How to Replace an Expansion Tank

Поделиться
HTML-код
  • Опубликовано: 16 ноя 2024

Комментарии • 19

  • @garywalls9041
    @garywalls9041 9 месяцев назад +3

    Don't forget to check water pressure with a hose bib gauge and set the air pre-charge on the expansion tank to match so that the tank starts in a neutral or balanced condition between the water pressure and air pressure inside the tank.

  • @chrismoore9433
    @chrismoore9433 5 месяцев назад

    Did you recommend a pressure regulator? Would probably save the homeowner more troubles in the future.

  • @merllhagard6799
    @merllhagard6799 9 месяцев назад +2

    I would've piped that tank against the wall so it could be strapped. Other than that, this is a good replacement.

    • @PlumbHero
      @PlumbHero  9 месяцев назад +1

      Nice, we aren’t required to strap but I see what you mean

  • @johnhuynh9445
    @johnhuynh9445 8 месяцев назад +1

    Does the expansion tank need to be supported with additional brackets?

  • @Moshegoldman
    @Moshegoldman 9 месяцев назад +1

    Love your videos!
    Would love to hear from you what hot water tank you would recommend, what company as well as what size, I’d say, household is roughly for adults, and for children

    • @PlumbHero
      @PlumbHero  9 месяцев назад +1

      Thanks! State water heaters are great as well as Bradford white. 50 gallon if you have a family.

    • @Tsiikki
      @Tsiikki 9 месяцев назад +1

      Get a stainless steel one. My last one was 1985. Replaced in 2017.

  • @endtimes3798
    @endtimes3798 9 месяцев назад +2

    Nice job , go figure a respectable plumber. God Bless

  • @aaronbaraiya3692
    @aaronbaraiya3692 9 месяцев назад

    Can any nipple be used to attach a pipe to a water heater? Like wat u did at 1.11?

    • @PlumbHero
      @PlumbHero  9 месяцев назад +1

      Dielectric nipples are what you should use

  • @hectorworksout
    @hectorworksout 8 месяцев назад

    The expansion tank does nothing to prevent the T&p valve from going off
    As you said the house pressure is 120 which is absurdly high
    The T&p valve goes off at 150psi
    Which pressure increases at night significantly
    His main issue is to replace the pressure regulator cause if not it will keep happening

  • @jacktheplumber1
    @jacktheplumber1 9 месяцев назад

    Nice one

  • @jacknabox2158
    @jacknabox2158 3 месяца назад

    I have never seen a expansion tank before in 60+ yrs. Never had one for any of my water heaters nor my parents, friends or relatives. Ate they really necessary??
    I do have a well water pressure tank.

  • @Jus-k2m
    @Jus-k2m 9 месяцев назад +1

    Every thought about doing reactions from subscribers?

    • @PlumbHero
      @PlumbHero  9 месяцев назад

      What do you mean

  • @met8886
    @met8886 7 месяцев назад

    Why is it I see so many plumbers nowadays (younger guys) using pump pliers the wrong way? It’s not just you.

  • @daddy1571
    @daddy1571 8 месяцев назад

    They make an easy strap kit for those tanks. It's not a code requirement but it's good practice.