Stack Testing - AIR, Inc

Поделиться
HTML-код
  • Опубликовано: 18 дек 2014
  • At AIR, our technicians are well experienced in all of the EPA's standard testing methods, as well as many NIOSH, OSHA, NCASI, and state methods. Over the last decade, we have completed thousands of testing projects with multiple testing methods utilized.

Комментарии • 36

  • @agbertofragoso6476
    @agbertofragoso6476 5 лет назад +4

    Hello everyone, I work 10 years with atmospheric emissions in Brazil, it is very interesting to see other collectors around the world ... not always the sources are standardized.

  • @Alliat6364
    @Alliat6364 4 года назад +5

    Very interesting to see other stack samplers work. I work in Iceland and we have the same sampling train, but a different console model. This is good stuff!

  • @apexinstrumentsinc
    @apexinstrumentsinc 7 лет назад +6

    Also, we are proud to see our equipment being put to good use! :D

  • @polycarpodiedo4274
    @polycarpodiedo4274 4 года назад +2

    Loving the handling of impingers . I do this everyday . Labworks EA Kenya .

  • @JSXADMIN
    @JSXADMIN 8 лет назад +2

    oo nice to see videos of others in the industry in other parts of the world :-D

  • @joeamerican3947
    @joeamerican3947 4 года назад

    Wow, you guys really have grown alot!

  • @muratkansu3774
    @muratkansu3774 5 лет назад +2

    Duct diameter ? Total traves point ? Check test

  • @apexinstrumentsinc
    @apexinstrumentsinc 7 лет назад +4

    Cool video. One note: Isn't is just the same footage looped after the 13th minute?

  • @putramemet9958
    @putramemet9958 5 лет назад +2

    So far so good

  • @masilela_sa9621
    @masilela_sa9621 8 лет назад

    which method is this?

  • @user-mc1qm7nr5m
    @user-mc1qm7nr5m 2 года назад

    I'm from Thailand I started this career as well.

  • @redman382002
    @redman382002 5 лет назад

    interesting design for your probe stand, especially for ports that do not sport the unirail type of system. Interesting too is marking the unirail for your point and not the probe itself, this would especially be useful with high temperature stack, that would burn off most marking on the probe.

  • @rommelb.omegatv274
    @rommelb.omegatv274 3 года назад

    Did they get the pre wt of impinger and silica?
    Did they use ice in cooling the impingers?

    • @LazyScoutJace
      @LazyScoutJace Год назад

      Nah, fam. Weighing and icing is for pussies...

  • @rommelomega3023
    @rommelomega3023 9 лет назад +1

    Did they put ice to chill the impingers? did they weigh the silica gel before and after testing?

    • @tharwatnoor3904
      @tharwatnoor3904 8 лет назад

      + ?
      Rommel Omega good question

    • @stevejones8074
      @stevejones8074 7 лет назад

      This is Hollywood bro, No ice req and of course they pre weighed the SG

    • @sakhumzibaliso5731
      @sakhumzibaliso5731 5 лет назад

      @@stevejones8074 but if you don't put ice, how are you going to sample a dry gas?

  • @stevejones8074
    @stevejones8074 7 лет назад

    Looks like an asphalt plant, def a bag house, so I`d go with a method 5

  • @mangeshmundhe8248
    @mangeshmundhe8248 3 года назад

    thanku sir

  • @Justindanet
    @Justindanet 7 лет назад +1

    no post leak check?

    • @charleshollingsworth1583
      @charleshollingsworth1583 7 лет назад

      i worked for roy f. weston for 15 years and traveled 90% +++ a year probably been on more stacks than most will ever see. if we had had chevy trucks we would have never made it to job sites,, heck probably would have never made it out out of auburn alabama. if one of my boys had skipped a post leak test they would be made re run the whole test run. go apex instruments did they even pull a orsat//not even a fyrite sample.. our probe washes on my projects were done in mobile lab aka 3 probes used to test. as 75% were pulp and paper mills..

  • @ATTBV
    @ATTBV 4 года назад

    Obviously not a real test but a nice video to show others roughly what we do. So many things could be called out but given it was a dummy test I'll let yous arf! Good luck guys!

  • @paulclark9968
    @paulclark9968 8 лет назад

    and this testing is not to UKAS Std....

  • @masilela_sa9621
    @masilela_sa9621 8 лет назад +1

    that's what I do, Monday to Friday

  • @timruss9478
    @timruss9478 4 года назад

    Didn't brush nozzle out

  • @richwilliams6010
    @richwilliams6010 5 лет назад +5

    No piss bottles? Amateurs

  • @dmac5964
    @dmac5964 6 лет назад

    Why don't you assemble the trains down in the vans and haul them up with ice? You have to weigh what goes in the impergers. It's funny you guys wear harnesses also.

  • @taty4545envi
    @taty4545envi 8 месяцев назад

    ทำไม นายไม่เสียบแล้วรูปแล้วลงมา แดดมันร้อน😂😂😂

  • @timwaller8746
    @timwaller8746 7 лет назад

    No measurement of the stack diameter or nipple measurement. Show me your Method 1.No cyclonic flow check or pre-test flow to determine your nozzle size?No recovery flask while cleaning the probe with acetone before testing? Just dump the acetone on the ground.There is an easier way to load that silica gel, use a 500 ml narrow mouth bottle and pour it in via the outlet side of the imp.I know, the plant was not even running. It was too quiet. LOLBig Jim IAS

    • @LazyScoutJace
      @LazyScoutJace 6 лет назад +3

      Watch out, we gotta badass over here.