How to Really Test a Low Water Cut Off Probe

Поделиться
HTML-код
  • Опубликовано: 8 фев 2025
  • low water cut off probes are one of the most important parts of any boiler. It does not matter if it is for a home or building. Low water cut offs protect the boiler from damage. they should be looked at every year. If any signs of damage are found, it should be fixed or a new one put on. It is better to be safe, then sorry. steam boilers do not run with a full water level inside. They should be looked at as much as you can because any loss of water could be a big problem if it is not fixed.

Комментарии • 15

  • @pipers255
    @pipers255 Год назад +2

    my company switched me over from plumbing that I’ve been doing all my life to maintenance on boilers to service, and you just taught me something
    Great work

  • @brooklynboi11207
    @brooklynboi11207 Месяц назад

    Very informative. Got my sub

  • @captainwho1
    @captainwho1 Месяц назад

    You lost me when you set the meter to Ohms but then got a measurement in Volts. My new probe measures 7.3kOhms to 7.6kOhms after counting to 10 secs. This is with the boiler water hot after a burn cycle. It seems to be like measuring the resistance of a capacitor where the longer you test it the higher the resistance goes, as if it is charging up during the test procedure. Maybe we should be measuring capacitance?

  • @raindogs451
    @raindogs451 Год назад +1

    Is there a typical life span on one of these probes? Are ]you changing based on the gunk build up?

  • @ricklee827
    @ricklee827 Год назад

    Let me guess there was an auto feed on the boiler?

  • @saefunnaja
    @saefunnaja 4 месяца назад

    Hi sir, what's the best electricy for this probe? AC or DC?
    i've tried using DC 12v but it decrease become DC 6v.
    i've also tried using DC 12v it also decrease become 8-12v
    right now i'm still waiting for some parts using AC 24v, is it safe?
    Thanks for your sharing

  • @allenrobles9064
    @allenrobles9064 8 месяцев назад

    Good video

  • @BGoetz1182
    @BGoetz1182 5 месяцев назад

    What is that black round/balloon thing that you cleaned out? Does that have to be cleaned out annually? If so, do I need to buy gaskets every time I do that?

  • @robwhiff3411
    @robwhiff3411 3 месяца назад

    My lwco hydro level 400 has a slight dimmed light at all times, it does turn bright orange when water is low and shuts boiler off, could it be the reason why my McDonnell-Miller feeder continues to feed more then one cycle because probe is not grounded properly and causing the slight dimmed orange? Thanks

  • @smithno41
    @smithno41 Год назад

    All the ones that I work on are so old they have a float type low water cutoff.

  • @robwhiff3411
    @robwhiff3411 3 месяца назад

    I was wondering if you can give me some input on, I have a new steam boiler McClain 35 series with a 400 water cut off , I installed with a friend a new McDonnell miller universal 24v water feeder and when I test to fill when water is low it fill to the glass line then it pauses for a few and starts filling again to the point of overflow so I have to shut it off because it repeats the process about 4 times before it stops , what do you suggest is going on ? Thanks

  • @tuppersdad
    @tuppersdad Год назад

    Remove and clean every year.

  • @PawsumGaming
    @PawsumGaming Год назад +1

    good ole fail safes... when they fail...

  • @hvacguy11
    @hvacguy11 11 месяцев назад

    What happened to this guy