Finding and Fixing Natural Gas Pipe Leak

Поделиться
HTML-код
  • Опубликовано: 25 янв 2025

Комментарии • 33

  • @billbrasky8904
    @billbrasky8904 2 года назад +33

    If I ever get a gas leak, please let it be on an end cap. LMAO

  • @LargerThanCats
    @LargerThanCats Год назад +6

    Great video! Simple and straightforward with all the fat trimmed.

  • @givantichy
    @givantichy 2 года назад +15

    IMHO, may want to use two wrenches in the future to isolate your torque. Don’t want to disturb the existing joints!

  • @tonyp8808
    @tonyp8808 2 года назад +11

    Some tape? Used enough for about 2 connections.

  • @JohnDoeEagle1
    @JohnDoeEagle1 2 года назад +6

    Hate to tell you that as a professional licensed HVAC tech for 20 years that if your Windex or soap bubbles don't show a leak neither will that meter. You must have missed checking that joint or didn't see the bubbles or fizzing. If you "smell" gas it means it can't even hold .5 or 1/2 PSI. Most municipalities require either 10 PSI or 15 PSI of inert gas (compressed air or nitrogen) to hold for at least 24 hours.

  • @all4heatinggaslimited40
    @all4heatinggaslimited40 9 месяцев назад +1

    Wish I could find a gas leak like that to repair 😂😂😂

  • @markheathcote4230
    @markheathcote4230 3 года назад +1

    Hi what is the detector you used

  • @walterbrunswick
    @walterbrunswick 3 года назад +7

    You applied way too much Teflon tape. You only need 3-4 wraps max. on pipe sizes 1/2" and 3/4" NPT (it's the TPI that is important, not diameter).
    Also you didn't use a backup pipe wrench when tightening, putting a lot of stress on the pipe, in a sideways direction no less (not good).

  • @nickali8070
    @nickali8070 3 года назад +2

    Sir will get the job of natural gas, I am from India , Indian company name Mahanagar Gas 3 years experience please

  • @aamirshahzad8060
    @aamirshahzad8060 3 года назад +3

    Pipe dope would have helped too.

  • @deepsonadas8376
    @deepsonadas8376 Год назад

    Gas detectors finds gas leakage: GAS GAS GAS GAS GAS EVERYWHERE

  • @TheRabidPosum
    @TheRabidPosum 3 года назад +4

    In NY we use lamp wick and pipe dope. Never teflon tape on oil or gas piping. It's actually against code.

    • @brianapel8404
      @brianapel8404  3 года назад

      Well the yellow tape is allowed here. 🤷‍♂️

    • @TheRabidPosum
      @TheRabidPosum 3 года назад

      @@brianapel8404 on propane too? I never saw that. How about oil (died diesel fuel)? I would think it would just discenigrate it.

    • @brianapel8404
      @brianapel8404  3 года назад +1

      @@TheRabidPosum Don't know about propane or oil piping. But it's allowed for residential low pressure natural gas piping at least, and for me--that's all I care about! :-)

    • @walterbrunswick
      @walterbrunswick 3 года назад

      I stopped using pipe dope in 2016; PTFE tape only, on potable, heating water, nat. gas and propane
      Licensed gasfitter in Toronto Canada
      I highly doubt Teflon tape is against code in NY (for nat. gas)

    • @TheRabidPosum
      @TheRabidPosum 3 года назад

      @@walterbrunswick it is, and I have never seen it in the field, commercial or residential. Only dope.

  • @marymorgan1287
    @marymorgan1287 Год назад +1

    One important thing...get all that crap hanging on gas lines OFF. Dangerous!

  • @bert1913
    @bert1913 8 месяцев назад +1

    Try farting on your detector and see what happens

  • @chonglee323
    @chonglee323 7 месяцев назад

    You guys took the easiest place to leak a pipe lol thumbs down

  • @jeffreyjohn2037
    @jeffreyjohn2037 3 года назад +2

    You didn't use enough tape 🤡

    • @brianapel8404
      @brianapel8404  3 года назад

      Haha! Thanks for that. Yeah, bit of a rookie move on my part, but it doesn’t hurt anything.

    • @jeffreyjohn2037
      @jeffreyjohn2037 3 года назад

      @@brianapel8404 don't use tape on gas. Gasoila is the best! 🏆

    • @JohnDoeEagle1
      @JohnDoeEagle1 2 года назад +1

      @@jeffreyjohn2037
      Tru Blu or Leak Lock is the best.
      Can you put a hose onto a barb fitting with Gasoila like Tru Blue or Leak Lock and a clamp then pressurize it to 120+ PSI with no leaks or blowing apart? That is probably a negative ghost rider.