Very nice work but some feedback from me: metal distribution box is recommended to be installed on flamable plywood wall, single phase RCDs shall be used for single phase circuits, torque screwdriver is a must these days, PE and N connections continuity not tested, nor PE resistance, no isolation resistance tested, no short-circuit loop impedance tested, and thus it's not confirmed your MCBs would work, RCD not tested. 2x16A is more than 25A that is max for your three phase RCD and RCD can be damaged just with normal usage. Use at least 40A RCB, or add single phase RCDs for single phase circuits. Three phase connection bar used that looks nice but possibly phase load is not calculated, just assigned random phase to random MCB and thus random circuits. Not sure that three phase circuit od connected right way. Unbalanced phase load raised current on N, connections not screwed to the right torque (what is listed by ABB on your RCD and MCBs), in combination with plastic board on flamable wall can cause fire hazard.
is ne Kabelschere Aber hast schon Recht. Dafür gibt es Abisolierzangen. Manche würden Jetzt behaupten "aus bequemlichkeit oder ich kann das Ja" .. Man macht es nicht.
Sehr schön, dass muss ich demnächst bei meinem Sohn auch noch machen. Was mir aber aufgefallen ist, du hast bei der Phasenschiene den vierten Stift abgeschnitten. Soweit so gut, für den Nullleiter am RCD, dann stimmen aber anschließend die Phasen nicht mehr und damit der Drehsinn für die CEE-Dose, da es mit L2, L3, L1 weitergeht. Hättest du jetzt nicht besser Sw, Gr, Br aufgelegt?
Der Drehsinn bleibt doch gleich bei 2-3-1, also ist alles korrekt angeschlossen. Nur die Farbzuordnung der CEE-Zuleitung stimmt nicht mehr überein mit der Zuleitung zu der UV und anderen Verteilungen im Haus, das ist aber auch wurscht und da gibt es keine Vorschrift. Welcher Außenleiter als L1 definiert wird, ist egal.
Oder einfach ne Phasenschiene von Siemens nutzen: www.zaehlerschrank24.de/siemens-stiftsammelschiene-5st3624-10mm-anschluss-3-phasig-n-8x-phase-4-polig.html
Was mich nur noch stört, L3 der letzte Kontakt wurde keine Sicherung gesteckt. Heißt, Berührungsgefahr. !!!!! Da muss definitiv eine Schutzkappe nach VDE Richtlinie drauf.
Ist das so, dass man in der Garage vor dem Fi keinen eigenen Hauptschalter für den Kasten installiert? Ich habe bei mir einen mit reingemacht vor dem Fi noch, um darüber alles abzuschalten, aber klar, ginge auch über den Fi.
Ich vermute der Verteiler für die Garage hängt im Hauptkasten hinter der Haupsicherung an einer Abzweigklemme, somit kann man damit die Garage "komplett" stromlos (also auch das Kabel dahin) machen. Allerdings hat man dann für die Zeit auch kein Strom mehr im Haus dann.
Klasse, lehrreiches Video von dem Mann mit dem sagenhaften Seitenschneider......Danke!
Sauber und zügig gearbeitet!
Das Drehfeld kann man an der Cekon passend einstellen.
Very nice work but some feedback from me: metal distribution box is recommended to be installed on flamable plywood wall, single phase RCDs shall be used for single phase circuits, torque screwdriver is a must these days, PE and N connections continuity not tested, nor PE resistance, no isolation resistance tested, no short-circuit loop impedance tested, and thus it's not confirmed your MCBs would work, RCD not tested. 2x16A is more than 25A that is max for your three phase RCD and RCD can be damaged just with normal usage. Use at least 40A RCB, or add single phase RCDs for single phase circuits. Three phase connection bar used that looks nice but possibly phase load is not calculated, just assigned random phase to random MCB and thus random circuits. Not sure that three phase circuit od connected right way. Unbalanced phase load raised current on N, connections not screwed to the right torque (what is listed by ABB on your RCD and MCBs), in combination with plastic board on flamable wall can cause fire hazard.
Ja, und dann noch den Schutzkäfig gegen Meteoriten Einschläge vergessen 🙃
Geht's noch?
🐛
Klasse, mit Seitenschneider die Adern abisolieren.
is ne Kabelschere Aber hast schon Recht.
Dafür gibt es Abisolierzangen. Manche würden Jetzt behaupten "aus bequemlichkeit oder ich kann das Ja" .. Man macht es nicht.
Sehr cool Video machen ohne Erklärung 👍
Beim Letzten Zinken bitte noch ein Abdeckhütchen hinmachen, wegen berührungsschutz, sonst top
Sehr schön, dass muss ich demnächst bei meinem Sohn auch noch machen. Was mir aber aufgefallen ist, du hast bei der Phasenschiene den vierten Stift abgeschnitten. Soweit so gut, für den Nullleiter am RCD, dann stimmen aber anschließend die Phasen nicht mehr und damit der Drehsinn für die CEE-Dose, da es mit L2, L3, L1 weitergeht. Hättest du jetzt nicht besser Sw, Gr, Br aufgelegt?
Danke , aber für schine , das ist nur provisorisch
Die ABB Schienen bei denen der 4. Stift schon fehlt, geht es auch mit L2 L3 L1 weiter.
@@_alexsworkshop_ Das ist richtig, auch da hätte er besser Sw,Gr,Br aufgelegt.
Der Drehsinn bleibt doch gleich bei 2-3-1, also ist alles korrekt angeschlossen. Nur die Farbzuordnung der CEE-Zuleitung stimmt nicht mehr überein mit der Zuleitung zu der UV und anderen Verteilungen im Haus, das ist aber auch wurscht und da gibt es keine Vorschrift. Welcher Außenleiter als L1 definiert wird, ist egal.
Oder einfach ne Phasenschiene von Siemens nutzen: www.zaehlerschrank24.de/siemens-stiftsammelschiene-5st3624-10mm-anschluss-3-phasig-n-8x-phase-4-polig.html
Интересно, а что за красные язычки в верхней части автомата?
Bravo
Sehr gut weiter machen mit viel erfolg.
Great
скільки вільного місця а ніякого запасу провідників не залишено??!!
Das Video wäre für mich vielleicht sehr hilfreich gewesen wenn es auf deutsch besprochen wäre......
Was mich nur noch stört, L3 der letzte Kontakt wurde keine Sicherung gesteckt. Heißt, Berührungsgefahr. !!!!! Da muss definitiv eine Schutzkappe nach VDE Richtlinie drauf.
Odlično
Muito Top
Ist das so, dass man in der Garage vor dem Fi keinen eigenen Hauptschalter für den Kasten installiert? Ich habe bei mir einen mit reingemacht vor dem Fi noch, um darüber alles abzuschalten, aber klar, ginge auch über den Fi.
Ich vermute der Verteiler für die Garage hängt im Hauptkasten hinter der Haupsicherung an einer Abzweigklemme, somit kann man damit die Garage "komplett" stromlos (also auch das Kabel dahin) machen. Allerdings hat man dann für die Zeit auch kein Strom mehr im Haus dann.
Sauber gearbeitet 😀👍
was ist mit Schutzisolierung?
Ich glaube besser für CEE Steckdose von C16 Sicherung benutzen 🙄🤔
Hat er auch benutz, aber in der Beschreibung am Ende schreibt er B16 3-polig
Uyt
Eline sağlık çok güzel olmuş
Großes Gezappel mit der Kamera,Drahtverhau oben links!
Abisolierzange gibt es nicht 🙄🤔
Ich benutze nie ;)
Enteschuldigung was ich gesagt aber hier in Brasilien unser eletrik system ist hatt besser qualitat.
Das geht auch schöner, sagen mir so des schaut beschissen aus!
Und ist auch eher ein Pfusch!
Wasn daran Pfusch ?
Pfusch
Szajse