Neighbor HIT This Gas Line! - Gas Line Repair (Plumbing POV)

Поделиться
HTML-код
  • Опубликовано: 23 май 2024
  • Today I'm repairing a gas line that was hit by a car! Plumbers in Texas work on the gas all the time, it's a part of what our job entails. Today I'm giving you a POV of what a gas line repair looks like. If you want to see my work on a gas line, check this video out and let me know what you think!
    ► UP NEXT:
    What to Do if You Have a Gas Leak - • What to Do If Your Hou...
    Things Homeowners Need to Know About Gas Meters - • 3 Things Homeowners NE...
    ✅LET’S STAY IN TOUCH: stan.store/RogerWakefield
    🔔 Subscribe for more AWESOME plumbing videos: / @rogerwakefield
    ⭐️ Become a Member TODAY: / rogerwakefield
    ________________________________________________________________________________________________
    ✅ For business inquiries contact me at contact@rogerwakefield.com
    ________________________________________________________________________________________________
    🔴 Links:
    My fav equipment & tools - www.amazon.com/shop/rogerwake...
    My Free Mini-Course- bit.ly/rogersfreeminicourse
    My Networking Secrets That Grew My Plumbing Business FAST - bit.ly/rogersfreeguide
    PlumbStudy- plumbstudy.thinkific.com/
    My Recommended Plumbing Study Guide -amzn.to/2RgYEn5
    ________________________________________________________________________________________________
    Thanks for watching! I'm Roger Wakefield, The Expert Plumber, and welcome to my channel. On this channel, it's ALL about plumbing. We play games, we experiment, and we have FUN here, talking and learning about all things plumbing!
    ____________________________________________________________________________
    *NOTE: This description contains affiliate links that allow you to find the items mentioned in this video and support the channel at NO COST TO YOU. While this channel may earn minimal sums when the viewer uses the links, the viewer is in NO WAY obligated to use these links. Thank you for your support!

Комментарии • 1,1 тыс.

  • @RogerWakefield
    @RogerWakefield  4 года назад +116

    Like this if you've ever worked on gas lines
    See more plumbing service calls: ruclips.net/p/PLSpTuwsLqh7t-C39a5zmjEX5pnP6ySiqx

    • @evomike2122
      @evomike2122 3 года назад

      I did a lot of gas piping and I also learned to tape and dope

    • @robertlewis4198
      @robertlewis4198 3 года назад

      I never use teflon on gas I only use grip

    • @jielin1692
      @jielin1692 3 года назад

      Copper all the way in Australia

    • @starry885
      @starry885 3 года назад +6

      In Los Angeles, it is against code to use Teflon tape on gas joints, you are only supposed to use dope. It is to prevent chunks of Teflon from getting in the pipe and reaching gas fixtures, and blocking the small orifices on them, like pilot lights. Is Teflon code where you work?

    • @jebbyhut4711
      @jebbyhut4711 3 года назад +1

      I could only imagine how much that thread cutter comes in clutch, keep up the awesome vids

  • @armandomadrigal9793
    @armandomadrigal9793 4 года назад +548

    I'm with you Roger, I put teflon, and pipe dope. I even put some pipe dope in my morning coffee.

    • @cliff8101
      @cliff8101 4 года назад +19

      Next time I do any gas work here I am going to definitely remember that trick us oil field pipe line guys are just used to the pipe dope only

    • @franklinprichard9151
      @franklinprichard9151 3 года назад +7

      I usually use both but I've always been taught to never use tape by itself.

    • @GG-tt3sg
      @GG-tt3sg 3 года назад +2

      Thats right lol

    • @cliff8101
      @cliff8101 3 года назад +4

      Update: I had to change up some gas line for my tankless it worked great

    • @laynejohnson4289
      @laynejohnson4289 3 года назад +4

      Double the protection 👍🏻 Teflon and Pipe dope

  • @pospc2
    @pospc2 3 года назад +261

    No idea why you popped up in my feed but I'm glad you did. Been Binge watching.

  • @bradleyselk9642
    @bradleyselk9642 3 года назад +89

    When I was a teen and had just started helping my dad on sites he said to check for gas leaks smoke a cigarette.
    I asked him how does that work.
    He said If you live you did a good job 😁
    I miss that old man.

    • @smellymeadowhel8763
      @smellymeadowhel8763 3 года назад +9

      So he blew up?

    • @bradleyselk9642
      @bradleyselk9642 3 года назад +9

      @@smellymeadowhel8763
      No heart attack, 47 years as a carpenter finally caught up with him.

    • @benjamincain4778
      @benjamincain4778 3 года назад +1

      That’s true up to about 20 years ago here too. Most gas leaks are quite small on low pressure house lines.

    • @a_mustache_of_great_repute
      @a_mustache_of_great_repute 2 года назад +1

      The cig will never ignite natural gas. Lighter will though.

    • @FireHorse11291966
      @FireHorse11291966 2 года назад

      @@a_mustache_of_great_repute what if you drop a lit cigarette with gas around?

  • @scottfindlay2625
    @scottfindlay2625 3 года назад +172

    Those meters wouldn't be legal here, they must be at the side of the house.. Thats just plain nuts having them out by the roadway especially without big concrete filled protection rails..

    • @tanner8705
      @tanner8705 3 года назад +2

      facts

    • @morganrussman
      @morganrussman 3 года назад +17

      And to be honest, I don't know how or why the meters that close to the road in the 1st place.

    • @wallaceluna6241
      @wallaceluna6241 3 года назад +14

      I'm more interested in the fact someone hit that already. No one thought to put protection around it and also how long was that pipe line live and leaking before it got "Fixed" lol

    • @wutrbagz
      @wutrbagz 3 года назад +6

      Truth why put a med or high pressure riser street side let alone an gas fixture. All our meters are inside or on the front corner

    • @wallaceluna6241
      @wallaceluna6241 3 года назад +4

      @@wutrbagz Facts I don't needa education to see how bad this setup can go. Real quick. lol

  • @watomb
    @watomb 3 года назад +130

    Surprised the city didn’t make owner install guard post.

    • @josephaloise3380
      @josephaloise3380 3 года назад +11

      Definitely need some dead men around that meter. Couldn’t agree more.

    • @AlessioSangalli
      @AlessioSangalli 3 года назад +14

      Surprised the home owner did not install protection, independently of what a bunch of bureoucrats think people should do, and why Mr. Wakefield agreed to do the job without also putting in protection!

    • @LPJMagicmusic
      @LPJMagicmusic 3 года назад +12

      @@AlessioSangalli Roger easily could've recommended it and they refused but yeah let's blame him.

    • @AlessioSangalli
      @AlessioSangalli 3 года назад +8

      @@LPJMagicmusic I did not blame anybody, but it is also true that Mr. Wakefield did not address the evident lack of safety of the meter in this video, regardless to what the local authorities mandate in their jurisdiction.

    • @LPJMagicmusic
      @LPJMagicmusic 3 года назад +13

      @@AlessioSangalli he may not have addressed it to us but you have no idea whether he talked to the customer about it or not. My guess is It's not the plumbers job to install barriers, it's a plumbing channel so he doesn't need to tell you something obvious that you very intelligently noticed.

  • @billg4129
    @billg4129 3 года назад +48

    14:18 “where’d I put that damn thing” happens to me DAILY

    • @eliascastillo1641
      @eliascastillo1641 3 года назад +2

      I’m a machinist and I do that all the time only with me I’m walking around the shop for 10 minutes before I find it .

    • @kd5nrh
      @kd5nrh 3 года назад +1

      Find the tape measure...go look for the pencil...where's the damn drill...I know I got the impact gun out earlier...Fitbit thinks I'm walking marathons.

    • @OhSoTiredMan
      @OhSoTiredMan 3 года назад

      Me trying to find my screw bits

    • @naturalstatepoolandspallc338
      @naturalstatepoolandspallc338 3 года назад

      and then half the time its under your leg or literally right behind you. but i twist and search and all kinds of crap. i just had that thing! lol

  • @morphman86
    @morphman86 3 года назад +144

    I love how you're always talking about how important it is to turn the water off, no matter what, then go and do a live gas line replacement like this.

    • @60atk
      @60atk 3 года назад +39

      It may look and sound strange, but there's only about a 1/4 lb of pressure going through a residential main like this. JUST MAKE SURE NO ONE IS SMOKING LOL.

    • @davidreynolds731
      @davidreynolds731 3 года назад +17

      Even then you can put a match up to it and you will get a flame that can easily be put out by putting your hand over the pipe end

    • @morphman86
      @morphman86 3 года назад +6

      @@davidreynolds731 The issue is rather the carbon monoxide poisoning...

    • @CMDRZero01
      @CMDRZero01 3 года назад +14

      @@morphman86
      You only get CO poisoning from poorly burning gas. While you can do what he did since the pressure is around 7 inches wc or barely over 1/4 psi, it's better to just have the gas company come out and turn it off properly.

    • @morphman86
      @morphman86 3 года назад +4

      @@tcolondovich2996 Oh, sorry, I didn't know hydroCARBON gas didn't contain CARBON that would bind with OXYGEN when exposed to OXYGEN-rich air... Silly of me.

  • @osmanvincent1975
    @osmanvincent1975 3 года назад +26

    About 6 years ago, I was chasing a bunch of tiny leaks in 100 year old gas pipes. I called Oatey up, they recommended Hercules dope with kevlar fibers instead of their own name brand. At that time, I think they had recently purchased Hercules, so not quite like recommending their competitor. The kevlar makes the dope stiff, definitely does not flow like other dope. I ran taps and dies on the old threads to removed all the old dried junk before reassembly. I tested the old system at 100 psi for 3 days, no leaks.

    • @michaelwood2047
      @michaelwood2047 3 года назад +3

      Argco makes super dope, an anaerobic pipe dope. Its absolutely hell to undo. But for sketchy stuff you won't be able to get back to it is incredible

    • @youclogthemweclearthem2394
      @youclogthemweclearthem2394 2 года назад +1

      Gas lines work off of water column not psi. The system works on a max 5lbs psi.

  • @twizz420
    @twizz420 3 года назад +8

    It's refreshing to see someone who takes pride in their work for once. Going so far as to wipe the extra pipe dope off... I don't think I've ever seen that.

    • @TheOfficialStaxx
      @TheOfficialStaxx Год назад

      Plumbers that teach me would get mad and say that’s way too much. Just enough to cover where you plan on sinking the threads. It’s predictable enough and super clean. Just how I was taught. 🤷‍♂️

  • @chargers21203
    @chargers21203 3 года назад +5

    This is a man who truly loves what he does. He’s out here working when he really doesn’t have to, but he does to show us up and coming young guys how to do things the right way. Thank you for your videos sir.

  • @matys2933
    @matys2933 3 года назад +2

    I'm not even a plumber and this video is so enjoyable to watch. I enjoy your channel.

  • @mikeerin5031
    @mikeerin5031 3 года назад +7

    I have worked in offshore and onshore oil and gas industry. Offshore Teflon tape is prohibited for certain systems due to its uncanny ability to send little shards into the subsea directional control valves. Onshore, the pipe work is made up with hdpe tape (the blue stuff) and no pipe dope. Torque used is TAF...usually a roughneck with a cheater pipe on a 4ft pipe wrench. Never had issues.

  • @Ryan.Rivera
    @Ryan.Rivera 3 года назад +5

    Year 3 plumber here, love watching pros like you work. Always something that can be learned.

    • @charlespelletier9621
      @charlespelletier9621 3 года назад

      Yeah don't use tape on joints. Most states it's against code to use tape. Dope only and if.your worried about a joint use wicking. The moisture from the dope will make it swell and seal up the joint.

  • @boby115
    @boby115 4 года назад +7

    Roger, nice video but I'd like to go over some of the shortcomings I noticed, just to give the plumbers and pipefitters out there a perspective from the gas utility side and the National Fuel Gas Code. My name is Bob Yehlen and I've been a first responder /gas fitter for the gas utility in St Louis, Missouri for 35 years. I am presently retired but still consult for the gas industry from time to time when incidents occur throughout the country ( incidents like the over pressurized gas mains in Massachusetts, the mall gas explosion in Florida & ect.). So now let's go over the things I noticed on this particular video.
    #1 before making a repair to any fuel run let's determine if the original installation was up to past and present codes ( is the fuel run sized properly? What is the total gas load, house and pool heater? This particular meter set has a b-42 regulator and a 275 CFH (275,000 BTUs) gas meter on inchs delivery. So if the total load is over 275,000 BTUs, the gas utility should be contacted for a gas meter upgrade) #2 the pool heater fuel run came off the gas company pressure tap tee ( the gas company uses this tee to determine lock up and working gas pressures; this is not a tee for your pool heater fuel run), that being said you may use it as long as another tee is added. This is done very simply by replacing one of your elbow at the meter set with a tee & plug ( now a tap is available for the gas company to take pressures and you can also pressure test your underground fuel run using the same pressure tap tee, just by hooking up your manometer, turn the valve on and back off, now you have a pressure test going). #3 jumping a live fuel run is very old school & is no longer acceptable by the National Fuel Gas Code & the AGA ( American Gas Association). The proper procedure would be to turn the gas off at the meter, install your required fittings for the job and pressure test the complete system. I know it seems like a waste of time and opening you up to much more repairs if problems are indicated on the other fuel runs but that is what's required in this day and age ( believe me, there are a lot of law firms out there hoping you don't pressure test and bypass required procedures).#4 a ground joint union is not acceptable for underground fuel runs and risers ( only insulated unions are acceptable for underground fuel runs and risers, this is required for cathodic protection). #5 all underground fuel runs should have a trace wire or a means to locate the underground installation. Since this is a repair & the original installation had no means of locating the line, this should be noted on your receipt and your records.
    I hope some of this information was helpful. I know some of you will say that my local municipality or state does not require this,but these are the National Fuel Gas Codes, states and municipalities can enhance and make codes more stringent but in no way are they allowed to weaken or reduce the National Fuel Gas Code. You all stay safe out there and have a good day .

    • @joem5332
      @joem5332 4 года назад +2

      Finally some real knowledge thank you.

    • @wackyfours
      @wackyfours 3 года назад

      Hi, Bob. Do you have social media, website, RUclips channel, etc., where you explain the gas plumbing code and proper installation of gas fittings?

  • @Lithui
    @Lithui 3 года назад +8

    I spent my first 7 years as an adult working as an industrial tech in the fishing industry, one of the things I was shoehorned into as a young guy was plumbing and I don't even know how many miles of pipe I laid across the 4 plants I worked in, but it's nice to see someone else who does dope and tape for things like this. We were trained to do that for all gas lines, whether the gas was air, a combustible, or steam, and I can't think of any lines that I worked on that developed leaks (and with the relationships I have with my old chiefs, they would give me a lot of grief if they had to redo my work. 5 years out of the industry and I still get updates on projects I worked on)
    Please note, I am not a plumber. Welder, boiler tech, fabricator, and mechanic yes to some degree, but plumbing was just one of the jobs I got put on a lot between production runs to keep me on payroll.
    Keep up the good work Roger! I found you recently and have been directing customers who are struggling with plumbing to your channel!

  • @vernonyamada2200
    @vernonyamada2200 4 года назад +33

    There’s suppose to be a pressure test tee after the outlet on the meter and traffic protection

    • @benjamincain4778
      @benjamincain4778 3 года назад +2

      Gas company here requires an accessible tee on the outlet to “hot tank” the house line to work on the meter set. And certainly meter protection is a must.

    • @rubenalvarado9597
      @rubenalvarado9597 3 года назад +1

      @@benjamincain4778 The gas company is just gonna have to "wack'm" now to do any meter repair. Job security!

    • @Drewdayz2419
      @Drewdayz2419 3 года назад +1

      He got a union, good enough, usually atmos want a bypass place but they hung it without meter bar so.

    • @noeperez2816
      @noeperez2816 3 года назад

      We always have an inspector

  • @MatthewHouserMBA
    @MatthewHouserMBA 3 года назад +5

    If you want your dies to stay sharp on that threader, you need to back up a quarter turn every full rotation to break the chipping from the cutter threads. This is common when threading almost any hard material.

  • @johnpineda9985
    @johnpineda9985 3 года назад +5

    Key point “always back up your fittings with another pipe wrench before fully tightening your pipe so that the prior fitting or pipe does not spin on you causing a leak.

  • @TinoRobinson80
    @TinoRobinson80 3 года назад +5

    I’ve never been interested in plumbing until watching your videos, thank you 🙏🏾 .... am i getting old?

    • @daanwilmer
      @daanwilmer 3 года назад

      I don't think it's age, but rather the way Roger explains things. He knows his things and explains them well, without overselling (or underselling) his craft. That is what makes these videos compelling (at least to me).

  • @combat514
    @combat514 3 года назад +2

    The amount of respect I have for you not just doing it to spec but doing it so It doesn’t leak again (you don’t have to do it again) is amazing,
    Love the content

  • @randykopis8070
    @randykopis8070 3 года назад +3

    I love your videos! Im not a plumber, but im learning a lot!
    My favorite tool is the M18 Fuel deep cut Portable Bandsaw! I've been building fences for over a decade, and this tool can handle a lot of what the portacable corded bandsaw can.
    For volume, a battery will always fall short of what a corded tool can accomplish, but cut for cut, it always does a great job!! Its spectacular for small jobs, with less than an hour of consecutive cutting. More than that, i just use another battery.
    If i had to give up every fence tool I own, the tool I would trade my left foot to keep, would be my milwaukee bandsaw.
    It cuts anything I imagine a plumber would need to cut, if you've got the space to do it!!
    I've cut aluminum, stainless, galvanized steel, carbon, hardened steel, copper, pvc, plastic, wood 4x4s, and a block of 2" by 2" solid square stock.
    Just don't cut rusty stuff. That eats up the blade. The tool doesn't care, but the blades do.
    Highly recommend, 20/10 stars.

    • @joshdiehl8737
      @joshdiehl8737 Год назад

      What would be the benefit over a sawzall? Straighter cuts?

  • @guitar1301
    @guitar1301 4 года назад +13

    In New Jersey Teflon tape is not allowed on gas piping unless it is the yellow tape That's rated for gas. If it was hit by a car it also requires a pressure test and inspection. So that you can check if line underneath ground is damaged in any way

    • @timgraham7851
      @timgraham7851 4 года назад +3

      Plus, protective posts should be installed.

    • @jamesallen3739
      @jamesallen3739 4 года назад +1

      The blue monster is also rated for gas piping.

    • @guitar1301
      @guitar1301 4 года назад +2

      @@jamesallen3739 Blue Monster "Gas Guard" yellow tape is the only Blue Monster tape approved as per International Fuel and Gas Code.. But I guess local jurisdictions have final say.....

    • @boby115
      @boby115 4 года назад +1

      @@guitar1301 , you are correct, even though the Blue Monster blue tape can meet the standards for gas, once it's installed we have no idea. That is why Yellow Tape is required by the National Fuel Gas Code and The American Gas Association. Local codes maybe more stringent and strict but in no way can they weaken The National Fuel Gas Code.

    • @joem5332
      @joem5332 4 года назад +1

      Bob Y bingo you’re correct. Wrapping 7 times is a bit excessive?

  • @actsofserviceplumbing90
    @actsofserviceplumbing90 3 года назад +1

    I have been plumbing 30+ years and always enjoying watching your videos. I’m never too old to learn something new!

  • @brianrobertson1211
    @brianrobertson1211 3 года назад +2

    I've gone to plenty of callbacks on leaks where plumbers didn't use both teflon tape and pipe dope. I've also worked on gas lines on the fly. Good work!

  • @jamesscoggins8373
    @jamesscoggins8373 4 года назад +21

    The best plumber back at it much love.

  • @dienekes4364
    @dienekes4364 3 года назад +5

    The water line into my house broke when I tried to replace the shutoff valve (26-year-old double-wide trailer that had been empty for 7 years) and I tried to thread the galvanized pipe coming out of the ground. My brother-in-law has a manual threader that worked okay, but I would have LOVED to have that tool. It probably wouldn't have split the line down into the ground and broke the pipe off at the elbow if I had. On the other hand, even though I had to dig up that whole section and replace it, at least I know it's got a brand new line all the way from the PVC water supply from the meter.
    I'm slowly replacing all the Poly water lines in the house with PEX. I need to get a tool that crimps rings with 1 hand. I just don't trust Sharkbites. I'll use them if it's in a place where I just can't get my crimping tool but, to me, I'd rather save the money and put a little more effort into the connections. I've seen the tests with pressurized water and I know the pressure fittings work fine, but I guess I'm just too old school (and too cheap).

  • @rayhightower2654
    @rayhightower2654 3 года назад +2

    I have many memories (and shoulder aches) from carrying and using an ancient ridgid 700 threader. Outside of the weight of it, seeing the new shiny threads on galvanized or black pipe was always satisfying. Enjoyed the ride-along! Keep up the good work!

  • @WillC
    @WillC 3 года назад +1

    I love seeing Roger on the job!!!! like a boss.

  • @danieldawson222
    @danieldawson222 4 года назад +5

    What I like about your work is that you are fast efficient,and don't get
    Any on you!

    • @joem5332
      @joem5332 4 года назад +2

      Fast Christ that was A 5 minute job. Wrapping 7 times with Teflon completely covered the threads plus some pipe. Got oil all over the cement. I would have ripped my guys a new one threading with nothing under to catch oil. Should tell home owner a bollard needs to be installed to protect meter from being hit by cars

    • @Rihardololz
      @Rihardololz Год назад

      @@joem5332 Guys like you, the conceal carry is a thing.

  • @tymcconvey1919
    @tymcconvey1919 3 года назад +14

    no back wrench on the union! can see everything spin

  • @SC-sz9ms
    @SC-sz9ms 3 года назад

    this is great. I really appreciate you taking the time to make these videos! Thank you so much!

  • @dakotarouse1766
    @dakotarouse1766 3 года назад

    Seeing master tradesmen tricks and tips is always amazing I'm blow away by how effective rodger is at this.

  • @Havoc080
    @Havoc080 3 года назад +5

    When we have Gas risers in Canada, we require a minimum of 4 90's on the riser to create a swing joint so if the ground has a frost heave it dosent break the line.

    • @joea5183
      @joea5183 3 года назад

      Hes in texas...

    • @Havoc080
      @Havoc080 3 года назад

      @@joea5183 Sure, but earth movement can still occur can it not? I've also seen a gas line get backed into and not break because of a swing joint. I was more so curious about his local code.

    • @randomman057
      @randomman057 3 года назад +1

      @@Havoc080 Most of texas is very shallow top soil with limestone beneath it. Texas soil doesn't really tend to move.

    • @rogertycholiz2218
      @rogertycholiz2218 3 года назад

      C H - Here in The Great White North we do not do the same as they do in the USA.

  • @jakeschroeder1553
    @jakeschroeder1553 3 года назад +49

    Hack: Doesn't turn the gas off or care.
    Novice: Turns the gas off to be safe.
    Pro: Knows the correct way to do it without having to shut off the gas.

    • @joshcowart2446
      @joshcowart2446 3 года назад +3

      I’m sort of a mix between the first and the last. If I need to put one fitting on a live gas line, I’ll do it without shutting off the gas. However I don’t bother trying to cover up the pipe or anything like that. I just get everything ready then screw the piece out and put the other one in. If some gas goes into the air, oh well.

    • @cillersbadass7590
      @cillersbadass7590 3 года назад +2

      I hope there is NEVER anything gonna happen if you leave on the gas line,
      Cause no insurance will pay...
      I mean why would you rather turn it off most of the time there is no one at home. I think to be safe is more important than not need to turn off the gas.

    • @joshcowart2446
      @joshcowart2446 3 года назад +2

      Cillers badass if you know what you’re doing there’s no risk. It’s not as big of a deal nowadays with all the electronic ignitions. However at one time, if you turned the gas off it cost you an hour or more to relight all the pilots in the house. Therefore if you had to make one connection it saved the customer to work on it without killing the gas.

    • @TheBayru
      @TheBayru 3 года назад +2

      How do you pressure test the new joints for leaks without turning off the gass or isn't pressure testing an installation a requirement in Texas? Also "it's okay 'cause I don't smoke" seems a rather deceptive statement with cars driving by at a few feet from the open pipe. I must be missing something here.

    • @cillersbadass7590
      @cillersbadass7590 3 года назад +2

      @@TheBayru seems like you love your own life a bit to much 😂
      Never had a near death moment?

  • @shaunjakeway6856
    @shaunjakeway6856 3 года назад +1

    Hey Roger, its Shaun again. We've had a comment conversation before over another of your videos. Im a plumber and licenced gasfitter here in Saskatchewan, Canada. Again, great video. Its crazy to see the differences in gas code from place to place. Here in Saskatchewan, you'll never see a meter hung like that. Our meters are either mounted to the house , or we have what we call trailer stands, which, if a meter cannot be bolted to a fixed-foundation house, are used. They sit at about 4' above ground. Few other things, we aren't allowed the use of galvanized piping for anything in plumbing, other than rural waterlines. Everything i do gets painted grey, or yellow in a commercial application. A lot of cheap guys in town here just leave the black Iron to rust, which looks like absolute garbage.
    We have to have riser sleeves around any gas riser coming out of the ground, with 14gauge tracer wire, and 4-elbow, 10" center to center swing joints. Its crazy for me to see that piping out of the ground with no swing joint!
    As for the "teflon" and dope....i was trained with just dope. My journeyman was old school and it wasn't until I was doing a 12 unit condo building in my third year of apprenticeship that I requested "teflon". Our tape for gas is yellow and its a PTFE thread tape. But yeah, tape the threads and then dope. Doesn't matter if it's gas or water. Always tape then dope. Its a different feel than just dope.
    Last thing to harass ya about is the m18 threader. It only became available last year and ive been toying with notion of purchasing one. I've always lugged around my ridgid 300, and I have an auto-oiler at my shop. The only hand threader that I have is the ratchet style hand lever, which has been good for taking out on location for small works. Im going to assume that youd recommend it? Haha

    • @RogerWakefield
      @RogerWakefield  3 года назад +2

      Thanks again Shaun. Around here this is the normal. There are a million things that I think should be done in all of plumbing but if I did all of them and nobody else was I would be going out of business. I started using tape and dope when one of the smartest engineers I ever met told me that was the way he wanted it done. You're right, I really like the M18. I've used the 300 for a long time and the ratchet threaders have been in my vans forever. BTW, We quit using galvanized for waterlines many years ago.

  • @abdulelkhatib2674
    @abdulelkhatib2674 3 года назад +1

    Roger is that really cool uncle who can always do the job no matter what that we all wish we had

  • @boomer2131
    @boomer2131 3 года назад +25

    You HAVE to consistently put oil as your threading please do this people

    • @joshcowart2446
      @joshcowart2446 3 года назад +4

      I though that as well. I think the only reason he was doing it that way is he was by himself and trying to catch the oil in the rag. I guess it’s fine if you don’t mind replacing teeth once a year.

    • @Germ1993
      @Germ1993 3 года назад +4

      Its only hurting his teeth, but yeah oil almost constantly is correct

  • @stevenbrown5693
    @stevenbrown5693 3 года назад +3

    Roger , try the pipe treading lube that Ridgid sells. It comes in a spray can and it works great without the mess you get from cutting oil. Our threads come out beautiful with it.

  • @troycorsi4526
    @troycorsi4526 2 года назад +1

    Wow absolutely phenomenal work. You're hired in my book!!! Professional, somebody that knows exactly what they're doing.

  • @jerryofalltrades1653
    @jerryofalltrades1653 3 года назад +3

    It’s funny I’ve had my workers talk smack to me because of me using pipe dope and Teflon tape at the same time but that’s the way I got taught as well and I have never had a gas line leak so it’s good to hear other veterans in the world doing it as well thank you for letting us know and I enjoy your videos I don’t know how I came across them but I really do enjoy your videos

  • @AnonMemSoc
    @AnonMemSoc 4 года назад +9

    Looks good hoss

  • @pmag3200
    @pmag3200 3 года назад +4

    I had to plumb a whole Factory which was stainless steel piping and fittings and you learn real quick that you put your pipe dope on your threads first and then put your tape over top and then tighten down and you have no leaks and it's clean

    • @tylerdelancey9543
      @tylerdelancey9543 3 года назад +1

      The company I work for we do a lot of commercial pipefitting including stainless work and they do the exact same thing. However, we utilize other materials in aspects of pipefitting and I believe the process you described
      is only correct for stainless work otherwise, teflon tape should be applied (correctly) first THEN pipe dope. But hey everywhere is so crazy and different as long as it had pressure or doesn't leak isn't that all that matters

    • @pmag3200
      @pmag3200 3 года назад

      @@tylerdelancey9543 cool...yeah which way you use and works with no leaks...all good..🍺😎

  • @wintonhudelson2252
    @wintonhudelson2252 3 года назад +2

    We do liquid and high pressure vapor propane piping. Yes, we always use tape and dope. We're mostly using Sch. 80 A53 grade B with SA105N forged steel fittings. The TRC is real specific on some of the points in NFPA 58.

  • @zombieater6663
    @zombieater6663 3 года назад

    Its so awsome to see someone with decades of experience work their trade. This is a master at work.

  • @truckingwithangel1174
    @truckingwithangel1174 4 года назад +7

    With small size pipes it may work fine, but from my experience on a job with 3 inch galvanize pipe I got leaks in almost every fitting and had to do it again with paste only.

    • @centralcoastcamper9631
      @centralcoastcamper9631 3 года назад

      On 2-1/2" and larger pipe Keytite or Grip pipe dope is the way to go.

    • @cannonplumbinganddrainllc4221
      @cannonplumbinganddrainllc4221 3 года назад

      I don't understand how ? Teflon and pipe dope is the way to go on every size, just saying ive never had a problem

    • @fdgdgdbd
      @fdgdgdbd 3 года назад

      thats insane, here once you hit 2 1/2" and above pipe you need to make Welded connections......

  • @Mike-mn9xo
    @Mike-mn9xo 3 года назад +5

    I work for a gas utility company in the northeast . It blows my mind that gas meters are in the front yard... ours is in the basement or on side of house .

    • @somethingelsehere8089
      @somethingelsehere8089 3 года назад

      I think that is an alley behind the houses.

    • @wutrbagz
      @wutrbagz 3 года назад

      Where at I’m baltimore and ours are inside or the front corner

    • @Mike-mn9xo
      @Mike-mn9xo 3 года назад

      @@wutrbagz New England

    • @wutrbagz
      @wutrbagz 3 года назад

      @@Mike-mn9xo very cool! Safe operating!

    • @Drewdayz2419
      @Drewdayz2419 3 года назад

      Where is the riser ,out or in, and cause it blows my mind see in under or in house with the reg,

  • @marionoliver6004
    @marionoliver6004 4 года назад

    I really enjoy and appreciate your videos. Very informative. Keep them coming

  • @sparkplug1018
    @sparkplug1018 3 года назад +1

    Love their M18 impacts, the 3/8, 1/2 impact wrenches and 1/4 impact driver. Working on cars they're pretty nice, their reciprocating saw is pretty good too.

  • @tylers6460
    @tylers6460 3 года назад +11

    I gotta say, I'm REALLY digging the background jam you chose for this video.
    I was vibin' the whole way through.
    Thanks man!

    • @echothehusky
      @echothehusky 3 года назад +1

      I was thinking that! 10/10!

  • @jackstraw5527
    @jackstraw5527 3 года назад +26

    No kidding they hit it with a car, terrible spot to have the meter.

  • @leeaudio027
    @leeaudio027 3 года назад

    Love the trades, much respect and love your narrated videos thank you for sharing your skills

  • @50srefugee
    @50srefugee 3 года назад

    DYI here. Nice to watch the pros at work.
    Chatter about opening the gas pipe under pressure--I watched the gas company guy replace the regulator at my folks house--they needed larger service for a spa heater and a new gas stove. And part of that job was replacing the valve on the service side of the regulator. indeed there was a moment where the gas just flowed--but only a moment, because he too had everything lined up and ready to go. I seem to remember this clever little rig that plugged the service pipe with a expandable stopper that, unexpanded, could be pushed through the open valve, and a rod that came up through the bleed valve? Sorry, this was years ago, I don't quite remember how it all worked.
    One thing I do remember, brought to mind by all the rust visible here, was a couple of coats of that gray anti-corrosion paint you can see on the meter.
    Did the riser going to the pool heater eventually get painted?
    Finally: I remember once slipping a section of PVC over a gas riser (house side of the regulator, valve off) to protect the riser from weed-cutter line, which had over the years eaten almost all the way through the riser (that was why I was replacing it). Is there a reason why you didn't do that here? Was I wrong to have done it? (Yeah, looking back, should have called a pro for that job. But I was a young and foolish know it all, and I at least read up pretty thoroughly on working with gas, so I wasn't working blind. Harris County, TX, jurisdiction.)

  • @Eclipse-go2fl
    @Eclipse-go2fl 3 года назад +48

    I just can’t believe there is nothing blocking the gas meter from traffic.

    • @mike_minnick
      @mike_minnick 3 года назад +1

      Yeah, seems like the worst possible location for it

    • @littlepastelkitten
      @littlepastelkitten 3 года назад +3

      that's america for you

    • @Z-Ack
      @Z-Ack 3 года назад

      I was mowing a big 4 acre field one time.. was hired by a dude and all he said was “i want it bailed for the horses.. the stuff was weeds galore about 4 foot tall:. Right smack im the middle of the field was a damn gas line check with the 2 foor pipe that sticks outta the ground that says no smoking.. well i ran that thing over. Got lucky and didnt blow my ass off but i didnt even noticezc i thought it was like a rock or possum or something until i go to roll the bail off and see the white pole in the bail... so i drove up to ole buddy and told him to call the gas company and i just left. Never talked to him again.. lol

    • @alexpuffinburger9015
      @alexpuffinburger9015 3 года назад

      Its actually quite illegal to not have bollards near a gas meter when its a certain distance away from anywhere a car could reasonably be.

    • @Theinatoriinator
      @Theinatoriinator 3 года назад

      ​@@alexpuffinburger9015 the dialogue must've been. Well cars reasonabley wont be on a road! that's why we have roads right? its not like anyone's ever going to be regularly driving down a road!

  • @y2kxj
    @y2kxj 3 года назад +30

    There is a pro move there, wipeing the extra pipe poop off the pipes..

  • @bigfunkman6876
    @bigfunkman6876 3 года назад +1

    Pro-tip: i use pipe thread sealant on pipe threads, then teflon tape. this leaves your fingers clean, and the pipe dope enters the joint as you tighten the fitting through the tape:
    Love the vids roger!

  • @warriorz_hammer_7743
    @warriorz_hammer_7743 3 года назад +1

    Loving you're videos so far man keep up the amazing work and thank you for sharing you're work with us, I think it's dangerous because they didn't have anything surrounding the metering box or pipes as if something hits it and sparks and the gas leaks it could lead to an explosion causing big damage evan a fatality considering one of his neighbour has already hit it once, I hope he atleast put a box around it in the end for his safety and the safety of others evan a steal box or thick poles in the ground to stop it in future, as always stay safe and take care out there man💪!!!

  • @toddavis8603
    @toddavis8603 3 года назад +3

    Please add 4" steel posts, nearby, to protect gas installation in the future.

  • @unknownvalor9755
    @unknownvalor9755 3 года назад +3

    Wow, checkout the gas pipes for the neighbor at around 16:50 . checkout the angles of the back 2 pipes!

  • @mabbaticchio
    @mabbaticchio 3 года назад

    I am an IT Network Administrator. Why am I watching your videos non-stop? Glad I found your channel. Oh, and that is a bad-ass watch you wear. What is it?

  • @TheBigstve
    @TheBigstve 3 года назад +1

    Brilliant work Roger. Came across your video in suggestion 👍. All way from England, Manchester.

  • @theomegablade6415
    @theomegablade6415 3 года назад +11

    Seems like a massive safely hazzard to have an exposed gas mains next to a road with 0 protection around it, hell put a crappy picket fence around it at least!

    • @kidvinkly2771
      @kidvinkly2771 3 года назад

      his surroundings are clear, im sure if there was any cause of danger he would know of it, considering he is properly certified and has decades of experience like working for texas instruments. it was open for literally .5 seconds

    • @theomegablade6415
      @theomegablade6415 3 года назад +3

      @@kidvinkly2771 i'm not talking about the job, i'm talking about an exposed gas line near a road with no *fence* or anything to stop a car hitting it

    • @ScaredDonut
      @ScaredDonut 3 года назад

      @@theomegablade6415 Welcome to North America 😂

    • @theomegablade6415
      @theomegablade6415 3 года назад

      @@ScaredDonut i live in the UK, i fear what america is like

    • @ScaredDonut
      @ScaredDonut 3 года назад

      @@theomegablade6415 My city has a few near major roadways (80KM/H is the speed limit on those) Wouldn't be a good day if a car hits it

  • @Healthy_Horseman
    @Healthy_Horseman 2 года назад +1

    I love hearing these little tricks of the trade like the pipe dope and Teflon, never seen that before and my cousin is a plumber. Really good job btw, now just need some protection from passing cars.

  • @godspeed4567
    @godspeed4567 3 года назад

    Because of your videos my respect for a good plumber has gone up dramatically so keep up the good work

  • @ericsanchez2121
    @ericsanchez2121 3 года назад +12

    Please don’t add much pipe dope to the beginning threads, you’d be surprised how many gas valves get clogged from pipe dope and had to be replaced 🤦🏽‍♂️

    • @chrisd3399
      @chrisd3399 3 года назад +3

      corey Babcock wrong as long as you know what you’re doing. I’m sure it’s happened once and you say they get clogged lol not a common problem

    • @rupe53
      @rupe53 3 года назад +6

      @@chrisd3399 ... I do a LOT of generator work and you'd be amazed at how often I find pipe dope in the works within the gen set when it doesn't start on the first try after an install. I won't say it's often but once a year (in my 25 years) is often enough to know where to place the blame. In cases where I needed to check pressure on an older install and there was no test fitting I have used the sediment leg, where I also run into some goo balls left over from the original installation. Just saying it's more common that you think, even if they never actually cause a problem.

  • @m.koehler7716
    @m.koehler7716 3 года назад +5

    Where I’m from local code enforcement will fail us for using Teflon on gas connections, must be pipe dope only.

    • @Republic1usa
      @Republic1usa 3 года назад

      RE code book closely ," dope must be applied to male threads", what you put on above and beyond up to craftsman.

    • @m.koehler7716
      @m.koehler7716 3 года назад

      @@Republic1usa but it’s up to local enforcement and they will fail inspection here if we use anything but dope.

    • @tipperzack
      @tipperzack 3 года назад

      @@m.koehler7716 What state?

    • @m.koehler7716
      @m.koehler7716 3 года назад

      @@tipperzack Maryland

  • @zoubeirfaouzi149
    @zoubeirfaouzi149 3 месяца назад

    What a vibe. Enjoyed this, thanks sir.

  • @ryanknuth6915
    @ryanknuth6915 3 года назад +2

    Great video! Here is PA we always spray paint pipe and would use meter protecting in that location...I know all about dragging the old ridgid threader out of the back of the truck haha

    • @tomallen7699
      @tomallen7699 3 года назад

      We always paint our pipe as well- nice finished product, keeps pipe from rusting also!

    • @rupe53
      @rupe53 3 года назад

      @@tomallen7699 ... in these parts (Ct) the rule is all black pipe must be painted or it doesn't pass inspection. Not sure if that's on the books, but that's what the inspectors want, and it can't hurt.

  • @mattheweustis9506
    @mattheweustis9506 3 года назад +3

    Look out for mechanical contractors that use a lot of Teflon tap....

  • @StinyGinkle
    @StinyGinkle 3 года назад +5

    Too much teflon gives you a false sense of the fitting being tight. Well the amount you put on there anyways.

    • @scott19087
      @scott19087 3 года назад +1

      6 times round is the sweet spot though.

  • @patrickguarracino3174
    @patrickguarracino3174 3 года назад

    It’s nice with domestic fittings, pipe make up is always the same as long as dies are set correctly an threading length are the same, good job Roger!!!

  • @centralcoastcamper9631
    @centralcoastcamper9631 3 года назад +2

    40 years ago an old journeyman showed me the teflon tape and pipe dope trick. He pointed out the Taiwan pipe and fittings and lack of quality control as the main reason for doing so. The other advice was to use galvanized fittings for gas lines to avoid sand holes that the black foreign fittings sometimes had.

    • @MrDmadness
      @MrDmadness 3 года назад

      If you use galvanized fittings for gas you've done so illegally. ( in most places ) also you've joined dis similar metals as galvanized fittings contain zinc which is more noble than black iron, so you INCREASE the chances for pinhole leaking due to electrolysis. In short, you got taught wrong

  • @brianrobertson1211
    @brianrobertson1211 3 года назад +3

    That black iron on the riser is exposed to weather. It probably should be painted.

    • @spencerhanson3112
      @spencerhanson3112 3 года назад +2

      It’ll be alright

    • @warriorz_hammer_7743
      @warriorz_hammer_7743 3 года назад

      @@spencerhanson3112 untill it rusts out and leaks yeahh just hope no smoker walks past as it does and hope for no sparks when it rusts out or they'll have a bad explosive time 😅

    • @richardjoseph8683
      @richardjoseph8683 3 года назад

      Seems to me codes are lacking down in Texas. In New Jersey teflon tape is not permitted on gas pipe & all exterior gas piping must be painted with rust proof paint not to mention pressure tested

    • @joshuapittman5208
      @joshuapittman5208 3 года назад

      @@richardjoseph8683 Id like to imagine he did a leak test inside the house at an appliance, much easier. Kinda silly that NJ doesn't allow tape.

    • @richardjoseph8683
      @richardjoseph8683 3 года назад

      @@joshuapittman5208 It was a dedicated line to the pool heater so therefore couldn't be tested from a house appliance.

  • @mattheweustis9506
    @mattheweustis9506 3 года назад +3

    I never use any tape on any gas line connection and actually illegal in my state. For a number of reasons number one why I don’t use it is because while threading steel pipe your dies teeth wear down... gotta replace them. Instead of replacing them let’s add tap. Fresh cut pipe threads should screw to the female end idk 2 turns if even. With new pipe die. A lot of mechanical contractors when it comes to gas lines they use a lot of tape ... to rebuild the thread up for there blown out die...

  • @Aaron_R
    @Aaron_R 4 года назад +1

    Propress RP 340, favorite tool

  • @mrmagdump9085
    @mrmagdump9085 3 года назад

    My boss always had me do teflon and then dope as well, never really thought of doin it any diff as that was my first job doing mainly pipework

  • @gordonretherford5451
    @gordonretherford5451 4 года назад +5

    No tape ever on gas!

    • @shaunjakeway6856
      @shaunjakeway6856 3 года назад

      Why not?

    • @shaunjakeway6856
      @shaunjakeway6856 3 года назад

      They call for tape, or dope on gas piping here. Only time you wouldnt would be on flared copper.

  • @kellymurphystl
    @kellymurphystl 3 года назад

    Discovered your videos today - absolutely love them. Thank you for taking the time to make these and share them with the world. I have to say, though, I really dislike the repetitive background music. I keep hearing "yeah" in the back of my head and it distracts from an otherwise excellent video.

  • @tunafish3216
    @tunafish3216 3 года назад +1

    Wow that’s a great Milwaukee Pipe Threader.
    Great video.

  • @Martin4Mary4Ever
    @Martin4Mary4Ever 2 года назад

    Man, you make plumbing look good in this video.
    Smooth, sleek, and clean!

  • @MrMaxCenturion
    @MrMaxCenturion 4 года назад

    M18 Fuel Hackzall
    M18 Fuel Hammer Drill and the
    M18 Fuel Impact Driver
    I love these. They've made my plumbing jobs go so much more easily and boosted my productivity.

  • @jonhdoe9623
    @jonhdoe9623 3 года назад

    What do I think....how to say this without coming off weird ... A.) I could watch you work all day. I love how you work. You already had every step planned and ready. Then did the job flawlessly. B.) I wish you were my boss. I swear dude....there needs to be more ppl like you in this world. No bullshit or else....but ready to teach and show in the kindest, most patient way. C.) I wish you had been my dad lol. Your personality is so much like the coolest dad ever. Patient. Kind. I've never heard you cuss .... Doubt you yell very often. Bet you've never hit someone because you had lost your temper. Bro. Keep being you. I wish there was more folks like you. God bless.

  • @randomuzer266
    @randomuzer266 2 года назад

    I’m having to do a similar job in a couple of days, I’m new to it (I’m an apprentice, but eventually gonna try and become a plumber some day), so thank you for this!

  • @fabianalmaraz7319
    @fabianalmaraz7319 3 года назад

    Clean job Roger. I would recommend adding a layer of paint over pipe. Keeps rust away and makes job look alot cleaner👨‍🔧

  • @robertjollay4902
    @robertjollay4902 3 года назад +1

    Another great job... Rodger, I also use Teflon tape and pipe dope together on pcvp female threat fittings to connect male brass threads on shower valves... I only go hand tight, but never had a leak doing it that way... Thank you again,,,,

  • @IHateTheVA
    @IHateTheVA 3 года назад

    I care nothing for plumbing but i cant stop watching all your videos, impressive.

  • @MojoPup
    @MojoPup 3 года назад +1

    I don't feel so bad now about the pipe thread/pipe dope method, thanks! I've had folks snicker at me for "overdoing it". When it comes to gas, I don't take any chances.

  • @dmoneyusa2851
    @dmoneyusa2851 3 года назад

    I just learned something new. Thank you. 👍

  • @zousssnotzeus5341
    @zousssnotzeus5341 3 года назад

    this man is such a dad. 14:20 i could feel him wanting to say "aw damn whered i put it"

  • @mattp3471
    @mattp3471 3 года назад

    Love the instrumental hip-hop that’s in a lot of your videos! Very tasteful music.

  • @ronaldbrown5796
    @ronaldbrown5796 3 года назад +1

    what a great video. answered alot of questions. To bad I'm too old to start a plumbing career.

    • @RogerWakefield
      @RogerWakefield  3 года назад +1

      Glad you enjoyed it! Nobody is too old if you really want to.

    • @ronaldbrown5796
      @ronaldbrown5796 3 года назад

      Looking forward to your next video. Keep them simple and well explained
      Enjoy your day!!

  • @Loucas
    @Loucas 4 года назад +1

    Great video! great work

  • @downstream1152
    @downstream1152 3 года назад

    I always use a backup on the union to tighten. I appreciate the nice clean square job.

  • @diegovasquez4001
    @diegovasquez4001 4 года назад

    Sick video roger ! Always work on gas lines. If there’s a lot to do I would cut off gas of the house to just be safe.. I’ve never used that tool, nor have I made threading on galv pipe.. Have mega/propress tool. So I’ll slap a male adapter on the other side..

    • @diegovasquez4001
      @diegovasquez4001 4 года назад

      I’ll never do that working on a meter though.. only on a new extended gas line.. to whatever needs a new gas line ran too..

  • @jessehaefele2289
    @jessehaefele2289 3 года назад

    Agreed. I have always taped and doped, just the way I was taught. Only thing I didn't like was no back up wrench!

  • @adrianlagunas3993
    @adrianlagunas3993 2 года назад

    its 2:23, and im up watching plumbing videos. thank you for showing me this

  • @ofgb1975
    @ofgb1975 3 года назад +1

    First class job... My respects...

  • @zacharybinette9103
    @zacharybinette9103 3 года назад

    I’ve always done that on water never thought I needed it with gas good tip

  • @shaundonovan2193
    @shaundonovan2193 3 года назад

    Nice clean and neat job. I agree, Teflon and Pipe Dope on all jobs.

  • @waynecurr9569
    @waynecurr9569 3 года назад

    Teflon and dope is the best method . Key tight works great ( just messy ) . Kinda surprised you didn't use galvanized pipe and fittings . That tool and Milwaukee tools in general are awesome !