Excellent Video. I replaced my faulty pressurestat a month ago, opting for the same black one. My thermometer that displays a temperature exceeding 112 degrees on the brew group. I have lowered the pressure to 0.8, which has caused the brew temperature to reach 95 degrees. Could I elevate the pressure to .9 or 1 while ensuring that the brew temperatures remain between 90-95? Your suggestion would be greatly appreciated.
I did replace the pressure stat with the dame model you have added to that machine but The boiler pressure is 2.1 bars and I dont know how to adjust it since that pressure stat dont have the nub to turn and adjust.
Hello, I was having issues with my appartamento not heating, I found that the hi temp breaker had went off and I changed the pressure stat on my machine. However now, my power switch stopped working and upon inspection is appears that one of the leads that connects to the power switch slightly burned (Not melted just yellow discoloring). Do you have any suggestions or an idea what I should be looking at as a point of concern?
@@AustinCoffeeTechnician yes, I do leave the machine on for several hours at a time. I tested the switch and it was dead. I changed both the pressure stat and power switch and the machine is running fine now. Thanks for the response. 👍🏽
When someone disconnects the power supply, the current discharging from the capacitor is equal to the current through the resistor. The voltage decreases exponentially with time.
Thanks great help for replacing pressurestat
Glad to help
Excellent Video. I replaced my faulty pressurestat a month ago, opting for the same black one. My thermometer that displays a temperature exceeding 112 degrees on the brew group. I have lowered the pressure to 0.8, which has caused the brew temperature to reach 95 degrees. Could I elevate the pressure to .9 or 1 while ensuring that the brew temperatures remain between 90-95? Your suggestion would be greatly appreciated.
Surf the temp down by purging the grouphead before you brew.
Thank you
I did replace the pressure stat with the dame model you have added to that machine but The boiler pressure is 2.1 bars and I dont know how to adjust it since that pressure stat dont have the nub to turn and adjust.
those are adjustable. you have to gently scrape away the red coating to reveal the flat head screw adjuster.
Hello, I was having issues with my appartamento not heating, I found that the hi temp breaker had went off and I changed the pressure stat on my machine. However now, my power switch stopped working and upon inspection is appears that one of the leads that connects to the power switch slightly burned (Not melted just yellow discoloring). Do you have any suggestions or an idea what I should be looking at as a point of concern?
I've replaced the power switch on these many times in the past. Do you leave the unit on for long periods of time?
@@AustinCoffeeTechnician yes, I do leave the machine on for several hours at a time. I tested the switch and it was dead. I changed both the pressure stat and power switch and the machine is running fine now. Thanks for the response. 👍🏽
Hello! I believe my Appartamento needs a replacement pressure stat. What exactly is the filter that attaches to it and is it 100% necessary?
When someone disconnects the power supply, the current discharging from the capacitor is equal to the current through the resistor. The voltage decreases exponentially with time.
Hello! Very helpful video! Where can I find that upgraded Pstat?
Hi what would the specs be on that upgraded Pstat? Same as the matar?@@AustinCoffeeTechnician
I would be using it on a ecm giotto classic@@AustinCoffeeTechnician
is that pressurestat a lot better than the stock?@@AustinCoffeeTechnician
no, not better at all.@@Frozenheart1991
Campini.
From where can we buy a pressure switch