FoxAlien Vasto XXL - Height Probe Configuration in UGS (Universal Gcode Sender).
HTML-код
- Опубликовано: 17 сен 2024
- Configuring the FoxAlien Vasto Cnc height probe in UGS (Universal Gcode Sender)
FoxAlien Vasto XXL bit.ly/3e3Eiee
UGS winder.github....
Vasto XXL table design:
www.techydiy.or...
#cnc
G21; G91; G38.2 Z-50 F100; G92 Z15; G0 Z5
witch board you use and witch pin it is connected
Is there video for auto leveler?
I'm doing this and when I send it to Z0 it goes down but stops about 4mm above the material, xe-pro machine with the same probe. Why? thanks!
No idea but try jogging the z axis by ( for example) 10mm or 1” and then measure how far it has actually moved. If it has moved the correct distance then measure the thickness of the touch plate and change the gcode to this value. Example: G92 Z14.95. For a height probe of 14.95mm. You can also type in each command individually and then check what happens. If the jogged distance is different then you need to recalibrate the z axis and change the grbl steps/mm setting.
@@techydiyreviews Fixed! As you said, the problem was in the config file (z steps/mm) Thanks!
@@markosmokovic9007 Cool