𝙏𝙝𝙮𝙧𝙞𝙨𝙩𝙤𝙧 𝙤𝙧 𝙎𝘾𝙍 𝙏𝙚𝙨𝙩𝙞𝙣𝙜 𝙋𝙧𝙤𝙘𝙚𝙙𝙪𝙧𝙚 | Procedure to Test the Thyristor with the help of Multimeter

Поделиться
HTML-код
  • Опубликовано: 20 дек 2024

Комментарии • 57

  • @saikatbanerjee1973
    @saikatbanerjee1973 11 месяцев назад +2

    Kindly reduce that background music so that we can hear clearly

  • @willykristanto9957
    @willykristanto9957 2 года назад +4

    Of course it will connect, because you connected the gate (which has only few ohm to cathode) to anode

    • @FlowChart
      @FlowChart  2 года назад

      It’s just a testing way. Youbcan test in another way also.

    • @Ivanaet
      @Ivanaet Год назад

      The connection between the two probes are closed via the gate, doesn't proof anything

    • @ctphilippi
      @ctphilippi Год назад

      Indeed, I believe it should remain conducting after the gate is disconnected from anode, right? That is not happening here.

  • @ravirusty348
    @ravirusty348 2 года назад +3

    Pls upload some more videos about thyristor rectifier

  • @allennhamomaweni2176
    @allennhamomaweni2176 5 месяцев назад +1

    So if I get a resistance of 0.0001 ohm on continuity test (your first test) does it mean the thyristor is faulty?

  • @vinamghimire
    @vinamghimire Год назад

    excellent. thanks for easy procedure

  • @amosolalekan3740
    @amosolalekan3740 Год назад +1

    How will I determine the bad scr

  • @davidshanahan3693
    @davidshanahan3693 2 года назад

    A very good demonstration.

  • @knowbody9679
    @knowbody9679 2 года назад +1

    This is extremely helpful. Thank you so much. I don’t know how you determined the gate pin though.

  • @devilvortex1
    @devilvortex1 Год назад

    hi! I have scr but there no datasheet. How I can find which one is the gate terminal?

    • @FlowChart
      @FlowChart  8 дней назад

      Measure as per diagram

  • @sokdolla
    @sokdolla Месяц назад

    Is it for convert AC to DC right?

    • @FlowChart
      @FlowChart  Месяц назад

      Yes

    • @sokdolla
      @sokdolla Месяц назад

      @FlowChart how to wiring AC input and DC output? I see only one AC input

    • @sokdolla
      @sokdolla Месяц назад

      @@FlowChart ??????

    • @FlowChart
      @FlowChart  Месяц назад

      This type 3 pcs used for making 3 phase SCR or converter. Please check drawing.

    • @sokdolla
      @sokdolla Месяц назад

      @@FlowChart we output DC- and AC neutral together?

  • @John-qr4kf
    @John-qr4kf 4 месяца назад

    Thanks ❤ 👍🏽

  • @deepakpareya170
    @deepakpareya170 2 года назад

    What does happen when we check in reverse bias ..

  • @bagavathisp9694
    @bagavathisp9694 Год назад

    Good

  • @avinpais
    @avinpais Год назад

    Where can i buy this thyrister?

  • @ravirusty348
    @ravirusty348 2 года назад +1

    Sanrex rex product upload some more videos

  • @ravirusty348
    @ravirusty348 2 года назад

    Thank you very much

    • @FlowChart
      @FlowChart  2 года назад

      Welcome, share the video and stay with Flow Chart

  • @dentech6865
    @dentech6865 Месяц назад

  • @davefrancis4499
    @davefrancis4499 7 месяцев назад +1

    This is not correct. You can’t use the multimeter diode voltage the power tue gate. All you’re doing is testing the gate to cathode. If the gate was closed you’d still get the same reading.

  • @nagarasud1441
    @nagarasud1441 3 года назад

    👍, sorry your voice not clear

    • @FlowChart
      @FlowChart  3 года назад

      Thanks for your comment

  • @shalukaindunil5567
    @shalukaindunil5567 Год назад

    Wrong! but after trigger gate pin continuously go A to K path

  • @yabingeng
    @yabingeng 7 месяцев назад

    Be multimeter!

  • @gnanaduraiinbaraj5530
    @gnanaduraiinbaraj5530 3 года назад

    🙏🙏🙏🙏🙏

  • @sudham4618
    @sudham4618 2 года назад

    Not gud

  • @amosolalekan3740
    @amosolalekan3740 Год назад +1

    How will I determine the bad scr

    • @FlowChart
      @FlowChart  Год назад

      Watch video, you will got the point