Thank You Sir I Repaired my Service Valves in Rs 20 ( without gas) Only ,My AC Technician was saying he is going to change both Service Valves and estimate me around Rs 4000 without gas I did it myself Thank You again
Well sir very good technical experience so thanks you sir No time waste... No cost.... And urgently ready with out extra time and welding tools no Need to buy new valves
@@muhammedsaoud1364 1st u need to close the small valve then run the ac after the start of the compressor wait for 30 secs then close the big valve and switch off ac. then u dismantle the AC
Sir,1ton ac pressure = 50 pressure podhum gas22 1.5ton na 60 pressure gas 22 2ton na 70 pressure gas 22 Solluranka athu sariya Or All 22 gas ac kum pressure pothuma
Sir.. Aluminium condenser coil ko copper ke sath brazing kar sakte hai kya (1.5 ton split AC). Service center is asking to replace the full condenser coil with copper make. Agar refrigerator ke case me copper and aluminium ko jod sakte hai to AC ke case me kyo nahi? Plz guide
Please i want to buy these service valve ports for my 2 hp LG air conditioner online. Your o rings are the same size like mine when i remove the service valves. Im seeing various sizes of service valve ports like 1/4, 1/2, 3/8, 5/8 sizes online. Please how do i know the right size for both of my vapour and liquid line service valve ports? Also whats the size of these service valve ports on this AC. Thank you
भाई साहब मुझे आपकी बनाई वीडियो बहुत ही अच्छी लगी थैंक यू
ONE OF THE MOST WAITED FOR VIDEOS in the line of air conditioner repair. Thank you, Sir, what a save of time and money.
Good yar....esa vidio mene Aaj tak nahi dekha.... Good
AJ Kuch Naya sikhne ko Mila yr
Thoko like
Very nice bahut achhi jankari samjhane ka tarika bahut hi achcha ha
Tnq bhayya mai ac mechanic 9 years per yeah valvues mai change kar deta hu .... Aaj mai aap se achhi baat sikha hu
Thank You Sir I Repaired my Service Valves in Rs 20 ( without gas) Only ,My AC Technician was saying he is going to change both Service Valves and estimate me around Rs 4000 without gas
I did it myself Thank You again
Great job
Brother help me from where to get rubber ring washer? Share me with link.
Did you solve the leak by o ring replacement?
Absolutely sir ji,,,,aise hi achchi achchi information upload karte rhiye ham jaiso ke liye ap ek margdarshak ho tnx,,,
Very good
Wow excellent repair. Good sir
Learn the good techniques. Thanks
Thanks for watching!
Well sir very good technical experience so thanks you sir
No time waste...
No cost....
And urgently ready with out extra time and welding tools no
Need to buy new valves
Very nice video sir
Very good information for AC technician sir Ji thanks very much
Super sir
nice video thank you
Very nice video.
Great video! You're on spot. Thank you!
Good explain sir.thank you 😄
Welcome 😊
Thank you very much something new to learn about new .
Good Job Sir 👍👍👍👍👍
very nice.. very useful to me
Good point to learn.
Indeed!
Bahut Achhe sir
Very few people explain as well as demonstrate things so clear and straight. Thanks a lot
Excellent
Very Informative Video Thanks Bhai jaan 💞
زبردست 👍 kb cool in Pakistan
Fantastic
Very useful information, thanks lot!
Glad you enjoyed it!
Thanks for knowledge sir
شكرا علي المعلومات الجميلة
Thank you so much sir
Nice one sir
Good video sir काफी टाईम बाद आपने video बनाई आप ने
Super ji
Thank you sir
Thanks sir
جزاك الله خير انت نمبر ون👏
Soma sir
Very nice information
Please improve the quality of video and disturbance etc
Always you are a practical man . Good information .
Thanks
Good idea sir
Show very good. Tks..
Awesome, my mechanic was asking me for 3500 hundred, fortunately I had seen your video.
I kicked him out.
sir actually 99.9% technician don't know how to repair AC valves. so we made this video for them.
@@SomaElectricals Appreciate your effort.
If you know someone in ulhasnagar, do let me know please.
@@jaiprakashmahtani68 sir we do service in Hyderabad only
Aur bano sir aise videos new Commerce k liye
Nice sir
Thanks and welcome
Mashallah Mashallah nice work
sukriyaa
Super video sir, gr8 info. Thank u.
Super sir tq for information do more sticks
Thanku sir
Jadatar koi is o ring change nahin karta hain.leak hora hai to cap lagadeta hai.lekin aap jo hai proper kam karraha hai.good very good 👍
thank youj
very2 informatif sir👍im struggling with how to pull the valve stucked due to o ring😂
Shukriya Bro
great .
You are great geanius
Nice share bai
If we see you selling gas parts, please request information
From- jamnagar,gujrat,india.
Good vibes
Sir great ideas.but we see you are clean lkey wall but you must put in side grees
i already sprayed wd40 before removing valves so there was much lubricant
Good
Great idea sir i m from Bhubaneswar
excellent.
Thank you! Cheers!
kamal janab
Thanks
Nice jankari
Thank you.
Terima kasih Bro.
thanks sr for video
Nice bhai
Suparb sir
🌹🌹🌹🌹❤️👍Thank you
👌
super
Sir koi aisi video banao jis mai easy compressor mai oil change kr sake
AC outdoor unit ka server valve thread kestara repair kr skte hy bilkul new hn ajj Lea hn AC aor thread (choori) teek nahi eska ye msla ab
Supare bro.
Is it useful to change the compressor adjustment 3 hp with another 2 hp
u need to change same HP compressor
@@SomaElectricals i closed the big valve before the small one to move the ac to another location , how can i fix this?
@@muhammedsaoud1364 1st u need to close the small valve then run the ac after the start of the compressor wait for 30 secs then close the big valve and switch off ac. then u dismantle the AC
Amazing dear
If we see you selling gas parts and brass charging NRV, please request information
From- jamnagar,gujrat,india.
Well subtitled in English. Good job. Please can you change the two O rings without evacuating the refrigerant gas?
not possible
@@SomaElectricals ok..thank you. Please how do I vent out the refrigerant without losing much oil from my AC so I can work on this service valve?
@@safetyalways7788 open the discharge v alve half turn let gas vent away
@@SomaElectricals ok thanks .., also can I use vacuum pump or charging hose to vent it as well without losing much oil?
@@safetyalways7788 yes
u can use vacuum pump also
Sir,1ton ac pressure = 50 pressure podhum gas22
1.5ton na 60 pressure gas 22
2ton na 70 pressure gas 22
Solluranka athu sariya
Or
All 22 gas ac kum pressure pothuma
Sir.. Aluminium condenser coil ko copper ke sath brazing kar sakte hai kya (1.5 ton split AC). Service center is asking to replace the full condenser coil with copper make. Agar refrigerator ke case me copper and aluminium ko jod sakte hai to AC ke case me kyo nahi? Plz guide
haan kar saktey hain
Don't forget put oil face oring before install valve
Thanks bro?
I'm first viewer. Nice information
thanks sir too much let all are fine sir grea sir
Please does the same size Allen key open the two service valve?
yes, both valve Allen key size is same
Hello .. I have a question ... If you collect the coolant, and unscrew the valve, the liquid will be lost ??
we need a refrigerant recovery unit. www.amazon.com/Robinair-RG3-Twin-Cylinder-Portable-Refrigerant/dp/B00NMOYPVG
I have aluminum coil valves...are those repairable too?
yes
Please what's the o ring material that's suitable with R22 refrigerant?
silicon
Wow
Did you solve the leak permanently by replacing the o ring? Is replacing the o ring better than brazing new service valve to the condenser?
better to change O rings, why waste of money and time for replacing total set
dono valves ko kitma open karna hota hai optimum cooling k liye
fully open karna padtha hai
Please i want to buy these service valve ports for my 2 hp LG air conditioner online. Your o rings are the same size like mine when i remove the service valves. Im seeing various sizes of service valve ports like 1/4, 1/2, 3/8, 5/8 sizes online. Please how do i know the right size for both of my vapour and liquid line service valve ports? Also whats the size of these service valve ports on this AC. Thank you
remove old service valve, take to spare parts shop u will get there
Sri can I get o ring for the value
Yes. Buy link in video discretion
Thanx sir for knowleg add me
Which no Allen key use to gas service.please tall me
5 mm in this AC in some model 4 mm comes
R410 ke unit mai r22 compressor work karega
No compression fail hojayega
Use compresed air
that also a good idea never thought thx for info
Haier inverter ac 1 ton ka gas pressure R410a ka running pressure
110 TO 120 PSI
It's better in eg