ProWarm Electric Underfloor Heating Sticky Mat V2 Installation
HTML-код
- Опубликовано: 28 май 2024
- #diy #energyefficiency #underfloorheating
Get a quote for your next underfloor heating project today!
📞 - 01268 567016
💻 - www.theunderfloorheatingstore.com
📧 - sales@theunderfloorheatingstore.com
-----------------------------------------------------------------------------------------------------------------------
00:00 - 01:08 - What’s in the box
01:10 - 03:15 - 1st Resistance Test and Installation form
03:16 - 04:38 - Priming Subfloor and Cutting Backer Boards
04:39 - 05:30 - Fixing boards with adhesive / screws & washers.
05:31 - 06:39 - Considerations regarding fixed units & sanitaryware
06:40 - 07:16 - Improvements & Benefits of V2 Mat.
07:17 - 08:04 - cable to thermostat backbox & Important info about Cold Tail Joint
08:05 - 08:33 - Floor probe positioning
08:34 - 10:40 - Installing Sticky Mat
10:41 - 13:09 - Floor probe and Conduit installation
13:10 - 13:45 - Pouring Levelling compound.
13:46 - 15:30 - Final mat / probe resistance checks and installation form
#underfloorheating #energyefficiency #diy - Хобби
I’ve just put 10mm of levelling compound down supplied by pro warm. How long do I leave to dry before I can turn heating on?
Hi
Could you please tell me what size notches trowel you are using just before laying the insulation boards at 5:00 timeline in this video. Thanks
6mm square notch design. We sell this on our website if you search 'square notch trowel' in search bar
At 5:36 I’m laying these board with tile flexible adhesive on new concrete screed floor so question is need put screws and washers to secure the insulated board also. ?
Thanks
@@Skills_02 You don't necessarily have to, but if screws are impossible to fit you can use a glue that we have on our site
You only need to fix down with flexible tile adhesive onto concrete. No mechanical fixings are needed.
Are you leaving the lcd thermostat that low down on the ground ?
Yes, out of shot there are several backboxes with supply and network cables at the normal height. The homeowner didn't want the thermostat up there as well as it would look / be very cluttered. Where the thermostat runs on floor temperature using the probe anyway it doesn't really matter where it goes, especially as the one selected can be controlled from an app.
The stat is ip21 so could go in zone 3 for example
@@andrewlee4938 Agree that it would technically be within regs but it wouldn't be practical. It's a knowledge and wisdom scenario. Just because a tomato is a fruit, it shouldn't go in a fruit salad. The face has a grille that allows air in, the humid, post-shower air will enter the thermostat which will shorten it's lifespan.