Low Water Cut-Off Replacement On Weil-Mclane Boiler. But Why Two?

Поделиться
HTML-код
  • Опубликовано: 9 фев 2025
  • Let’s get this LWCO replaced!
    In this video we remove a defective low water cutoff and replace with new.
    Want to purchase a TopTes leak detector? Use the links below and use the discount codes to save $$$!!!
    PT210S
    amzn.to/3QSHJEu
    Discount Code: GSYQFS4Z
    PT299
    amzn.to/3R38JlS
    Discount Code: 4A3HH88Q
    PT199
    amzn.to/3M5kTYs
    10% off with code: N83SX3Q6
    PT520B+ Professional Gas Leak Detector amzn.to/494fISD
    10% off with code: R98D8JH8
    Also Check out these great products I use on a daily basis! Use the links and save some $$$
    Inficon Gas-Mate Combustible Gas Leak Detector amzn.to/40ifEdL
    Tesman TN-213 NCV Tester amzn.to/3rVZY3j
    10% off with code: FJDYR4W3
    Topdon Thermal Camera for Android amzn.to/46Wldkf
    Topdon Thermal Camera for iPhone amzn.to/46Twvpu
    Elitech DMG-4B Digital Manifold bit.ly/44TKlXD
    Discount Code at checkout: JeffsHVAC5
    Support the Channel with a Super Thanks or
    PayPal: ​⁠@JeffsHVACAdventures
    CashApp: $JeffsHVACAdventures
    Venmo: @JeffsHVACAdventures
    Like and Subscribe!
    Questions, comments or to just say Hi, email me
    jeffshvacadventures@gmail.com

Комментарии • 16

  • @JonCroce-q8h
    @JonCroce-q8h 14 дней назад +1

    NYC for commercial building . Boiler require 2 low water cut off & they what you to hard wire your smoke detector to boiler

    • @XxAyOoRiCkY139xX
      @XxAyOoRiCkY139xX 12 дней назад

      I was coming to say the same thing 2 lwco and 2 pressure switch one of each has to be a manual reset.

  • @jeffreyhalet9632
    @jeffreyhalet9632 Год назад

    In case someone says Double hog dare ya…
    Better have 2 guard dogs 😂😂😂

  • @Bob.W.
    @Bob.W. Год назад

    I think code requires a 2nd cutoff in certain states for boilers above a certain btu rating. That's a big boiler. I had 550,000 WM EG-11 in my house. Was able to replace it with an 8 section Burnham Independence.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Год назад

      Didn’t think about that. Good point

    • @georgebrabec1749
      @georgebrabec1749 Год назад

      ​@JeffsHVACAdventures Somebody might have been thinking about redundant protection. Better to have 2 than none !

  • @nayemhossain4283
    @nayemhossain4283 3 месяца назад +1

    Code over 300000 btu requar two low water cuts of one manually push to one ,if cut off

  • @georgebrabec1749
    @georgebrabec1749 Год назад

    Sometimes you could have 2 LECO's , one being used as the actual burner shutdown and the second one controls the make-up wster valve.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  Год назад

      Very true. These two basically shut down the same thing tho. The one I replaced cut main power to the boiler, the other cut power to the ignition control board.

  • @databasespace
    @databasespace Год назад

    maybe a odd safety feature, one for each burner but wired diffrently

  • @desieranks
    @desieranks 2 месяца назад

    They always put 2 of the same safety on Comercial boilers

  • @zlo92x21
    @zlo92x21 Год назад

    The size of the boiler is why I believe

  • @mikewhittaker5984
    @mikewhittaker5984 Год назад

    Same reason it has 2 valves pads the bill

  • @Irilia_neko
    @Irilia_neko Год назад

    Redundancy is the reason I think