How to calculate loads in Frame structure building | कोलम पर कितना लोड होगा कैसे निकलेगा

Поделиться
HTML-код
  • Опубликовано: 16 окт 2024
  • House construction Part -1
    • House construction ste...
    House construction Part - 2
    • Footing & Plinth excav...
    House construction Part - 3
    • Steel estimation for h...
    House construction Part - 4
    • Development calculatio...
    House construction Part -5
    • House construction lab...
    House construction Part -6
    • 10 Biggest mistake in ...
    House construction Part -8
    • Footing failure | Big ...
    Telegram Group
    t.me/civilsite...
    ( OUR OTHER RUclips CHANNEL )
    1. For Job Update
    / @civilsitevisitjobsupd...
    2. For Business Idea
    / @businesskaadda12
    3.Civil Engineer Sharma Ji ( Basic of civil Engineering )
    / @civilsitengineer
    4.Pareeksha ( Job & Exam Preparation )
    / @civilengineerintervie...
    10 Most watched Video of ( CIVIL SITE VISIT )
    1. Tile or marble Flooring
    • मार्बल लगाये या टाइल |...
    2.How to decrease construction cost of House
    • घर बनाते समय इन 5 बातो...
    3.Construction Cost of 1000 Sqft House
    • Construction cost of 1...
    4.Parapet Wall Cheap & Best Design
    • Parapet wall two Best ...
    5.Wall Dampness Treatment
    • Wall Dampness Treatmen...
    6.Marble or Tile Flooring
    • Marble or Tile ? which...
    7.Cracks in wall repair
    • घर की दीवारों में क्रे...
    8.Mistake in House Construction
    • घर बनाते समय इन 8 बातो...
    9.1000 sqft House Material Quantity
    • 1000 sqft का घर बनाने ...
    10.ACC Block Vs Red Brick
    • 1000 sqft का घर बनाने ...
    yr
    CONTACT DETAILS
    ✔Email Id for Business Enquiry - rs140565@gmail.com
    ✔Twitter: Vi...
    ✔Facebook Page: / 100041543491213
    ✔ LinkedIn: / rahul-sharma-66324a215
    ✔Instagram: / civil_site_visit
    ✔Tumblr: / civilsitevisit
    For Business Enquiry
    7006672812 (Note :- Only WhatsApp )
    Disclaimer - This video is for educational purpose only. Copyright
    Disclaimer Under Section 107 of the Copyright Act 1976, allowance is
    made for "fair use" for purposes such as criticism, comment, news
    reporting, teaching, scholarship, and research. Fair use is a use
    permitted by copyright statute that might otherwise be infringing.
    Non-profit, educational or personal use tips the balance in favor of fair .
    #Loadoncolumn #loadcalculationofhouse

Комментарии • 41

  • @shababimran
    @shababimran 2 года назад

    Thanks for uploading this video which i said in comments of previous video

  • @ramandeepsingh6592
    @ramandeepsingh6592 2 года назад

    Good job 👍

  • @yogeshparashar7175
    @yogeshparashar7175 2 года назад

    Sir..mere dilpoma in architect h..Or b.tech in civil engineer..3year job experience h... abhi 6month se khud ka work start kiya h to architecture related koi books hoto guide kriye sir meko...🙏

  • @sumantbouri4857
    @sumantbouri4857 2 года назад +1

    Or agar ek slab jo dusre slab se attach hai.. or agar ek slab ka shorter span dusre slab k shorte span se perpendicula hai to main bar or distribution mai dono slab mai kaise lagayenge..plzzz btaiye sir..

    • @civilsitetechniques
      @civilsitetechniques 2 года назад

      Longer side distribution bar aayenge or short span m main bar ke hisab se lagayenge

  • @AnkitVerma-fy9oh
    @AnkitVerma-fy9oh 2 года назад

    Thanks you very much sir

  • @Asifsultanmehar
    @Asifsultanmehar 2 года назад

    beautiful sharing

  • @tusharbaridun
    @tusharbaridun 2 года назад +1

    Sir self weight of perapet me muje dout he kyun ki weight= volume* density hota he lekin apne sirf width or height hi multipley kiya he or sir slab me bhi muje dout he thikness* density kese aa sakti he usse weight nahi pta chalega

  • @Tarunbhaivlogz573
    @Tarunbhaivlogz573 Год назад

    Sir iska second part b provide kijiye

  • @donot.peek900
    @donot.peek900 2 года назад +2

    Good content sir, because this load reaction Automatically calculated by etabs and stad pro softwares, but we need this for some places. Sir i having dout about formula where ( Lx / 3), in any case 3 is constant or not?

    • @washidali2061
      @washidali2061 2 года назад +1

      No brother 3 is not constant ....3 is the length of the traingular side.

    • @donot.peek900
      @donot.peek900 2 года назад +1

      @@washidali2061 sir LX is shorter length, what about that denominator 3, i asking about that?

  • @MANISHKUMAR-yi7yd
    @MANISHKUMAR-yi7yd 2 года назад

    Sir size of columns or beam
    Hame design karne ke liye assume karna padega ya fir design ke baad size pata chalegi 🙄🙄
    Hamesha assume karna chahiye
    Column ki placing kaise karte hai

  • @dipakkarande9672
    @dipakkarande9672 2 года назад

    Thanks sir

  • @sumantbouri4857
    @sumantbouri4857 2 года назад +1

    Sir slab mai main bar or distribution mai kaise extend hoti hai plzz us par video banaiye...

  • @yashvantmakwana6129
    @yashvantmakwana6129 2 года назад

    Good

  • @avadheshThapa
    @avadheshThapa 4 месяца назад

    सर इतने कम्प्लेक्स क्यालकुलेसन तो आजकल जरुर कम्प्युटर सफ्टवेर से किया जाता होगा, नही?

  • @amazingfactx2
    @amazingfactx2 2 года назад +2

    Sir i think you put the wrong value of floor finish load
    Because assumed is 1.5KN/M^2, this value is for 1 SqM of slab and our slab was 15 SqM, please look at that is it correct or not

  • @rasmitamohanta2231
    @rasmitamohanta2231 2 года назад

    Bhaya ghar banane ka puri proses step wise bataiye 1000 sqft ka

  • @vik_verma03028
    @vik_verma03028 2 года назад

    🔥🔥

  • @priyabratasahoo8383
    @priyabratasahoo8383 2 года назад +1

    👍👍👍👍
    Sir , which Footing is Best for G+3 Building ?? Trapezoidal or Step Footing??
    Kindly make a Detail video on Footing Design for G+3 with Live Site .

  • @krishnachintu7496
    @krishnachintu7496 Год назад

    I wonder why parapet wall load is not subtracted from half load of b1 and b2 in the case of first and ground floor?

  • @hasharfarhankhan2141
    @hasharfarhankhan2141 2 года назад

    slab load= thickness* density
    total weight= self weight*floor finish* live load*water proofing* Fos
    parapet wall weight= b*h**density*Fos
    main wall= l*b*h*density*Fos
    beam weight= b*d*density*Fos

  • @abhishekranjan298
    @abhishekranjan298 2 года назад

    Total load mai 9.1 se multiply kyu hua sir last mai ?

  • @civilsajid1267
    @civilsajid1267 2 года назад

    Sir jee Jo coulmn ka load aya usme f.o.s se multiply karna hoga kiya

    • @sarvagysingh4150
      @sarvagysingh4150 2 года назад

      Yes

    • @sarvagysingh4150
      @sarvagysingh4150 2 года назад +2

      Sorry g Maine pura Deka to pata chala ki fos to sab jagah lekar chal rahe hai to last mai jo column par load ka result aayega uska fos se multiply nahi karenge
      Ok g

  • @abhishekranjan298
    @abhishekranjan298 2 года назад

    Column self weigh mai 9.1 se multiply kyu hua

  • @officelvipinverma5627
    @officelvipinverma5627 2 года назад

    Sir muje job krni h mene 2018 m pass ki h or m kya kru smj nhi aa rha h ab bolte h fresher nhi experience walo ko hayr krte h 😭

  • @aryansonkar6813
    @aryansonkar6813 2 года назад

    Sir pdf upload kr digiye

  • @sohailabbasi9755
    @sohailabbasi9755 2 года назад

    Fit m btao

  • @dipakkarande9672
    @dipakkarande9672 2 года назад

    Sir I.S. Code, technically norm and specification of any item for building send video footing to slab,How to quantity calculated for any item building

  • @nikhilprasaddash7805
    @nikhilprasaddash7805 Год назад

    Confusing video

  • @KushRajput
    @KushRajput 2 года назад

    weight = LxBxHxdensity . but you put the formula BxDxdensity . Do correction

  • @pawansinghadministrator1951
    @pawansinghadministrator1951 2 года назад

    40 /32 fit area me g+3 ka desine +plan bnane me kitna fee lgega . please btaeeye . your watsapp no please