Ceiling fan Proper connection with capacitor in Hindi

Поделиться
HTML-код
  • Опубликовано: 5 янв 2025

Комментарии • 194

  • @mohammadsohrab6064
    @mohammadsohrab6064 2 года назад +4

    Jiyo boss super video banaya hai aapne

  • @BilalAwan-qs7jo
    @BilalAwan-qs7jo 3 месяца назад +1

    Right information good video

  • @charlesnijanthan3686
    @charlesnijanthan3686 2 года назад +3

    Excellent explanation..... I don't know hindi....but I can understand your explanation.....god bless you..

  • @shafiahmed2880
    @shafiahmed2880 2 года назад +11

    Phase should be given to runnin wire for clockwise direction. If u give phase to starting wire fan will rotate in anticlock direction.

    • @SameerKhan-tc5yv
      @SameerKhan-tc5yv 2 года назад +2

      Sahi kaha bhai inhone video me galat bataya hai Phase wire ko running per denge
      Running or Common k beeche sbse tez bulb jalega usii per PHASE denge...

    • @antonyandrews2902
      @antonyandrews2902 Год назад

      Very clear explanation.. 👍

    • @11_akashkamble8
      @11_akashkamble8 9 месяцев назад

      Right​@@SameerKhan-tc5yv

  • @ConfusedAbyssinianCat-ke4bt
    @ConfusedAbyssinianCat-ke4bt 4 месяца назад

    i watch is video from India Nani mumbai it quit clear sir 🙏

  • @ShaikMahboobbavazeer
    @ShaikMahboobbavazeer Год назад

    Bahut achi video hai aap bahut bahut thanks ❤

  • @slntech3082
    @slntech3082 Год назад +6

    Running winding turns r more, how u will get more resistance in starting winding. Can you explain me

  • @mianhaseeb7873
    @mianhaseeb7873 2 года назад

    Good 👍 excellent 👏 👌 👍

  • @newbharatblog3567
    @newbharatblog3567 10 месяцев назад

    You have explained well.

  • @prakashdiemaker2272
    @prakashdiemaker2272 2 года назад +1

    Very nice explanation thanks

  • @jiteshpurena
    @jiteshpurena 2 года назад

    👌👌👍👍🔥🔥very nice... 🙏..explation sir ji

  • @syedyawarabbaszaidi4599
    @syedyawarabbaszaidi4599 Год назад

    Thank you very much. Very useful video 🎉

  • @sebidsouza4029
    @sebidsouza4029 2 года назад +3

    Thanks for the explanation

  • @sureshshinde2364
    @sureshshinde2364 6 месяцев назад

    Excellent information
    No any dobut .

  • @TengrakMSangma
    @TengrakMSangma 2 года назад

    Great explain bro keep going

  • @ConfusedAbyssinianCat-ke4bt
    @ConfusedAbyssinianCat-ke4bt 4 месяца назад

    hi sir it correct it understood after one yr the the capacitor is use 2.5 it ok sir it great and clear

  • @rajannarayanan2759
    @rajannarayanan2759 2 года назад

    Very good explain thanku

  • @PawanSharma-tt7ho
    @PawanSharma-tt7ho 2 года назад

    Nice information sir thx very much

  • @ankr7.0
    @ankr7.0 2 года назад +11

    Phase or neutral should be connected on running winding otherwise the fan will move in opposite direction or clockwise

  • @vidyashastri4812
    @vidyashastri4812 2 года назад +2

    Very nice sir

  • @NaseerAhmad-lo3ke
    @NaseerAhmad-lo3ke 2 года назад

    Very good and simple information thanks

  • @RajuRaju-wy7ek
    @RajuRaju-wy7ek Год назад

    Thanks..... Bro❤

  • @krishnasoti894
    @krishnasoti894 Год назад

    Nice video sir

  • @yaswanthdevannaamin6234
    @yaswanthdevannaamin6234 2 года назад

    Thanku Sirgi 🙏🙏🙏

  • @rahmanali3235
    @rahmanali3235 2 года назад +1

    I am Rahman Ali from Pakistan

    • @ElectricalTechnician
      @ElectricalTechnician  2 года назад +1

      Thanks for being the family member of Electrical Technician 🙏

  • @jaykumardore1278
    @jaykumardore1278 2 года назад

    Very nice explain

  • @kabandajamir9844
    @kabandajamir9844 Год назад

    So nice thanks sir

  • @kewalsingh9934
    @kewalsingh9934 2 года назад +1

    Amazing video

  • @sureshshinde2364
    @sureshshinde2364 6 месяцев назад

    You are excellent

  • @Hassang185
    @Hassang185 2 года назад

    Very nice explanation 👌

  • @proudindian8041
    @proudindian8041 2 года назад +4

    Good explanation given by u sir. One small correction is to be made i.e. while connecting the capacitor with start a d run, u hv informed that starting coil wire connected to capacitor to be inserted in phase line of the connector. But only the running coil wire with capacitor connection should be connected to phase terminal and common wire in neutral. Please don't give starting coil wire with capacitor connection in phase line terminal of connector. It should be connected in the dummy whole of the connector. Because starting coil is only for starting the fan and after that running winfibv takes care. Just for correction please. In short capacitor wire with running coil wire in phase, common wire in neutral and starting coil wire with capacitor connection in the dummy hole of the connector. This is the correct method. Otherwise, fan coil will get heated and may give trouble in few days. after

    • @ElectricalTechnician
      @ElectricalTechnician  2 года назад +1

      If the motor is Permanent Capacitor run motor than we give Power supply to running wire or starting wire, in both condition the two wire will get phase supply always
      So In ceiling fan & table fan we can give power supply to any of the wire
      But if you are using capacitor start motor ( means if there is centrifugal switch in motor ) than you have to give power supply to running wire only

  • @devnarayanchaudhary9948
    @devnarayanchaudhary9948 2 года назад

    Super sir.

  • @james-bond-007
    @james-bond-007 9 месяцев назад

    nice explanation

  • @rajshah7918
    @rajshah7918 2 года назад +1

    Excellent explanation and guidance. Very clear identification of common,starting and running wires.

  • @kushrajbongshi4210
    @kushrajbongshi4210 2 года назад

    Very very nice

  • @rahmanali3235
    @rahmanali3235 2 года назад +1

    Fist comment

  • @marutinayak958
    @marutinayak958 Год назад

    🇮🇳✊🧐🤔..mere khyaal me pehele walaa direction hee sahi thaa(clock wise) agar fan ko nichese dekhte hain toh vo anti clockwise ghumtaa Nazar aayegaa,agar main galat hu toh sahee kar dena.dhanyawaad.

  • @seemabehera7045
    @seemabehera7045 Год назад

    Nice sir nice

  • @abdurrahim-xr1ue
    @abdurrahim-xr1ue 2 года назад

    Nice video

  • @satyanarayanam5930
    @satyanarayanam5930 2 года назад +1

    Thank you sir for your type of good,easy understandable explained system ,like the instructor !

  • @haridas992
    @haridas992 2 года назад +12

    sir ,a bit of confusion, usually the running coil has more winding then the starting coil ,therefore its resistance will be also high, please correct me if i am wrong .

  • @deepphysics876
    @deepphysics876 2 года назад

    Nice bhi jan
    Mera ap sy aik question hai k humein kaise pta chly ga 12+12 coils me itni turns a jye gyi aur 14+14 coils me itni turns a jyen gyi aur zyda coils kis me Ani Hain 12+12 wali coils me ya phr 14+14 wali coils me meherbani yeh to Mera issue solve kr dein

  • @AjayPatel-lt7bq
    @AjayPatel-lt7bq 2 года назад

    Thanks so much

  • @yashpal5533
    @yashpal5533 2 года назад

    Thank you sir ji

  • @IshwarSingh-di2yu
    @IshwarSingh-di2yu 2 года назад +2

    Supply running pe di jati he sir

  • @tariqueanwar3665
    @tariqueanwar3665 2 года назад +1

    2.5 MFD CAPACITOR THANKS SIR

  • @ansariisrafil4162
    @ansariisrafil4162 2 года назад +1

    Thank you sir 2.5 ka capacitor Lage ga

  • @mahbubrobal5480
    @mahbubrobal5480 9 месяцев назад

    Thakns sir

  • @thedecorvases5643
    @thedecorvases5643 2 года назад

    Great explanation

  • @syedsaeedulhassan6672
    @syedsaeedulhassan6672 2 года назад +1

    Short circuit men to resistance bhar jati he? Ya kam hojati he?

  • @babupt7780
    @babupt7780 2 года назад

    Good

  • @sumersinghmeena2880
    @sumersinghmeena2880 7 месяцев назад

    Good.idia

  • @sebidsouza4029
    @sebidsouza4029 2 года назад +1

    Sir I think running winding should have more resistant n phase wire is connected to running winding

    • @ElectricalTechnician
      @ElectricalTechnician  2 года назад +1

      The starting winding is wound with fewer turns of thin wire than the running winding, so it has higher resistance. The running winding is wound with large turns of thick wire than the starting winding, so it has lower resistance.

    • @javvadwankar4010
      @javvadwankar4010 2 года назад

      @@ElectricalTechnician you are Right

  • @mintumolla292
    @mintumolla292 2 года назад

    Nice

  • @kalpeshshah3857
    @kalpeshshah3857 4 дня назад

  • @haridas992
    @haridas992 2 года назад +2

    The capacitor value is 2mfd to 2.5mfd 250 volts AC.

  • @rabindranathkanteth2743
    @rabindranathkanteth2743 Год назад +6

    Starting winding resistance is less than running winding because starting winding have thick and less turn as compared to running winding

    • @nirmalkumartiwari9663
      @nirmalkumartiwari9663 Год назад +1

      Right

    • @Kishan_kinni
      @Kishan_kinni Год назад

      starting winding have high resistance because we have to create some phase difference to produce rmf

    • @11_akashkamble8
      @11_akashkamble8 9 месяцев назад +2

      Not thick it has thin so it has high resistance

    • @rakibtalokdar8567
      @rakibtalokdar8567 4 месяца назад

      ​@@Kishan_kinniBut someone says Running coil resistance is high 🐸

    • @i.dsharma5189
      @i.dsharma5189 4 месяца назад

      Bakbaas karta hai.ek hi baat ko bar bar bol raha hai.simple method to identify running winding,starting winding and common wire are colour code by red,black/blue and yelow..

  • @mkp1359
    @mkp1359 Год назад

    Bro please make videos on home alarm system on boush brand 2000 and 3000

  • @mitubarik3361
    @mitubarik3361 2 года назад

    Sir lift panel ki wiring kese hota hai ise ke uper vdo banaiye

  • @AnasAl-Dhafiri
    @AnasAl-Dhafiri 2 года назад +1

    Many thanks..please download pdf diagram?

  • @AnkitRajput-z6e
    @AnkitRajput-z6e 2 года назад +1

    Are bhai jab fan ko phase starting winding par denge to fan ka moter kharab nhi hoga kya

    • @ElectricalTechnician
      @ElectricalTechnician  2 года назад

      If the motor is Permanent Capacitor run motor than we give Power supply to running wire or starting wire, in both condition the two wire will get phase supply always
      So In ceiling fan & table fan we can give power supply to any of the wire
      But if you are using capacitor start motor ( means if there is centrifugal switch in motor ) than you have to give power supply to running wire only

  • @dasarathisatapathy2231
    @dasarathisatapathy2231 2 года назад +7

    Phase wire should be connected on running otherwise fan will run
    Opposite side .don, t give wrong information it will give a heavy loss to the new commers.

    • @ankr7.0
      @ankr7.0 2 года назад

      You are right sir
      Mai bhi yahi soch raha tha

    • @primewavez
      @primewavez 2 года назад

      Mostly indian RUclipsr
      Ceiling fan connection telling wrong.
      |^^^^^^^^^^^~~~~|~~~~0
      N ____| R =
      | S |
      |^^^^^^^'~~~~~~~|~~~0 Line
      Because
      Running wire size Less than Staring wire.
      example
      Running 30
      Starting 32 SWG
      so resistance 👇
      Resistance should be
      Com to Starting 240 Ω
      Com to Running 190 Ω
      Starting to Running 430 Ω
      Why they connect line on neutral with starting winding (high resistance end)
      👉But if you watch Pakistani or other RUclipsr video.
      they connect line on neutral with Running winding ( Low Resistance end)

    • @rambhaigurung960
      @rambhaigurung960 Год назад

      My question also 😢

    • @umeshpatil2543
      @umeshpatil2543 6 месяцев назад

      Right

  • @tahirali8463
    @tahirali8463 Год назад

    Bhai jis ki resistance ziyada ho wo running ho ga ya stating ye nhi bataya

  • @omarfarukomarfaruk730
    @omarfarukomarfaruk730 2 года назад

    Right

  • @kashi2843
    @kashi2843 Месяц назад

    5:00 starting winding ka resistance jyaada nahin kam hota hai running winding se. aap ulta bol rahe ho !!! starting winding is shorter than running winding length so stating winding cant have higher resistance than running winding.

  • @abdulrazakkheruwala509
    @abdulrazakkheruwala509 10 месяцев назад +1

    Celling fan me running winding ka resistance jyada hota hai or starting winding ka resistance kam hota hai
    Am i right???

  • @electronicshelpguide1479
    @electronicshelpguide1479 2 года назад +2

    Main supply hamesha Running winding pe honi chahiy

    • @Manavsain00
      @Manavsain00 2 года назад

      Bilkul sahi kaha aapne ye wrong bata raha hai

  • @kishanpardeshi7266
    @kishanpardeshi7266 2 года назад

    🙏❤️👌👍🖐️

  • @muhammedaflah7920
    @muhammedaflah7920 Год назад

    I am totally confused with ceiling fan,which core pole is of starting winding and which is of running winding?.i hope outer core is of running winding and inner core pole is of starting winding.is it correct?.when iam measuring the resistance of ceiling fan Resistance of running winding > Resistance of startingwinding

  • @bishwanathsingh8443
    @bishwanathsingh8443 4 месяца назад

    I have a fan . In which resistance between Red -- blue. 275. Red -- yellow 277 and yellow-- blue. 554 now. Comn is Red and running wire ( phase) is blue or yellow. Pls tell me.

  • @dhirenbasumatary5327
    @dhirenbasumatary5327 2 года назад

    Fan capactar 2:5 Afd

  • @rnpdabungboyesisback6645
    @rnpdabungboyesisback6645 2 года назад

    Capacitor value 1000 πF .

  • @prabodhkurmi72
    @prabodhkurmi72 Год назад

    Which winding has more resistance? and Why?

  • @panchalprashant8786
    @panchalprashant8786 Год назад

    Withou multimeter and seris testing lamp kese find kre konsa conection krna he

  • @akashbind4300
    @akashbind4300 2 года назад

    2.5 MFD से 3 MFD तक लगा सकते हैं

  • @sebidsouza4029
    @sebidsouza4029 2 года назад

    Inner winding is starting n outer winding is running winding so running winding got high resistance then starting winding

    • @ElectricalTechnician
      @ElectricalTechnician  2 года назад +2

      The starting winding is wound with fewer turns of thin wire than the running winding, so it has higher resistance. The running winding is wound with large turns of thick wire than the starting winding, so it has lower resistance.

  • @anandjaisemporrajsthanmeiy1079
    @anandjaisemporrajsthanmeiy1079 Год назад +1

    BHAI TUM LOG KAYA BATAY HAI KOI BOLTA HAI RUNING KI RESISTANCE JAYDA HOTI STARTING KI KAM KOI ULTA BOLTA HAI AISA KIYO?

    • @rambhaigurung960
      @rambhaigurung960 Год назад

      मे भी वोही confuse होरहा हु 😢😢😢

  • @pleasureofvoice9531
    @pleasureofvoice9531 2 года назад

    Sir har fan ka capacitor ka value kese measure Karin?

  • @seemabehera7045
    @seemabehera7045 Год назад

    2.5 sir

  • @darynflynn2154
    @darynflynn2154 5 месяцев назад

    I m getting 211 ohms, 199 ohms and 14 ohms in ceiling fan connection. What to do?

  • @ashishrawatssc
    @ashishrawatssc 2 года назад

    Me pahli baar fan ki winding ko ander se dekh raha hu

  • @mukeshsahu6144
    @mukeshsahu6144 4 месяца назад

    2.5 microfarad

  • @khileshverma8897
    @khileshverma8897 Год назад

    Yek me glow ni kr rha h kya problem hai

  • @ravikantgupta708
    @ravikantgupta708 Год назад

    40pf capacitor to be used.

  • @ayandhar5745
    @ayandhar5745 2 года назад +1

    Capacitor generally 2.25 microfarad use hota hai ceiling fan mein

  • @kaal4786
    @kaal4786 2 года назад

    2.5 micro faired

  • @sumankumarjena4292
    @sumankumarjena4292 2 года назад

    2.25 cap

  • @p.p.4192
    @p.p.4192 2 года назад

    Winding ok he capacitor ok he phirbhi speed kam kai se hota he

    • @alokkundu9263
      @alokkundu9263 2 года назад

      Capacitor ka dum nikl gya hoga change kro

  • @mahendrashewale3594
    @mahendrashewale3594 Год назад

    पेपर पर डायग्राम सीखाए

  • @biswanathmanna3445
    @biswanathmanna3445 2 года назад

    2.5 - 2.25 Mfd

  • @djmuslimbaliapur6364
    @djmuslimbaliapur6364 Год назад

    3.15uf

  • @anandaelectrical973
    @anandaelectrical973 2 года назад

    Point ke bad value zero hai to multy meter ko sudharen pehele

  • @mohdsameer-pw4tj
    @mohdsameer-pw4tj 2 года назад

    2.5 and 3.15 the sall

  • @SatishKumar-ut5dc
    @SatishKumar-ut5dc 2 года назад

    2.25 to 2.50 MFD

  • @harshalsananse2583
    @harshalsananse2583 2 года назад

    2.5 micro farad

  • @pardeepsharma9162
    @pardeepsharma9162 2 года назад

    Capisiter 2.5 ka lagega .

  • @SBhagat5
    @SBhagat5 2 года назад

    You also add your body resistance to wire resistance

  • @nadim606
    @nadim606 Год назад

    seen

  • @soumyasahoo3311
    @soumyasahoo3311 2 года назад

    2.5 capaciter

  • @poojamirdha4520
    @poojamirdha4520 2 года назад

    Ni no