Samsung A53 with restart issue repaired

Поделиться
HTML-код
  • Опубликовано: 22 ноя 2024

Комментарии • 6

  • @vlogwithjahid9847
    @vlogwithjahid9847 11 дней назад

    আপনার কাজ ভালো

  • @MohamedAdel-sy2cb
    @MohamedAdel-sy2cb 11 дней назад

    👏👏

  • @taufikanwar7595
    @taufikanwar7595 11 дней назад

    BROTHER SMD ? And heat and also alir

    • @VDD_MainRepairs
      @VDD_MainRepairs  11 дней назад +1

      sorry i didn't fully understand your question but i guess you are asking about my hot air station settings if so i hope you find the following answer helpful for you
      It depends on your hot air station , and what you are doing
      As an example my hot air station is quick 861dw , if i will use it to remove the glue.i will set the temperature to 270 and the air at 60% , if i will use it to desolder a cpu i will start by 270 heat and 60% air then i will shift to 380 heat and 60% air and the last stage i will raise the temperature to 400 to remove the cpu without the risk of ripping pads
      It really depends on what works the best for you , you need to try and error till you reach the optimal settings that work the best for you

  • @gulbilal706
    @gulbilal706 День назад

    what flux paste do you use

    • @VDD_MainRepairs
      @VDD_MainRepairs  23 часа назад

      I'm using Amoe m50-10cc syringe flux , it does the required job , has to smell , isn't expensive and easy to clean .