Where does the Reactive Power go? TheElectricalGuy

Поделиться
HTML-код
  • Опубликовано: 28 апр 2020
  • In many cases, reactive power generated by a system is more than what it needs! The question is where is this additional reactive power going? Confused? Well in this video we are going to discuss about where does this reactive power go in details. So, to know about it more you need to watch the video.
    #ReactivePower #PowerSystem #Electrical
    Videos You May Like :
    Active, Reactive & Apparent Power - • Active, Reactive & App...
    Active power Vs Reactive Power - • Difference Between Act...
    Voltage Vs EMF - • Voltage or Potential d...
    AC Vs DS - • Alternating Current (A...
    ---------------------------
    For more interesting videos & articles about electrical engineering visit - www.theelectricalguy.in
    Find me:
    Facebook - / iamtheelectricalguy
    Instagram - / the_electricalguy
    Twitter - / delectricalguy
    RUclips - / gauravj
    Created By : Gaurav J

Комментарии • 181

  • @tedlahm5740
    @tedlahm5740 4 года назад +13

    Sir: Just as wonderful the second time watching this video.

  • @kilura1
    @kilura1 3 года назад +28

    To make it even more easier to understand. Reactive power is never produced or consumed, we just say this for our convenience to describe whether load is more like inductor or more like capacitor.
    Reactive power is just fluctuation of energy in form of electric or magnetic fields. When you apply voltage to inductor, it creates a magnetic field. Creating magnetic field consumes electrical energy. When you remove voltage, magnetic field of inductor dissipates back into electrical energy. Same thing with capacitor, but in capacitor electrical field is created. So in 60Hz sinewave circuit capacitors and inductors create and dissipate electric and magnetic fields 60 times per second. Just like pouring water from glass to glass.
    The main reason why we are interested in reactive power is the fact that reactive power creates current in wires, which heats up this wires, melt wires, trip breakers etc.
    Sorry for bad english:)

    • @a-learnerforever
      @a-learnerforever 2 года назад +9

      This is it. What you have just said is not known to most of the people who create educational videos like that. He said that the capacitor sends power to the system, but this is not fairly true. In a given period of time, it both takes energy and sends energy to the system, so the inductor does the same. When they are put together, they do the transaction with each other, so they don't send the energy back to the system and don't cause the unnecessary power fluctuation.
      I imagine the fluctuation is like breathing. Your example of pouring water from glass to glass is far more understandable. I just want to thank you so much for this comment. I have thought about this for a long time and watched videos about it, but none of them gave me what I needed. Thank you. My English is bad too. Sorry for that.

    • @sm-ph8uf
      @sm-ph8uf Год назад

      thi is true explaination

    • @bahaagamal4995
      @bahaagamal4995 10 месяцев назад +1

      Thank you very much for this word ( Reactive power is never produced or consumed, it is just fluctuation of energy in form of electric or magnetic fields) ....solved all my thinking problems.

    • @bernardocisneros4402
      @bernardocisneros4402 7 месяцев назад

      Very good and conscise explanation.

    • @funfun8262
      @funfun8262 2 месяца назад

      So kind of you to explain the concept, regards and thanks.

  • @rishabbhattacharya190
    @rishabbhattacharya190 4 года назад +4

    sir, thanks for clearing such a complex concept.

  • @yarrammahendra4957
    @yarrammahendra4957 4 года назад +7

    U r explanation is very clear ,thank u for making this vedio

  • @tedlahm5740
    @tedlahm5740 4 года назад +3

    Fantastic information. Thank you.

  • @ansar3139
    @ansar3139 3 года назад +1

    Very well explained! many thanks indeed.

  • @mayankgautam6527
    @mayankgautam6527 2 года назад +1

    Feels like learning something useful that is really present in the real world, while watching these videos. Thank you sir for such amazing explanations.

  • @shubhankarmaitra4231
    @shubhankarmaitra4231 2 года назад

    thank you so much. i have a great belief on your knowledge and for this i search your videos for any problems solution related on electrical.

  • @habt-tube
    @habt-tube 3 года назад +2

    I can say all your tutorials are very useful. You are not only genius but also born to teach. Keep up your good work genius.

    • @GauravJ
      @GauravJ  3 года назад +1

      Thank You 😊 Do share and subscribe to my channel ✌🏻👍

  • @mohsinanwar4404
    @mohsinanwar4404 3 года назад +1

    Very informative you clear my concept so.very thanks

  • @engburreali9019
    @engburreali9019 4 года назад +4

    Full respect sir 🙏 absolutely you are a good explainer and I like people such like this ❤️

  • @sadeghahmadi5074
    @sadeghahmadi5074 3 года назад +3

    all of your videoes explain the confused problems very simple. thank you so much

    • @GauravJ
      @GauravJ  3 года назад

      You are welcome 😇🙏🏻

  • @hemanthrayagiri5807
    @hemanthrayagiri5807 3 года назад +1

    Sir your explanation is awesome👏

  • @kabandajamir9844
    @kabandajamir9844 2 года назад +1

    The world's best teacher thanks

  • @zainulkhan881
    @zainulkhan881 4 года назад +4

    u r a good explainer👍
    Advice: u should try with KVAR digital meter with connection & show the reactive power on meter display to us

  • @mohammadpathan4668
    @mohammadpathan4668 4 года назад +1

    Nice explanation !

  • @agniveshkadiyala8185
    @agniveshkadiyala8185 3 года назад +1

    Great explanation

  • @user-pm3dk5eb9o
    @user-pm3dk5eb9o 4 года назад +12

    How transformer or induction motor will use kVAR to produce magnetic field?please elaborate this phenomenon?

  • @noorulahad4061
    @noorulahad4061 3 года назад +1

    Thank you sir.

  • @sumit-07
    @sumit-07 Год назад +1

    What an explanation sir ji 🙇🏻❤️

  • @Krishna-qm5qk
    @Krishna-qm5qk 4 года назад

    I clearly understood but I would like to know in which condition shunt reactor would add in our line and will it consume or deliver back the reactive power.

  • @laxminarayanlala6850
    @laxminarayanlala6850 4 года назад +3

    Thank u bud ❤

  • @TV-dv2qd
    @TV-dv2qd 3 года назад +1

    Thank you sir !

  • @shafqatkizim6899
    @shafqatkizim6899 10 месяцев назад +1

    Great explanation sir

  • @BestMathsTeacher
    @BestMathsTeacher 10 месяцев назад

    Is it good to compensate reactive power from synchronous generator? Is it economically good to compensate reactive power of power system from synchronous generators only or by using the capacitor banks?

  • @tubarekolah1786
    @tubarekolah1786 3 года назад +1

    Thanks a lot for these clear and concise explanations. Well appreciated

    • @GauravJ
      @GauravJ  3 года назад

      Thank you 😊 Do subscribe to my channel and share the video ✌🏻🙏

  • @Concefacts
    @Concefacts 3 года назад +1

    You forgot to trim one line of one capacitor "C" in the PowerPoint. See at 4:45.
    By the way, you are so hardworking, I know how much effort we have to do for such simple graphical representation and animation. Good work keep it up :)

  • @smithjeba
    @smithjeba Год назад

    Thanks for the explanation - Please post more videos on Power Quality Improvement (SVC, STATCOM, FACTS) - Also more on HVDC System (all course, I need from the basic concepts)

  • @arzunmondal6336
    @arzunmondal6336 3 года назад +2

    Your video is just awasome sir........♥️♥️

  • @phils4634
    @phils4634 3 года назад +9

    The problems of effectively managing reactive power in transmission systems are significant, and add to the capital expenditure. This is one of the reasons why EHV DC lines are very attractive, especially for power transmission over longer distances, where inrush / charging losses and other line losses start to mount up. Also, effective management of long lines is a non-trivial exercise, and, although the switching / protection requirements of EHV DC are greater, this added cost is offset by reduced line losses, no need for VAR management, and the not insignificant problem of accurate phase matching, especially over long distance lines. For long distance, bulk transmission, I suspect DC may well be the future.

    • @maryvictoriasmith3035
      @maryvictoriasmith3035 3 года назад

      Why do people want to cook my daughter and myself ? We did nothing to anyone... Both of our thyroids are fried.

  • @Smileplease349
    @Smileplease349 4 года назад +2

    Hello sir..!!! My question is not related to this video but I m very much confused in Merz Price protection and percentage differential protection, I know the basic principles but hard to understand what is difference between two....As in where we use Merz protection and where we use differential protection.
    Pls help me out.

  • @shubhamkiranbadgujar1443
    @shubhamkiranbadgujar1443 3 года назад +1

    Wow thank you so much , sir can you tell us what’s a Mmf and how it’s forces to move flux

  • @rinkeetiwari490
    @rinkeetiwari490 4 месяца назад +1

    Very informative and well explained !!

    • @GauravJ
      @GauravJ  4 месяца назад

      glad it was helpful

  • @arun4846
    @arun4846 2 года назад

    Superb

  • @sa1971
    @sa1971 2 года назад

    Do The incoming Active power and outgoing Reactive power passes through different wire?

  • @udoetteedidiong1842
    @udoetteedidiong1842 8 месяцев назад

    I want to ask why we don't have phase current display on the generator when a Turbine is on Part load Operation, but Will show when it on Grid Operation

  • @donberg01
    @donberg01 Год назад

    Could you talk about grid stability, rotor angle vs rotating magnetic field angle, synchronous generator vs induction generator please! Thank-you!

  • @AdeyemiAlabi
    @AdeyemiAlabi 4 года назад +1

    @Gaurav J - TheElectricalGuy I so am learning a lot following your videos thank you so much for them. I just keep having questions.
    so what will be the power factor of the system in the example you discussed? i would have said 1, but then the apparent power isn't equal to the real power and so despite the fact that the generator only supplies real power. So my guess will be that the power factor will be 91.2% since pf is real power/apparent power. Kindly let me know if I am right.
    also, in the example you explained here, what if the capacitor C that generates 20KVAR of reactive power were to be damaged, what happens in that case? the system becomes short of 11KVAR of reactive power and will draw the reactive power from the Generator. if you had sized the line from the generator based on the apparent power when the capacitor worked, wouldn't that be a problem? since the new apparent power will be more. and hence the current flowing through the line will be more. I wonder if I am just thinking rubbish but I wish you can explain if I wrong.

  • @vinodhambarde2857
    @vinodhambarde2857 Год назад +1

    Sir, really feels learning something different. Thank u for explaining in in a simple way.

    • @GauravJ
      @GauravJ  Год назад

      Thank you 😊 do share and subscribe 😇

  • @GeraltOfRivia69
    @GeraltOfRivia69 3 года назад

    Sir,Please correct me if I'm wrong(probably), so if I have more capacitive load and my neighbor has more inductive load, so extra reactive power produced my me will be consumed by the inductive load of my neighbor, in turn improving the power factor for both of us?? Is this analogy any good?

  • @sanamtalpur-jw7zh
    @sanamtalpur-jw7zh Год назад +1

    Best explanation ever 🎉

    • @GauravJ
      @GauravJ  Год назад

      Thank you 😊 do share and subscribe

  • @vijaykumarkumar2498
    @vijaykumarkumar2498 7 месяцев назад

    In case of single phase supply (its having positive and negative conductors only) how the reactive power will flows back,in negative conductor or positive conductor please tell me sir!

  • @ssh6943
    @ssh6943 4 года назад

    Is there any relation between reactive power and Harmonics?

  • @jijovarghese1987
    @jijovarghese1987 3 года назад +1

    In other words we can say that negative sign in KVAR indicates that capacitor is delivering lagging reactive power.

  • @muthum5817
    @muthum5817 2 года назад

    How use capacitor in single phase motor

  • @rushikeshpulate5120
    @rushikeshpulate5120 4 года назад +1

    Sir please tell me overall effects of reactive power in a system

  • @jonathansera6134
    @jonathansera6134 4 года назад

    Great video, well made and very clear. What type of power outlet is that at 2:05? Looks like either a type D, M, or O, but what are those two extra holes at the bottom of each outlet for? Metering?

    • @GauravJ
      @GauravJ  4 года назад

      Hi Jonathan Sera !
      Thanks for the compliment 😇
      The extra two holes at the bottom are Phase and Neutral only. That’s a alternative socket provided in case if the plug 🔌 is not getting fitted in the first two holes.

  • @anuragmishra4555
    @anuragmishra4555 11 месяцев назад

    Is it sure that the kvar generated at the load will be totally ( absorbed) balanced by the transformers, motors and relays connected in lines.
    Is it possible that kvar generated is 11kvar and kvar absorbed by transformers=4 kvar
    ,Motors =2 kvar and miscellaneous (relays, lins inductance) = 2 kvar
    Then what will happen to remaining 4 kvar
    (If There is no more inductive loads in line except the above mentioned)

  • @iareid8255
    @iareid8255 3 года назад

    PS, your 12 KVAR motor also rated at 12 Kwatt is running at unity, very unusual unless it is a synchronous motor?

  • @Rizki-vz6hw
    @Rizki-vz6hw Год назад

    thank you for this video. I have a little bit question. In the generator, when I want to increase the VAR, will the Watt also increased?

    • @bernardocisneros4402
      @bernardocisneros4402 Год назад

      Increasing VAR will only increase apparent power. Active power (true power) will stay the same, but power factor will go down because P.F. is the ratio of true power to apparent power.

  • @mikeall7012
    @mikeall7012 3 года назад +1

    There are still quite a few mechanical relays used in generation and distribution infrastructure, in North America.

  • @CharlieTechie
    @CharlieTechie Год назад +1

    Great explanation once again Gaurav!.

    • @GauravJ
      @GauravJ  Год назад

      Thank you ☺️

  • @desi_yatrie
    @desi_yatrie Год назад +1

    great

  • @jameulrafi5827
    @jameulrafi5827 Год назад

    I have a doubt,,
    In your previous video you said ,when power flows load to source we call it reactive power..then how it could be reactive power consumed by inductor as it's flowing source to load ..
    Plz sir reply 🙏

  • @gamingworldofAbdullah_8787
    @gamingworldofAbdullah_8787 2 года назад

    Dear Sir, I am working in Substation project. Kindly share a Video on bus-bar, line and transformers protection.

  • @ahmedtayeh7467
    @ahmedtayeh7467 3 года назад

    Thank you very much for this. I just don't understand how can power flow in two direction on the same line, would you please explain how this happens?

    • @aaronoyler6830
      @aaronoyler6830 Год назад

      Because electricity doesn’t actually flow through wire the way water does through pipes. Electricity actually flows around the wire in an electromagnetic field. What the video is explaining is the two fields are bouncing into each other disrupting the current. Like a mosh pit of electrons.

  • @EEECampus
    @EEECampus Год назад

    Very very informative discussion thanks a lot.

    • @GauravJ
      @GauravJ  Год назад +1

      Do also check out my other videos 😊

    • @EEECampus
      @EEECampus Год назад

      @@GauravJ Yes I do thanks.

  • @aabhamodi1018
    @aabhamodi1018 3 года назад

    Sir plzzz make videos becoz u r best teacher for electrical so plzz more nd more videos sir plzzz plzz make on the topic of generator motor transformer

  • @onpurpose2629
    @onpurpose2629 2 года назад

    Explain power from solar plants? Reactive or capacitive effect to voltage / current relationship? Power factor?

  • @garodantada9526
    @garodantada9526 3 года назад +2

    Nice

  • @aftabraj1865
    @aftabraj1865 4 года назад +1

    Good

  • @williewilson8244
    @williewilson8244 2 месяца назад

    Why would generation stations run generators for power factor correction. Instead of generating power they pull load from the supply lines?

  • @marwatsconfessionabouteduc3794
    @marwatsconfessionabouteduc3794 3 года назад

    Sir which application your are using to creat such content.??
    Your students want to know.

  • @laxminarayanlala6850
    @laxminarayanlala6850 4 года назад

    If time allows then Please make a video about LC oscillator , under damped oscillator & over damped oscillator.

  • @illusion4664
    @illusion4664 Год назад

    love you bro

  • @wanderer_Aviee
    @wanderer_Aviee Год назад

    sir if we consider a pure resistive load on the entire power system, that means no reactive power is delivered back to the source in that case what happens to the connected transformers, motors how it will create magnetic field.

  • @AK-xp6mm
    @AK-xp6mm 3 года назад

    Hi Gaurav
    In good books I saw that author use words like supplying leading vars ,absorbing leading vars , supplying lagging vars , absorbing lagging vars.
    These words are used when synchronous motor is connected to bus bar to improve power factor.
    Can you clear me meaning of these words by making video.
    Thanking u in advance.

  • @prajwalmhaske10
    @prajwalmhaske10 3 года назад

    Sir Can you please make a video on complex power

  • @saurabhthombare5223
    @saurabhthombare5223 11 месяцев назад

    Sir in this example capacitive load is more than inductive load but sir what will happen if inductive load is greater than capacitive load

  • @mailtosabarajan
    @mailtosabarajan 4 года назад

    May I know why have added 12kvar(M) in to the active power consumption?

    • @GauravJ
      @GauravJ  4 года назад +1

      Motor consumes both active and reactive power. In our example motor is consuming 12kW active power and 12kVAR reactive power as well.

  • @vforvreak8895
    @vforvreak8895 3 года назад +2

    Really nice video as most of them :). Regarding 8:45 - 9:30 when talking about "where the reactive power goes": considering a 50Hz grid I understand that the reactive won't be able to go "that far", right? Because the voltage back and forth and the speed of electrons won't let it travel too far away.

    • @GauravJ
      @GauravJ  3 года назад

      True that!

    • @harshshah6937
      @harshshah6937 2 года назад

      @@GauravJ when we say lagging vars absorbed by the load in the other words we say leading vars supplied by load how we say leading vars supplied by load ?

    • @harshshah6937
      @harshshah6937 2 года назад

      @@GauravJ sir say true if in the transmission conductor through which active power and reactive power flow together in either opposite or same direction at same time, sir pls reply?

  • @sumanbasnet7481
    @sumanbasnet7481 3 года назад +5

    I wana know physics behind "how two powers can flow in two different direction at same time through same line?"

    • @aamirawan7998
      @aamirawan7998 2 года назад +1

      It doesn't happen. The negative sign simply shows that current is leading the voltage. Reactive power is nothing but a phase shift between voltage and current. If the current leads the voltage we put a - sign to Q and if it lags the voltage we put a + sign. This is done to simplify the equations and calculations.

  • @FonsecaEugene
    @FonsecaEugene 3 года назад

    What if we have net remaining reactive power

  • @lalitjoshi7152
    @lalitjoshi7152 2 года назад +1

    Sir...Your graphics are too clam and cool to understand and make perfect image of system..
    Thankyou...
    New subscriber (new student)

    • @GauravJ
      @GauravJ  2 года назад +1

      Thanks and welcome 🤗 do share my channel with your friends

    • @lalitjoshi7152
      @lalitjoshi7152 2 года назад

      @@GauravJ sure

  • @enamulhaque630
    @enamulhaque630 4 года назад +5

    I have similar another question once fault occurs where does this huge fault current go. Please also make a video on it

    • @GauravJ
      @GauravJ  4 года назад

      Sure. I’ll try to post video on it !

    • @enamulhaque630
      @enamulhaque630 4 года назад +1

      and one more question what are the source of such huge current

    • @AdeyemiAlabi
      @AdeyemiAlabi 4 года назад +1

      @@GauravJ I so am learning a lot following your videos thank you so much for them. I just keep having questions.
      so what will be the power factor of the system in the example you discussed? i would have said 1, but then the apparent power isn't equal to the real power and so despite the fact that the generator only supplies real power. So my guess will be that the power factor will be 91.2% since pf is real power/apparent power. Kindly let me know if I am right.
      also, in the example you explained here, what if the capacitor C that generates 20KVAR of reactive power were to be damaged, what happens in that case? the system becomes short of 11KVAR of reactive power and will draw the reactive power from the Generator. if you had sized the line from the generator based on the apparent power when the capacitor worked, wouldn't that be a problem? since the new apparent power will be more. and hence the current flowing through the line will be more. I wonder if I am just thinking rubbish but I wish you can explain if I wrong.

  • @habeebrahman1518
    @habeebrahman1518 10 месяцев назад

    @Gaurav J - TheElectricalGuy
    thank you for your detailed explanation but Some people called this wasted energy (reactive power), but based on your explanation, it seems to be useful energy. please clarify

  • @sohelpathan6646
    @sohelpathan6646 3 года назад

    Sir is our domestic digital meter read reactive power?

    • @GauravJ
      @GauravJ  3 года назад

      No. We need VAR meter to read that

  • @bernardocisneros4402
    @bernardocisneros4402 Год назад

    Thanks for the video. One question: Which power or powers does the electric company charge customers for? Do they charge us for true power or apparent power?

  • @shubhankarghosh
    @shubhankarghosh 4 года назад

    Sir, Which video editor you use to edit veedios? ☺️

  • @DuongNguyen-iv4sj
    @DuongNguyen-iv4sj 3 года назад +1

    So in the case the net reactive power is positive, what kind of energy this power then transform?

    • @kalumprasannaHW
      @kalumprasannaHW 2 года назад

      Yes I have the same question , I think it's used in the non linear device. The power which created by the back EMF are fed to the line as negative reactive power, waiting to use by other devices. And I have a little suspicion that negative reactive power is consumed by the line resistance also .

  • @rahuldhyani3103
    @rahuldhyani3103 4 года назад +3

    How capacitor generate reactive power and inductor absorb reactive power ???? Explain

    • @imeprezime1285
      @imeprezime1285 3 года назад +2

      No reactive power is generated or consumed by these components. That's wrong/misleading choice of words. Reactive power is just present in a network, and its' mathematical sign ( for example in equation S=P+jQ) indicates character of loading, wether is inductive (+Q) or capacitive(-Q)

    • @carultch
      @carultch 2 года назад +1

      The Watts (instantaneous product of current and voltage) associated with the reactive power of either of these circuit elements, adds up to zero over an entire cycle. The power isn't really going anywhere, it is being stored in the components and released later. Inductors store power 1/4 of a cycle after the voltage waveform and release it 3/4 of a cycle after the voltage waveform. Capacitors do the opposite, storing power power 3/4 of a cycle after the voltage waveform, and releasing power 1/4 of a cycle after the next cycle of the voltage waveform. In the steady state, it appears as if the capacitor does the negative of what the inductor does, which is why we assign a negative sign to the capacitor's reactive power.

  • @deepakedss1769
    @deepakedss1769 3 года назад

    Sir if there is no capacitive load and there is only inductive load so there will be no supplying of reactive power to source there will be only reactive power consuming then what will be the condition of alternator and grid sir?

    • @GauravJ
      @GauravJ  3 года назад

      Conventional generators are also capable of either consuming reactive power or supplying reactive power. So, I cannot imagine grid without Reactive power.

  • @Mr.brewberry
    @Mr.brewberry 4 года назад +2

    Is there any cause damage when reactie power goes to sysyem back?

    • @GauravJ
      @GauravJ  4 года назад

      No. As I explained, this power is utilized by few devices which are connected to the same distribution network. So, there is no damage.

    • @Mr.brewberry
      @Mr.brewberry 4 года назад +1

      Sir, my question is
      What we assume the maximum reactive power goes back to system? And as you said motor, transformer assumed reactive power , what if maximum reactive power goes back and is there any source to use reactive power?

    • @Thrill98
      @Thrill98 3 года назад

      @@GauravJ then why factories are charged for extra tax because of inductive loads if it does not make any harm to distribution network

    • @GauravJ
      @GauravJ  3 года назад

      Hi. Why utility charge more for maintaining poor power factor, this i have explained in my power factor series. You can check out that playlist for the answer.

  • @vvenkatesh7385
    @vvenkatesh7385 3 года назад +1

    Sir please explain why...
    If 2 different phases meet then it short circuit. But how can a 3 different phases tied to neutral point in star connection can't get short circuited?

    • @bobbrumley3964
      @bobbrumley3964 3 года назад +1

      The three phases have already gone through their loads so voltage drop has occurred and are at 0v. If three conductors are at 0v then we can put together and create a neutral.

  • @sumitkunwer6500
    @sumitkunwer6500 6 месяцев назад

    Sir i think the wattmeter give the reading p=Vr×Ir×cos(phy)

  • @vibestouchessoul2602
    @vibestouchessoul2602 4 года назад +1

    भाई आपके हमारे ज्यादा से ज्यादा सब्सक्राइबर हिंदी लोग है आप आपने वीडियो में हिंदी का भी प्रयोग करे तो कुछ उन्हें भी समाज आये उससे आपका वीडियो शेयर करने में झिझक नही होगी और आपके सब्सक्राइबर भी बढ़ जाएंगे 😇👌🏻👌🏻👌🏻👌🏻👌🏻👌🏻👌🏻बाकी आपके वीडियो बहुत अछे है और समझने में आसान होते है keep it up bro…

  • @manoharping
    @manoharping 4 года назад

    Could you please tell me Sir, what is In Phase & Out of Phase? I just don't get it.

    • @justadreamerforgood69
      @justadreamerforgood69 4 года назад +1

      If the zero crossing and peak values of voltage and current happen at the same instant of time they are in phase else out of phase

    • @carultch
      @carultch 2 года назад

      The general equation of a sign wave is:
      y = A*sin(B*t + C) + D
      A is the amplitude
      B is the radian frequency. You may also see it labeled with the Greek letter lowercase omega.
      C is the phase offset
      D is the vertical offset (or DC offset in the case of electrical voltage waveforms)
      The C-term is the phase offset. It might also be labeled with the Greek letter phi, since the etymological root to the word phase starts with phi in Greek.
      When the C-terms of two waveforms of interest are equal to each other, the waveforms are in-phase. When the C-terms are not equal, they are out of phase. C-terms that are 180 degrees apart (or pi-radians) are exactly opposite in phase.

  • @omkarsapte4119
    @omkarsapte4119 3 года назад

    Sir as inductor and capacitor both are consumes the reactive power. Means at some instant they store power and at some instant they release power. That is at sometime their power is positive and at sometime their power is negative. Then why are u take reactive power of inductor as positive and that of capacitor as negative?? Can we take positive reactive power for both element that is for capacitor as well as for inductor??

    • @bobbrumley3964
      @bobbrumley3964 3 года назад

      They’re 180 degrees apart therefore one is positive and the other is negative.

  • @Durga189
    @Durga189 4 года назад

    Will motor run in this case? Because we are supplying more reactive power than what it actually consuming! In such case power factor maintained by motor would be unity.

  • @a-learnerforever
    @a-learnerforever 2 года назад +1

    Guys, look here! The capacitor does not just send power to the system, and the inductor does not just take power from the system.
    Imagine that you have an empty capacitor and you plug it into the ac voltage source. In the first miliseconds, when the voltage is positive for a capacitor, the capacitor will take the energy from the system. But then when the voltage drops below the capacitor's voltage level (alternative source changes its direction), the capacitor will give the energy back to the system. And this will go on.
    The situation is true for the inductor too. It does not just take energy from the system. But when they are used together, they do the transaction with each other, not with the system. As a result, the transmission lines that transport energy from the system to the source and from the source to the system will be free of unnecessary power transmissions.

    • @ramprasadram5808
      @ramprasadram5808 2 года назад

      Ss that's true becoz both have +ve and -ve power cycles

  • @pranabkalita1937
    @pranabkalita1937 4 года назад

    sir, is net reactive power power always negative?

    • @GauravJ
      @GauravJ  4 года назад

      Yes. Check out my video on active reactive and apparent power.

  • @McCurtainCounty888
    @McCurtainCounty888 3 года назад

    Isn't reactive power the magnetic portion of the circuit? Doesn't it it just swing back and forth from source and load? At least for the inductive part of reactance?

    • @GauravJ
      @GauravJ  3 года назад

      Yes it swings back and forth without doing any useful work.

    • @McCurtainCounty888
      @McCurtainCounty888 3 года назад

      @@GauravJ thank you so much. I wasn't 100% sure.

  • @ruan2587
    @ruan2587 4 года назад +2

    It's a really good video, just some information lacking on reactive power. All these types of videos explains what reactive power is and how to calculate etc. But like your comment of the reactive power flows to the distribution system, how does it flow? what does it look like? And your comment of the active and reactive power flow in opposite directions, again how does it flow and what does it look like?
    Is there a reason why videos don't explain this? Just feel like if this information is made available it will really cover the whole extent of reactive and active power. Nevertheless, good video sir.

    • @GauravJ
      @GauravJ  4 года назад +2

      Well the question is like, ‘if current is there then how does it look like?’ You can only imagine current (you can also feel it 😁) but you cannot show it, right? In the same way, commenting on how does reactive power look like would be difficult (however, you can have waveform for that), because no one has seen it!

    • @ruan2587
      @ruan2587 4 года назад +1

      @@GauravJ Thank you for your response. Yes I fully understand that it can not be seen and can only imagine it. I think the best way to visually display waveforms is having a test setup by using these power measurement devices that show the voltage and current waveforms and by switching different loads to see the displacement power factor and see how the waveforms react and based on these waveforms determine the active and reactive power measurements. Also really interesting how harmonics of non-linear devices effect these waveforms and power factor.

    • @GauravJ
      @GauravJ  4 года назад +1

      Exactly!

    • @chinnakarlapraveen9966
      @chinnakarlapraveen9966 4 года назад

      @@GauravJ nice reply sir

  • @ConstantineJoseph
    @ConstantineJoseph 3 года назад

    Do DC motors have reactive power?

    • @GauravJ
      @GauravJ  3 года назад +1

      No. Reactive power comes into picture only in case of AC circuits.

    • @ConstantineJoseph
      @ConstantineJoseph 3 года назад

      Gaurav J - TheElectricalGuy thank you! Even if the open circuit voltage in the DC motor is an AC sine wave?

  • @patrickjacobsen7805
    @patrickjacobsen7805 2 года назад

    How can it flow back to the system when the current is only oscillating back and forth?

    • @molntuss7113
      @molntuss7113 Год назад

      Compare it to how sound propagates through air. The sound travels from the source to your ear, but the molecules of the air are just oscillating back and forth. Or compare it to dominoes falling. The individual dominoes are not moving very far (they just fall where they are) but the point where the dominoes are falling is travelling as far as there are dominoes.

  • @mrpadmakar
    @mrpadmakar 4 года назад

    Explana about resonance

    • @carultch
      @carultch 2 года назад

      Resonance in general is what happens when a wave causes an oscillating component to also oscillate, due to the wave having a frequency that matches the natural oscillation frequency of an oscillating component.
      In electrical circuits, resonance is a property between a capacitor and inductor, relating to an electrical oscillation between the two components. There is a special frequency at which the inductor and capacitor will exchange a waveform back and forth to each other, such that the capacitor discharge and the inductor's "inertia" will produce this frequency together. The capacitor discharges, and the inductor stores the energy in its magnetic field. The inductor discharges its magnetic field, and the capacitor charges in the opposite direction. This happens at a frequency equal to 1/(2*pi*sqrt(L*C)).
      When a waveform is applied at the resonant frequency, a parallel combination of an ideal inductor and ideal capacitor will have infinite impedance and act as an open circuit. A series combination of an ideal inductor and ideal capacitor will have zero impedance and act as a short circuit.

  • @mandaleekaratnakar1749
    @mandaleekaratnakar1749 3 года назад +1

    You said that reactive power goes to system but the reactive power coming to distribution these two powers will not merge say sir

  • @estebiajero1670
    @estebiajero1670 3 года назад

    wait does it always flows back into the system. why cannot we use it on our own system?

  • @qosmioamit
    @qosmioamit 3 года назад +2

    To complete the thought on why one should not connect a capacitor to a circuit, the capacitor will likely explode instantly

    • @shakirmavoor
      @shakirmavoor 3 года назад +1

      If the capacitor has proper voltage ratings it will not explode

    • @qosmioamit
      @qosmioamit 3 года назад

      @@shakirmavoor yes, good point!

  • @lupulwedanny7757
    @lupulwedanny7757 Месяц назад

    i like your shirt its nice