R32 Refrigerant charging-step by step procedure

Поделиться
HTML-код
  • Опубликовано: 5 сен 2024
  • All the refrigeration systems are designed to run without moisture and non-condensable gases else it may not work as designed and is likely to fail prematurely.
    The presence of moisture in the air conditioning system may lead to the formation of acidic sludge in the oil and may cause restrictions on various places like expansion valve and evaporator coils thereby reducing the overall cooling effect.
    In case of a hermetic compressor, it may cause deterioration of the insulation winding which may lead to a short circuit and compressor motor burn out.
    Non-condensable gases are just air which can enter during refrigerant charging, repair or maintenance. These gases take up space in the condenser and limit the amount of liquid refrigerant leading to reduced cooling efficiency.
    Evacuation is carried out by using a vacuum pump and a recovery bottle, ones the system evacuates we need to wait for about 20-25 min to check the pressure gauge is holding the negative pressure (vacuum) as shown in the image.
    This process may ensure that there are no leakages in the system as chances are air or moisture could enter via pipe cracks or leaky gasket or joints while performing evacuation procedures.
    In the above image, we can see there are two devices fitted one is an analog pressure gauge showing the final negative reading and another one is a digital vacuum gauge showing 500 microns as final reading, connected to the same line to ensure the system is 100% evacuated

Комментарии • 316

  • @rajkumar-en2lw
    @rajkumar-en2lw 3 года назад +15

    Super friend👍

  • @smartykhan471
    @smartykhan471 2 года назад +2

    Bhot hi achi tarh se smjhaya bahi aapne♥️♥️♥️

  • @msnawaz6509
    @msnawaz6509 3 года назад +7

    Bhai abhi sikhne ki Bahut zaroorat hai aap ko

  • @nigelhosein7822
    @nigelhosein7822 6 месяцев назад +1

    Hi would like to know whats the precharge pressure and what's the operating pressure on the suction line thanks

  • @devarrajchinna6510
    @devarrajchinna6510 9 месяцев назад +1

    Excellent work 👍

  • @kailash4069
    @kailash4069 3 года назад +12

    Sar gauge metre ke -30 per jaane se yah confirm Nahin hota hai ki Hamara system Puri Tarah Se vacuum ho chuka hai iske liye aapko proper II Micron gauge Ka istemal Karna chahie

    • @jahirtechnical
      @jahirtechnical 3 года назад +2

      Domestic machine mai 90% technician normal gage miter used kar ta hai,

  • @akkashraj999
    @akkashraj999 2 года назад +2

    Sir hamari New lg split ac hai, new Hai lekin jab Usko Installed kiya gya uske baad,jab pressure chhoda To usme gas Hi nhi thi,kya Problem Hai sir please bataiye,gas Hi Nhi thi ya koi lekeage hai outdoor unit me

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  2 года назад

      New ac me to aisa nhi hota hai usme gas hota hai

    • @akkashraj999
      @akkashraj999 2 года назад

      @@SMARTAIRCOOLSYSTEM to fir kaise

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  2 года назад

      Ho sakta hai uspe pahle se hi gas no ho Q ki kabhi kabhi aisa hota hau

    • @akkashraj999
      @akkashraj999 2 года назад +1

      @@SMARTAIRCOOLSYSTEM achha engineer ne bhi yahi bataya,but kahi Koi Leakage to nhi,unit me to koi damage nhi tha

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  2 года назад

      @@akkashraj999 nhi aisa nhi hoga

  • @hasmukhbutani1131
    @hasmukhbutani1131 3 года назад +1

    Super..bro..bahot..bahot..thanks

  • @mashooqueansari8439
    @mashooqueansari8439 3 года назад +1

    Ek number bhai 😎😎😎

  • @kunalelectricals8981
    @kunalelectricals8981 3 года назад +2

    Kunal electricals all ac motor ka kaam h mera koishi motor ho repair ho jaati h 👍

  • @inderjeetkumar2395
    @inderjeetkumar2395 2 года назад

    Very nice and thanks to knowledge and good luck

  • @sdas200
    @sdas200 3 года назад +2

    Sir a Bahar ja temperature is satha gas pressure ki ja sambondh?

  • @perumalv5807
    @perumalv5807 3 года назад +1

    Very good video

  • @AmanAman-fr1lm
    @AmanAman-fr1lm 3 года назад +1

    Bhai ek bat bataye ki chalte m gus dal sakte h R32 ki puri Band AC m Gus Dale bataye ga jarur fir m aapki video like and share karuga

  • @manishort3016
    @manishort3016 4 месяца назад

    Vaccum किया हुआ गैस कहां जाता है।
    क्या हम vaccum किए हुए गैस को sylender मे रख सकते हैं ताकि दुबारा वही गैस चार्ज कर सके?

  • @RajusRACSystem
    @RajusRACSystem 3 года назад +2

    Wonderful boro

  • @fahimuddin2997
    @fahimuddin2997 3 года назад +1

    Good work

  • @bhawaniveerwal6292
    @bhawaniveerwal6292 Год назад +1

    Bhaya agar bina miter ke gas charging kare to koi problem hota he kya pla batay

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  Год назад +1

      Bina meter ka gas charge Kro ge bhai to kaise pata chalega ki unit me jitna gas chahiye utna chala gya

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  Год назад

      Bina meter ka gas charge krna hai to gas ko weight kr ke charge Kro jitna unit me likha ho utna charge kr do

  • @CletoCelto
    @CletoCelto 3 года назад +2

    What about top up

  • @thahollywoodmovies4114
    @thahollywoodmovies4114 3 года назад +1

    Bhai achhi vedio h

  • @jaishankar6762
    @jaishankar6762 2 года назад +1

    Ac start karne k baad suction line par moisture kitne der me aa jana chahiye...pls...inform...
    Mere bluestar ac me 30 minute lag raha hi...or cooling bhi slow hi

  • @pilakitdavas3953
    @pilakitdavas3953 3 года назад +2

    Gas top up karne ke liye compressor ka weight kiya jai ya sirf back pressure psi hi ok hain

    • @jahirtechnical
      @jahirtechnical 3 года назад +1

      Normale india ka ambinet temperature kai sat r22 hoga to 32 ad hoga or r32/r410 hoga to 82 add kar kai back pressure rakh na chiay

    • @rohitmohanty641
      @rohitmohanty641 2 года назад +1

      @@jahirtechnical Mera lg ac ka r32 ka pressure 160 hai....Kya ye sahi hai ya kaam hai

    • @jahirtechnical
      @jahirtechnical 2 года назад

      @@rohitmohanty641 sahi nahi hai

    • @rohitmohanty641
      @rohitmohanty641 2 года назад +1

      @@jahirtechnical to kitna hona chahiye....jab ac chalu thi to outdoor me 160 tha gas ka pressure

    • @jahirtechnical
      @jahirtechnical 2 года назад

      @@rohitmohanty641 ayi say nahi batasakta,kiwkay r32 ka pressure chack karnay kay liya ambient temperature dekh na boho joruri hota ha,normali 110-120 Tak hota hay

  • @CletoCelto
    @CletoCelto 3 года назад +2

    What cfm is your vacuum pump and how you know what micron is your vacuum

    • @saruksarkar7908
      @saruksarkar7908 3 года назад

      i think domastic ac use normal vacom pump.commercial ac use micron gage .500micron vacom must

  • @puneetbhardwaj8494
    @puneetbhardwaj8494 2 года назад +1

    Bhai agar 150 pressure kr de to kuch problem hoti hai??

  • @mdsajjadansari4017
    @mdsajjadansari4017 3 года назад +2

    Nice sir

  • @roypjohno8118
    @roypjohno8118 3 года назад +1

    HAI GOOD MORNING SUPER job SUPER WORKING GOOD SUPER VOLTAS AC Gas chargeing👍👍👍👍👍👌👌🌹🌹🌹

  • @irshadsheikh2591
    @irshadsheikh2591 3 года назад +3

    Sir har compressor me alag alg gas q lagti or agr hum koi compressor me 134 ki jaga koi or gas dale to kya hota...

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад +2

      Es ke liye hm ek video bana ke dal denge

    • @shabbirahmed0529
      @shabbirahmed0529 3 года назад +3

      Apka blood group a positive ha apko b positive dedenge to kya hoga?

    • @thetechnician3748
      @thetechnician3748 3 года назад

      Oil some time should change .
      And capillary or orifice also different for various refrigerant

    • @samsolorider9942
      @samsolorider9942 3 года назад

      @@shabbirahmed0529 swal ke bdle swal wah kya bat h dub mro

  • @_UserX906
    @_UserX906 4 месяца назад

    Please help me, maine 2 din pehle ek 1.5 ton 5-star inverter AC khareeda. Installation team aayi aur indoor aur outdoor unit ko perfectly install kiya. Phir unhone system ko charging hose (service line) ke zariye vaccum kiya, aur vaccum complete hone ke baad vaccum motor ka valve band kiya aur motor ko off kiya. Uske baad unhone discharge line (liquid stop valve) ko 5 seconds ke liye khol ke leaks check kiya aur fir band kiya. Yeh sab kuch woh manual ke hisab se bilkul sahi kiya tha.
    Lekin manual ke according, unko charging hose se vaccum aur gauge ko service port se disconnect karna tha, phir liquid aur gas stop valves ko fully open karna tha. Lekin unhone discharge line ko puri tarah se khol diya aur phir charging hose ko disconnect karna shuru kiya, jis se gauge connected tha. Jaise hi gauge ke charging line (service line) se kholne lage, gas charging hose se leak hona shuru ho gayi aur unhone almost 30 seconds lagaye charging hose ko disconnect karne mein, tab tak woh leak kar rahi thi. Disconnect hone ke baad leak ruk gayi, aur phir unhone discharge line ko fully open kiya.
    Ab main overthinking kar raha hoon aur darr raha hoon ki woh gas kya thi, kya yeh refrigerant thi ya compressor oil ya phir air compressor mein se kuch ghus gaya hoga. Kyunki system ko vaccum kiya gaya tha, mujhe dar hai ki refrigerant contaminate ho gaya hoga aur compressor blast ho sakta hai. Ab main darr ke maare hoon ki kab blast ho jaye. Ab main kya karoon, please meri madad karo."

  • @AmitSharma-cu3jb
    @AmitSharma-cu3jb 3 года назад +1

    Bhai ji gas thodi jaldi dalte time comorassor heat ho jata hai kya .. Or 1 baat mene r22 dale thi window mai to cooling candancer neche se 6 pipe cool ho rhe hai but upper ke paip nhi ho rhe or return bhi ek dam cool ho rhi hai,,,, new capllery daale thi

  • @bobl78
    @bobl78 2 года назад

    that cylinder is crazy

  • @sonusony235
    @sonusony235 3 года назад +1

    good sir g 🙏🏻👍👍👍

  • @mohdnawazpasha1118
    @mohdnawazpasha1118 3 года назад +1

    Brother app ac running kar kay gas daal rahe hoo
    Balkay Ac may gas by wait dalna hai aur off karkay gas daalna hai app running may gas charge nahi karakahtay ...upper say ye inverter Ac hai ....

  • @MohdJaved-oq8bn
    @MohdJaved-oq8bn 3 года назад +1

    Nice bhai

  • @npangarkar7909
    @npangarkar7909 3 года назад +1

    Lg 1 ton R 410. machine ka condenser coil change kiya but ac ka cooling proper nahi ho raha hai or outdoor machine ka sound zyada ho gaya hai
    To kya problem hua hoga
    Plz reply

    • @jahirtechnical
      @jahirtechnical 3 года назад +1

      Coil size same hoga or property vacome ho ga to problem nahi hona chiay

  • @skK-xk3yc
    @skK-xk3yc 2 года назад +1

    sir technician ne 1.5 ton AC working R32 gas pressure 140 bataya .....kya ye tik hai ?

  • @bhabesh5867
    @bhabesh5867 3 года назад +1

    Kya AC k system me air hoke b compressor 1 hour tak chal sakta he.. Aur sahi se cool b karega 1 hour tak? Ya fir air rehne se system bilkul b cooling nai hoga? Please answer

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад +1

      Air rahne se chalega or cooling bhi karega pr jo cooling hona chahiye waisa nhi rahega or compressor ka life bhi km ho jayega

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад

      Or r32 gas me air hone se khatra bhi haj

    • @bhabesh5867
      @bhabesh5867 3 года назад

      @@SMARTAIRCOOLSYSTEM thank you for reply... Me pure gas nikal k firse vaccum karke new gas dalne k liye service request dia hu.. Dekhta hu kya hota he uske baad.. Mera inverter split ac he.. Carrier ka.. Installation k time Koi b pump nai laye the technician.. Aur wo log vaccum b nai kiye hein.. Bol rahe ki kuch flashing kiye the, self vaccum kiye the.. R32 gas he mera AC me.. 3 months ka he.. Installation k din se hi issue he

    • @kailash4069
      @kailash4069 3 года назад +1

      @@bhabesh5867 hamare AC ke system mein agar bhar ki a Raha jaati hai to compressor ki life per bahut asar padta hai uske oil ki density kharab ho jaati hai cooling per bhi fark padta hai jis technician ne aapka AC install Kiya hai usne self vacuum Kiya hai jabki self vacuum nahin karna chahie

    • @bhabesh5867
      @bhabesh5867 3 года назад

      @@kailash4069 me Unke against me Consumer Court me Case kar rhaa hu.. Wo log apna galti accept hi nai kar rahe.. Bol rahe. Bina vaccum kiye hue b AC chalta he.. Wo jaruri nai he.. 3mahine se suffer ho raha me.. Now i am pretty sure.. Unke vaccum na karne ki wajah se ye sb kuch hua he.. Thank you aapka bhi reply dene k liye sir 🙏😃🥰

  • @miteshpatel8705
    @miteshpatel8705 2 года назад +1

    1.5 Ac, R32 Gas , Running 140 psi bata rhe he to Gas ok hai ya Kam hai@?
    Plz reply me

  • @laddihanjra9421
    @laddihanjra9421 2 года назад +1

    tumne pehle leakage hi check nahi ki,agar khi leakage hui to machine vacuum kese hogi, is liye vacuum karne se pehle, pressure de ke leakage check kare,aur use band kare,
    Fir vecume karke gas charge kare

  • @veerpalsingh3988
    @veerpalsingh3988 2 года назад +1

    Good

  • @ankitdixit5994
    @ankitdixit5994 Год назад +1

    Pls my reply maine Naya ac liye pr company ke bande n vaccum ni kiya baad m maine complaint kare toh company reply sir hum aap ka copper or proper vaccum kr Denge with new gas

  • @fakharbhatti1550
    @fakharbhatti1550 2 года назад

    Plz ans
    Agar pipe leaking hu jay tu gas kharig huti hai yaa nhi ?

  • @ishadixit6831
    @ishadixit6831 3 года назад +1

    Bhai gash shai charg kare h or papi bhi child ho rhai h lakne indore ka Fan kame jyade ho rha h or cooling bhi nhi ho rhai h kya kare

  • @SanjaySharmapharmacypoint
    @SanjaySharmapharmacypoint Год назад

    R32 Back pressure 150 hai mere Daikin 1.5 tan non inverter ac me
    Kya karu nikal du gas thoda

  • @anandanandraj5309
    @anandanandraj5309 10 месяцев назад +1

    Sir R410a gas charges mathed same ah?

  • @vivekaryan5742
    @vivekaryan5742 Год назад

    Bhai mere new ac ki gas puri nikal ker vacuum kiya hai abhi new ac hai cooling ki problem thi lekin ab jyaa hi hai

  • @aakashaaswani4020
    @aakashaaswani4020 3 года назад +1

    Yr mene ac lagwaya voltas ka isme na jab outdoor start hota h na to nichy indoo me souund aata gas ka sound aata h 3 se 4 second jab jab ac start hota h y sound aata h ac walla bol ra r 32 me awaz aati h but tez aawaz aati h

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад

      Vacuum nhi kiya hoga

    • @aakashaaswani4020
      @aakashaaswani4020 3 года назад +1

      @@SMARTAIRCOOLSYSTEM thank you for replying sir wo 4 se 5 br aa gya pr bol ra h vaccume kiya h ac dhang se fit kiya h sab shi kiya h pr fr be jese hi ac ko start krty h or outdoor start hota h ek gas ki sound aati h 3 se 4 seconds k liye jese kisi truck mese hwa nikl ri ho
      Pr ac wala technician bol ra h ki compressor se y gas ac me seculte hori h pr sound kyo aara h aj tak mene kisi ac me ni suna ye sound or outdoor ki aawaz be nichy aati h btao sir me kya kru

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад

      Abhi mai ek video upload kiya hu wo dekh liye sab samajh me aa jayega

  • @ranjanreddy6816
    @ranjanreddy6816 2 года назад

    1:42 vacuum laganahe or neekalne hai -30 means compressor se air leekaldiya lagadiya ?

  • @shehzadiinaya2073
    @shehzadiinaya2073 3 года назад +2

    Sar in geso ko wazan karke dalna chahiye bak preshar se nahi

  • @DanishAli-mf4ly
    @DanishAli-mf4ly 3 года назад +1

    Sir mere pass DC inverter gree ka ac he wo thiri der chalta he to band ho jata he or phir khud hi chal b jata he

    • @mr.deepsense2457
      @mr.deepsense2457 2 года назад +1

      Timer lga hua hai

    • @DanishAli-mf4ly
      @DanishAli-mf4ly 2 года назад

      @@mr.deepsense2457 sir 11 month pehle ka falt or ab reply 😂😂😂 thanks but wo hal ho geya tha jazakAllak

    • @DanishAli-mf4ly
      @DanishAli-mf4ly 2 года назад

      Uska main bord me falt tha

  • @justentertainment918
    @justentertainment918 3 года назад +2

    New AC ma to vacuum zaruri nhe na usma to phly sy gas hti h

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад

      Bhai indoor me jo air rahta hai usko kaise nikalo ge

    • @justentertainment918
      @justentertainment918 3 года назад +1

      @@SMARTAIRCOOLSYSTEM Sir ma to apsy phuch rha mjy nhe pta mny new ac purchase krna h kal usma r32 gas h esliye apsy phucha k kya usy b vacuume krna hoga

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад

      Han krna hoga

    • @ashwiensewpersad2927
      @ashwiensewpersad2927 2 года назад

      Piping has air bro

  • @ektaruddin7702
    @ektaruddin7702 3 года назад +1

    NICE

  • @sohelmandal7955
    @sohelmandal7955 Год назад +1

    Vacuum karney k time outdoor chalurackey

  • @aasifshah7383
    @aasifshah7383 2 года назад +1

    VOLTAS KE AC ME INVERTER AC ME COMPRESSOR AND PCB PE WARRENTY KIT NI MIL TI HE

  • @MuhammadImran-iv9ze
    @MuhammadImran-iv9ze 2 года назад

    Ap apna selender tu change Kary buhat porana lag raha hai ye hi blast kardy ga

  • @ottomanheros
    @ottomanheros 3 года назад +1

    Nice

  • @shamshadtechlife2435
    @shamshadtechlife2435 3 года назад +1

    R32 inverter ac hai 15 20 chalne ke baad outdoor pura band ho jata hai aur phir 3 4 minut baad phirr se start ho jata hai kya dikkat ho sakti hai

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад

      Kuch Error ata h kiya

    • @nikhilgajra1377
      @nikhilgajra1377 3 года назад +1

      Mera same issue tha, pipeline me leakage tha mera

    • @jahirtechnical
      @jahirtechnical 3 года назад

      Error code nahi dikha ta hai to, indoor sensor problem hosakta hay,or outdoor DLT sensors ka problem vi ho sakta hai back pressure chack karkay daykho

  • @as1asim
    @as1asim 2 года назад

    Sir maine naya Hitachi 1.5ton non inverter ac liya hai usnme piping karte time thoda leakage huva tha usme kitna pressure rehna chaiye bata sakte hai aap?cooling me time le raha hai bohot sayed gas ki wajah se ho sakta hai.leakage abi kuch nahi hai but proper cooling nahi mil raha.

    • @islam_971
      @islam_971 2 года назад +1

      Gas konsi h usme bro

    • @as1asim
      @as1asim 2 года назад

      @@islam_971 R32

  • @payyon393
    @payyon393 3 года назад +3

    Hi, does LG also provide Vacuum for R32 ac as I have seen many LG installation video and none of them have done it.. Is it okay if its not done vacuuming. I have ordered LG too, but dont know now if they will do it for my ac too.

    • @insvaibhav
      @insvaibhav Год назад

      Ask them to do, its standard peocess.

  • @buntytiger5489
    @buntytiger5489 Год назад +1

    bhai maine new ac purchase Kiya 1.5 ton ka mera room size only 120 square feet hai technician ne kuch gadbad kar di hai room Thanda hi nahin hota hai continue 16 degree per ek ghanta chalane per bhi complaint Kiya hai technician aa ke chala gaya lekin bolata hai koi problem nahi hai ab mujhe batao Bhai mai video banana chahta hu kya kya check karna padega mujhe ek bar technician visit aur hone wali hai r 32 gas hai mere ac mein technician gas dalna hi nahi chahta hai Shayad

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  Год назад

      Ac Ka Grill temperature napaye kitna hai room temp se km se km 10*c km hona chahiye grill ka

  • @anwarali1971
    @anwarali1971 2 года назад +1

    i like thi

  • @npangarkar7909
    @npangarkar7909 3 года назад +1

    Perfect.
    Aksar technician bina vacume kiye bager gas charge kar dete hai.
    My experience

  • @rjmani8194
    @rjmani8194 3 года назад +1

    brother suction discharge pressure r32?

  • @mritunjaykumarsingh1560
    @mritunjaykumarsingh1560 2 года назад +1

    Sir R32 gas ka pressure kitna hona chaiye? 130 psi ya 150 psi?

  • @AmitSharma-cu3jb
    @AmitSharma-cu3jb 3 года назад +1

    Bhai ji mere ghr pr 1,5 ton ka window ac hai bristol comorasher hai kya hota hai room ko cool।krne mai।time।लेता ha service bhi करवा chukaa hu khi आइस bhi nhi aa rhi ,,,,,ac ka girl tampracher 15 16 digre aa rha hai kya proble ho sktee ha

    • @AmitSharma-cu3jb
      @AmitSharma-cu3jb 3 года назад

      Pls kuch btaiye kya problem ho sktee hai

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад +1

      15 16 km hai 10 12 hona chahiye

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад

      Isliye tym le rha hai

    • @AmitSharma-cu3jb
      @AmitSharma-cu3jb 3 года назад +1

      @@SMARTAIRCOOLSYSTEM bhai ji ऐसा to nhi bristol comprasher jo lga hua hai us amp 7,9 hai abhi 6.8,,7 ले रहा hai khi gas km ho ,,nhi to ap apne tajurbe se मदद kre

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  3 года назад

      Bhai amp ya to 6 ya 7 ya uske bich me hona chahiye ya 7 ya 8 ke bhich me 6 7 8 is tarah nhi hona chahiye

  • @ProphetIncident
    @ProphetIncident 3 года назад +1

    Bhai gauge to r32 waala use kr lete fridge waala guage se hi daal rahe ho

  • @hiteshsurve971
    @hiteshsurve971 2 года назад +1

    Kitne time baad ges charge karna padta he

  • @albakshkhan131
    @albakshkhan131 2 года назад

    Bhai o ganral ki gas charjing kaise kre ho ye bhi bta do bhai

  • @goutamsutradhar9642
    @goutamsutradhar9642 5 месяцев назад

    R32 kya duplicate gas bhi hota hai

  • @dharmarajdhungana6575
    @dharmarajdhungana6575 3 года назад

    Sir mera out door 2.3 minut chalta or banda hota hai fan and compressor puraa band hota hai kya problem hai ji plz answer me🙏

  • @subhadipchakraborty901
    @subhadipchakraborty901 3 года назад +1

    Mera carrier 1.5 ton ac me har sal me gas varna hai motlob har sal me gas leakge hota hai. Sir ye kaise ho sakta?

  • @sonu-hk3rq
    @sonu-hk3rq 2 года назад

    Gas charging k time kea machine running rakhana sehi hai?

  • @farahsaikh6259
    @farahsaikh6259 3 года назад +1

    Hi

  • @justride1998
    @justride1998 3 месяца назад

    Gas refill price

  • @FaizKhan-bh4ux
    @FaizKhan-bh4ux 3 года назад +1

    Tq

  • @adityakmr75
    @adityakmr75 3 года назад +1

    1.5 Ton Voltas AC me कैपिसिटर कीतने का और किस कम्पनी का लगता हैं। वरल फुल का कैपिसिटर लगा के कोई भी पैसे ले लेता हैं। प्राइस कितना होता हैं ये भी बताये

  • @abdulrashid6585
    @abdulrashid6585 3 года назад +1

    Mast

  • @RehanElqadri
    @RehanElqadri 3 года назад +1

    Vacuum Kese kare?
    AC On krke! Ya off karke?

  • @aqkhana2002
    @aqkhana2002 Год назад

    how much gas should be ??? no one has asked important question :)

  • @katowalsuraj
    @katowalsuraj 3 года назад +1

    Woh toh theek hai but 1 kilo meat kitne ka bech rahe hain abbu?

  • @rocker2704
    @rocker2704 Год назад

    From where I can buy r32 gas?

  • @surajsinghaniamunger6590
    @surajsinghaniamunger6590 3 года назад

    Sir voltas kaise company kaam Karna hai

  • @davepenprase
    @davepenprase 3 года назад

    never heard of r-32 and wtf r u'all saying? nevermind but can u help me with atleast a p/t chart?

  • @DanishAli-mf4ly
    @DanishAli-mf4ly 3 года назад +1

    Licude sensre ka to maska ni he

  • @kulveersinghdhiman8633
    @kulveersinghdhiman8633 3 года назад +1

    sir kya sbe ac mein r32 he dalte hai

  • @shubhambugade4654
    @shubhambugade4654 2 года назад +1

    Mujhe zero pressure bataya ac mai aur top up krne bola toh mana kr diya. Bole aisa nahi hota, machine ko khol ke check krna padega..9000 kharcha bataya..kya kru friend?

    • @SMARTAIRCOOLSYSTEM
      @SMARTAIRCOOLSYSTEM  2 года назад +1

      Boliye pahle presser hold kare system me alag alag indoor or outdoor me jiska presser km hoga usko khol ka check karega

  • @saleem5834
    @saleem5834 3 года назад +3

    👍👍👍👍👍

  • @pramodmore918
    @pramodmore918 3 года назад +2

    Bhai mere R32 ac ka suction pressure 140 psi hai phir bhi grill temperature 14℃ ke niche nahi jyata. kya karna hoga?

    • @pramodmore918
      @pramodmore918 3 года назад

      ??????

    • @SDDEVIL_
      @SDDEVIL_ 3 года назад

      @@pramodmore918 mere ac ka 150 hein 120 se laikr 150 takk sahi hein new laggwaeya hein abhi uska company se 150 aeya hein

    • @pramodmore918
      @pramodmore918 3 года назад

      @@SDDEVIL_ pipe length kitna hai?

    • @sktechnicalsupport47
      @sktechnicalsupport47 2 года назад

      Service

  • @gensunservices251
    @gensunservices251 2 года назад +1

    sir Back pressur kitna rakhna hai

  • @thahollywoodmovies4114
    @thahollywoodmovies4114 3 года назад +1

    Lg dual inverter ac me cooling km kr rha h gass bhi thik h service bhi ok h it Flo km h or cooling km kr rha h

  • @sanjayseth8093
    @sanjayseth8093 3 года назад +1

    सर जी क्या r32 गैस चार्जिंग करते समय कंप्रेसर ब्लास्ट होने का खतरा होता है क्या?? बहुत से मिस्त्री ऐसा कहते हैं कृपया आप बताए
    Sar ji isiliye abhi tak humne r32 और 410 की गैस चार्जिंग नहीं किए प्लीज sar reply jarur Karen

  • @SauravBera-mr5qw
    @SauravBera-mr5qw Год назад

    Bhai kaise pata chalega R32 dala ya R22 ya 410

    • @insvaibhav
      @insvaibhav Год назад

      Ac pe bada bada likha hoga

  • @sktechnicalsupport47
    @sktechnicalsupport47 2 года назад

    R32 main ek baar main gas charging karne hote running ac main gas charging karahe hai

  • @melophile04
    @melophile04 2 года назад

    How much time it will take to vaccuum fully upto -30 ?

  • @npangarkar7909
    @npangarkar7909 3 года назад +1

    Lg 1.5 tr. non inverter me psi Kitna hona chahiye

  • @sharsh55
    @sharsh55 3 года назад +3

    Never purchase Lloyd Ac because i am genuinely telling you it is totally waste of your hard earned money.If u dont believe,u may purchase and waste your money, Useless product of Havells India,

  • @MariMuthu-mx2lk
    @MariMuthu-mx2lk 3 года назад

    Super bro

  • @mukeshkumar-ix3rp
    @mukeshkumar-ix3rp 2 года назад

    Aap kahan rahte ho sir

  • @RavinderSingh-cd6dx
    @RavinderSingh-cd6dx 3 года назад +2

    👍👍

  • @vision-qu8gx
    @vision-qu8gx 3 года назад +1

    Goood

  • @domnicdasilva8519
    @domnicdasilva8519 2 года назад

    What cfm is your vacuum pump what micron is your vacuum

    • @zeeshawn15
      @zeeshawn15 2 года назад

      U know he has no clue.