How To Flush Air Conditioning System
HTML-код
- Опубликовано: 19 май 2019
- For Order in India WhatsApp: +91 9848461408
Support our Channel: ruclips.net/user/somaelectrica...
Follow Us / somaelectricals
Buy link Flushing Canister Amazon India: amzn.to/3OZTYPh
Buy Link Flushing Canister India: amzn.to/3vgDefB
Buy Link Flushing Canister U.S.A: amzn.to/2S0hyBg
Demonstration of the flushing air conditioning system. Use extreme caution when working with this equipment and chemicals. Wear appropriate safety gear. Pressurized equipment is hazardous, use it at your own risk.
If you Want to buy contact Us on WhatsApp No. +919848461408
www.banggood.in/custlink/Km3D...
The torch I use: amzn.to/2My2LI8
Buy Capillary tube cutter: amzn.to/36Qp8jG
Buy link Flushing Canister India: amzn.to/3hYMkC7
Protective Clear Face India: amzn.to/2X9Gcft
Protective Clear Face Worldwide: www.banggood.in/custlink/GK3v...
Follow us on Facebook: / somaelectricals
#somaelectricals #airconditioningsystemflushing #airconditioner #flushingcanister
Nice video.Your workshop dog is very cute and this shows that you are a very good person by nature.Thanks
Hi all.
1. Using thinner is dangerous. Highly inflammable. Better alternative to be used. R-11 is not environmentally friendly. Highly damaging.
2. The thinner canister doesnt have pressure relief valve. In case the capillary is blocked, raising pressure in the canister with thinner. Not a safe one if it blasts.
3. Use of air under pressure! A big no to such pressurisation. Use of Nitrogen with regulated supply is safer. Being an inert gas, fire accidents can be averted.
4. Does the thinner evaporate fully without leaving any residue? Internal condensation may happen when air is pumped as the thinner evaporates and leaves in reverse.
Have you tried cleaning/ flushing the condenser keeping vertically as U bends & internal surfaces may still hv sticky oil and dirt..
Safety first.
Thanks
Nicely explained.
I use nitrogen and CTC but some times CTC is still in evaporated what is the best solution..??
@@ASPO-yk9nv where i can get ctc ?
Can we use rectified spirit ?
@@DevPanigrahy Carbon tetrachloride can be used to clean... You can find in.. ac spares dealer shop
Bahuth accha hai bayya , keep posting, TQ
very educational, GOLDEN WORKS TV
Bhut achhe se aap samjhate hai sir mast samajh me aata hai
theirs a reason why we all use nitrogen for that , i use 141b cleaner im trying to imagine why and i respect your effort but we have to follow and learn from the best , this is not a cheap work it has hight repair cost i know what your trying to do but at the end your clients are not going to appreciate what you do for them , i used to get mad watching people charge so little money leaving me with out work , so i started learning from the best and right now i have a lot of work especially from people that dont do their work correct and thats where the money is in the repairs. stay safe god bless you.
Very good job sir
Behtrin work good technician
Thanks sir nice information.
👍Good sarji
Good information sir.
Good work
La kok go tiner blasinge bro po ko ra bleduk der boom ,good job sek penting jalur gas olie dadi resik clear ,salam cool indonesia jawa ngayogjokarto hadiningrat sleman
Thanks you.
bhai appka vides super👍
Very very useful
Superb 👌👌👌
Super bro
Thakns for video
Good job
Nice video sir
Nice work...thank you
Welcome 😊
Very good 👍👍👍👍
Thank u sir. Very helpful for me.
Most welcome
Good bhai ham log bhi saudi me petrol se flash karte the jaisa app bole thiner pura bhar ana chahiye aur Dhoop me thodi der dry karna h thnx
Petrol plus compressed air will cause explosion
Thanks bahi
Nice video
വളരെനല്ല വീഡിയോ ബ്രോ
Super Hindi mai speak karne ke liye thanks
Good job brother 👍
Thanks for the visit
Nice sir
I am using my 1T split ac for about 2 months in a year.
What should be the frequency of cleaning its evaporator and condenser coils?...
when summer starts thats all
dogi bohat peyara hea mujea yea bat ache lagi k ap janwaro ko payar kartea ho mare tarha
Use r11 for flushing and use vacuum after wards
Osm sir
Good work 💪
Thank you! 😊
Super sir
nic videos sir
Sir, your video is awfully helpful. I would like to make some points. 1 As soon as the thinner came out during the first flush you should have stopped the compressor and started after say 10 or 15 minutes because this stopping would give the thinner time to dissolve more dirt and thereby saved some thinner. 2 You have fixed a gauge on the canister but we could never see the pressure at which the thinner was being pumped into the condenser, at least you could have just mentioned it. 3 I wonder why you changed the entire 2 service valves as one could have just taken out the circlip, replaced the thin "O" ring with a new washer and fixed the circlip back that would have saved your customer some money.
Sir r u in Delhi..nd do you service ACs or know somebdy as learned as yu
@@artivedi3887 Dear Sir, i am sorry. I shouldn't have commented anything.As in my previous comment i didn't consider the time factor. These days who can afford to waste time . So now i feel what you did is best.
best method of flushing by CTC and nitrogen
Good sir
Thanks you sir aap bahot bistar se batate he
thx
Good information Sir
Thiner dalne ke baad nitrozan v dalenge kya aap sidha gas dalne pe ho jayega
Thank you dear sir
Most welcome
Nice video sir
Thanks you
Wow 😍😍😘
Good
سسسسووووووپپپپپپپییررررر
Ssssssssuuuuuuuppppppeeeerrrrrr zabar dast booohat alal
Thank You
You're welcome
bhi na petrol say saf kartea hea na thinner say
Very niec veduo
Mashaallah mashaallah mashaallah mashaallah mashaallah mashaallah
Good sir nise.q
Bhai ye flashing 410/R32 22 gas k outdoor m Kar sakte. H kya
yes
My friend you are flushing the condenser coil thru liquid line not discharge line. Coz this video watched by many people.
Boss plzzz use R11 gas
Muito bom
thank you
And vacuum AC with vacuum pump
Good info
Glad you think so!
Thinner thoda complicated he kya.? Nitrogen best?
Nitrogen only like a air hai agar aap ko pipes main contaminants particals nikala hai tho thinner or white petrol use karna padega. jai say pani tho hai per pani say mail nahi jayega tho mail janey kay liye soap hona jaroori hai
Nitrogen best
Jo app thinner use kr tee hai
Vo pura nikle jata hai condensor mai say ?
haan nikal jata thinner bahut jaldi dry hota petrol say bhi jaldi
nice video sir what type thinner can use thanks.
NC thinner. u can use CTC or White petrol, rx11gas
Very nice sir ji
Inverter compreeser ko check krne ka koe instruments bna rakha h kya agar to please provide me
@@ebraamvlogs नहीं बना है
👏👏👏👏👏
Dear Soma when i change the compressor i should flush the AC ?
yes it will good if flush system
V good joob
Sir is this the same lg ac that you changed with a new Whirlpool compressor
Whirl pool name compressor not. available in market, LG, Panasonic, gmcc,
its available check out
Sir compressor ke alawa naitrozan ka use kr sakte he kiya?
haan kar saktey hain nitrogen
👍👍
Cappilry fishing kaneke liye konse company ka achcha thinner use Kare.
sinlec company ka
Very nice
Thanks
Price to sir hame de kya hai
Sar ji rotary compressor mein oil kis side se charge hota hai suction ya discharge please bataya.
koi bhi side say dal saktey ho oil
A66a kon sa hoga sir
For flushing should we use only thinner or even CTC is ok
thinner is better than CTC. we can use both
👌👌👌👌
Sir ji r410 compressor ki jagah r 22 ka compressor laga sakte hai keyaa
Agar aap ka compressor non inverter hai tho 22 ka compressor laga saktey ho
Agar inverter AC hai to
Yes
Dusray compreasor ki jagah nitrozen use kr sktay hai kya sir
kar saktey hain
What fluid you used to flush the system? look like gasoline. Is it right or alcohol 90 ?
i used carbon tetra choride. u can use thinner, white petrol, or alcohol
Thanks. there are a few pro ac flush in U S; however, they are so expensive with a small amount and it is very hard to flush a whole system thoroughly. thanks
Jab meri ac me problems aaya to maine aapki saari videos dekh le but problem samajh me nahi aa raga hai. maine apne voltas split ac me pehle vacume kiya 1/2 ghante aur phir gas charge kara r22 60psi @7.1 amp par . Lekin gas sahi se charge nahi ho paaya ab discharge line thandi hoti hai indoor unit tak but suction line thandi nahi hoti aur na to outer fan garm hawa deta hai . 2 - 3 mint me compressor heat ho kar trip kar jaata hai. Kya problems ho sakti hai. Ab mujhe caplleri tube jaam lag raha hai. Please upae bataeye?????
aap compressor pressure check karo discharge per 500 psi tak aana chahiye. agar 500psi aa raha hai tho compressor pumping teek hain aur capillary bhi. agar pressure nahi aata hai tho capillery check karo
@@SomaElectricals thank u very much for your reply...i will try tomorrow..
I think thinner is very explosive liquid we should use r11 for flushing.
what about R141B?
@@jiliangarcia6273 yea it works
Agar ac 410 no gas ki ho gi to bhi coli ko thinar se flas kar sakte hi na sir
rx11 gas karna hai
Super
Thanks
Sir iski ander koch thiner rehe gaya to system ko problem hosaktahe ki nehi?
kuch nahi hoga dry ho jatha hai thinner. petrol say jaldi dry hota hai tinner
Central Ac control pc bord telme
Kitne number ka thineer use kare fridge ac msin plz bataye
paint thinner use karo
Ok.thanks for reply
Bhai sahab nitrogen se flash Karte Hain aur saath mein aapne filter aur kya Pari disconnect Nahi Ki aapka
Sir deril kitne ka hi
Sir ek split ac hai standing me 120 psi hai lekin running me 20 psi hi hai aur running me gas dalne par bhi gas nahi chad raha hai kya problem hai pls reply thanks.
puri gas nikal kar vacuum kar kay gas dalo.
Sir LG ka singledoor freez h wo din main barf jamata h pr rat ko ice nai jamata kya problem ho sakti h
Sayad fridge raat main sojatha hoga. hahahha. majak kar rahu hu.. aap fridge ki PTC relay change kar kay dekho aur fridge ko walls say thoda door rakho
Sir fridge k compressor kun s size k sath is ko pressure dy salty agar ac ka compressor na ho to jo video main ap n dekhya ha
flushing kay liye pressure hona jaroori hai. ac compressor must. ya nahi tho nitrogen
Phlusing karte samay aapne nhi bataya konsa valve band rkhna konsa chalu aur compressor se presor kaise dete hain detel me btaoge to hum jaldi sikhege
Ek Baar Phir Se Dekho samajh mein aa jayega
I am from mumbai
Ek number flushing bhai
Mujhe bhi cylinder do kaha milega
video ki description main link hai aap waha say buy kar saktey ho
Plz explain in English language so ur video can view by any country in the world
Refrigerator freezer Kaise clean Karen kya Ctc puri vaporize( nikal ) ho jayegi freezer se
ctc say kar saktey ho. pura vapor ho jayega
@@SomaElectricals thank you
APNE AC K WORKING PARTS KO JAANE,, BEHTREEN VIDEO.. @
English subtitles please
Indoor aor outdoor dono KO sath me flusing kar sakte he kya
alag alag karna hai flushing.
what is the maximum pressure of the bottle ???
150 psi