Ceiling fan common, start, run wire identify with multimeter! Ceiling fan connection

Поделиться
HTML-код
  • Опубликовано: 16 апр 2020
  • 3 wire ceiling fan me common, start, run identify with multimeter
    In this video we explain 3 wire ceiling fan common, start, and running winding with multimeter. We know in ceiling fan their are two winding
    1.starting winding or auxiliary winding
    2.main winding or running winding
    We can identify these winding by measuring resistance
    We take resistance in all three terminal
    If resistance come high than these terminal or start and run
    Than other terminal is common
    Now take resistance between common to other two terminal than high resistance will be starting and low resistance running winding
    In this video we explain very easily for more information just watch and learn
    3 wire ceiling fan connection
    • CEILING FAN CONNECTION...
    Siemens drive parameter setting and connection
    • SIEMENS SINAMICS V20 D...
    How to calculate kwh or electrical bill calculation
    • WHAT IS KWH(UNIT)? HOW...
    Cable testing with multimeter
    • HOW TO TEST CABLE WITH...
    Reverse forward starter power wiring connection
    • REVERSE FORWARD STARTE...
    Manual reverse forward starter with limit switch
    • How to make Reverse fo...
    Automatic reverse forward starter
    • Star Delta starter pow...
    Automatic reverse forward motor starter connection
    • Automatic reverse forw...
    3 phase rccb test on single phase supply practical
    • 3 PHASE RCCB मे SINGLE...
    3 phase ammeter connection with selector switch
    • 3 PHASE AMMETER CONNEC...
    8 pin relay testing with multimeter
    • 8 PIN RELAY TESTING WI...
    How to check ceiling fan common start run with multimeter
    • 3 WIRE CEILING FAN COM...
    How to make dol starter with relay
    • How to make dol starte...
    How to check ceiling fan common start run with series lamp
    • Video
    ammeter connection with current transformer
    • 3 PHASE AMMETER CONNEC...
    Cooler motor testing with series test lamp
    • COOLER MOTOR TESTING W...
    Street light timer setting
    • STREET LIGHT TIMER SET...
    Air compressure power & control wiring practically
    • AIR COMPRESSURE के ST...
    3 phase cable testing with megger
    • HOW TO CHECK CABLE INS...
    3 phase motor test with megger
    • Induction motor test (...
    Dol starter control from different points
    • MOTOR CONTROL FROM DIF...
    How to make reverse forward motor starter
    • How to make Reverse f...
    Manual reverse forward starter with limit switch
    • How to make Reverse fo...
    Automatic reverse forward starter
    • Star Delta starter pow...
    Automatic reverse forward motor starter connection
    • Automatic reverse forw...
    Thanks for watching

Комментарии • 166

  • @JagiChan
    @JagiChan 3 года назад +8

    The video quality is good and the explanation is detailed and clear.👍🏻

  • @tripathi.harshmani
    @tripathi.harshmani 3 года назад +1

    thnq sir.. really very nice explanation.. i have just seen a video with more view count. but your video is much better and detailed

  • @Shaileshshivne
    @Shaileshshivne 3 года назад +1

    Bhut achha samzaye h aapne pehli bar me hi subscribe kr diya aapko

  • @NothingNew_01
    @NothingNew_01 3 года назад

    Achha explain kiye h sir...Thanks

  • @mistercool1191
    @mistercool1191 Месяц назад +1

    clear explanation...namaste..🙏🏽

  • @MrRamzanhabib
    @MrRamzanhabib Год назад

    Bohet acha samjhaya hai ap nae. Stay blessed brother

  • @sankarchandradeb8084
    @sankarchandradeb8084 Год назад +4

    In any types of ceiling fan running coil will show maximum resistance but in any other induction motor using pumping water and any other liquid will show minimum resistance in running coil, it's my practical experience. Thanks

  • @Durraniboy798
    @Durraniboy798 2 года назад +4

    Kyunki starting winding small hota hai isliye iska resistance Kam hona chahiye please explain sir ji

  • @prahladsingh9630
    @prahladsingh9630 2 года назад +1

    starting and running winding resistance value confusion create so clear my confusion

  • @jehirulislam1029
    @jehirulislam1029 4 года назад +7

    Supply running wire me dena sahia

  • @4629jay
    @4629jay 3 года назад +4

    Ceiling fan ki running winding ka resistance jyada kyu hota h outer coil ka jisme phase connect hota h
    Iss fan ki red wire running winding ki h outer winding aap check kijiye fan me running ka resistance jyada hota h

  • @mrigankachatterjee5870
    @mrigankachatterjee5870 Год назад

    Excellent explanation. Keep the good work

  • @iqrasteambathandsolutionmu763
    @iqrasteambathandsolutionmu763 3 года назад +1

    Thanks sir problem solved from Pune

  • @user-xr5nz1bg6j
    @user-xr5nz1bg6j 4 года назад +8

    connection rong ..starting winding wire centre connection karana..

  • @Zeeshankhan-qn5yv
    @Zeeshankhan-qn5yv 4 года назад

    Very easy explained identity to wire

  • @ashusain6595
    @ashusain6595 2 года назад +5

    I get confused. One says higher resistance is staring another says low resistance is starting, one says inner winding is sarting some says outer is starting!
    Low resistance= running ruclips.net/video/9s2NbqbwKWk/видео.html
    More resistance= Running ruclips.net/video/--wfOp-ScQg/видео.html
    low resistance= Starting ruclips.net/video/D1UsvW5RpPQ/видео.html
    Outer winding is starting or inner is starting
    If wire size is same in both starting and running winding then resistance of which winding will be higher, starting or running ?

    • @mitul2233
      @mitul2233 Год назад

      Bruh staring to common winding has higher resistance compared to running and common

  • @bhavinmaru4024
    @bhavinmaru4024 3 года назад +1

    Very good explain...👍

  • @virendrasinghsejwal-hu6dh
    @virendrasinghsejwal-hu6dh Год назад +2

    I saw other videos, they were saying phase shud be connected to running wire and not starting wire.

  • @4629jay
    @4629jay 4 года назад +3

    Red wali wire to outer winding/running winding se connect h na sir ji .???
    Bajaj ceiling fan data
    Starting winding mein number of turns 360 turns 36 swg
    Running winding mein 410 turns 36 swg

  • @jacobbabu607
    @jacobbabu607 Год назад

    Superb well explained

  • @Ankit_Sharma_88
    @Ankit_Sharma_88 4 года назад

    Please make individual video of
    How to make holding in contactor just like u made for 11 pin glass relay

  • @DharmendraKumar-re3sn
    @DharmendraKumar-re3sn 2 года назад +2

    Jiska value jyada he wo running coil he sahab aap usko starting bataraheho usme supply v deraheho

  • @ritwikbandyopadhyay2181
    @ritwikbandyopadhyay2181 2 года назад

    good and informative

  • @sarfarazbakali9357
    @sarfarazbakali9357 10 месяцев назад

    Thanks

  • @RatheeshRTM
    @RatheeshRTM 5 месяцев назад +1

    Well explained 👌👌thankyou🎉
    Running winding resistance low and starting high. AC or fridge compressor motor resistance is differant it's running resistance high and starting low! Am I right?

  • @mdtutorialgoon1448
    @mdtutorialgoon1448 2 года назад

    Thank you so much sir

  • @sudamnaik7633
    @sudamnaik7633 4 года назад

    Thanks sir 👍

  • @npnaidu4131
    @npnaidu4131 2 года назад

    Excellent 🙏

  • @Salloudintamoor6017
    @Salloudintamoor6017 Год назад +1

    Hello Bhupendra ji

  • @mdkhan5007
    @mdkhan5007 Год назад

    Thank you brother

  • @mandelasowjanya9643
    @mandelasowjanya9643 Год назад

    Very good explain

  • @TengrakMSangma
    @TengrakMSangma Год назад +1

    Sapke video alak alak hai bhai kuch video mein running wire koh phase diya aur aapke video mein starting wire koh aapne phase diya 😇😇😇

    • @SNTECHNICAL
      @SNTECHNICAL  Год назад +1

      Sir 3 wire fan me ap phase starting running kisi me bi de skte h fan jlega nhi
      But apko fan ko sida ghumaane k liye fan ko starting me dena hoga

    • @TengrakMSangma
      @TengrakMSangma Год назад

      @@SNTECHNICAL lekin ulta jayega bhai

  • @regencysarvam7206
    @regencysarvam7206 3 года назад +2

    Mera technician bolte hain Phase to be connected to Running and not to the starting... Common par neutral nagana hai.... please confirm.

  • @techview6933
    @techview6933 4 года назад

    Nice!!!

  • @Munny606
    @Munny606 3 года назад +1

    the fan rotates anticlockwise seen from below
    manufacturers install the 2.5MFD capacitor in the running winding(low resistance coil)
    in series instead of the induction motor theory that capacitor must be in series
    with the starter winding(high resistance coil)

  • @mangalagiriramesh5936
    @mangalagiriramesh5936 3 года назад +1

    Superb sir!

  • @parakramsinhzala6432
    @parakramsinhzala6432 2 года назад +2

    Resistance jyada vo running
    Resistance kum vo starting Right he
    But Is video me ulta bola he

  • @gnyankalita9829
    @gnyankalita9829 3 месяца назад

    Fan ki movment clockwise nisese ya uperse liya jata hai

  • @rakeshkumarmaurya416
    @rakeshkumarmaurya416 4 года назад +5

    Lamp se Batao sir

  • @realitykol6934
    @realitykol6934 2 года назад +2

    3:25 starting ka resistance kum hota hai running ka zayada hota hai kyu ki running coil bahar hota hai aur wo zayada bada hota hai. Thek se pata kijiye bhai! Aise me sekhne walo ko garbar ho jayega.

    • @shriharikokare5764
      @shriharikokare5764 2 года назад

      sahi hai bhai..
      lekin theroy me
      running winding conductor size mothi hoti hai compare to starting winding isliye theroy me running winding ka resistance kam hota hai..
      practically same conductor size use karte hai.. isliye practically me running winding ka resistance jyada hota hai

  • @shafanhussainmew2932
    @shafanhussainmew2932 4 года назад

    Very nice bhai

  • @subhankarsarkar4800
    @subhankarsarkar4800 4 года назад +2

    Sir tebil fan ka canection btya

  • @farahabdi8616
    @farahabdi8616 4 года назад

    Thanks sir

  • @shahidsarker8339
    @shahidsarker8339 Год назад

    very nice video

  • @cncmachines9836
    @cncmachines9836 3 года назад

    nice

  • @SwingMotor
    @SwingMotor 3 года назад +1

    Nice concept

  • @dot.sattamatka6356
    @dot.sattamatka6356 2 года назад

    सर फॅन के starting winding को phase diya जाता हैं या running winding को? प्लीज जवाब दे

  • @mangeshpatil283
    @mangeshpatil283 Год назад

    Super

  • @engineeringdepartment4688
    @engineeringdepartment4688 3 года назад +7

    Start winding must be one ended capacitor and other winding end must be supply plus capacitor

  • @anishresho9145
    @anishresho9145 3 года назад +1

    Is single phase winding connection common to all motors and other appliances, mixie,washing machine,Grinder,Ceiling fan,Pedastel fan and Table fan

    • @professionalrepairpr4737
      @professionalrepairpr4737 2 года назад

      Mixer- universal motor
      Washing machine- semi automatic induction motor , automatic induction motor, front loading washing machine universal and DD motor use,
      Grinder universal motor use ceiling fan induction motor
      Pedastal,table use single phase induction motor

  • @MDMEHEDIHASAN-gy8fs
    @MDMEHEDIHASAN-gy8fs Год назад

    ❤️❤️❤️❤️

  • @murtidevi3266
    @murtidevi3266 3 года назад

    Very nice

  • @Mohd_Hassan480
    @Mohd_Hassan480 4 года назад +1

    ....jab single pole ki mcb koi load me connect hai yaa manlo ghar ke main.. Bord me connect hai aur neutral direct hai.. To koi bhi short cercuit me hamari mcb single pole wali trip ho rahi hai.. To hum 2 pole ki mcb q lagate hai. Iska kya reasion hai.. Kya 2 pole ki mcb jaruri hai ....plzz reply me.

    • @techchannel4173
      @techchannel4173 3 года назад

      Two pole mcb mei dono phase and neutral control hota hai iske baad neutral ko har point mei dena hai

  • @mdnafis8220
    @mdnafis8220 3 года назад

    Sir padastal fan ka connection bataye multimeter se

  • @nareshkumarbarot3043
    @nareshkumarbarot3043 3 года назад

    Good

  • @saravanamg7593
    @saravanamg7593 Год назад

    Very good

  • @professionalrepairpr4737
    @professionalrepairpr4737 2 года назад

    Kishi bhi induction motor ki starting running common vending ko identify karne ke liye sabse simple Jin do terminal per sabse jyada resistance aati hai usse bacha hua terminal common hota hai common to Ho Gaya common ke sath jis terminal per sabse jyada resistance aati hai vah starting bending hoti hai Jo last mein bacha hai wah running vending ho gai....

  • @yograi6639
    @yograi6639 2 года назад

    good video

  • @h.d.veerarajeursmysore4043
    @h.d.veerarajeursmysore4043 3 года назад

    Super sir

  • @tipusultan6685
    @tipusultan6685 2 года назад

    Running wire upar me lagega bro starting wala bich me aise hoga

  • @sannichaudhary1825
    @sannichaudhary1825 3 года назад

    To good bhai

  • @sandeepmohapatra8659
    @sandeepmohapatra8659 2 года назад

    Sir starting wire me phej dena chahiye yaa running wire me?

  • @tipusultan6685
    @tipusultan6685 2 года назад

    Common or running me main suply jayega bhai

  • @Salloudintamoor6017
    @Salloudintamoor6017 Год назад

    Hello Bhupesh ji

  • @venkataraomadisetty4392
    @venkataraomadisetty4392 Год назад

    What are the connected wire gauze from starting. Running & comon

  • @arunthangaraj8364
    @arunthangaraj8364 4 года назад +1

    fan always rotates in anticlockwise

  • @ismailmohammed5588
    @ismailmohammed5588 2 года назад

    Sir ceiling fan rotates anti clock wise iam correct

  • @HarHar_Mahadev198
    @HarHar_Mahadev198 Год назад +1

    Wao mast bro

  • @pankajchhetri4901
    @pankajchhetri4901 2 года назад +1

    Running coil me turn jyada hote hai to resistance bhi jyada hoga

    • @SNTECHNICAL
      @SNTECHNICAL  2 года назад +1

      Nhi running coil me jo wire use hota h vo mota hota h
      Isliye resistance km hoga
      Or resistance km hoga tbi current jada flow hoga

    • @pankajchhetri4901
      @pankajchhetri4901 2 года назад

      @@SNTECHNICAL ok sir

  • @prashantpatel39666
    @prashantpatel39666 2 года назад

    Srating me dege to fan nahi jalega ?

  • @SoumenDalapati-up2sx
    @SoumenDalapati-up2sx Месяц назад +1

    Me vi ahi kahe raha ta

  • @babukartik6124
    @babukartik6124 Год назад +2

    Running kaa resistence jyaadaa honaa chahiye. Aapne running kaa kam dikhaayaa?

  • @shafiahmed2880
    @shafiahmed2880 2 года назад

    Sir normalse starting aur runningke beechme capacitor lagayajathahai.aur phase running windingkesath lagaya jathahai.lekin sirf ceiling fanmehe phase starting windingse lagayajathaheykya sir?

  • @greatestIndia-
    @greatestIndia- 5 дней назад

    Is multimeter k pins k upar cap hoti he dono ko khinch k nikaal do to andar 2 cm pin aa jayegi..

  • @Runnergaming101
    @Runnergaming101 2 года назад +1

    Common wire hmesa niche lagana hota h kya sir?

    • @SNTECHNICAL
      @SNTECHNICAL  2 года назад

      Ap sbse niche bi lga skte h ya sbse upr bi lga skte h
      But kbi bi bich me nhi lgana h

    • @Runnergaming101
      @Runnergaming101 2 года назад

      @@SNTECHNICAL Thnks sir❤🙏

  • @spartankinga2659
    @spartankinga2659 2 года назад

    பேன் ஓடிய சிறிது நேரத்தில் ரொம்ப சூடாகிறது . பேன் ஓடமாட்டங்கிறது என்ன செய்ய தயவுசெய்து சொல்லுங்கள்

  • @himanshuchandwani7494
    @himanshuchandwani7494 8 месяцев назад

    Bhai starting wire ki reading kam hoti h and running ki jyada ho sake to ek bar check karke video sudar do

  • @rajivkatara3419
    @rajivkatara3419 4 года назад

    Video on table fan connections?

  • @maheshpal1636
    @maheshpal1636 2 года назад

    Bulb sirij se batave please

  • @ArvindKumar-hk4ht
    @ArvindKumar-hk4ht Год назад

    Hello Bhai

  • @chintadav.suryarao2579
    @chintadav.suryarao2579 3 года назад +4

    Your explanation is good. But Cum resistance vala starting winding....high resistance vala running winding.

  • @nandumeshram4656
    @nandumeshram4656 2 года назад

    भाई. Running wire मे दोनो सिरे से multimeter से reading 47-56 आ रहा है.साथ मे कभी कभी बिप की आवाज भी आती.तो क्या ये reading सही है क्या. और स्टेटर मे भी reading बताता है. क्या fault होगा

    • @Rahul.patel48
      @Rahul.patel48 2 года назад +1

      Body earth nhi hona chahiye wire kahi se body se touch hoga isiliye stator par continuity mil rhi

  • @Vickykumar-hu1in
    @Vickykumar-hu1in Год назад

    Running wale mein face dena hai bhai ji aur Koman Newton dena

  • @NurIslam-ji9so
    @NurIslam-ji9so Год назад

    ❤Agor show na ho to Kay kore ।

  • @dattavaze1982
    @dattavaze1982 11 месяцев назад

    What happens in the fan if a capacitor is connected to the common wire

  • @phepdhosl7697
    @phepdhosl7697 2 года назад

    How to check coil in fan multimeter

  • @saifazmi534
    @saifazmi534 Год назад

    Point 506 lijiyea

  • @primewavez
    @primewavez 2 года назад

    R u know about
    Electric and winding
    or just video making.
    How give the power supply to starting and common
    Always
    Power supply give to
    Running and common
    Starting connect with capacitor

  • @shamsilyas8885
    @shamsilyas8885 4 года назад +2

    Bahi jan connection wrong hain....neutral/phase running k 7 dainy hai..
    Jab I starting ko khuch nahen daina....

    • @SNTECHNICAL
      @SNTECHNICAL  4 года назад

      3 wire me starting me dena hoga
      Running me doge to fan reverse direction me run hoga
      Ap check kr skte h

    • @laxmannagula123
      @laxmannagula123 3 года назад

      Rong connection

  • @r90135
    @r90135 4 года назад +9

    Totally wrong

    • @NOT-A-STAR_GAMING
      @NOT-A-STAR_GAMING 5 месяцев назад +1

      Why?

    • @hehahu-wx2gn
      @hehahu-wx2gn 3 месяца назад

      if u say its wrong without saying what is the right it means u r totally asshole. specially that it is 100% right and u r the wrong asshole

    • @TheArifSarker
      @TheArifSarker 16 дней назад

      Right

  • @RakeshKumar-bt4dv
    @RakeshKumar-bt4dv 3 года назад

    फैन अगर जला हुआ है तो मल्टीमीटर रीडिंग दिखाएगा या नहीं दिखाएगा

  • @techchannel4173
    @techchannel4173 3 года назад +2

    Sir yellow is common but black is starting and Red is Running. Kyuki Running mei turns jyada hota hai so Resistance bhi jyada hoga.plz explain sir

  • @sahabuddinlaskar7863
    @sahabuddinlaskar7863 2 года назад

    Sir app galat bolrhaho. Commen wir K saath starting war ka repentance kam hoga. Or runing war me jada hoga.

  • @nadim606
    @nadim606 9 месяцев назад

    seen

  • @NyvaanSribastav
    @NyvaanSribastav Год назад +1

    Ko to bich mein bhi de sake Na bhai jo commonweal hota hai usko to ham log bich mein bhi de sakte hain ki middle mein aur jo running aur starting mein hua hota hai vah upar kar aur upar ke side aur niche karo side de sakte hain ham log to Bhai niche ke side mein aise de rahe ho bhai to confuse ho jaenge bhai ham log kya hai tum dikha rahe Ho video kuchh achcha sa batao kuchh samajh mein nahin a raha hai bhai aise Tum Bhai pata hai Bhai tumko pata hai ham log Ko nahin pata ham log abhi Sikh rahe hain but Aisa kuchh mat batao yaar samajh mein nahin aata hai

  • @herik63
    @herik63 3 года назад

    Ok the English title, but the subtitle?

  • @shayeeqhmuzammil981
    @shayeeqhmuzammil981 4 года назад +1

    Slow fan ku kay karna hai

    • @Munny606
      @Munny606 3 года назад

      change the capacitor, install the round can type not the black square type

  • @rambhaigurung960
    @rambhaigurung960 11 месяцев назад

    ये आप्का उल्टा घुमेगा
    Fase और नुटन common our running+capacitor मे लगेगा
    लोगो को सहि जानकारी दे confuse ना करे प्ल्ज़ thanks 😮

  • @ashernajmi
    @ashernajmi 2 года назад

    connection points not clearly shown

  • @4629jay
    @4629jay 4 года назад +1

    Aap ye wala fan open krke dikha skte ho kya red wire outer/running winding se connect h ya inner/starting winding se 🙏🙏🙏
    Mera doubt clear hojayega