Replacing gate valves in an impossible spot

Поделиться
HTML-код
  • Опубликовано: 11 июн 2024
  • Man this one was hard. Tight spot, bent copper, should have used Uponor from the beginning.
  • ХоббиХобби

Комментарии • 35

  • @DumbCarGuy
    @DumbCarGuy Месяц назад +3

    The rare moments when you wish you owned a 1/2" copper pipe bender.

  • @cineaste1969
    @cineaste1969 Месяц назад +3

    Hey another difficult job made to look easy to you and your buddy Carlos! 👍🏼

  • @Brndnkslr
    @Brndnkslr Месяц назад +2

    Service plumbing at its finest 👍 good work man

  • @Longeno55
    @Longeno55 Месяц назад +2

    You dudes can repair anything.

  • @jimmyhai6840
    @jimmyhai6840 27 дней назад

    Great work! Tough space.

  • @tomdale1313
    @tomdale1313 Месяц назад +2

    another save by Carlos, thxs for sharing...

  • @aaronbaraiya3692
    @aaronbaraiya3692 Месяц назад +2

    Man that some old cool plumbing

  • @tomn4838
    @tomn4838 Месяц назад +2

    I can tell your in a warm climate. All our water main valves (Chicago) are indoors so they don’t freeze. 😊

  • @brianlafleur997
    @brianlafleur997 Месяц назад +1

    Great job 💯💯💯💯. No leaky leaks.

  • @Longeno55
    @Longeno55 Месяц назад +2

    Carlos rocks! 👉🏼

  • @labmanme
    @labmanme Месяц назад +1

    good work

  • @b.powell3480
    @b.powell3480 Месяц назад +2

    I would add unions on each side of the hot and cold water lines, then install ball valves for each line !

  • @matthewg7835
    @matthewg7835 Месяц назад +2

    Nice work in a tough spot… is it worth it to try and repair the old gate valves? Prob easier and faster to put in a better ball valve I’m guessing?

  • @johnlangley6449
    @johnlangley6449 Месяц назад +1

    I would have pulled the toilet as much as I don’t want to 😮

    • @pershingplumbing9007
      @pershingplumbing9007  Месяц назад

      Bruh I had the same thought going thru my head but I like to make things harder for myself

  • @scottmaz4063
    @scottmaz4063 Месяц назад +2

    Unscrew packing nut whole stem comes out then unscrew it.

  • @fredhall4239
    @fredhall4239 Месяц назад

    why put brass swarfe into the hot and cold pipe work to clog ballvalve orfices, when you only had to cut and sweat out fittings and replace, awkward i know but thats why they employ plumbers.

  • @gregtroyplumbing9858
    @gregtroyplumbing9858 27 дней назад

    SHANE AND LOS STRIKE AGAIN DYNAMIC DUO👍🏻😄

  • @aaronbaraiya3692
    @aaronbaraiya3692 Месяц назад +1

    Also how to tell whether to repair a gate valve or to replace it?😊

  • @lv2fish501
    @lv2fish501 Месяц назад

    Weird having the main shutoff outside, easy for anyone to mess with.

  • @theantichrist4267
    @theantichrist4267 Месяц назад

    Wow hotshot , where are the towels to soak up the water ??? Mold is a dangerous thing .

  • @viralporchpirates8314
    @viralporchpirates8314 Месяц назад +1

    Propress on soft copper…… some people’s children…..

    • @pershingplumbing9007
      @pershingplumbing9007  Месяц назад +2

      It's not soft copper, it was bent type l and propress can be used on type k. I've seen it done several times, I've never done it but have personally seen it done

  • @randybeaumier
    @randybeaumier Месяц назад

    Transition to Pex or push on connectors.

  • @JamesBrown-db9pk
    @JamesBrown-db9pk Месяц назад +1

    use 2 45s

    • @pershingplumbing9007
      @pershingplumbing9007  Месяц назад +2

      Didn't have any but would have used a 45 and st 45 would have made the cold work probably

  • @Inmyopinion10101
    @Inmyopinion10101 Месяц назад

    Should at least catch the dripping water in a tray.

    • @pershingplumbing9007
      @pershingplumbing9007  Месяц назад

      It's concrete pal, not gonna hurt anything and the space was very tight