How to Wire a Hot Tub...Wiring a 220/240 Volt Spa***I will show You step by Step easy to follow Info

Поделиться
HTML-код
  • Опубликовано: 27 мар 2022
  • **How to wire a 220/240 volt Spa... Step by Step details**
    In this video I will show you how I wire a four wire Hot Tub .... two hot wires a neutral/common and a ground This is a step by step video that is very easy to follow with all of the details to help you do it safely
    ********************DISCLAIMER*******************
    Working with electricity can be FATAL
    Not Respecting it can lead to DEATH
    If you don't know what you're doing keep your hands out of the box.
    +++++Please Note Alway shut off the Breaker before You Do Anything+++++
    Wear Safety Glasses and ear Protection
    Take Your Time & be prepared
    Do you want to purchase something seen in this video? Consider checking out my Amazon Associates page and find all of the gear I use + everything used in this video!
    ----------//My Gear\\---------
    GoPro7 Black...amzn.to/3tOI7WH
    128 SD Card...amzn.to/3tRnw4i
    Vivitar VPD-360 Tripod...This Product is very old... Can be found on EBAY
    ---------//Parts\\---------
    Square D Box & 50 Amp GFCI...amzn.to/3xfjrv6
    ---------//Other videos that will help You with Spa/Hot Tub Wiring\\----------
    (1) Wiring a Main to Sub Panel... • How to wire from the M...
    (2) Wiring a Sub Panel... • How to wire a Hot Tub ...
    (3) Wiring a Spa Pack... • How to wire a Hot Tub ...
    --------- // Tony Stark Tool Kit \\---------
    Milwaukee Tester...amzn.to/3wew8DH
    ---------------// LEGAL TALK \\ ------------------------
    I get some funding via your transactions with purchase links with the following affiliate programs.
    Amazon Affiliate.As an Amazon Associate, I earn from qualifying purchases.
    ⚠️DISCLAIMERS:
    FTC: Some of the links above may be affiliate links. If you purchase products with these links, I will receive a small commission at no additional cost to you. Thank you for supporting small creators!
    FTC: This video was not paid for by outside persons or manufacturers. No product was supplied to me for this video.
    As always Thanks for Watchings & SUBSCRIBING.
    How to wire a Hot Tub
    Spa
    Hot Tub
    Wiring
    Subpanel
    electrical
    Balboa
    Jacuzzi
    Spa Repair
    wire spa hot tub
    DIY
    Arizona Hot Tub Factory
    Hot Tub trips Breaker
    wiring GFCI 50 Amp Breaker
    #6 THHN
    four wire Hot Tub
    Spa Heater
    electrical install
    electricity
    Sub Panel
    main Breaker
    wiring a Subpanel

Комментарии • 119

  • @raysharplessjr
    @raysharplessjr Год назад +2

    Great video... Having a spa delivered Wednesday. Feeling much more confident about wiring it up now. Thank you.

  • @734smyth
    @734smyth 2 года назад +2

    Nice job. I am 2 weeks out wiring mine, Thanks......... "Update" Worked out well and got our Hot Tub fired up yesterday. Couldnt have done it without this video. Many Thanks again.............

  • @billjones7817
    @billjones7817 2 года назад

    Thank you for taking the time to make this video. Going to go a long way to save me money... and at a time when every penny counts!

  • @slinville87
    @slinville87 2 года назад

    Great video! I recently did the same install, with a few minor mistakes. I need a couple reduction plates to make sure the GFCI box is sealed and one additional fitting to secure the cabling to the spa power box. Thanks for a great video!

  • @jeanchery7246
    @jeanchery7246 6 месяцев назад

    You absolute 100% great teaching and I will follow you and thanks

  • @billybop17
    @billybop17 Год назад

    Thanks so much for sharing your knowledge.

  • @lumpy19772011
    @lumpy19772011 2 года назад +1

    Very detailed , should make this easy

  • @braggersboard
    @braggersboard 9 месяцев назад

    Great Video!! Thanks for showing step by step in real time!! Makes l it so much better!!!!

  • @erikaanderson8353
    @erikaanderson8353 Год назад +1

    This is an excellent video it made It easy to wire up for my hot tub thank you thank you thank you

  • @roccoelleto9900
    @roccoelleto9900 Год назад

    Fantastic tutorial. Thanks

  • @slantzero
    @slantzero Год назад

    Thank you so much for videos. Very helpful

  • @ronthoman7138
    @ronthoman7138 Год назад

    COOL Man! Thank you for sharing this in such detail. Great content!

  • @tlcraftanddesigns1750
    @tlcraftanddesigns1750 2 года назад +1

    Very informative information…thank you for being so detailed

  • @byronhadley9662
    @byronhadley9662 2 года назад +1

    Good video! Very helpful and it shows everything

  • @solofoto576
    @solofoto576 2 года назад +1

    Thanks for the video 😎

  • @kevinbruch3
    @kevinbruch3 Год назад

    Thanks. Nice job

  • @jessislocum2811
    @jessislocum2811 4 месяца назад

    Great video! Thank you

  • @stevepatterson9605
    @stevepatterson9605 7 месяцев назад

    Excellent video!

  • @hattrick-df4bo
    @hattrick-df4bo 2 года назад

    Nice work!!

  • @jonathansessions2779
    @jonathansessions2779 8 месяцев назад

    great video - thank you!

  • @tonyworkman388
    @tonyworkman388 2 года назад +1

    Good video. Easy to follow.

  • @jortiz1279
    @jortiz1279 4 месяца назад

    great video - will def do our hot tub for sure

  • @Fred_Durst1
    @Fred_Durst1 Год назад

    good job thanks for the video

  • @HolidayForTwo42
    @HolidayForTwo42 2 года назад +1

    Great video, thanks for the info!

  • @sallycebulski9896
    @sallycebulski9896 2 года назад +3

    I never knew it could be so simple! Thanks

  • @johnmoreno7987
    @johnmoreno7987 4 месяца назад

    Thank you so much !!!

  • @edwardhuber7864
    @edwardhuber7864 Год назад

    thanks! big help

  • @alexhandymanservices
    @alexhandymanservices 5 месяцев назад

    Good job 👍

  • @jillworkman3476
    @jillworkman3476 2 года назад +1

    Thanks for your brains!

  • @ericlake6462
    @ericlake6462 Год назад

    Thank you

  • @BULLDOGVII
    @BULLDOGVII Год назад

    Love it!!

  • @user-yk5kt1yo9f
    @user-yk5kt1yo9f 10 месяцев назад

    VERY Nice !!

  • @billking3501
    @billking3501 4 месяца назад

    Excellent

  • @RubenMendoza-q3e
    @RubenMendoza-q3e Месяц назад

    Nice very undenstand tanks good job

  • @generalinfo9999
    @generalinfo9999 Год назад

    Great video

  • @mackenziehadley5818
    @mackenziehadley5818 2 года назад +1

    Great video, very helpful

  • @beantown_bennie6935
    @beantown_bennie6935 8 месяцев назад +2

    Hi. I love your videos! My question os regarding the whole NEC 680.40. The whole within 5’ horizontal of the tub. Mainly the part that states “whith in site.” Even though there is no obstruction does your install, being its cornered comply? I ask because in my state the tub dealer says the within site is only multiple dwellings, yet every electrician says with in site is crucial. Thank you.

  • @mehojasmina
    @mehojasmina Год назад

    How dip under ground pvc goes thanks great video

  • @ericlee2931
    @ericlee2931 2 года назад

    Can I use 6-2 from my indoor panel to feed the spa subpanel? I would attach the bare ground from the 6-2 to the neutral bar in the Spa panel. The tub is 3 wire system

  • @erichgross5840
    @erichgross5840 Год назад

    Thanks for the video. Very helpful. The one thing I don't understand is that in my breaker panel here in California, all the ground and neutral wires are tied together on a common bus bar. Is that okay, and do you have to run both the neutral and the ground to the subpanel where the GFCI is located if this is a common connection anyway? Thanks again!

  • @bthone3366
    @bthone3366 2 года назад

    Great Informative Video!!!!!
    Hey Mr Scott, a quick question, My hot tub will be away from the house and any place to mount my sub panel.Can I have the sub panel, that contains the GFCI 50 Amp Breaker mounted to RIGED conduit coming out of the ground through a 4 inch thick concrete slab about 12 inches above the concrete?The Rigid conduit that the sub panel will be mounted to will be in place when I pour the concrete pad for the tub.The hot tub will be 5 foot from the sub panel box. The main panel to the sub panel will be a 35 foot run with 6 gauge wire.Let me know if this is a proper installation.
    Thanks

  • @eprohoda
    @eprohoda 2 года назад +1

    Good night, tahnk you- awesome ! have a good day-How, 😌

  • @punxnotdead3873
    @punxnotdead3873 Год назад

    Awesome video! Can I hire you to do mine are you in phx?

  • @rveraburgos
    @rveraburgos Год назад +1

    Mr. Scott, I have a couple questions. First, I'm not clear on your statements about sub-panel placement. To summarize, am I correct in saying that the sub-panel must be placed between 5 and 20 feet from the tub, above the TOP edge of the tub, and within line of sight of someone in the tub? The reason I ask is because the installation in your video seems to be both below the tub top, and around the corner from it (out of sight).
    Further, is there generally a code limitation on the length of the Seal/Liquid Tight flexible conduit that can be used? Is that where the 20ft comes from? Does that mean that the flexible conduit section can only be 20ft long (even if the direct distance between the sub-panel and the tub is less than 20ft)?
    Thanks for an informative video and all your help.

  • @theresafernbaugh2136
    @theresafernbaugh2136 Год назад

    So is there no neutral on the spa disconnect if it’s a 3 wire tub?

  • @fiddlerpin
    @fiddlerpin 2 года назад

    Some codes want you to run 6-3 MC cable. Has a ground wire plus a metal covering.

    • @diymrscott4983
      @diymrscott4983  2 года назад

      It will meet CODE... And you will get to meet me if you live in Arizona and start having problems with the breaker tripping and need help as to why... Just because it is code doesn't make it the best choice for a Hot Tub install. Good Luck Thanks for Watching & SUBSCRIBING

  • @timpayne8004
    @timpayne8004 3 месяца назад

    I have a sub panel in my basement that was added for a run to my garage for an EV charger. Is the external box national 'code'? What if I had a gfci in the sub panel and just ran direct to the tub? This seems like a pretty easy run to do the external box either way with flexible whip, but just curious if the NEC has some code requirement since I see hot tub manuals specify that external box. You would be insane to not have a gfci here!!!

  • @jimsymborski613
    @jimsymborski613 Год назад

    Stupid question because I over think these types of situations, but if my hot tub needs 1 dedicated 60 amp and 2 dedicated 40 amp , does that mean I need 3 separate GFCI breakers and 3 separate runs of that 6 AWG wire to an outlet box that will accept 3 inlets for the power and 3 outlets to go back to the tub? I hope this question makes sense.

  • @juliofabrega916
    @juliofabrega916 Год назад

    my spa retrofit has 5 holes: ground, line 1, line 2, neutral 1, neutral 2. My 220V power source only has 4 wires: hot 1, hot 2, neutral and ground. Can you tell me where to connect each one of my wires?

  • @WorkingAxle
    @WorkingAxle 6 месяцев назад +1

    Hey Great video. Very thorough. Quick question: What is the reasoning behind adding a GFCI breaker at the sub panel vs. just using the breaker back at the main panel? Cheers from Chicago

    • @diymrscott4983
      @diymrscott4983  6 месяцев назад +2

      Because the main breaker was so far away and out of sight it is safer to have a disconnect no further then 20 feet and no closer then 5 feet and in the line of sight so as if there is a problem the Hot Tub can be turned off quickly.GFCI is also required by CODE... Thanks for Watching & SUBSCRIBING

    • @WorkingAxle
      @WorkingAxle 6 месяцев назад

      Hey Thanks for the reply! Make sense.@@diymrscott4983

    • @rustbucket77
      @rustbucket77 5 месяцев назад

      You are absolutely correct! Also it is required and a GFI will keep you from getting shock or killed if your heater shorts out. You got 240 volts going to the heating element in the water. I have been installing hot tubs for over 35 years!

  • @scottwinnewisser3255
    @scottwinnewisser3255 Год назад +1

    Great Video. What size conduit you use?

  • @sonora6702
    @sonora6702 Год назад

    Is it ok to run 220 volt wire where theres water from sprinkler system?

  • @wahid8571
    @wahid8571 10 месяцев назад +1

    Hi Scott. Is there a chance to send me the name of parts connection for hot tab Your video is excellent thank you so much.

    • @diymrscott4983
      @diymrscott4983  10 месяцев назад

      I have another YouYube channel called SpaMan that channel has tons of info on it.. Thanks for Watching & SUBSCRIBING

  • @RChobbiespro
    @RChobbiespro Год назад

    1” pvc flex or 3/4”

  • @Dennis47403
    @Dennis47403 Год назад +1

    What is the make/model of the spa disconnect you used?

    • @diymrscott4983
      @diymrscott4983  Год назад

      amzn.to/3xfjrv6 ...Hope this Helps Thanks for Watching & SUBSCRIBING

  • @brunodior8685
    @brunodior8685 Год назад

    Nice screwdriver!!!! Wow 1978 model

  • @davidmatsu9410
    @davidmatsu9410 2 года назад +2

    how do you decide which conduit to use when running the wires? Metal, PVC, Seal Tight?

    • @diymrscott4983
      @diymrscott4983  2 года назад +1

      Great Question... Thanks for Asking, EMT/metal is for above ground from the main panel to the Sub Panel. The PVC is for under ground only and is grey in color so to let anyone know that there are wires in side them if they are digging in the area and uncover them. Seal/Liquid Tight is used from the Sub Panel to the Hot Tub. Now when placing the Sub panel. It should never be placed closer then 5 feet to the hot tub and in line of sight and no lower then the edge of the hot tub and should never be further then 20 feet from the hot tub and as alway should be in the line of sight for safety...Hope this Helps Thanks for Watching & SUBSCRIBING.

    • @davidmatsu9410
      @davidmatsu9410 2 года назад

      @@diymrscott4983 Hello Spa Man, thank you for such a fast response. I have enjoyed watching your videos and ready to do some wiring.

    • @KitchenerLeslie2
      @KitchenerLeslie2 2 года назад +1

      @@diymrscott4983 is the height of the sub panel a personal preference or code? I’ve never heard that, or been told to do that at work.

    • @diymrscott4983
      @diymrscott4983  2 года назад

      @@KitchenerLeslie2 Im not sure if there is a NEC code for the min. height of the sub panel.I can say that over the last 10+ years Ive seen and had inspectors Red tag a job(That I did not install) because of the placement of the Sub/disconnect panel because of height not being a min of of 36 inches to the center of the box as well as being to close to the hot tub. I alway think safety first if the panel is to close to the ground or the hot tub someone could/will use it for a step (bad idea) Hope this Helps Thanks for Watching & SUBSCRIBING

  • @shelhenderson7008
    @shelhenderson7008 Год назад +1

    Do you recommend 2nd hand hot tub dealers. In Wa state?Thank you

    • @diymrscott4983
      @diymrscott4983  Год назад +1

      There is nothing wrong with a second hand hot tub especially with the prices of some new hot tubs.. Do a little checking around before you buy one and buy from someone that will service the product after the sale. I sell more used Hot Tubs in Az then some dealer sell new... I like to keep good used Hot Tubs from ending in the city dump. If you do some research Im quite sure you will find a great deal on a used Hot tub.. Thanks for Watching & SUBSCRIBING

  • @roshanmahavithanage6312
    @roshanmahavithanage6312 5 месяцев назад

    Is the pipe size 3/4?

  • @angelrios6624
    @angelrios6624 2 года назад +1

    Great video . What wire did you use

    • @diymrscott4983
      @diymrscott4983  2 года назад

      I use #6 THHN wire. Thanks for Watching & SUBSCRIBING

  • @travisthompson1896
    @travisthompson1896 Год назад +1

    My hot tub motors pull 46 amps. I have to run 150-200 ft of wire from the panel to the hot tub. Do I need to use 4 gauge wire instead of 6 gauge? Thanks

    • @diymrscott4983
      @diymrscott4983  Год назад

      Yes ....with the Run you are doing being over 150 feet I would use #4 from the main to the Sub..And from the Sub to the hot tub you can use #6 Thanks for Watching & SUBSCRIBING

    • @barleyboy13
      @barleyboy13 4 месяца назад

      ​@@diymrscott4983 My hot tub is similar that pulls 48 amps. If oversizing with a 60amp breaker and a 75ft run would #6 be adequate? My understanding is that 6/3 mc is rated for 75a. This would be run indoors then through wall to spa panel. Thanks!

  • @jaylugo6264
    @jaylugo6264 Год назад +1

    My Sundance requires only 3 wires 2 hot 1 ground from gfci panel the white is capped but my gfci keeps tripping ?

    • @diymrscott4983
      @diymrscott4983  Год назад

      All of the wires need to be connected.(With the breaker off) put the GFCI in the main panel and run all four wires in #6 THHN wire(two hot wires common/neutral and the ground) to a spa disconnect with a 50 Amp breaker and then from the spa disconnect you run the two hot wires and the ground to the spa.Check everything with a volt meter before you connect to the spa. If it still trips its the Spa Hope this Helps Thanks for Watching & SUBSCRIBING

  • @tony2hotty
    @tony2hotty Год назад

    Quick Question - Should a hot tub be filled before or after inspection?

    • @Josh-mk7ok
      @Josh-mk7ok Год назад +1

      It can be filled and used prior to inspection

  • @MAXEDITZ740
    @MAXEDITZ740 Год назад

    What size es tha pvc pipe

  • @treizeepyon5799
    @treizeepyon5799 2 года назад +2

    Is it better or safe to do this yourself or should you hire a pro?

    • @racebumtv8398
      @racebumtv8398 2 года назад +1

      Make sure the breaker is turned off before you start just like he says to do in the vide. I did mine it was easy.

  • @logicflakes8911
    @logicflakes8911 Год назад +1

    Menards sells 6 gauge wire with 2 positive, neutral , ground all in one. Is there a reason I shouldn’t do that? Is buying 4 separate wire cheaper? Sorry if this is a dumb question I’m new to all this thanks!

    • @diymrscott4983
      @diymrscott4983  Год назад +1

      You need to use THHN or THWN wire #6 When you are dealing with a Hot tub.. When ever Ive had to figure out what was causing a hot tub not to run or trip the breaker and everything with the Hot Tub was in great condition and working as it should... it was the wire every time that caused the problem . I can not stress it enough always use THHN or THWN #6 wire on all four wires (two Hot wires Neutral and the Ground) Hope this Helps Thanks for Watching & SUBSCRIBING

    • @logicflakes8911
      @logicflakes8911 Год назад

      @@diymrscott4983 so I can run romex to the sub panel and then THHN from sub panel to spa? I subscribed to both ur channels!

    • @diymrscott4983
      @diymrscott4983  Год назад

      @@logicflakes8911 I never use Romex ever on any install... Like I said above THHN or THWN separate wires only #6 on all four wires. Romex is for inside use only non damp dry use. Romex will cause the breaker to trip. Thanks for Watching & SUBSCRIBING

  • @robot99
    @robot99 2 года назад +3

    Is it necessary to transition from pvc to emt ? Why not go pvc all the way

    • @diymrscott4983
      @diymrscott4983  2 года назад +2

      You should never use PVC above ground as time goes by depending on where you are in the world the PVC will break down over time if it is above ground. Thanks for Watching & SUBSCRIBING

    • @daviedave0915
      @daviedave0915 2 года назад +1

      Bro same goes to emt it rust over time where I am we get alot of rain if anything I use pvc it's in code as long as u use sch 80 I'd rather use sch 80 pvc anyday than emt I wouldn't dare use emt outside I'd use rigid if I don't use pvc

    • @jrod16sports
      @jrod16sports Год назад

      @@daviedave0915 What if you paint the emt?

    • @Josh-mk7ok
      @Josh-mk7ok Год назад +1

      @@daviedave0915 i hook up tubs almost everyday and only use pvc.

  • @pookatkilla4572
    @pookatkilla4572 2 года назад +1

    Did you run a #6 ground as well or a #8? Article 680 is confuuuuuuusing

    • @diymrscott4983
      @diymrscott4983  2 года назад

      Use #6 on all four wires... Others will tell you different but most of the time when we go do service work the wire was the wrong size and cause the problem or it was wired wrong to begin with. Thanks for Watching & SUBSCRIBING

  • @tablespoon888
    @tablespoon888 2 года назад +1

    Can i use 8 wire with th 50 amp breaker?

    • @diymrscott4983
      @diymrscott4983  2 года назад +1

      I would not recommend it. Under sized wire or the wrong type of wire causes a ton of problems with hot tubs. I use # 6 THHN wire on all four wires..Thanks for Watching & SUBSCRIBING

    • @keithharrington8715
      @keithharrington8715 Год назад

      As an electrical guy, I can see where determining wire size is confusing. In the nec, table 310.16 has columns for different temperatures based on the insulation type.
      Most people do not realize that nec 110.14 is for terminal connections, where you hook your wire on the breaker. This section talks about breakers under 100 amps using the 60 degree C column unless the breaker has a different rating on it.
      So, if you breaker is not rated higher or has no temperature limits on it, you are in the 60 degree C column where no. 8. Is rated for 40 amps and no. 6 is rated for 55 amps.
      Be careful out there.

  • @Missin44
    @Missin44 2 года назад +1

    What box did you use?

    • @diymrscott4983
      @diymrscott4983  2 года назад

      This was a Square D box..We get them a HomeDepot most of the time. Thanks for Watching & SUBSCRIBING

  • @mahzadart
    @mahzadart Год назад +1

    Anything about the size of the wire?

    • @diymrscott4983
      @diymrscott4983  11 месяцев назад

      Always use #6 THHN/THWN wire on all four wires.Thanks for Watching & SUBSCRIBING

  • @betfig3804
    @betfig3804 4 месяца назад +1

    Tell me you’re not a licensed electrician without telling me you’re not a licensed electrician

    • @kil018
      @kil018 Месяц назад

      So what are you saying? Elaborate.

  • @betfig3804
    @betfig3804 4 месяца назад

    Your pvc conduit is only like 4” below grade! Too shallow there guy

  • @leo8497
    @leo8497 Год назад +1

    Most people that electricians start with ground. And you out that lock washer in backwards I believe at the tub.

  • @davidszakacs6888
    @davidszakacs6888 Год назад

    It looks as though the homeowner should be more concerned about the peeling paint on his house before he gets a spa.

    • @diymrscott4983
      @diymrscott4983  Год назад

      It an Air BnB that make a ton of money between of location . Thanks for Watching & Subscribing

  • @betfig3804
    @betfig3804 4 месяца назад

    That piece of emt that connects to the panel looks like absolute 🐕 💩. Do you own a level???

  • @skyview13
    @skyview13 4 месяца назад +1

    Definitely not to code

  • @Red8675309666
    @Red8675309666 Год назад

    how do you typically transition from outdoor to attic runs?