How to wire a room stat

Поделиться
HTML-код
  • Опубликовано: 4 дек 2024

Комментарии • 36

  • @abdulh63
    @abdulh63 3 года назад +1

    loving the channel! the way you show the diagrams and explain is so easy to understand, many thanks

  • @barriepugh9964
    @barriepugh9964 6 дней назад +1

    Thanks for the vid, I was struggling with the thermostat programmable

  • @morawapiotr
    @morawapiotr 7 месяцев назад +2

    Finally someone explained it clearly. Thanks 💪🏻💪🏻💪🏻🤜🏻🤛🏻

  • @sunkat76
    @sunkat76 Месяц назад +1

    How to Wire a room Stat - step by step with diagrams, thank you!

  • @macpatel7810
    @macpatel7810 3 года назад +1

    Nice and simple explanation.. 👌

  • @jamesparry175
    @jamesparry175 3 года назад +1

    Seen this on you're insta, glad you uploaded on here so can use in future, great video again thank you mate 👌👍

  • @jackhoskins722
    @jackhoskins722 3 года назад +1

    Great video and explanation

  • @timothymay9045
    @timothymay9045 3 года назад +1

    Great explanation

  • @Razz60
    @Razz60 3 года назад +1

    Really helpful bro thank you

  • @heywoodable
    @heywoodable Год назад +1

    Brilliant video

  • @BNapoletani
    @BNapoletani Год назад +1

    Great help. Thanks.

  • @adnaneboukerboub9930
    @adnaneboukerboub9930 2 года назад +1

    Thank you for sharing .. very healpful

  • @davidcoles4826
    @davidcoles4826 4 месяца назад +1

    Awesome
    Thanks bro 🥳🤩

  • @patrickwalkington7512
    @patrickwalkington7512 9 месяцев назад +1

    This makes it easy to understand, but I'm still confused with my wired stat which I need to bridge to be permanently on so my TADO can take over. My wired stat has a LIVE, a SATISFY and a DEMAND - which do I need to bridge to make it permanently on? It's a STT RSL. Thanks, Pat.

    • @cputilitysolutions
      @cputilitysolutions  9 месяцев назад +1

      Tado says it all unfortunately, I've not had much success with it and neither have many customers I know as well. It needs looking at with experience in heating wiring

    • @patrickwalkington7512
      @patrickwalkington7512 9 месяцев назад +1

      @@cputilitysolutions - Cheers. It's the one thing TADO are very vague about! Keep up the good work. Pat.

  •  6 месяцев назад +1

    Thanks. When dealing with low voltage switching should i have separate cables for high and low voltage wires?

    • @cputilitysolutions
      @cputilitysolutions  6 месяцев назад +2

      I've been advised to do so 👍🏾

    •  6 месяцев назад +1

      Thanks! Also is 1.5mm thick wiring sufficient in Ireland for programmers?

    • @cputilitysolutions
      @cputilitysolutions  6 месяцев назад +2

      Yeah I use 0.75mm for controls anyway

  • @Razz60
    @Razz60 3 года назад +1

    Can you do a wiring on S plan 2 zones or how to add 3 or 4 zones

  • @darrenclarke161
    @darrenclarke161 3 года назад +1

    Thanks 👍

  • @reliabill87
    @reliabill87 3 года назад +1

    Can you do this video again but with tbr physical items, especially system boilers
    E. G. Thermostat, zone valves, programmer, etc.

  • @johnkeys368
    @johnkeys368 Год назад

    Well done

  • @Smokeblow
    @Smokeblow 2 года назад

    Thanks 🙏