MOTOR EFFICIENCY: What about the power factor?

Поделиться
HTML-код
  • Опубликовано: 3 июл 2024
  • Motors are inductors so we need to account for power factor.
    If you need help with electrical math check out:
    www.bcit.ca/telc0015

Комментарии • 21

  • @diegolbasilio
    @diegolbasilio 2 года назад +6

    Great video! However It's important to clarify that the current calculation considers a single phase motor. You need to multiply the voltage by √3 for 3 phase motors.
    Single phase: A = 1000 ⋅ kVA / V
    Three phase: A = 1000 ⋅ kVA / (√3 × V)

  • @celenysaurusrex
    @celenysaurusrex 3 года назад

    This was a good video for a quick refresh :) Thanks!

  • @abo000Saad
    @abo000Saad 3 года назад

    Thank you, now the calculation makes sense

  • @jesusespeleta617
    @jesusespeleta617 3 года назад +2

    Just a little correction on your triangle. Power factor is the cos(theta) of the angle (we call theta) you have labeled as 0.7. 0.7 (the power factor) is the result of that calculation, not the angle itself. Just a little clarification, since you can’t work out the equations otherwise. Thanks for the video!

    • @XIAO579
      @XIAO579 2 года назад

      you are right. should be cos-1 70 in order to get the angle.

  • @cobbysparks9891
    @cobbysparks9891 Год назад

    Thanks for sharing. I wanted to draw attention to one thing.
    In your calculation you basically applied the power factor to the Power output by dividing the power output by the pf.
    While mathematically the end result will be the same, I think it is important to recognize that theoretically the pf is more like a ‘knockdown’ of the electrical input power rather.
    That means, strictly from the engineering point of view and dir the purposes of understanding, we ought to multiply the input power rather by pf rather than dividing the output by the pf.

  • @fuellessgenerator6893
    @fuellessgenerator6893 2 года назад

    Good morning, I have a VFD in which three phase induction motor is attached to and I have a capacitor bank to correct power factor lag. I want to know if it's a good idea to implement both power factor correction and a VFD?

  • @boscovigil3223
    @boscovigil3223 Год назад

    Thank you for the clarification. So if you measure each phase of this motor at fully loaded conditions the reading will be approximately 59.2 amps correct?

  • @mohamadkalaji4791
    @mohamadkalaji4791 2 года назад

    thank you for the video.
    Nice IKEA Chair, I have one at home. I am from the UAE

  • @citysnap6136
    @citysnap6136 2 года назад

    Would like to know the PF for a VFD driven Induction Motor

  • @alikaampo9370
    @alikaampo9370 3 года назад

    Thanks for your tutorial it is very helpful, if there is no info about the motor how can find efficiency, voltage source current resistance power voltage required Vin Vout, maximum and minimum voltage and so on.
    Can you help us please.
    Many thanks

  • @mattt5320
    @mattt5320 3 года назад

    An induction motor has 40kVA input power, a power factor of 82 percent, and an efficiency of 92 percent. What is the horsepower?
    How do you solve this?

  • @cipcap5324
    @cipcap5324 6 месяцев назад

    H0w can I take this course? I'm currently at
    SOROHT SHAW

  • @calholli
    @calholli 3 месяца назад

    7460w / 240v = 31amps .. vs your calculated 59.2amps
    Is this motor really wasting 28 amps ... That seems pretty extreme. So in this case, the electric company would be charging you nearly double the power that you're actually using. Is this common? Or is this example a particularly bad efficiency?

  • @surferpaul420
    @surferpaul420 2 года назад

    But with all due respect, it was very helpful. Thank you.

  • @ivancazessus3133
    @ivancazessus3133 3 года назад +1

    Can’t you just look at the name plate and look for the FLA to get the current ?

    • @TheElectricAcademy
      @TheElectricAcademy  3 года назад +4

      Yup but when you’re in school they ask stuff like this.

  • @frnks3020
    @frnks3020 2 года назад

    The coffee peace was so pointless lol

  • @charlesa7772
    @charlesa7772 2 года назад

    VA= V•I•√3

  • @cazkelly
    @cazkelly 2 года назад

    Switching to facecam is no bueno

  • @surferpaul420
    @surferpaul420 2 года назад

    I really wish you would shorten your intro and get to the point. People are on RUclips so that they can cut the crap and get the info they need.