sir, can you please do a video on how i can convert my generator from petrol to natural gas, how to adjust it and also tell us if it is more economical to use petrol or gas. jazakAllah khair.
Hi i have an old Dunlite generator 3kva. Can you please tell me how to fix as I have 50 hz frequency when adjust proper rpm but over voltage at 335 volts with a fan plugged in? Do all 4 stroke generator have AVR inside? Also when you took off the plastic housing on alternator section with two screws i have same thing but two big screws in the middle? Can you please tell me what it is? Also if i don't have AVR can i fit a universal type or AVR from another generator? Any reply appreciated! Thumbs up 👍 for your video. Clearly explained! Cheers from Australia!
We have used the ruclips.net/user/postUgkxOTeIs0vv4_9B5hsmnLsk9r930uDQLu_Y for probably 30 hours with our camper and it’s been great! The noise level is really only noticeable when running the AC and other appliances like the microwave, hair dryer, or coffee pot. It’s not huge like other ones and it has wheels so even at 90lbs, I can move it!
Dear sir I am just a learner doing on LearningZone. We all are trying to do something practical and sharing with others so that we all learn in this process. You have also excellent work. I am feeling lucky since I found you! Best Regards,
Hope this video may help in such serious difficult situation. Also I would shoot more videos explaining the AVR and dynamo more in details. The AVR function, schematic diagram and testing I may cover in future videos. I would shoot videos on big engine generator which are common also now a days. So hope these videos will also help to people looking for such subject. Best regards,
Thank you for this! I installed a new avr and was wondering why the voltage doesn't rise as I adjust the rpm. I search in RUclips and found your video.
Great work Jahan in correcting the loose connections and adjusting the voltage regulator. I was wondering too why the pot was so far out of adjustment. You mentioned in a comment below that someone else was there before you. And good idea as a viewer mentioned to check the frequency to ensure that all is well. Keep up the good work!
Yes dear sir you are correct and this was the case. Anyhow it provided a nice experience and good case study what to do if a generator have too much varied voltage beyond standard. The frequency testing would a good idea and I am looking for opportunity to do so. Thanks for liking dear sir. Best regards,
Sir thank you very much I watched your video with great interest and it was terrific the video was excellent and informative please tell us how we can repair this AVR and how we can fix it and what parts are used in the AVR His complete details so I'll be highly obliged with you and thank you very much keep uploading your videos regarding technical knowledge you are perfect and bless with it thank you again Allah Hafiz Sir thank you very much I watch your video with great interest and it was terrific the video was perfect and informative please tell us how we can repair this AVR and how we can fix it and what are the parts used in AVR his complete details so I'll be highly obliged with you and thank you very much keep uploading your videos regarding technical knowledge you are terrific and bless with it thank you again Allah Hafiz
You are very much right sir. This is the purpose of this video and my all videos have the same purpose! I would upload some more videos in future on generators troubleshooting, testing and understanding. Hope they will respond same way. Regards,
I fitted new avr in generator but it gives me 310 volts but after this setting you told in the video it us giving me 270 volts it does not further decreases after it
I want to contact you. we have a problem in SMDO generator ..its not running any water motors on this generator because its not provide electricity power up to 230...
Please I have a lutian 3600 generator The voltage meter is not stable goes front and back when I put the Gen on. Also the light dims and return, that is the light goes 200 to 160 all the times.
Got a question sir. Why does our generator gets damage every time we use our aircon for like 5hrs. Then the next day its not producing voltage or electricity. Our generator is 6.25kva
Hi your videos are great I thought I reach out to you because I know I have a simple problem and maybe you can help me diagnose it with my genrac quietpact 50. I have did a complete service and replaced the carb and springs that connect to the throttle and governor arm. I get power when running maybe about a minute and rare occasion 10-15 mins then it shuts off. I checked the hertz and put it at 60hz. Engine sounds great. However I have noticed at some point I can hear a slight surge for a moment and at that time I can see the hertz go upto 75-90hz then the power shuts off? I measured the voltage to when running at 60 hertz it’s about124-126 when it surges for a second or less it goes up to 160ish. Could this be the excitation breaker causing this problem. During this whole time I never had a large load on the generator just a tv on.
AoA, very much informative video. I have a strange problem with my homage 6.02 kva ATS generator as it drops voltage randomly. Like sometimes it produce 220-230 volts, whereas, in between, it comes to 97, 105, 180, 102, 115 and then again starts the same up and down sequence. What do u think where is the problem Sir? I can send u a video of the same.
Many thanks for this wonderful video. I have a different problem with my 5kva generator ELEMAX SGH7600EX. I live in an off grid area so I need it to charge my batteries whenever it rains. This generator output is 220v 35HZ which is unsuitable for my inverter. I always increase the rpm to get 275v 43HZ then my inverter will accept. I have changed the avr to a new one and even reWinded the Coils to no avail. I need your advice. Thanks.
What do you mean? I should delete this video because you are unable to understand? I'm not stain on Pakistan. Stain is those who are harming Pakistan all the time. Open your eyes and see clearly.
You speak AVR gives 220 volts . But i think AVR regulate the voltage its supplies the fixed voltage to the armature coils so that armature produces fixed magnetic field and when armature rotates the magnetic field cut the stator coil and current is induced in stator and output voltage is drawn out of stator .
You should watch the video again. I explained everything. If I can do calibration for the alternator or generator, minimum I know what you explained in the comment! Also I uploaded another videos on car alternator videos where I explained all concepts in detail. Regards,
@@JahanZeb1976 i just want to know about AVR . How does it look likes in generator big or small. Secondly i know that AVR regulates voltage and gives fixed voltage to armature of generator . AVR increase voltage if coming less from excitation coil and decrease voltage if coming more from excitation coil . It supplies fixed volts on which it is set . Third how AVR fixed volts set ..please explain..
Dear I have same kind of problem as you discussed here. when I start generator at idle position it's show 212 v. But when I put on Load they reduce to 198V. May I adjust AVR setting as adjusted in this Vedio??
That's great that you are thinking to attempt repair on your generator set. Sure you should adjust the voltage of your generator to some higher level like 240V or so on no load. So that when you will load your generator, it may drop to reasonable level like 225V or 220V standard. Hope you will be able to adjust your alternator or generator voltage in the method I have shown here. Also you may watch my recent video on another big generator repair on my channel. Also you may subscribe on my channel and switch on notification so that you will get my new uploads notification. I will upload a few more very interesting videos on such generators in future. Those videos will sure give you a lot of help with your machines. Wish you good luck with your repair and also you may share your repair experience here with us. Best regards,
Loverly job, backup power is back :-D :-D. Looks like a car alternator, but with stator windings for 220-250vac. I hope you checked the voltage with your multimeter, i would not trust the panel meter. I found it odd that the voltage regulator was so far away from the correct voltage, i hope its just because someone played with the setting, and not a faulty stator. If you have a way of measuring the frequency, you can set the engine rpm for the desired power frequency 50/60 cycles, sorry im saying the obvious :-(.
That is great sir. Your understand is very much correct. The AVR settings someone disturbed before me. I corrected it for the perfect voltage setting. I measured the voltage with my fluke and the panel meter was corresponding to that reading. I have a meter measuring frequency. I will try setting that. Your point is very valid and have strong value. I set it so that it works just fine with lamps, induction motors like fans, my laptop charger and other cell phone chargers. I would sure give a try for correct frequency sometime. Best regards and thanks for liking and comment.
Yes yes dear sir there is a problem with the name. This blog post I wrote just today but the name appears is the email user ID name. I don't know the way to change it. I gave this name myself long before due to some reasons which have no more need. But it is OK anyhow. This belongs to me.
dear sir, i am facing some problem when i start the generator on home gas the engine RPM don't constant RPM up and down but on petrol RPM is ok no trouble found. plz suggest.
Check my other video on the same alternator gas kit maintenance and adjustment. Hope your gas kit maintenance and adjustment may solve your gas running problems. Regards,
i have nissan sunny japan 2005,when my car is switch off my brake paddle get too hard direct without pumping,and when i start and or drive my car my paddle sinked too much to the bottom .please advise what to change in my car,and thr is no air contents in brake pip line. please advise thanks.
Dear friend Abdul Khaliq thanks for watching and thanks for sub. Your question have two parts: 1. The hard car brake paddle in any assist brake car during engine stop, is normal. This is in common in any car make and model. So don't worry for that. 2. If your car paddle is going too down close to floor, this is the result of worn out rear brakes or if you replaced brake shoes recently, it is the result of not properly adjusted brakes. So check if your brake shoes are very old, replace them with new and adjust brakes properly. Watch my other videos for rare brakes repair. Replacement of brake shoes and pads are compulsory for you and your car safety. Better check for all four wheels brakes and air bleeding is also a good idea. Please don't hesitate to ask anything anytime. Best regards and wish you good luck with your repairs.
Dear friend jut I uploaded one video on same make but different model car. It will guide you through the details. Also you should read the blog post regarding that video. The blog post address is there in the comment section as well as in the description. Regards,
The AVR takes a sample of main voltage and uses it with exciter winding to give proper excitation to the rotor. if 240 v winding is putting out 250, the avr takes the exciter winding and thru electronix in avr exciter sends a lesser amount of D.C. to brushes to energize the field. if u get 220 instead of rated 240. exciter puts more voltage d.c. to brushes. U got that?
oohhhh that why i get no output power .. well thank you very much .. i will look it up on my generator see if that the problem .. thank you very much for info buddy ..
My generator (1500w) is producing 300v, and under load of 1050w, voltage goes to about 225v. Is that normal ? And how do I fix that ? Are the springs weak ?
Hamare pas 3kv ka genrator hei pehlaly frieg or 6 pankhe aram se chalata tha petrol or gas donon par lekin ab ba mukhil 4 pankhe chalata hei avr bhi new hei voltage bhi 215 tak dey raha hei ??
اس جنیریٹڑ کا انجن اوورہال کر لیں مکمل۔ ہیڈ، والوز، ہیڈ گیس کٹ اور پسٹن رنگز۔ اس کے علاؤہ اگر آپ گیس لائن پر چلاتے ہوں تو گیس کٹ کی بھی مینٹینس کروا لیجیئے۔ ویڈیو میرے چینل پر ہے۔ اگر خود کرنا چاہیں تو۔ چینل لازمی سبسکرائیب کیجیئے۔ شکریہ۔
You can change it by rewinding the generator. The avr could only provide fine tuning of voltage. Other way is use a step up transformer of same VA rating like generator to step up the voltage from 120v to 220v ac.
Sir, I have 3800watts generator with gas kit my generator was producing 150 voltage then i change my avr but now its producing 310 voltage then i tried to decrease voltage but couldn't successful plz help me what should i do? Should i purchase new avr?
+zohaib anwer dear friend seems that you got a faulty avr. Try my method to set up voltage if there is setting potentiometer on the avr. Otherwise go for a new original avr replacement. Regards.
Frequency is a factor of engine speed. You should take care of governer and fuel. It you are running on petrol then tune up your carburetor. If you are running on gas then take care of your gas kit. On gas kit repair and tune up I have a video on my channel. Must watch that. Regards,
Voltage fluctuation ki go reasons hothi hen. Agar ap ka engine speed ziyda vary kar raha ho. Second ap ka voltage regulator kam na kar raha ho ya carbón brush kharab hon ya pher slip rings ki surface kharab ho ya gandi ho tho voltage fluctuation hothi hae.
That's great if you replaced the defective cap. Now you can adjust the avr as I have shown here in this video for the desired 230 or 240V. Wish you good luck with your repair. Regards,
Hello sir .. nice video .. i have 1 kva Sawan generator .. i have the issue of low voltage or no voltage in my generator when i increase the speed of engine the voltage ..upto accurate but when speed down to normal rpm of engine the voltage goes zero it is capacitor base i kva generator .. your help in this regard .. really appreciated .. thanks
I think in such a situation the AVR maybe bad. You should check voltage on carbon brushes at normal RPM when there is Zero power production, if there is no voltage at carbon brushes and then voltage develop at higher rpm and then out put power also develop, Check for AVR input power in both cases. If there is input power to AVR at normal rpm and no out put on brushes, means a bad AVR. You should replace the AVR with another new good known avr. Hope this may solve your problem. I am planning to upload more videos to illustrate this all in video to give full understanding. Keep in touch not to miss anything. Best regards, and don't hesitate to ask anything any time. wishing you good luck with your repair.
nice and new info for me.... in my case the generator which i have its is brush less (Carbunless) and AVR less capacitor base generator ... 700va ... 800watts ... and then all issue will be same as said above .
O I am sorry as I didn't notice that. I never ever worked on that unit but will try to get info about that. I will sure share if I may get some information about that. Maybe that will be useful for someone.
Bracelet alternator voltage drop kar raha ha humne exciter rotor winding kiya tha current to nikal Raha hai chhote motor chala raha hai per 60 horse power nahin 60 horse power chalate he voltage drop kar raha hai ab Kya Karen kuchh tips do
Might want to get a new brush set brushes holder. not being well mounted well will give loose contact and mess up slip rings. seems there is a bad wire in harness, maybe from being twisted to much.
Is ka engine check karen keh us ki speed ziyada oper neechay tho nahi jathi. Agar wo sahee ho tho yeh wala avr replace kar len aur adjust kar lena jaisa thareeqa mae nay bathaya hae. Regards,
Dear subscriber thanks for nice comment. This was a multi turn potentiometer that is why it took many turns to bring the generator output voltage to certain standard voltage range. Sure it works as you saw voltage came to good working level. Best regards,
Plzz give me u r nomber .my generator same problam .i chang corbon brush and avr system bt generator are run bor not power....plzzz help me ..i am waiting
Apnay engine ki fuel supply ko smooth banaye. Kabhi kabhi kharab gas kit ki waja say gas supply engine ko smooth nahi hothi jis ki waja say aisa hotha hae. Gas kit maintenance kay leye meri gas kit wali video dekheye. Second reason speed control governer ka kam na karna hotha hae. Usay check kejeye keh wo apna function sahee say kar raha ho. Apni success yahan share kejeye aur celebrate kejeye. Shukria.
Sub se ehem baat jo batana bhol gaya wo ye k shoru me tu awaz me farq nai ata jes se voltage bhi flactuate nai hoty magar ady ganty bd taqreeban voltage flactuate hona shoru ho jata hai. Ab exact problem keya ho ga .
Dear friend how did you know this is a single turn reheostat? This was not a single turn pot meter instead this was a 138 turns pot meter! That's why 100 turns you saw. Lol. Hope you got the point! Regards,
میرے گھر کا جنریٹر 7 یا 8 گھنٹے بعد سارا موبی آئل پی جاتا ہے۔جب موبی آئل ختم ہو جاتا ہے تو جنریٹر اسٹارٹ نہیں ہوتا۔ دوبارہ سے نیا آئل ڈالنا پڑتا ہے پھر اسٹارٹ ہو جاتا ہے۔ بظاہر جنریٹر بالکل درست کام سر انجام دے رہا ہے 1)جنریٹر موبی آئل کیوں پی جاتا ہے۔ اس کی کیا وجہ ہو سکتی ہے۔؟ 2) جنریٹر کا یہ مسئلہ حل کرنے کے لیئے مجھے کیا کرنے کی ضرورت ہے؟ 3) کیا میں موٹرسائیکل کا استعمال شدہ موبی آئل استعمال کر کے کام چلا سکتا ہوں؟ براہ مہربانی رہنمائی فرمائیں شکریہ۔
It had serious engine defect like wornout rings or defective oil seals on valves and wornout valve guides. All you need to do to overhaul the engine. All these deffects will be addressed in overhauling process. Meanwhile you can use used oil from bike unless it's too much dirty or black.
نہیں جناب۔ سب سیکھ سکتے ہیں اس سے۔ مگر دو باتیں ہیں۔ پہلی یہ کہ لازمی نہیں ہے کہ ہر انگریز کو جیسے انگریزی آتی ہے ویسے ہی اسے ٹیکنالوجی کا بھی پتہ ہو۔ وہ بھی ہماری ویڈیوز سے سیکھتے ہیں۔ دوسری اور اہم بات یہ ہے کہ ہمارے لوگ بھکاری ہیں۔ ان کے پاس نہ تو ویڈیو دیکھنے اور پوری دیکھنے کے لئے ڈیٹا ہوتا ہے نہ ٹائم۔ وہ خواہ مخواہ کے استاد بنتے ہیں اور ویڈیو کو سکیپ کرتے ہیں۔ تو ہمیں کیا ضرورت ہے کہ ایسے لوگوں کو سیکھائیں جنہیں قدر ہی نہیں ہے ۔ بے شک وہ اپنے ہی کیوں نہ ہوں۔ بات تلخ ہے مگر ہے سچی حقیقت۔
Dear and respect viewers must read the blog post associated with this video. This provides extra information about this video. Here is the url for the blog post. diycarmaint.blogspot.com/2017/03/generator-alternator-electrical-repair.html
LearningZone ap.kahan hotay hain
sir, can you please do a video on how i can convert my generator from petrol to natural gas, how to adjust it and also tell us if it is more economical to use petrol or gas. jazakAllah khair.
Hi I need your assistance for fixing generator.
Dear sir salam plz sir show next video have old avr repear
Hi i have an old Dunlite generator 3kva. Can you please tell me how to fix as I have 50 hz frequency when adjust proper rpm but over voltage at 335 volts with a fan plugged in? Do all 4 stroke generator have AVR inside? Also when you took off the plastic housing on alternator section with two screws i have same thing but two big screws in the middle? Can you please tell me what it is? Also if i don't have AVR can i fit a universal type or AVR from another generator? Any reply appreciated! Thumbs up 👍 for your video. Clearly explained! Cheers from Australia!
We have used the ruclips.net/user/postUgkxOTeIs0vv4_9B5hsmnLsk9r930uDQLu_Y for probably 30 hours with our camper and it’s been great! The noise level is really only noticeable when running the AC and other appliances like the microwave, hair dryer, or coffee pot. It’s not huge like other ones and it has wheels so even at 90lbs, I can move it!
I was getting 310V from my generator and I tried this method. Now I am getting 240V. Thanks a lot Sir.
Seems you have a bad avr. Replace with a new one and calibrate. Regards,
How to increase the voltage of a generator from 240v to 415 votls? Using the universal SX460 AVR? Thank you
Great job .. Pray to God to open all doors of success for u now and always
Wonderful and great comment. Your comment and prayers have great value for me. Stay tuned and keep in touch. Best regards.
Thank you very much Sir, I just repaired Mine now with this your Video 👍🤝
That's great. This is the purpose of videos and my channel.
This guy can fix anything!!! Love this guy!
Thank you very much dear Sir for nice words. I am just trying to do little but do it good and am sharing with others. Best regards,
Your knowledge of mechanical systems is amazing. I learn something every time I come here so yes, thumbs up!
Dear sir I am just a learner doing on LearningZone. We all are trying to do something practical and sharing with others so that we all learn in this process. You have also excellent work. I am feeling lucky since I found you! Best Regards,
Thank you very much for the valuable share that is really very good as maintenance of generator is a very serious subject and your videos help a lot.
Hope this video may help in such serious difficult situation. Also I would shoot more videos explaining the AVR and dynamo more in details. The AVR function, schematic diagram and testing I may cover in future videos. I would shoot videos on big engine generator which are common also now a days. So hope these videos will also help to people looking for such subject. Best regards,
Thank you for this! I installed a new avr and was wondering why the voltage doesn't rise as I adjust the rpm. I search in RUclips and found your video.
Great work Jahan in correcting the loose connections and adjusting the voltage regulator. I was wondering too why the pot was so far out of adjustment. You mentioned in a comment below that someone else was there before you. And good idea as a viewer mentioned to check the frequency to ensure that all is well. Keep up the good work!
Yes dear sir you are correct and this was the case. Anyhow it provided a nice experience and good case study what to do if a generator have too much varied voltage beyond standard. The frequency testing would a good idea and I am looking for opportunity to do so. Thanks for liking dear sir. Best regards,
Sir thank you very much I watched your video with great interest and it was terrific the video was excellent and informative please tell us how we can repair this AVR and how we can fix it and what parts are used in the AVR His complete details so I'll be highly obliged with you and thank you very much keep uploading your videos regarding technical knowledge you are perfect and bless with it thank you again Allah Hafiz Sir thank you very much I watch your video with great interest and it was terrific the video was perfect and informative please tell us how we can repair this AVR and how we can fix it and what are the parts used in AVR his complete details so I'll be highly obliged with you and thank you very much keep uploading your videos regarding technical knowledge you are terrific and bless with it thank you again Allah Hafiz
Sure. Will work on AVRs repair and circuit diagram soon. Stay tuned.
You guyz are doing great job.
Thanks. Stay tuned.
Thnx for the video. Ur videos are simple and useful. Keep doing the good work 👍🏻
thank you for this video it was very helpful to understand AVR in small genset
A generator is very much a necessity for a lot of people and needs good maintenance and fault finding .
You are very much right sir. This is the purpose of this video and my all videos have the same purpose! I would upload some more videos in future on generators troubleshooting, testing and understanding. Hope they will respond same way. Regards,
I fitted new avr in generator but it gives me 310 volts but after this setting you told in the video it us giving me 270 volts it does not further decreases after it
I want to contact you. we have a problem in SMDO generator ..its not running any water motors on this generator because its not provide electricity power up to 230...
Great video! I learned a lot with this short instructional video. Fixed my gen set like new!
thank you for your time, it's a very good video.
Thanks for liking and watching. Stay tuned. There is a lot on my channel.
Please I have a lutian 3600 generator
The voltage meter is not stable goes front and back when I put the Gen on.
Also the light dims and return, that is the light goes 200 to 160 all the times.
Got a question sir. Why does our generator gets damage every time we use our aircon for like 5hrs. Then the next day its not producing voltage or electricity. Our generator is 6.25kva
Hi, my 5kva diesel generator suddenly dropped voltage to 120volt.... Any advice on what to do?
Hi your videos are great I thought I reach out to you because I know I have a simple problem and maybe you can help me diagnose it with my genrac quietpact 50. I have did a complete service and replaced the carb and springs that connect to the throttle and governor arm. I get power when running maybe about a minute and rare occasion 10-15 mins then it shuts off. I checked the hertz and put it at 60hz. Engine sounds great. However I have noticed at some point I can hear a slight surge for a moment and at that time I can see the hertz go upto 75-90hz then the power shuts off? I measured the voltage to when running at 60 hertz it’s about124-126 when it surges for a second or less it goes up to 160ish. Could this be the excitation breaker causing this problem. During this whole time I never had a large load on the generator just a tv on.
What is the best generator to run a house?
AoA, very much informative video. I have a strange problem with my homage 6.02 kva ATS generator as it drops voltage randomly. Like sometimes it produce 220-230 volts, whereas, in between, it comes to 97, 105, 180, 102, 115 and then again starts the same up and down sequence. What do u think where is the problem Sir? I can send u a video of the same.
Seems you have a bad AVR. Replace, caliberate and then check. Also check AVR connections for any loose point etc.
I have same problem what fixed it??
Is this method wont damage the generator or overheat the coil?
No. It's a standard procedure. It works.
@@JahanZeb1976 okayy thanks for the video and information...
Many thanks for this wonderful video. I have a different problem with my 5kva generator ELEMAX SGH7600EX. I live in an off grid area so I need it to charge my batteries whenever it rains. This generator output is 220v 35HZ which is unsuitable for my inverter. I always increase the rpm to get 275v 43HZ then my inverter will accept. I have changed the avr to a new one and even reWinded the Coils to no avail. I need your advice.
Thanks.
opened up the back like you said, no wires or electronics, is it possible there up between the motor?
Dear friend then your generator AVR could be located somewhere in the terminal box. Check and do as directed in the video. Best wishes.
My DEK 6500EL doesn't have an AVR in that position. I have a large capacitor (Dianz CBB60) Anyone know where the AVR is located on that machine?
Brother please clear you views because your English is hard info to lessen, you are representing Pakistan 👌👌👌👌
What do you mean? I should delete this video because you are unable to understand? I'm not stain on Pakistan. Stain is those who are harming Pakistan all the time. Open your eyes and see clearly.
Wao!!!!!! Nice video, thank a lot, but the knob of the potentiometer is not visible, hw did we get to d knob in other to make an adjustment?
hello sir,,, can you please help me where to buy an avr?
You speak AVR gives 220 volts . But i think AVR regulate the voltage its supplies the fixed voltage to the armature coils so that armature produces fixed magnetic field and when armature rotates the magnetic field cut the stator coil and current is induced in stator and output voltage is drawn out of stator .
You should watch the video again. I explained everything. If I can do calibration for the alternator or generator, minimum I know what you explained in the comment! Also I uploaded another videos on car alternator videos where I explained all concepts in detail. Regards,
@@JahanZeb1976 i just want to know about AVR . How does it look likes in generator big or small. Secondly i know that AVR regulates voltage and gives fixed voltage to armature of generator . AVR increase voltage if coming less from excitation coil and decrease voltage if coming more from excitation coil . It supplies fixed volts on which it is set . Third how AVR fixed volts set ..please explain..
Whats your email id..i am marine engineer so i am trying to learn about electric part too .
Where do the other four wires go to?
Can the voltage be set to 260 volts
Sometimes my gen produce 90 v , 220 v and sometime 300?? What problem could be???
Dear I have same kind of problem as you discussed here. when I start generator at idle position it's show 212 v. But when I put on Load they reduce to 198V.
May I adjust AVR setting as adjusted in this Vedio??
That's great that you are thinking to attempt repair on your generator set. Sure you should adjust the voltage of your generator to some higher level like 240V or so on no load. So that when you will load your generator, it may drop to reasonable level like 225V or 220V standard. Hope you will be able to adjust your alternator or generator voltage in the method I have shown here. Also you may watch my recent video on another big generator repair on my channel. Also you may subscribe on my channel and switch on notification so that you will get my new uploads notification. I will upload a few more very interesting videos on such generators in future. Those videos will sure give you a lot of help with your machines. Wish you good luck with your repair and also you may share your repair experience here with us. Best regards,
LearningZone okay thanks a lot.
How to fix voltage fluctuations issue plz provide resolution
Thank you for know how
Loverly job, backup power is back :-D :-D.
Looks like a car alternator, but with stator windings for 220-250vac.
I hope you checked the voltage with your multimeter, i would not trust the panel meter.
I found it odd that the voltage regulator was so far away from the correct voltage, i hope its just because someone played with the setting, and not a faulty stator.
If you have a way of measuring the frequency, you can set the engine rpm for the desired power frequency 50/60 cycles, sorry im saying the obvious :-(.
That is great sir. Your understand is very much correct. The AVR settings someone disturbed before me. I corrected it for the perfect voltage setting. I measured the voltage with my fluke and the panel meter was corresponding to that reading. I have a meter measuring frequency. I will try setting that. Your point is very valid and have strong value. I set it so that it works just fine with lamps, induction motors like fans, my laptop charger and other cell phone chargers. I would sure give a try for correct frequency sometime. Best regards and thanks for liking and comment.
Your vlog has a different name to the one originally given on youtube, are you still ok with the youtube name or should i forget that?
Yes yes dear sir there is a problem with the name. This blog post I wrote just today but the name appears is the email user ID name. I don't know the way to change it. I gave this name myself long before due to some reasons which have no more need. But it is OK anyhow. This belongs to me.
Dear sir arshid ali tak to you that plz salo my problem have old avr repear
السلام عليكم... my diesel generator 5kva gives Like 60 volt output.. what is the problem
What would be the problem of my genenrator low voltage supply even if i adjust the settings of the avr?
Governor could be faulty, or need adjusting. Or even fuel pump is worn.
You need a New AVR Kristina.
Kristina, you need a New AVR to get your correct voltage.
Thanks for sharing.
Nice blog 👍
Thank you very much dear friend for liking. Share it with your social media friends. Regards,
Great Bro 👌
dear sir,
i am facing some problem when i start the generator on home gas the engine RPM don't constant RPM up and down but on petrol RPM is ok no trouble found. plz suggest.
Check my other video on the same alternator gas kit maintenance and adjustment. Hope your gas kit maintenance and adjustment may solve your gas running problems. Regards,
i have nissan sunny japan 2005,when my car is switch off my brake paddle get too hard direct without pumping,and when i start and or drive my car my paddle sinked too much to the bottom .please advise what to change in my car,and thr is no air contents in brake pip line. please advise thanks.
Dear friend Abdul Khaliq thanks for watching and thanks for sub. Your question have two parts: 1. The hard car brake paddle in any assist brake car during engine stop, is normal. This is in common in any car make and model. So don't worry for that. 2. If your car paddle is going too down close to floor, this is the result of worn out rear brakes or if you replaced brake shoes recently, it is the result of not properly adjusted brakes. So check if your brake shoes are very old, replace them with new and adjust brakes properly. Watch my other videos for rare brakes repair. Replacement of brake shoes and pads are compulsory for you and your car safety. Better check for all four wheels brakes and air bleeding is also a good idea. Please don't hesitate to ask anything anytime. Best regards and wish you good luck with your repairs.
Thank you very much for positive reply..i will do it on priority basis.pleease send me the link of that video.thanks
Dear friend jut I uploaded one video on same make but different model car. It will guide you through the details. Also you should read the blog post regarding that video. The blog post address is there in the comment section as well as in the description. Regards,
thanks friend
What might be the cause of my generator, it will go back to 160 after working for sometime. The actual volt is 230
change the avr
@@myhomelab thanks I have already done that then later find out that the coil was damaging the avr so I have to change the coil is now working well
Engine oil capacity of this generator sir
The AVR takes a sample of main voltage and uses it with exciter winding to give proper
excitation to the rotor. if 240 v winding is putting out 250, the avr takes the exciter winding
and thru electronix in avr exciter sends a lesser amount of D.C. to brushes to energize
the field. if u get 220 instead of rated 240. exciter puts more voltage d.c. to brushes.
U got that?
oohhhh that why i get no output power .. well thank you very much .. i will look it up on my generator see if that the problem .. thank you very much for info buddy ..
I hope that same will be your problem with your generator. Hope you may get it working.
My generator (1500w) is producing 300v, and under load of 1050w, voltage goes to about 225v. Is that normal ? And how do I fix that ? Are the springs weak ?
Do maintenance and calibration on your generator's AVR. Hope this will correct the voltage issue.
Is your generator a capacitor and diodes or it is AVR?
Please Make a video on how to repair a gasoline generator that is dead when we use it in a portable welding machine. Engine is dead .
Can I reduce the voltage to 110v
My generator 2.5 kw is generation 240 volts but frequency is 41 how to increase the frequency?
Adjust governor and recalibrate voltage ⚡.
@@JahanZeb1976 how can i adjust the governer just increase the idle speed?
Yes there is sort of adjustment to be done to governor to increase engine rpm.
Hamare pas 3kv ka genrator hei pehlaly frieg or 6 pankhe aram se chalata tha petrol or gas donon par lekin ab ba mukhil 4 pankhe chalata hei avr bhi new hei voltage bhi 215 tak dey raha hei ??
اس جنیریٹڑ کا انجن اوورہال کر لیں مکمل۔ ہیڈ، والوز، ہیڈ گیس کٹ اور پسٹن رنگز۔ اس کے علاؤہ اگر آپ گیس لائن پر چلاتے ہوں تو گیس کٹ کی بھی مینٹینس کروا لیجیئے۔ ویڈیو میرے چینل پر ہے۔ اگر خود کرنا چاہیں تو۔ چینل لازمی سبسکرائیب کیجیئے۔ شکریہ۔
@@JahanZeb1976 Shukrya bhai etni jaldi ap nei jawab dia mein try karta hon
Very good video sir,thank you,who do I order a AVR like yours there with? Please let me know.
Thanks for liking. Such avr are available from local market and they are really cheap. You can locate them online also. Regards,
I have 110v generator ... how do I change it to 220 v . Thanks for your time
You can change it by rewinding the generator. The avr could only provide fine tuning of voltage. Other way is use a step up transformer of same VA rating like generator to step up the voltage from 120v to 220v ac.
Or use a transformer and keep the warranty on ur generator..
Thank you dear
you helped me a lot
That's great it my video helped you. The aim of the video is to help in need. Stay tuned and blessed.
Sir, I have 3800watts generator with gas kit my generator was producing 150 voltage then i change my avr but now its producing 310 voltage then i tried to decrease voltage but couldn't successful plz help me what should i do? Should i purchase new avr?
+zohaib anwer dear friend seems that you got a faulty avr. Try my method to set up voltage if there is setting potentiometer on the avr. Otherwise go for a new original avr replacement. Regards.
Thank you so much for your reply.
I have changed my AVR it is working properly and producing 231 volts. thanks again
how to deal with dropping frequency, my generator is not giving 50 Hz, it is dropping to 44 Hz and then shuts down after that..
Frequency is a factor of engine speed. You should take care of governer and fuel. It you are running on petrol then tune up your carburetor. If you are running on gas then take care of your gas kit. On gas kit repair and tune up I have a video on my channel. Must watch that. Regards,
Thanks ever so much.
Hello sir. Voltage flactuation ki aur keya keya wajha ho sakti hai avr kay elawa
Voltage fluctuation ki go reasons hothi hen. Agar ap ka engine speed ziyda vary kar raha ho. Second ap ka voltage regulator kam na kar raha ho ya carbón brush kharab hon ya pher slip rings ki surface kharab ho ya gandi ho tho voltage fluctuation hothi hae.
Salam ! I changed the capacitor of my generator as it was not producing any voltage but after changing it the output voltage is near 400
That's great if you replaced the defective cap. Now you can adjust the avr as I have shown here in this video for the desired 230 or 240V. Wish you good luck with your repair. Regards,
Hello sir in my genrator they short the avr when i installed new one
Change the coil. That is the solution. The coil is damaging the avr
Good instructions, thanks .
Good video, thanks a lot
+mohammed hakumi thank you very much dear friend for liking video. Stay tuned. Best regards,
Thank you!
MashAllah ... Zabardast
Sir avr kic tarha check karty hain ..? Please reply sooner
I have another video on AVR tester here on my channel. Please watch that video.
@@JahanZeb1976 thank You Respectable sir
Sir meray generator ka voltage kabi low kabi increase ho jata ha koi solution
thanking you for the information
Thank you friend for nice comment. Stay tuned as I will upload more videos on generator machines and other stuff here. Regards,
It sounds like your RPMs are too low
Sir you are right but the AVR setting was too away from the actual settings.
My generator send high voltage that effect divert how to solve this issue please reply my generator 1.5 kv
Same caliberation of AVR. If it don't work, replace the AVR with new one.
Nice job.
Sir wonder lecture thank you
Hello sir .. nice video ..
i have 1 kva Sawan generator .. i have the issue of low voltage or no voltage in my generator when i increase the speed of engine the voltage ..upto accurate but when speed down to normal rpm of engine the voltage goes zero it is capacitor base i kva generator .. your help in this regard .. really appreciated ..
thanks
I think in such a situation the AVR maybe bad. You should check voltage on carbon brushes at normal RPM when there is Zero power production, if there is no voltage at carbon brushes and then voltage develop at higher rpm and then out put power also develop, Check for AVR input power in both cases. If there is input power to AVR at normal rpm and no out put on brushes, means a bad AVR. You should replace the AVR with another new good known avr. Hope this may solve your problem. I am planning to upload more videos to illustrate this all in video to give full understanding. Keep in touch not to miss anything. Best regards, and don't hesitate to ask anything any time. wishing you good luck with your repair.
nice and new info for me....
in my case the generator which i have its is brush less (Carbunless) and AVR less capacitor base generator ... 700va ... 800watts ...
and then all issue will be same as said above .
O I am sorry as I didn't notice that. I never ever worked on that unit but will try to get info about that. I will sure share if I may get some information about that. Maybe that will be useful for someone.
Mere paas 3kva ka generator hai wo load nhi lay rha jaisay hi load daltay hai off ho jata hai.plz help
My generator per load lagane se voltage kam hota he.solve the problem
sir can we run refregerator on 3kva china generator? and how we can reduce the sound its sooooo noicy
Bracelet alternator voltage drop kar raha ha humne exciter rotor winding kiya tha current to nikal Raha hai chhote motor chala raha hai per 60 horse power nahin 60 horse power chalate he voltage drop kar raha hai ab Kya Karen kuchh tips do
Yr panel ki setting Batao plz
Plz tell me panel setting.
Which panel?
@@JahanZeb1976
Generator Panel
Might want to get a new brush set brushes holder. not being well mounted well will give loose
contact and mess up slip rings. seems there is a bad wire in harness, maybe from being
twisted to much.
salam bhai hamara janarator may voltage problem hain kabhi light taiz hota hain kabhi kam
Is ka engine check karen keh us ki speed ziyada oper neechay tho nahi jathi. Agar wo sahee ho tho yeh wala avr replace kar len aur adjust kar lena jaisa thareeqa mae nay bathaya hae. Regards,
Check your governor
You did a lot of turns with that screwdriver - but it wworked
Dear subscriber thanks for nice comment. This was a multi turn potentiometer that is why it took many turns to bring the generator output voltage to certain standard voltage range. Sure it works as you saw voltage came to good working level. Best regards,
Great ywr😍
Thank u
You most welcome dear friend. Stay tuned.
Thanku sirrr
Thanks
Plzz give me u r nomber .my generator same problam .i chang corbon brush and avr system bt generator are run bor not power....plzzz help me ..i am waiting
If the power is less and engine comes to diy, you have engine head and piston rings problem. You should check them and replace bad parts.
must have a digital meter on cam so we can see while your adjusting otherwise 8s fake..
It's not fake. It's just a regular calibration proceedure. More videos will come in future. Stay tuned and keep commenting.
good
Engine ki awaz me farq ata tu voltage kam ho jata hai etc.
Apnay engine ki fuel supply ko smooth banaye. Kabhi kabhi kharab gas kit ki waja say gas supply engine ko smooth nahi hothi jis ki waja say aisa hotha hae. Gas kit maintenance kay leye meri gas kit wali video dekheye.
Second reason speed control governer ka kam na karna hotha hae. Usay check kejeye keh wo apna function sahee say kar raha ho. Apni success yahan share kejeye aur celebrate kejeye. Shukria.
Sub se ehem baat jo batana bhol gaya wo ye k shoru me tu awaz me farq nai ata jes se voltage bhi flactuate nai hoty magar ady ganty bd taqreeban voltage flactuate hona shoru ho jata hai. Ab exact problem keya ho ga .
@@dilnawaz7 Exciter ka excitation loose ho Gaya hoga battery say badhayn .diodes may bhi problem ho saktee hai
240 volts is not good for devices, It must be 220 volts.
This is idle voltage output, when we put on load it will dropped to 220 or below as per wattage
LOL you turned a one turn rheostat 100 times....
Dear friend how did you know this is a single turn reheostat? This was not a single turn pot meter instead this was a 138 turns pot meter! That's why 100 turns you saw. Lol. Hope you got the point! Regards,
Actually it's a TYPE 138 28 turn pot, clockwise to increase voltage... 5 mins of research
Eh aquí la nesecidad de aprender ingles
میرے گھر کا جنریٹر 7 یا 8 گھنٹے بعد سارا موبی آئل پی جاتا ہے۔جب موبی آئل ختم ہو جاتا ہے تو جنریٹر اسٹارٹ نہیں ہوتا۔ دوبارہ سے نیا آئل ڈالنا پڑتا ہے پھر اسٹارٹ ہو جاتا ہے۔ بظاہر جنریٹر بالکل درست کام سر انجام دے رہا ہے
1)جنریٹر موبی آئل کیوں پی جاتا ہے۔ اس کی کیا وجہ ہو سکتی ہے۔؟
2) جنریٹر کا یہ مسئلہ حل کرنے کے لیئے مجھے کیا کرنے کی ضرورت ہے؟
3) کیا میں موٹرسائیکل کا استعمال شدہ موبی آئل استعمال کر کے کام چلا سکتا ہوں؟
براہ مہربانی رہنمائی فرمائیں شکریہ۔
It had serious engine defect like wornout rings or defective oil seals on valves and wornout valve guides. All you need to do to overhaul the engine. All these deffects will be addressed in overhauling process. Meanwhile you can use used oil from bike unless it's too much dirty or black.
I wouldnt run that motor without its cooling cover...
Keep it up! Nobody force you to do so.
.جناب آپ نے ویڈیو انگریزوں کو سکھانے کے لیے بنائ ہے کیا
نہیں جناب۔ سب سیکھ سکتے ہیں اس سے۔ مگر دو باتیں ہیں۔ پہلی یہ کہ لازمی نہیں ہے کہ ہر انگریز کو جیسے انگریزی آتی ہے ویسے ہی اسے ٹیکنالوجی کا بھی پتہ ہو۔ وہ بھی ہماری ویڈیوز سے سیکھتے ہیں۔
دوسری اور اہم بات یہ ہے کہ ہمارے لوگ بھکاری ہیں۔ ان کے پاس نہ تو ویڈیو دیکھنے اور پوری دیکھنے کے لئے ڈیٹا ہوتا ہے نہ ٹائم۔ وہ خواہ مخواہ کے استاد بنتے ہیں اور ویڈیو کو سکیپ کرتے ہیں۔ تو ہمیں کیا ضرورت ہے کہ ایسے لوگوں کو سیکھائیں جنہیں قدر ہی نہیں ہے ۔ بے شک وہ اپنے ہی کیوں نہ ہوں۔ بات تلخ ہے مگر ہے سچی حقیقت۔
@@JahanZeb1976 لگے رہیں برادر
Best English wh
Yes. Anything?
Abi angriz me bache agar zeyda taklep hi to Urdu main bolo na
Kam Dekho kam. Bhadway kahen kay