Dyson V8 - brush not spinning - PCB repair

Поделиться
HTML-код
  • Опубликовано: 28 авг 2024
  • If the brushes no longer work, it is possible that the problem is caused by the failure of the MOSFET that is responsible for powering the motorized accessories. This vacuum cleaner model (Dyson V8) contains a MOSFET M13C30/ PSMN013-30MLC (N-channel 30 V 13.6 mΩ logic level MOSFET).
    In this case, replacing this MOSFET solved the problem.

Комментарии • 53

  • @jameslarson6555
    @jameslarson6555 8 месяцев назад +7

    Excellent video, really good camera work, really appreciate the time and effort it took to make this!

    • @techfixPOV
      @techfixPOV  8 месяцев назад +1

      Thank you very much!

  • @MrMshabtai
    @MrMshabtai 2 месяца назад +1

    Thanks a lot , realy helped me to repair my v8 Dyson with this problem - Aliexpress - 1.2 EUR per 1 MOSFET plus "small" work

  • @adambikes65
    @adambikes65 Год назад +2

    Nice one, thanks for listing the MOSFET needed

    • @techfixPOV
      @techfixPOV  Год назад

      Thanks, I'm glad if it helps.

  • @LukeAquilina
    @LukeAquilina Год назад +1

    I had previously just jumpered this mosfet to get it working, but thank you so much for the part number! Finally wanted to go in and complete the repair since the shorted mosfet drew a lot of current draining the battery quickly.

    • @techfixPOV
      @techfixPOV  11 месяцев назад

      Yes, it would be ideal to replace the mosfet with a new one. I'm glad the video was helpful.

  • @tiromancino_tt
    @tiromancino_tt 5 месяцев назад +1

    great job !

  • @donjciii
    @donjciii 9 месяцев назад

    Howdy and thank you for creating the video! What microscope do you use?

  • @egghead5019
    @egghead5019 10 месяцев назад +1

    How did you get the new MOSFET to stick/solder on the board? Are you using the existing solder that was left on the board from the prior MOSFET?

    • @techfixPOV
      @techfixPOV  9 месяцев назад

      It's better to replace the old solder with a fresh one (leaded solder).

  • @mydangkaraoke
    @mydangkaraoke 10 месяцев назад +2

    Thank you

  • @karlrichards1611
    @karlrichards1611 4 месяца назад

    Awesome video. Question for you that blue wire that you unclipped with white end from mother board, where does the other end of it go to and what is it for?
    Does it just go through that rubber sleeve tube and wrap around and stick into the sleeve tube just above it ?
    Thanks and great break down u😮😮

    • @techfixPOV
      @techfixPOV  4 месяца назад +1

      The blue wires are connected to a Reed sensor. This sensor closes a circuit when the power selector is in the MAX position.
      The button has a small magnet applied that activates this Reed sensor. The Reed sensor is a glass bulb that contains two contact blades that change their position when they are in the presence of a magnetic field.

  • @andreyanart148
    @andreyanart148 5 месяцев назад

    Thanks for video. I've got v10 with same problem. And checked MOSFET and it seems ok. Hope for help. Thanks

    • @techfixPOV
      @techfixPOV  4 месяца назад

      I recommend that you completely disassemble the electronic board and check it on both sides of the liquid. There are several points on the back of the board that can be very easily affected by liquid and generate this defect that you are complaining about.

  • @Snowzor
    @Snowzor 10 месяцев назад +1

    Bro please do a video for Dyson v12 slim there is no video for this 😢 usually the issue is you have to press many time button on to make it work

  • @philippephilippe8963
    @philippephilippe8963 Месяц назад

    Ok , mais quelle est la référence des MOSFET ?

    • @techfixPOV
      @techfixPOV  Месяц назад

      Please read the video description.

  • @muttalippnarbas9262
    @muttalippnarbas9262 3 месяца назад

    Hello. Do you know the output voltage and amperage values ​​for the ground head motor on the board? Could you please answer?

    • @techfixPOV
      @techfixPOV  2 месяца назад

      Can you be more specific? I don't know which motor you are referring to.

    • @muttalippnarbas9262
      @muttalippnarbas9262 2 месяца назад

      @@techfixPOV Volts and amperage from the DysonV8 type Vacuum motor driver board to the floor nozzle brush motor?

    • @AnnaVannieuwenhuyse
      @AnnaVannieuwenhuyse 16 часов назад

      @@muttalippnarbas9262 Battery voltage

  • @mrzabie0138
    @mrzabie0138 5 месяцев назад

    Hello, my V7 model looks like the same board. Mine overloads and cuts out on high speed. Do you have any thoughts on what might be causing that? Thanks!

    • @techfixPOV
      @techfixPOV  4 месяца назад

      Does it stop when you use the MAX button? Try without filters installed. If it works normally without filters, you should clean or replace the filters.

    • @mrzabie0138
      @mrzabie0138 4 месяца назад

      @techfixPOV Thanks for the reply. It doesn't work even when the filters are out. I called Dyson and they said it was most likely a bad motor and since it is discontinued, they don't support the model anymore and don't have parts.

    • @AnnaVannieuwenhuyse
      @AnnaVannieuwenhuyse 16 часов назад

      @@mrzabie0138 If your vacuum is a little older by now, try a different battery. They wear out fairly quickly due to the substantial abuse they need to tolerate to supply a powerful motor. Cutting out and/or lasting very briefly is a symptom common with worn out batteries, which develop a high internal resistance and cause a substantial power loss that causes the system to cut out to undervoltage protection.

  • @electronicaaran2796
    @electronicaaran2796 7 месяцев назад

    Hello, what type of mosfet is it? thank you

    • @techfixPOV
      @techfixPOV  7 месяцев назад

      The MOSFET is M13C30/ PSMN013-30MLC (N-channel 30 V 13.6 mΩ logic level MOSFET).

    • @Sama_09
      @Sama_09 5 месяцев назад

      Is that same for v11 too ??

  • @lartist-jk8fp
    @lartist-jk8fp 3 месяца назад

    But it only happened with one of the attachments, not all of them.

    • @techfixPOV
      @techfixPOV  3 месяца назад

      If only one of the brushes doesn't work, it means that that brush needs to be checked.

  • @dennismartin5041
    @dennismartin5041 Год назад

    what did you use to de-solder the mosfet chip ? Is this a heat gun and what was the solution that you applied to remove the solder from the chip?

    • @techfixPOV
      @techfixPOV  Год назад +2

      I used a hot air soldering station, both for desoldering and for soldering. Temperature 400 degrees, airflow at half power. The applied solution is AMTECH flux.

    • @dennismartin5041
      @dennismartin5041 Год назад

      @@techfixPOV thank you

    • @donjciii
      @donjciii 9 месяцев назад

      ​@@techfixPOVThank you!

  • @antoniosanchezfra
    @antoniosanchezfra 6 месяцев назад +1

    👍

  • @Sama_09
    @Sama_09 4 месяца назад

    need one for v11 !! if you want a test piece i can mail you mine !!

    • @techfixPOV
      @techfixPOV  4 месяца назад

      I will try to make a video with the V11 model as well. I think I have one that has this problem.

    • @Sama_09
      @Sama_09 4 месяца назад

      @@techfixPOV that is awesome

    • @benf.7158
      @benf.7158 4 месяца назад

      ​@@techfixPOV
      Do you have the mosfet part number for V11? Thx

    • @Sama_09
      @Sama_09 3 месяца назад

      @@techfixPOV hi man still excitedly waiting for that video :)

    • @techfixPOV
      @techfixPOV  3 месяца назад

      @Sama_09
      Have you seen this video? ruclips.net/video/co8H-HtbyVI/видео.html
      I uploaded it recently.