacitor can read higher but if you look at your meter its nano farads so its actually lower.

    • @anthonybernier9952
      @anthonybernier9952 3 месяца назад

      ruclips.net/video/cZUpCEbIRow/видео.htmlsi=v8283FCc_UPzLQoh

  • @Chunkylifehealthyfuture
    @Chunkylifehealthyfuture 11 месяцев назад +1

    I have that noise coming out of my central vent when the AC is off. Does anyone know what's wrong with my AC? It works fine. Just that sound is lingering after it's off.

    • @hhn2002
      @hhn2002 10 месяцев назад

      I’m not professional but just a guess it maybe the high and low side pressures equalizing which would be a normal thing.

  • @VooDooWarrior01
    @VooDooWarrior01 Год назад +1

    Guys here tried to charge me over $1500 just to put $75 leak sealant in, so I got my 608 very and work on my system myself.

  • @christianlara9918
    @christianlara9918 Год назад +3

    I have used multiple bacharach h10s and various other refrigerant leak detectors. I have NEVER found a leak with any of them. I always find them with bubbles, sound, and oil spots. What leak detector do you use?

    • @chrismyers5758
      @chrismyers5758 Год назад +1

      I have never found a leak with bubbles only leak detectors

    • @MrDeviousdom
      @MrDeviousdom Год назад +2

      That makes absolutely no sense as the h10 picks up leaks that are so small they don't even create bubbles. You might want to revisit your technique and or have the equipment checked.
      The H10 includes a calibration vial of R11. Make sure it's calibrated properly.

    • @donaldallen743
      @donaldallen743 Год назад +1

      I've found some leaks with the NAVAC.

    • @OcRefrig
      @OcRefrig Год назад

      @ Christian lara
      Ive been doing Leak detection with a Ge H-10G Leak detector for 42 Years & it WILL Get you Right to a leak EVERYTIME.
      THE Problem is With YOUR Leak detector or YOUR Technique Period !
      Basics of Leak detection with a Ge/Bacarach H10G Leak detector.
      1) Plug detector in.
      2) turn on.
      3) set switch to Medium. Turn dial left until no clicks are heard during warm up.
      4) Let detector warm up for 5 Minutes on the clock. Then adjust dial till clicks are heard every 1 second.
      5) bring probe tip across top of Sample bottle & hold for 1 second. Leak detector should scream loudly. If not.
      Set Switch to SMALL. Adjust dial to clicks ever 1 second. Try again. Wave probe tip over sample bottle / reference leak detector test bottle included in every ge H10 leak detector.
      It should scream loudly & Red led should be flashing madly. IF Not Leak detector NEEDS Adjusted / Sent in for Service.
      If Leak detector works / Tests out good Here is Basic technique of Leak detection -
      1) System Must Have 25 Psi of Refrigerant in it Min. Then -
      2) Add 150 psi of Dry Nitrogen to System being checked.
      3) Test that both Sides of the System have a Min Pressure of 100 -150 Psig in the System.
      4) Allways check that Leak detector works before starting leak detection procedure with test vial or at refrigerant tank briefly. Once detector is known functional then & only then can leak detection start.
      5) Start with Ge H10 Leak detector in Medium position , set click rate of 1 click per second & Bring leak detector Near Evaporator or Condenser.
      To check for leaks.
      6) the H10 is designed to be moved across an area at a Rate of 1” per second.
      7) DO NOT LET IT SUCK UP WATER / Keep it away from water. It is a Pump that WILL SUCK up water and it will instantly Junk out the Leak detector.
      8) if you get the probe tip wet - Change the white probe tip filter with the filters provided.
      9) Remove plastic probe tip & dry out with paper towel or rag.
      10) Replace Red Floating ball 🏀 that is in Probe Plastic tip. ( it shows you that Pump is sucking air )
      11) install New dry white Filter into probe tip.
      12) install Rubber tip on probe & start again.
      13) Warm up Detector, set to medium, Keep probe tip moving at a rate of 1” per second & try to keep it away from water & soap bubbles. Keep approx 1-2” away from wet surfaces.
      This should get u started.

  • @stephwaylonwells3218
    @stephwaylonwells3218 Год назад +1

    👍

  • @tomoliver8498
    @tomoliver8498 Год назад +3

    You should be able to wet your bare hand and feel for the leak better

    • @OcRefrig
      @OcRefrig Год назад +1

      Yea, spray some soap bubbles on it. You can feel bubbles with your fingers really easily & it makes bubbles when you pass over the leak with your fingers.

  • @salehm1723
    @salehm1723 25 дней назад +1

    How would you purge the nitrogen later?

    • @TaddyDigest
      @TaddyDigest  24 дня назад

      not sure

    • @geoffhart
      @geoffhart 17 дней назад

      @@TaddyDigest What? Didn't you complete the repair? I presume you had to evacuate the entire system, then refill.