Sahi kaha bhai inhone video me galat bataya hai Phase wire ko running per denge Running or Common k beeche sbse tez bulb jalega usii per PHASE denge...
Good explanation given by u sir. One small correction is to be made i.e. while connecting the capacitor with start a d run, u hv informed that starting coil wire connected to capacitor to be inserted in phase line of the connector. But only the running coil wire with capacitor connection should be connected to phase terminal and common wire in neutral. Please don't give starting coil wire with capacitor connection in phase line terminal of connector. It should be connected in the dummy whole of the connector. Because starting coil is only for starting the fan and after that running winfibv takes care. Just for correction please. In short capacitor wire with running coil wire in phase, common wire in neutral and starting coil wire with capacitor connection in the dummy hole of the connector. This is the correct method. Otherwise, fan coil will get heated and may give trouble in few days. after
If the motor is Permanent Capacitor run motor than we give Power supply to running wire or starting wire, in both condition the two wire will get phase supply always So In ceiling fan & table fan we can give power supply to any of the wire But if you are using capacitor start motor ( means if there is centrifugal switch in motor ) than you have to give power supply to running wire only
🇮🇳✊🧐🤔..mere khyaal me pehele walaa direction hee sahi thaa(clock wise) agar fan ko nichese dekhte hain toh vo anti clockwise ghumtaa Nazar aayegaa,agar main galat hu toh sahee kar dena.dhanyawaad.
sir ,a bit of confusion, usually the running coil has more winding then the starting coil ,therefore its resistance will be also high, please correct me if i am wrong .
Nice bhi jan Mera ap sy aik question hai k humein kaise pta chly ga 12+12 coils me itni turns a jye gyi aur 14+14 coils me itni turns a jyen gyi aur zyda coils kis me Ani Hain 12+12 wali coils me ya phr 14+14 wali coils me meherbani yeh to Mera issue solve kr dein
The starting winding is wound with fewer turns of thin wire than the running winding, so it has higher resistance. The running winding is wound with large turns of thick wire than the starting winding, so it has lower resistance.
Bakbaas karta hai.ek hi baat ko bar bar bol raha hai.simple method to identify running winding,starting winding and common wire are colour code by red,black/blue and yelow..
If the motor is Permanent Capacitor run motor than we give Power supply to running wire or starting wire, in both condition the two wire will get phase supply always So In ceiling fan & table fan we can give power supply to any of the wire But if you are using capacitor start motor ( means if there is centrifugal switch in motor ) than you have to give power supply to running wire only
Phase wire should be connected on running otherwise fan will run Opposite side .don, t give wrong information it will give a heavy loss to the new commers.
Mostly indian RUclipsr Ceiling fan connection telling wrong. |^^^^^^^^^^^~~~~|~~~~0 N ____| R = | S | |^^^^^^^'~~~~~~~|~~~0 Line Because Running wire size Less than Staring wire. example Running 30 Starting 32 SWG so resistance 👇 Resistance should be Com to Starting 240 Ω Com to Running 190 Ω Starting to Running 430 Ω Why they connect line on neutral with starting winding (high resistance end) 👉But if you watch Pakistani or other RUclipsr video. they connect line on neutral with Running winding ( Low Resistance end)
5:00 starting winding ka resistance jyaada nahin kam hota hai running winding se. aap ulta bol rahe ho !!! starting winding is shorter than running winding length so stating winding cant have higher resistance than running winding.
I am totally confused with ceiling fan,which core pole is of starting winding and which is of running winding?.i hope outer core is of running winding and inner core pole is of starting winding.is it correct?.when iam measuring the resistance of ceiling fan Resistance of running winding > Resistance of startingwinding
I have a fan . In which resistance between Red -- blue. 275. Red -- yellow 277 and yellow-- blue. 554 now. Comn is Red and running wire ( phase) is blue or yellow. Pls tell me.
The starting winding is wound with fewer turns of thin wire than the running winding, so it has higher resistance. The running winding is wound with large turns of thick wire than the starting winding, so it has lower resistance.
Jiyo boss super video banaya hai aapne
Right information good video
Excellent explanation..... I don't know hindi....but I can understand your explanation.....god bless you..
Phase should be given to runnin wire for clockwise direction. If u give phase to starting wire fan will rotate in anticlock direction.
Sahi kaha bhai inhone video me galat bataya hai Phase wire ko running per denge
Running or Common k beeche sbse tez bulb jalega usii per PHASE denge...
Very clear explanation.. 👍
Right@@SameerKhan-tc5yv
i watch is video from India Nani mumbai it quit clear sir 🙏
Bahut achi video hai aap bahut bahut thanks ❤
Running winding turns r more, how u will get more resistance in starting winding. Can you explain me
Same question
Good 👍 excellent 👏 👌 👍
You have explained well.
Very nice explanation thanks
👌👌👍👍🔥🔥very nice... 🙏..explation sir ji
Thank you very much. Very useful video 🎉
Thanks for the explanation
चंदू गायकवाड
Excellent information
No any dobut .
Great explain bro keep going
hi sir it correct it understood after one yr the the capacitor is use 2.5 it ok sir it great and clear
Very good explain thanku
Nice information sir thx very much
Phase or neutral should be connected on running winding otherwise the fan will move in opposite direction or clockwise
Very nice sir
Very good and simple information thanks
You are welcome
Thanks..... Bro❤
Nice video sir
Thanku Sirgi 🙏🙏🙏
I am Rahman Ali from Pakistan
Thanks for being the family member of Electrical Technician 🙏
Very nice explain
So nice thanks sir
Amazing video
You are excellent
Very nice explanation 👌
Good explanation given by u sir. One small correction is to be made i.e. while connecting the capacitor with start a d run, u hv informed that starting coil wire connected to capacitor to be inserted in phase line of the connector. But only the running coil wire with capacitor connection should be connected to phase terminal and common wire in neutral. Please don't give starting coil wire with capacitor connection in phase line terminal of connector. It should be connected in the dummy whole of the connector. Because starting coil is only for starting the fan and after that running winfibv takes care. Just for correction please. In short capacitor wire with running coil wire in phase, common wire in neutral and starting coil wire with capacitor connection in the dummy hole of the connector. This is the correct method. Otherwise, fan coil will get heated and may give trouble in few days. after
If the motor is Permanent Capacitor run motor than we give Power supply to running wire or starting wire, in both condition the two wire will get phase supply always
So In ceiling fan & table fan we can give power supply to any of the wire
But if you are using capacitor start motor ( means if there is centrifugal switch in motor ) than you have to give power supply to running wire only
Super sir.
nice explanation
Excellent explanation and guidance. Very clear identification of common,starting and running wires.
Very very nice
Fist comment
🇮🇳✊🧐🤔..mere khyaal me pehele walaa direction hee sahi thaa(clock wise) agar fan ko nichese dekhte hain toh vo anti clockwise ghumtaa Nazar aayegaa,agar main galat hu toh sahee kar dena.dhanyawaad.
Nice sir nice
Nice video
Thank you sir for your type of good,easy understandable explained system ,like the instructor !
sir ,a bit of confusion, usually the running coil has more winding then the starting coil ,therefore its resistance will be also high, please correct me if i am wrong .
You are correct.
Yes bro u r 100% right
You are right
Video me गलत जानकारी दे rahe हे 😢
Nice bhi jan
Mera ap sy aik question hai k humein kaise pta chly ga 12+12 coils me itni turns a jye gyi aur 14+14 coils me itni turns a jyen gyi aur zyda coils kis me Ani Hain 12+12 wali coils me ya phr 14+14 wali coils me meherbani yeh to Mera issue solve kr dein
Thanks so much
Thank you sir ji
Supply running pe di jati he sir
2.5 MFD CAPACITOR THANKS SIR
Thank you sir 2.5 ka capacitor Lage ga
Thakns sir
Great explanation
Short circuit men to resistance bhar jati he? Ya kam hojati he?
Good
Good.idia
Sir I think running winding should have more resistant n phase wire is connected to running winding
The starting winding is wound with fewer turns of thin wire than the running winding, so it has higher resistance. The running winding is wound with large turns of thick wire than the starting winding, so it has lower resistance.
@@ElectricalTechnician you are Right
Nice
❤
The capacitor value is 2mfd to 2.5mfd 250 volts AC.
Yes
Yes #anilautomationhindi
Starting winding resistance is less than running winding because starting winding have thick and less turn as compared to running winding
Right
starting winding have high resistance because we have to create some phase difference to produce rmf
Not thick it has thin so it has high resistance
@@Kishan_kinniBut someone says Running coil resistance is high 🐸
Bakbaas karta hai.ek hi baat ko bar bar bol raha hai.simple method to identify running winding,starting winding and common wire are colour code by red,black/blue and yelow..
Bro please make videos on home alarm system on boush brand 2000 and 3000
Sir lift panel ki wiring kese hota hai ise ke uper vdo banaiye
Many thanks..please download pdf diagram?
Are bhai jab fan ko phase starting winding par denge to fan ka moter kharab nhi hoga kya
If the motor is Permanent Capacitor run motor than we give Power supply to running wire or starting wire, in both condition the two wire will get phase supply always
So In ceiling fan & table fan we can give power supply to any of the wire
But if you are using capacitor start motor ( means if there is centrifugal switch in motor ) than you have to give power supply to running wire only
Phase wire should be connected on running otherwise fan will run
Opposite side .don, t give wrong information it will give a heavy loss to the new commers.
You are right sir
Mai bhi yahi soch raha tha
Mostly indian RUclipsr
Ceiling fan connection telling wrong.
|^^^^^^^^^^^~~~~|~~~~0
N ____| R =
| S |
|^^^^^^^'~~~~~~~|~~~0 Line
Because
Running wire size Less than Staring wire.
example
Running 30
Starting 32 SWG
so resistance 👇
Resistance should be
Com to Starting 240 Ω
Com to Running 190 Ω
Starting to Running 430 Ω
Why they connect line on neutral with starting winding (high resistance end)
👉But if you watch Pakistani or other RUclipsr video.
they connect line on neutral with Running winding ( Low Resistance end)
My question also 😢
Right
Bhai jis ki resistance ziyada ho wo running ho ga ya stating ye nhi bataya
Right
5:00 starting winding ka resistance jyaada nahin kam hota hai running winding se. aap ulta bol rahe ho !!! starting winding is shorter than running winding length so stating winding cant have higher resistance than running winding.
Celling fan me running winding ka resistance jyada hota hai or starting winding ka resistance kam hota hai
Am i right???
Yes
Main supply hamesha Running winding pe honi chahiy
Bilkul sahi kaha aapne ye wrong bata raha hai
🙏❤️👌👍🖐️
I am totally confused with ceiling fan,which core pole is of starting winding and which is of running winding?.i hope outer core is of running winding and inner core pole is of starting winding.is it correct?.when iam measuring the resistance of ceiling fan Resistance of running winding > Resistance of startingwinding
I have a fan . In which resistance between Red -- blue. 275. Red -- yellow 277 and yellow-- blue. 554 now. Comn is Red and running wire ( phase) is blue or yellow. Pls tell me.
Fan capactar 2:5 Afd
Capacitor value 1000 πF .
Which winding has more resistance? and Why?
Withou multimeter and seris testing lamp kese find kre konsa conection krna he
2.5 MFD से 3 MFD तक लगा सकते हैं
Inner winding is starting n outer winding is running winding so running winding got high resistance then starting winding
The starting winding is wound with fewer turns of thin wire than the running winding, so it has higher resistance. The running winding is wound with large turns of thick wire than the starting winding, so it has lower resistance.
BHAI TUM LOG KAYA BATAY HAI KOI BOLTA HAI RUNING KI RESISTANCE JAYDA HOTI STARTING KI KAM KOI ULTA BOLTA HAI AISA KIYO?
मे भी वोही confuse होरहा हु 😢😢😢
Sir har fan ka capacitor ka value kese measure Karin?
2.5 sir
I m getting 211 ohms, 199 ohms and 14 ohms in ceiling fan connection. What to do?
Me pahli baar fan ki winding ko ander se dekh raha hu
2.5 microfarad
Yek me glow ni kr rha h kya problem hai
40pf capacitor to be used.
Capacitor generally 2.25 microfarad use hota hai ceiling fan mein
2.5 micro faired
2.25 cap
Winding ok he capacitor ok he phirbhi speed kam kai se hota he
Capacitor ka dum nikl gya hoga change kro
पेपर पर डायग्राम सीखाए
2.5 - 2.25 Mfd
3.15uf
Point ke bad value zero hai to multy meter ko sudharen pehele
2.5 and 3.15 the sall
2.25 to 2.50 MFD
2.5 micro farad
Capisiter 2.5 ka lagega .
Yes
You also add your body resistance to wire resistance
seen
2.5 capaciter
Ni no