  • This video covers how to hang, install and mark out a column radiator. It also includes vertical radiators. We cover the removal of the old radiator, the marking of the wall for wall plugs. The drilling of holes for the brackets. The fixing of the brackets and the hanging of the column radiator. We even show you how to pipe it up in copper pipe and solder end feed fittings.
    🚀 LEARN PLUMBING ONLINE IN MY STRUCTURED COURSE (50% Before March): www.learnplumbingonline.com
    🛠 AMAZON TOOL STORE: www.amazon.co.uk/shop/plumberp...
    🥾 10% Off my workboots + workwear Use Plumberparts10: www.bigboots.co.uk/discount/p...
    👓 10% Off Safestyle Sunglasses Use PLUMBER10: safestyle.com.au/?ref=PLUMBER10
    Learn Plumbing Online is perfect for future apprentices, homeowners who want to understand and tackle more plumbing jobs in the home, handymen who keep turning down the odd plumbing job and more. With practical follow along video lessons and discussion board you can boost your knowledge in my amazing trade. Sign up now: wwwlearnplumbingonline.com
    **VISIT OUR SPONSORS**
    www.traderadiators.com | www.stuart-turner.co.uk
  • ХоббиХобби

Комментарии • 177

  • @plumberparts
    @plumberparts  5 лет назад

    Still uploading today! *_Links to the tools I use everyday here:_* www.amazon.co.uk/shop/plumberparts
    *_Plus, follow my Vlog “TimesWithJames”:_* ruclips.net/user/timeswithjames

  • @1506pinkers
    @1506pinkers Год назад +2

    I wish I found plumbing as much fun as you obviously do. Great video. Thanks.

  • @dokkari
    @dokkari 6 лет назад +2

    Great professional and good sense of humor

  • @SuperrJordy
    @SuperrJordy 11 лет назад +1

    started watching your videos today because I'm starting a plumbing course Monday, you're brilliant! Keep up the videos haha! "go on, eat ya dinner" love it!

  • @Balls-real-
    @Balls-real- 2 месяца назад

    I don’t even care about pluming but that thumbnail was art so hear I am

    • @Balls-real-
      @Balls-real- 2 месяца назад

      Just finished watching the video. Bro is hilarious I’m ducking subbing

  • @Devtherev999
    @Devtherev999 6 лет назад +3

    Picked up loads of tips from your videos, cheers! Struggled with ptfe tape time and time again, that loctite 55 is the nuts and I now get a good seal first time every time! Nice one!

  • @wrrrww
    @wrrrww 2 месяца назад

    Thank you very much for your help. I'm ready to instal my new radiator by myself.

  • @peterduffy8355
    @peterduffy8355 9 лет назад +1

    DIYPETE
    Watched the video a couple of times before fitting a column radiator did as you showed everything went fantastic also used the same screw fittings as shown in the video had no problems with them. Thank you

  • @jamiewatchorn7639
    @jamiewatchorn7639 6 лет назад

    You’re awesome. Wish all tradesmen were as fun as you

  • @woodbine66
    @woodbine66 11 лет назад +1

    More quality videos.
    You're the man!! Barking mad, but still THE MAN!!!!!!!!!!!!!!

  • @AlanCooney
    @AlanCooney 4 года назад

    Great video! I put one of these on a dot'n'dab hollow wall - had to recess wooden blocks to bridge gap between plasterboard surface and bricks behind. Used long "bolt head" screws through the wooden blocks into the brick. Job done!!...these radiators are just really really heavy. Bo' Selecta!

  • @darrenfreeman4936
    @darrenfreeman4936 11 лет назад +3

    i've never installed a collum rad, thank you for showing us, same principles as a panel rad. Not the most effecient rad but they do seem more classy. Im sure you could double the efficiency by stuffing wire wool between the collumns, not sure if they'd look as great though. Cute cat!

  • @addz91
    @addz91 11 лет назад

    Top video fella!

  • @anoshya
    @anoshya 4 года назад

    Very good instructions...

  • @EIRONA
    @EIRONA 3 года назад

    Great video.
    Most of these column radiators have inlet and outlets. My inlet and outlet stickers have been pulled off by my 2 year old. Any ideas if you can look inside to differentiate?

  • @ChrisMcKeown560
    @ChrisMcKeown560 7 лет назад +2

    Had to pause and comment at the Don't Mug Yourself reference. Carry on.

    • @plumberparts
      @plumberparts  7 лет назад

      Ha! Cheers dude!
      SUBSCRIBE! ➡️👉 ruclips.net/user/plumberparts
      ➡️👉FOLLOW US ON TWITTER 🐤👉 twitter.com/plumberparts 👈🐤

  • @opentrail
    @opentrail 7 лет назад +1

    i love watching your vids. Pro @work.

    • @plumberparts
      @plumberparts  7 лет назад

      Ha! Thanks dude!
      SUBSCRIBE! ➡️👉 ruclips.net/user/plumberparts 👈⬅️ IF YOU HAVEN'T ALREADY! 😎

  • @khaledgirgirah1814
    @khaledgirgirah1814 4 года назад

    Amazing video. Can I ask plz, what type and size screws do you recommend to fit
    Milano Aruba Flow - Vertical Oval Column Designer Radiator
    Thanks

  • @paulevoque1132
    @paulevoque1132 3 года назад

    Hi James love your videos, I'm sure I've seen one where you replaced a rad with a plumbed towel rail using the existing valves/pipework - but cannot find it - is it still available? Really looking for help in measuring up using the 90 degree dual fuel elbows and how this will effect the height in relation tothe brackets to hold the towel rail on the wall?

  • @chrisball3634
    @chrisball3634 3 года назад

    Hi...i fitted a double aluminum tower rad. In my bathroom. Like you was concerned about the weight. The internal wall is breezblock. So, made up a box for the rad to sit on. It hangs on the top brackets, rests on box which takes the weight. There is one bracket in the middle of the rad. at the bottom, which stops any vert/horiz. movement. Holes are drilled at the back of the box for vent. Box then covered in carpet. Looks good.

  • @mjhmotorsport
    @mjhmotorsport 2 года назад

    Great video thanks

  • @bobsy852
    @bobsy852 5 лет назад

    I'm hanging my first column rad in the next couple of weeks. I've taken the old rads off, no issue. I was hoping to just connect them to the existing pipework though, after fitting new TRV's and some telescopic radiator tails? I'm no plumber so was hoping to avoid altering pipework. I notice you ended up having to alter the pipe to the right hand side of this rad though?

  • @tecnologiaoficial
    @tecnologiaoficial 7 лет назад

    LOL it's the weekend!!!!!!!! Have a nice one too :)

  • @danielbrannigan6532
    @danielbrannigan6532 5 лет назад +2

    Can it be risky having the valve / compression fitting, close to a pulled bend or offset?

  • @estebanalzu703
    @estebanalzu703 8 лет назад

    Good job mate! How about the water pressure? Before & after to cut the pipe.

  • @shaunbeard593
    @shaunbeard593 6 лет назад

    Hi I hope you can help. I understand about feed pipe being 22mm then branching to 15 but what size for return. Thanks

  • @tomgreen5785
    @tomgreen5785 8 лет назад

    Great vid as ever. What are those wall fixings you used for the crappy wall? FANKS!

  • @Glittlejohns1
    @Glittlejohns1 6 лет назад

    Hi buddy, i want to tap off from a hallway radiator into a bathroom radiator-sort of a leg- just flowing around the bathroom rad back into the F and R for the hallway rad. Is this as simple as it sounds and do i need to plumb it in any particular way (given that TRVs are bi-directional)? thanks..

  • @ryanmcewan4147
    @ryanmcewan4147 7 лет назад

    Any advice for installing column radiators on plasterboard or ply walls???

  • @wgenerotzky
    @wgenerotzky 6 лет назад +1

    Do you ever work with cast iron radiators? The radiators I install here are mostly cast iron floor standing units.

  • @nman2563
    @nman2563 6 лет назад

    Great video! You don't like installing them because they are not as efficient as panel radiators?

  • @trailblazernz7490
    @trailblazernz7490 11 лет назад

    Makita with a light.... Stabila it's da best......no leaks coz your amazing and you work really fast specially on the pipes. Job well done, loved it..hang loose!

  • @Moistifying
    @Moistifying 7 лет назад

    Hi. Do you have video how to close water - (cold and hot) wich is coming in to radiators?

  • @1spiders1
    @1spiders1 3 года назад

    Hi mate these radiater Tod they warm up good ?

  • @zakiadam6870
    @zakiadam6870 6 лет назад

    Hi mate. What is the safety way to fit Worcester gas boiler on the plasterboard. Thanks.

  • @ratilalhirani6675
    @ratilalhirani6675 9 лет назад

    hi
    I have a mega flow system but want to add a radiator in my home .. what is the procedure to do this. I had a gravity system before which i knew how to refill, but i am unsure with this mega flow system.
    please help
    many thanks!

  • @zackkarim3442
    @zackkarim3442 4 года назад +1

    I watch your videos all the time I have learnt a lot of things from you thank you very much only one thing I couldn’t understand the pipe bend to the radiator you could a go straight from the ground because you already lifted the floor

  • @nigelhobden
    @nigelhobden 2 месяца назад

    Do these vert rads all need flow diverters fitted, as we've got all verts & I'm wondering if this is why we aren't getting all rads hit aswell as semi hot.

  • @petersutton3054
    @petersutton3054 4 года назад

    Hi is there a right way up or can you fit any way

  • @steowong
    @steowong 8 лет назад +2

    your pipework is a joy to watch. Pipe Art :)

    • @plumberparts
      @plumberparts  8 лет назад +1

      +steowong Cheers mate!
      Sub here please>> ruclips.net/user/plumberparts

  • @nbashir786
    @nbashir786 2 года назад

    How do you balance the hot water flow, as one of my column rads stays completely cold. Thanks

  • @kellybooth1884
    @kellybooth1884 3 года назад

    Hi do you have any videos on all the boys you time lapsed. I'm needing to learn how to move and then connect the pipes please x

  • @daraghevans7637
    @daraghevans7637 4 года назад

    In the end you didn't use the pipe with the trv you had to cut it out, what happened was that because the pipe needed a slight off set in the end. I fit 3 of them a few weeks ago it's always a pain matching upto existing pipes. Nice job as usual

  • @carolwalsh4187
    @carolwalsh4187 4 года назад

    How do you move the pipes if they are built in the wall
    I need to get a smaller radiator but dont know how to move the pipe work with it being in the wall
    Thanks

  • @Falco45able
    @Falco45able 5 лет назад +5

    Self levelling laser level required!

  • @raj080288
    @raj080288 2 месяца назад

    What's the foam for on the pipes under the floorboards?

  • @calummorell9589
    @calummorell9589 6 месяцев назад

    Is it possible to run the water pipes through a wall into these. So the inlet and outlet would 90 degrees to what the are here?

  • @nathanielthomas8692
    @nathanielthomas8692 9 лет назад +2

    Nat Thomas
    just watched your how to hang a column rad. MINT! just as all of your vids I've watched are. Because I am a rookie plumber I like to watch the piping bit in real time. the soldering, bending and measuring. could you include this in future vids please? a suggestion could be notching. Hold tight!

  • @lafemmelaMon
    @lafemmelaMon 6 лет назад

    Great if you can lift the floorboards, what if you have another wood flooring on the top of the boards so you can't lift? Is there any other way to shift the pipes? I think I know the answer... :/

  • @bmulli12
    @bmulli12 Год назад

    Can these shape radiators be hung the opposite way up, say with the inlet and outlet coming in from the top
    I ask as I tend to have one and the pipes come from above, so would I have to run the pipes down to come in the bottom of the radiator?!!!

  • @chazshier
    @chazshier Год назад

    Do the spiggates need to be in as tight as possible?

  • @kevinhancock4064
    @kevinhancock4064 3 года назад

    Is that copper connected to plastic piping or onto copper ? I know often plastic is used these days I can of course see its copper to the rad good work mate tidy stuff

  • @shaneyoung1690
    @shaneyoung1690 24 дня назад

    Nice

  • @DaddyBear3000
    @DaddyBear3000 7 лет назад +3

    Would have been good to get a close up on how you got the bends on the pipe once you got them below the floor.
    Love your vids bro and love the look of column radiators as well, but not great on BTU's for their size.

    • @titilayoolowu4523
      @titilayoolowu4523 7 лет назад

      All cellar of soak com 1500x290mm white double panel vertical colosseum traditional radiator premium p23755498 htm

  • @jonathonstanley5811
    @jonathonstanley5811 6 лет назад +4

    I'm not a fan of hanging these radiators I don't no why they don't come with a template to make our lives easier

  • @Norwichjase
    @Norwichjase 4 года назад

    We’ve fitted a column radiator and only half of the rad is heating up.... any thoughts

  • @MarcGray1990
    @MarcGray1990 10 лет назад

    Hi mate could you possibly do a video in more detail of how u measured up for the offset bends you did in this video as I'm trying to get to grips with working out measurements when bending pipe! Cheers mate

    • @plumberparts
      @plumberparts  10 лет назад

      I'll pop it on the list! Cheers, PP!

  • @khardle
    @khardle 10 лет назад

    Hi there. Love your videos but the bits you timelapsed and cut from your towel rail vid were the bits I really wanted to see :-(. I have an old Victorian house, but in the bathroom the pipework runs at right angles to the joists. I need to replace a huge old radiator with a smaller radiator / towel rail combi without notching out the joists. Radiator is also earthed - I've not seen this in your videos. Any advice on how to proceed would be appreciated. Maybe flexihoses and box in above floor pipework? Cheers! Kirsty x

    • @plumberparts
      @plumberparts  10 лет назад

      Hi Kirsty, can you show us the problem here at Google Helpouts? helpouts.google.com/101344000685454855058

  • @GasmanChris5705
    @GasmanChris5705 2 года назад

    Be great if manufacturers put a fixing template in with radiator? Works for boilers 👍

  • @luke3917
    @luke3917 2 года назад

    Thanks. I like your videos. 7:34 mins into the video. What was that hanger in the door jam for. You never showed us. :-)

  • @piggybakkers
    @piggybakkers 6 лет назад

    Bloody hell you are good! how did you know my uncle Bob?

  • @SoundSoCollective
    @SoundSoCollective 10 лет назад

    Plumb Bob ... i still use lol

  • @rayduffy6172
    @rayduffy6172 3 года назад

    When hanging the radiator do you need to pitch it slightly towards the feed pipe so it will run back into the pipe when cooled so you won't get air in the pipe causing noise? Thanks, Ray

  • @phillipbull3673
    @phillipbull3673 7 лет назад +1

    dot and dab wall...lovely

  • @metratone5
    @metratone5 4 года назад

    Does anyone know why after trying to drain my central heating system the radiator that I am trying to change still has water coming out of it.

  • @peterryan7827
    @peterryan7827 Год назад

    We had two of this type fitted in a new extension, he worked out the BTUs,s but they are basically crap. They take far too long to heat up.and even when they are hot the room is just not hot enough, Question one is there a top and bottom ,and somebody mentioned to me about a gate thats just inside the rad valve entry point that has to be opened before installation ,allowing the water to flow to the top of the first section then slowly drop down to all the sections ,any comment would be handy ,personally i wany to take one of them out and replace it with a conventional rad ,but wifey is not happy because it means a pipe showing on the skirting because the new floor covering would be a nightmare to lift,.

  • @moovintruespace994
    @moovintruespace994 4 месяца назад

    Hi. Why did you put those little L bends in the pipes, is that just for aesthetics?

  • @FREEDOMFIGHTERX141
    @FREEDOMFIGHTERX141 2 года назад

    I have one of these radiators fitted recently in my identify plan kitchen everytime I open my sink in bathroom downstairs and slide it a few seconds later if u go next to the radiator it makes a bubbles water noise fir a few seconds. This is the same if I open and close my sink in kitchen. I've had a new boiler installed a week ago. Anyone know what cud be the reason if of my issue and a solution please.

  • @tdar91
    @tdar91 2 года назад

    I’m an apprentice n the scariest part to me is drilling holes through the walls, especially if it’s plaster bored walls and have to use them different screws I don’t even know what they screws are called hahaha all come in time it will. Toppa video mate

  • @TheDophler
    @TheDophler 11 лет назад

    U get some handy jobs i tell ya lol

  • @brianbenson7390
    @brianbenson7390 8 лет назад

    Hi can you hang these radiators with the pipes coming down from the ceiling or do they have to come up from the floor??

    • @plumberparts
      @plumberparts  8 лет назад

      +brian benson Yep, should work fine.

  • @dilligaf2386
    @dilligaf2386 5 лет назад

    6ft level would be handy for vertical marking up

  • @moaizamrazakhokhar4042
    @moaizamrazakhokhar4042 9 месяцев назад

    Hi, can I ask you a quick question? I did install three new vertical radiators downstairs. Two of them take ages to get warm (one in the kitchen and the other in the sitting room, it is mid terrace house). What advice you can suggest?

    • @andrewgriffiths5161
      @andrewgriffiths5161 5 месяцев назад +1

      Probably a bit late now but you need something called a 'flow diverter' which forces water to the top of the rad.

  • @Th3M4nd3M
    @Th3M4nd3M 7 лет назад

    Can you send me the link where I can purchase the same or similar wall brackets please! Thanks!

    • @plumberparts
      @plumberparts  7 лет назад

      Pop over to TradeRadiators! SUBSCRIBE! ➡️👉 ruclips.net/user/plumberparts 👈⬅️ IF YOU HAVEN'T ALREADY! 😎

  • @amirhussain1449
    @amirhussain1449 9 лет назад +1

    Hi pp I would like to see you doing the offsets you did and the bending pipes cheers pp

    • @joshallan17
      @joshallan17 9 лет назад

      there are vids about offsets mate, unless you mean on very short pipe?

    • @amirhussain1449
      @amirhussain1449 8 лет назад

      +Reginald Tinkleberry who would recommend

  • @alejandrojara9287
    @alejandrojara9287 Год назад

    Hi, I installed a column radiator of the same brand a few days ago. What i saw is that the bottom was hot just after starting the system but 40min later the top was still cold. I am considering running the hot pipe all the way to the top port to have the feed the furthest away possible from the outlet. Its kind of a problem as i already did the holes on the wall and an exterior pipe at eyes heigh will not look good (specially with the big thermostatic valve there at the top) but otherwise it looks absolutely inneficient. Have u not had this problem?

    • @flaviokonti5522
      @flaviokonti5522 9 месяцев назад

      You need to let the air out at top while your slowly filling it with water. If its full of air then water cant come in all the way to the top

  • @slawrence62
    @slawrence62 7 лет назад

    Love the vids great stuff, but why did you measure the right pipe then cut it and replace ??

    • @plumberparts
      @plumberparts  7 лет назад

      Can't remember...it was years ago! SUBSCRIBE! ➡️👉 ruclips.net/user/plumberparts 👈⬅️ IF YOU HAVEN'T ALREADY! 😎

    • @rowerwet
      @rowerwet 5 лет назад

      Probably to get it above the mopboard

  • @topiaskauppinen3677
    @topiaskauppinen3677 7 лет назад

    Thank you for explaining how to do. Also Do you usually measure in cm or inch in UK?

    • @plumberparts
      @plumberparts  7 лет назад

      CM in the UK mate. SUBSCRIBE! ➡️👉 ruclips.net/user/plumberparts 👈⬅️ IF YOU HAVEN'T ALREADY! 😎

    • @topiaskauppinen3677
      @topiaskauppinen3677 7 лет назад

      Thank you. If one does not ask one does not know ;-).

    • @topiaskauppinen3677
      @topiaskauppinen3677 7 лет назад

      Thank you. If one does not ask one does not know ;-).

  • @tdgg3164
    @tdgg3164 5 лет назад +1

    I've just put one of these in but I have muddled up the flow and return, so the pipe that gets hot first is going into the return side. When on the rad makes a trickling noise and dosent work properly, will this be sorted if I flip the pipes. Cheers.

    • @Tony91177
      @Tony91177 3 года назад

      yes

    • @tdgg3164
      @tdgg3164 3 года назад

      @@Tony91177 it just needed massively bleeding, the pipe direction seems to mean absolutely nothing.

    • @Tony91177
      @Tony91177 3 года назад +1

      @@tdgg3164 I had this Monday. Hung 4 new radiators. all the same just different sizes. Two had a inlet and outlet sticker on them, the other two didn't. one of the ones that didn't just would not get hot. I kept bleeding it and raising the pressure and balancing the others, then eventually after about 25mins of this it started to get hot. Really strange! Worked in the end but I was thinking maybe this was also directional even though there was no stickers on it.

  • @chiefgilray
    @chiefgilray 7 лет назад

    alright mate, I have a problem, I am installing all my radiators myself but I am having the pipes come out the wall. the problem is I am using chrome piping but I am struggling to tighten the pipes without the pipe kinking ever so slightly just after the nut and they keep leaking when I pressure test as well. is there a special sequence/trick to tightening the pipes without twisting the pipe?

    • @plumberparts
      @plumberparts  7 лет назад +1

      Try and use a little jointing compound on the nuts.... SUBSCRIBE! ➡️👉 ruclips.net/user/plumberparts 👈⬅️ IF YOU HAVEN'T ALREADY! 😎

    • @chiefgilray
      @chiefgilray 7 лет назад

      plumberparts cool, I'll go out and get some, I think I will replace all the chrome piping as well as it doesn't look great as is.
      thanks for that

  • @stevecullen9411
    @stevecullen9411 8 лет назад +8

    slightly dissapointed I didn't get to see the moggy finish its dinner but other then that pretty informative.

  • @undaya
    @undaya 4 года назад

    just luverly

  • @bigheadface5093
    @bigheadface5093 5 лет назад

    Help me pass my on site assessment!

  • @RomeoKGT
    @RomeoKGT 6 лет назад

    Fortunate you can lift the floorboards. I have an old type 11 radiator thats 2m in length and I want to change to type 22 and reduce the size to 1600mm and still have more Btu. Problem is the pipes are in the wall and its the 8mm copper type from the 80's

  • @smithboyv1
    @smithboyv1 5 лет назад +2

    All the vertical radiators I've purchased recently have metal filings still inside them that you can hear when tilting the radiator, which I can't seem to flush out.
    Any one else have this issue?

    • @gannas2322
      @gannas2322 5 лет назад

      smithboyv1 yea can be a major problem. I fitted a whole house out with Delonghi coloumn rads and all the enamel inside kept flaking off when the heating was running. You could here it pinging off inside! I had to powerflush the system in the end, but it was a nightmare! Last time I have fitted Delonghi coloumn rads btw!

  • @TelfLad
    @TelfLad 7 лет назад

    those walls are fiiiine

  • @abdullahnawaz1908
    @abdullahnawaz1908 8 лет назад

    +plumberparts can you make basic vids like basics to more complex pls start from

  • @kingswaydriving-richardkin9741
    @kingswaydriving-richardkin9741 7 лет назад +1

    My problem is that my floors are sheet MDF rather than floor-boards. Also the radiator feeds are flexible plastic pipe, coming out from the plaster-board wall...

    • @plumberparts
      @plumberparts  7 лет назад +1

      You'll need to by an oscillating cutter (or Fein) that'll get you in in no time!

  • @ImranHussain-tn5xm
    @ImranHussain-tn5xm 2 года назад

    What is the height you should hang rads on wall

    • @nobodydoesithalfasgoodasyou
      @nobodydoesithalfasgoodasyou 2 года назад

      You want the top to be at least one half the width of a king size duvet cover above floor level

  • @roblawrence6884
    @roblawrence6884 11 лет назад

    All good! but what happened to filming AAV's? Got my own little AAV problem and need a tutorial. :)
    You've gotta be running out of plumbing scenarios soon fella!!

  • @MrWitoldK
    @MrWitoldK 7 лет назад +2

    You are funny mate ;-)

  • @Cumbriahandyman
    @Cumbriahandyman 11 лет назад

    What did you do with all that money?
    As always, great vid.

  • @fablan3308
    @fablan3308 Год назад

    Sometimes it's hard to find the right size radiator
    To replace an old I've got 640 old one thought I was going to be able to do myself but I might need to get
    Because the pipes my need moving

  • @kirby2kirby
    @kirby2kirby 4 месяца назад

    Struggling with a small rash/ sore on my helmet. I’ve been told organic yogurt is the way to go? Can you confirm?
    Hold tight

  • @elliott4562
    @elliott4562 5 лет назад +1

    You did everything perfect except the bottom brackets face down to stop radiator from coming off the wall they're very tricky to fit ..You do the top brackets first hang rad on them loosely fit the bottom two brackets and you go in from side with a spanner and tighten bolts ..with both brackets facing up the radiator potentially could be knocked of the wall with upward force

  • @LDPDFRPOLICE
    @LDPDFRPOLICE 8 лет назад +3

    "Theres not gonna be any leaks cause im amazing" - I think I love you bro (not gay)
    Love your videos pal. Started looking at plumber videos cause I smashed my radiator pipe with the vacuum cleaner and it leaked bad. *cry*
    Hold tight :D Also, you're pretty handsome (still not gay)
    Cheers!

  • @gc19901
    @gc19901 6 лет назад +4

    telling a cat what to do. that'll never work. oh yeah and hold tight

  • @Marty7787
    @Marty7787 11 лет назад

    Both valves need turning off. If you're not confident then as the rad will be full of water, disconnect one side first and drain the radiator to make it easier.

  • @CurvedSlightly
    @CurvedSlightly 10 лет назад

    Dude, why no chrome pipeage! Looks way cooler with chromeage! However, I would like to 'big-up' yourself.

  • @charliefarlie6469
    @charliefarlie6469 4 года назад +3

    I think that your vids are amazing although I can’t understand a word , ( perhaps you could do subtitles ? )
    Lots of love and best regards from north of Watford gap 🤪 .

    • @plumberparts
      @plumberparts  4 года назад +1

      Shmeeerrrr.....danke!

    • @charliefarlie6469
      @charliefarlie6469 4 года назад +4

      plumberparts LOL , funny guy , I’ve noticed that you and Bradley Walsh are never in the same room at the same time, Hmm ,