IT WENT BANG!!! A LOT OF BROKEN DAIKIN AIR CONDITIONING! HVAC UK

Поделиться
HTML-код
  • Опубликовано: 18 окт 2024

Комментарии • 61

  • @im_al9274
    @im_al9274 4 года назад +10

    Hi , the service valve caps had probably been over tightened hence the separation .
    Good content
    All the best

  • @TedCookHVAC
    @TedCookHVAC 3 года назад +1

    Firecrackers !! Great video thanks for sharing.

  • @stevebajada5992
    @stevebajada5992 3 года назад +4

    Lack of maintenance for sure. The blown capacitor is a missing neutral. From the video the isolator do not get checked regularly for loose contacts. Had worked years with daikin never had such issues.

  • @marksmith6259
    @marksmith6259 3 года назад +6

    That moisture growth plus looks like all units in a well, get very hot in summer, but in heating they would just recirculate the cold and that would be very bad for them. Top discharge vrv with a round duct to exhaust air away from roof area might have been a good design consideration,
    Also are these units getting the oil back? What sort of rise does the suction line make?

  • @setitthen
    @setitthen 2 года назад +2

    Would an oscilloscope help as an addition to your tool box. You can look at current waveforms they can tell you a lot of what's happening. Sorry to be intrusive on your work just a thought. Very helpful watching what you do. Good work 👍

  • @allandewar
    @allandewar 3 года назад +7

    I regularly find if the compressor is seized or down to earth , that the inverter pcb will also be fooked

    • @jackmule1572
      @jackmule1572 3 года назад

      Then that is not cheap repair, if the inverter pcb is fooked

  • @craigladewig3158
    @craigladewig3158 3 года назад +8

    Hate quoting on repairs on inverter units, replace one thing to find something else faulty. Nothing beats a simple DOL compressor with no fancy electronics. Replace a costly inverter pcb and the money you saved in power costs goes out the window

    • @myshadowkungfu
      @myshadowkungfu 3 года назад +1

      Yes. This is high efficiency trash.

  • @georgeian3243
    @georgeian3243 3 года назад +6

    Judging by the mold growing on the cabinets I’m thinking excessive humidity might be a problem? I recall working with some conventional heat pump defrost control boards years ago that had inadequate conformal coatings allowing moisture to seep into several components causing failures. Too bad so many units failed...maybe maintenance issues as well? I like your tool kit...cheers from Canada.

  • @jkepps
    @jkepps 3 года назад +1

    I'm just here for the music! LOL! And the HVAC info too.

  • @thomasg1117
    @thomasg1117 3 года назад

    I died when you unlocked the roof door lol!!!!!!

  • @AustinAirCo
    @AustinAirCo 3 года назад

    One of them went bang. *broken, broken, broken, broken* Hilarious. Greetings from Katy, Texas USA.

  • @KuntalGhosh
    @KuntalGhosh 2 года назад

    looks like some kind of power surge issue cus bad caps with age do not explode violently they just go high internal resistance . also the choice of outdoor unit is bad , the units should have top discharge in this type of location . side discharge is good when u set these up on walls or have few units for residential install .

  • @bryansimon4072
    @bryansimon4072 3 года назад

    Hello from the U.S. have found Dankin rf units don’t hold up in high moisture environments . Have 2 customers with these , 3 year old units constantly broken, we’re pricing replacement with conventional units now. Don’t like dankin in coastal areas they just fall apart. Good luck

  • @robindenbeste5472
    @robindenbeste5472 3 года назад

    Thank you.

  • @rickchan3789
    @rickchan3789 3 года назад

    Another great video

  • @allandewar
    @allandewar 3 года назад +2

    Looks like you work in all the same areas around Brum as me ! And you drove past a house in Hampton in Arden that I used to live in 👍

    • @hvacuk8975
      @hvacuk8975  3 года назад

      Fellow Brummie 🙌🏼👊🏼👍🏼 Yes mate, try and keep all the service work in the Midlands.
      Do you do much in the centre ? Nice area Hampton in Arden 👌🏼

    • @allandewar
      @allandewar 3 года назад

      I live in Coleshill, not a Brummie 😆 Ime a Jock 🏴󠁧󠁢󠁳󠁣󠁴󠁿 lived down here 40 years 🤪

    • @hvacuk8975
      @hvacuk8975  3 года назад +1

      @@allandewar not a million miles away 👌🏼 I’ve got family in Scotland 🏴󠁧󠁢󠁳󠁣󠁴󠁿 👍🏼👍🏼

    • @jameslewis875
      @jameslewis875 3 года назад

      I was thinking the same thing. Do you work for yourself or a company. Need someone to service some equipment in chelmsley wood I do heating and BMS

    • @allandewar
      @allandewar 3 года назад

      @@jameslewis875 how many units , what brand AC are they and where in the Wood ?

  • @JuanTodoli
    @JuanTodoli 3 года назад

    What a row!

  • @torrenstransitenthusiast6985
    @torrenstransitenthusiast6985 3 года назад

    Very impressive and informative

  • @simonac688.
    @simonac688. 3 года назад +3

    Sir i have your invoice...loll hold my champagne loll 🥂

  • @tomwardzala4240
    @tomwardzala4240 4 года назад +2

    How’s HVAC business in UK ? Do you guys have a lot of central A/C at residential or it’s pretty much ductless everywhere ?

    • @hvacuk8975
      @hvacuk8975  4 года назад +4

      Hey mate 👍🏼 Things are starting to pick back up now after the whole Covid-19 lockdown.
      The majority of our air conditioning is commercial it’s not very common for people to have air conditioning in their homes.
      We do have central plant which could include what we call Package Units, Air Handling Units, Chillers and Boilers. But most of the kit I work on is VRF, splits etc or ductless you guys call it 👍🏼👍🏼👍🏼

    • @JulianPardenilla
      @JulianPardenilla 3 года назад

      @@hvacuk8975 US also calls them package units or rooftop units

    • @bradroesler7072
      @bradroesler7072 8 месяцев назад

      What's with the severe lack of RUclips videos? Is everything alright in your neck of the woods?

  • @delrey-p
    @delrey-p Год назад

    Parked at snow hill by any chance haha

  • @Keith-jj2oh
    @Keith-jj2oh 3 года назад

    What brand do you guys recommend for reliability?

  • @jimdefilippis9630
    @jimdefilippis9630 3 года назад +1

    One good thing, looks like we should not run out of work with all this high-tech technology~ Lmao - (Broken, Broken, Broken,Broken)

  • @andrewedis9907
    @andrewedis9907 3 года назад +1

    That's the saddest sounding compressor 🤣

  • @stephenhunter70
    @stephenhunter70 3 года назад

    Daikin error code e7 E7 indicates that the fan motor/s in the outdoor unit is not working properly. Which you already knew!

  • @richardc1983
    @richardc1983 3 года назад

    Loving your channel usually only see the USA stuff on here. In your opinion why had all these units failed? Old age or abuse such as running at minimum and maximum setpoints all the time?

    • @LC-qi5ff
      @LC-qi5ff Год назад

      Or daikin is shite

  • @lainj94
    @lainj94 3 года назад +1

    Not really familiar how a heat pump AC works, but from what I see the way they install the outdoor unit it's directly facing each other in such confine space. Pretty sure if it's running in cooling mode the hot air will definitely trap inside and I don't think the compressors will survive for long 😂 That's my experience in South East Asia hot country tho

    • @Bryan-Hensley
      @Bryan-Hensley 3 года назад

      A heatpump should have more "breathing" area than an AC because cold air hugs the ground and gets recirculated back through the unit

  • @NaathanR
    @NaathanR 3 года назад +1

    What does “compressor down to earth mean?”

    • @stephenhunter70
      @stephenhunter70 3 года назад +2

      The motor windings insulation is faulty. The current then takes the shortcut instead of via the winding.

    • @myshadowkungfu
      @myshadowkungfu 3 года назад +3

      The coating around the wire, inside the cpmpressor, has melted and the wire is now touching metal. Hence, "continuity" between it and earth/ground. In the USA, we say its a grounded compressor.

  • @OcRefrig
    @OcRefrig 4 года назад +3

    All Junk. 😂🤣😂🤣 Daikin. How old were they ? Subbed. Like # 24

    • @hvacuk8975
      @hvacuk8975  4 года назад +2

      OcRefrigeration , Hvac & Electrical Video's. 😂 definitely more not working than working 🤦🏻‍♂️ I think they were about 10 years old. Probably had a hard life 😂🤦🏻‍♂️

  • @francovanmarrewijk
    @francovanmarrewijk 4 года назад +2

    Wtf happend over there?? Mega power surge?

    • @mennoregts208
      @mennoregts208 3 года назад +1

      I think Thor payed them a visit and dropped his hammer.

    • @pigrew
      @pigrew 3 года назад +1

      My guess is mains voltage was applied to the chassis... Maybe the compressor failed, the "Earth" wasn't earthed or neutral open, and that lifted the chassis voltage up to mains level, causing all the other failures?

  • @pattes123
    @pattes123 3 года назад +2

    This is why you dont use Daiken.... Job security for you I guess lol

  • @mkm-me9hy
    @mkm-me9hy Год назад

    2:20

  • @donnierobertson3088
    @donnierobertson3088 3 года назад

    Ok

  • @josemilano3601
    @josemilano3601 4 года назад

    Jajajajaja as in venezuela

  • @cthorn8355
    @cthorn8355 3 года назад

    Simply speak English. Says the American...

  • @oakley240583
    @oakley240583 3 года назад

    Daikin = 🤮🤮🤮
    Over priced and over engineered with no major benefits, I wish consultants would look at other manufacturers before sticking to Daikin constantly.

    • @h.kurnia8175
      @h.kurnia8175 3 года назад +1

      What do you recommend for mini split unit? Here where I live Daikin Inverter mini splits are popular for residential other than Panasonic

  • @BLAZENYCBLACKOPS
    @BLAZENYCBLACKOPS 3 года назад +2

    Daikin is garbage.