How to run three phase motor with single phase Supply

Поделиться
HTML-код
  • Опубликовано: 28 дек 2020
  • Please Subscribe to Easy PLC Tutorials for more Videos and Tutorials
    / @easyplctraining
    three phase motor with single phase supply
    How to run 3 phase motor with single phase power supply 220 VAC
    D.I.Y how to Wire a 3 phase motor to single phase 240v the easy way
    Connecting a 3 phase motor with 1 phase Power with Diagram
    -------------------------------------------------------------------------------------------------------------------------------------------------
    "Enjoying the content? Buy me a coffee and support the channel!
    buymeacoffee.com/nadeemalik1
    --------------------------------------------------------------------------------------------------------------------------------------------------
  • НаукаНаука

Комментарии • 187

  • @Eduardo_Espinoza
    @Eduardo_Espinoza 2 года назад +23

    A version off of RUclips that isn't a half hour long! Thank you :)

  • @andrewdean4304
    @andrewdean4304 3 года назад +9

    I’ve Done this a lot and works well on most motors, obviously you won’t get same torque but for certain
    Machines you can get away with it

  • @gyulavarga5349
    @gyulavarga5349 3 года назад

    Az ilyen átkötés nagyon nagy teljesítmény csökkenést okoz! Egyik szerkezet sem fog megfelelően üzemelni ami 3 fázisra lett tervezve. Ehhez kell egy megfelelő nagyságú frekvencia generátor ami 1fázis->3fázis üzemet tud! Ez így a 60-as évek buherációja!

  • @user-uk1pe7bj4f
    @user-uk1pe7bj4f 3 месяца назад +4

    note there is no EARTH wire used on this motor , if you wire up any motor make sure a fully earthed cable connected to the frame of the motor.

  • @mohamedishaq4425
    @mohamedishaq4425 8 дней назад

    السلام عليكم.
    مهندس عليوي انت فعلا مثال للمهندس الرائع.
    تسلم ايدك وربنا يبارك فيك و في زريتك و يحفظك

  • @peterjerold3184
    @peterjerold3184 3 года назад

    Good explanation

  • @Bianchi77
    @Bianchi77 2 года назад +1

    Cool video, keep it up,thanks :)

  • @jamalahmed4246
    @jamalahmed4246 2 года назад +2

    I want to learning about the best way of electrical systems for home use program 👍👍👍

  • @mstafaadan2506
    @mstafaadan2506 2 года назад

    Thanks that's amazing great video channel I like this post nice ideas

  • @tomtumun9791
    @tomtumun9791 3 года назад

    Thanks for sharing

  • @simpliciocamirino2271
    @simpliciocamirino2271 2 года назад

    thank you for that sharing sir.

  • @danielteyehuago1633
    @danielteyehuago1633 3 года назад

    Thanks for sharing it

  • @manikandanramalingam4489
    @manikandanramalingam4489 3 года назад

    Super bro thanks 👍

  • @mikegrant8490
    @mikegrant8490 3 года назад +12

    Commercially branded phase converters are available. Matching them up to the motor and wiring them up correctly is the key to getting the proper phase alignment. No loose capacitors hanging out, everything in a nice safe metal cabinet. NEC compliant.

    • @blackbirdxx928
      @blackbirdxx928 3 года назад +5

      Kinda easy to build. Never did anything like that before and I found d I instructions on the net...found a used 3 phase 7 hp motor for a hundred bucks, bought $50 worth of caps at a freght salvage, spent 4-5 hrs wiring and put it in a box...used it 2+ years on a 5hp lathe..it ran all day...got kind da lucky first try, 3 legs were within 4 volts...to buy the same deal cost a thou or more

    • @rupert5390
      @rupert5390 3 года назад +1

      Never mind those a welder with a 415 wining and a motor twice the size you want to run will give you a converter

    • @kingsleyazubuikeabonyi3612
      @kingsleyazubuikeabonyi3612 2 года назад +2

      @@blackbirdxx928 could you please share details like the capacitor values and your connections. I could use your experience now pls.

    • @subramaniamchandrasekar1397
      @subramaniamchandrasekar1397 2 года назад +5

      Some countries, the authorities switch off one of the 3 phases, so that 3 phase motor loads should not work during peak hours (6pm to 10pm). With a brief shutdown the phases from L1, L2, L3 becomes L1, L2, L2 at 6pm and after another brief shutdown at 10pm again becomes L1. L2, L3. Some used to connect a capacitor (10mfd per amp and 20% above supply voltage rating) as in the video and run it during the peak hours. Heavier loads are started with additional capacitor with a push button to start. Regards.

  • @kashifakram9636
    @kashifakram9636 3 месяца назад

    A great information thanks

  • @v.stechnicalwork950
    @v.stechnicalwork950 Год назад

    Excellent job keeptup

  • @expertcuttinglogicsystem5284
    @expertcuttinglogicsystem5284 3 года назад

    Very good

  • @mdnishan1536
    @mdnishan1536 2 года назад

    Thanks you sir

  • @Friskyrunner23
    @Friskyrunner23 3 года назад +1

    Syscap is best capacitor brand in India. World class quality.

  • @ugatronics
    @ugatronics Год назад

    Do you need motor starters like DOL, stardelta o you just connect it direct to single phase

  • @guliyevshahriyar
    @guliyevshahriyar 3 года назад

    Thx

  • @davidlixenberg5999
    @davidlixenberg5999 3 года назад +5

    I need the science behind any 'trick'.
    David Lixenberg

  • @nuwansurendra2848
    @nuwansurendra2848 3 года назад

    👍👍👍

  • @royaddison7853
    @royaddison7853 3 года назад +1

    That looks really good but why not just get a phase simulator and use it then your motor will operate properly

  • @mtrevlac
    @mtrevlac 3 года назад +5

    What is the formula to figure what capacitor to use and will it last as long a cycle as the motor running on 3 phase? I usually have to use a vfd in the situation.

  • @Mark-iy3sd
    @Mark-iy3sd 3 года назад +7

    Yes correct, it will turn the motor but, you will only be able to drive a very light load. There is very little torque. There are only two ways to solve the problem; 1, buy a single phase motor or 2, buy a variable frequency drive.

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад +3

      It's only idea ... capacitor will only shift phase 120 degree ... vfd is a perfect option

    • @bradpeterson278
      @bradpeterson278 2 года назад

      Good and perfect thanks

  • @channelview8854
    @channelview8854 2 года назад +5

    By far the best way to do this in modern times is to purchase a variable frequency drive with single phase input. This phase converter stuff was great for 100 years until VFDs became available.

    • @silentviewer.17yearsago65
      @silentviewer.17yearsago65 2 года назад +1

      not everyone need or can afford a VFD

    • @channelview8854
      @channelview8854 2 года назад

      @@silentviewer.17yearsago65 a plain one with few features doesn't cost much more than the capacitors and contactors needed for a phase converter. If there is a need for much starting torque, then an "idler motor" is needed. Costs could easily be more than the VFD. And if you need speed control or a specific acceleration profile, forget it.

    • @TheElderOne2003
      @TheElderOne2003 2 года назад

      @@silentviewer.17yearsago65 VFDs are stupid cheap these days. You may not need all the features but it will last longer than this cobble job.

    • @velvetypotato711
      @velvetypotato711 Год назад

      rotary phase converters are still great if you need to run large 30hp motors or multiple smaller motors at once. This is a good entry level project before building a rotary. Or a good way to test a motor at home.

    • @mohdrodzimohamad1104
      @mohdrodzimohamad1104 4 месяца назад

      Yes. I prefer to use single phase input to 3 phase output VFD. Motor performance much better.

  • @kasibagu6172
    @kasibagu6172 2 года назад

    Super

  • @azuzkharef2293
    @azuzkharef2293 3 года назад

    Good

  • @user-fz8ww4tr4h
    @user-fz8ww4tr4h 4 месяца назад

    How do you know the right specification for the capacitor thank you!

  • @skeetersaurus6249
    @skeetersaurus6249 2 года назад +5

    If VFD's are out of your 'price or availability range', depending on motor size; the best way is to simply build a rotary phase converter using a similar-sized single-phase motor...no (minimal) torque loss that way.

  • @prashanthyagati7727
    @prashanthyagati7727 3 года назад +3

    Sir, How can we calculate capacitor rating

  • @4frontinc
    @4frontinc 2 года назад

    How do you convert a 9-lead wire dual voltage 3 phase motor to single phase? I do not see any information or videos on this.

  • @BirukWolde-mn6hi
    @BirukWolde-mn6hi 11 месяцев назад +1

    voltage rating for capacitor should be 250 or 400v?

  • @ateeqabbasi9611
    @ateeqabbasi9611 2 года назад

    Can we use same star connection also?

  • @molotontelemaque7210
    @molotontelemaque7210 2 года назад

    It was counterclockwise first, then clockwise 2nd that's why the rotation was faster at last minute of video careful with tips man,good video though,thanks

  • @ModernDairy
    @ModernDairy 3 года назад +5

    What about the torque when we do this?

    • @MultiSoftE
      @MultiSoftE 3 года назад

      What torque?

    • @rupert5390
      @rupert5390 3 года назад +1

      There is none this guy is full of crap

  • @Aslam388
    @Aslam388 Месяц назад

    Nice

  • @SafeAndEffectiveTheySaid
    @SafeAndEffectiveTheySaid 3 года назад +10

    I believe the capacitive reactance must be as close as possible to the values of motor winding ohms resistance

    • @johnsonobari1755
      @johnsonobari1755 2 года назад +4

      Then we can obtain C, Rw=1/(2πfc), where Rw= motor winding resistance, and C is capacitance, f= source frequency, π=pi.

  • @TheBalconyWorkspace
    @TheBalconyWorkspace 2 месяца назад

    How does this work?
    Well in delta connection, the paticular winding paralleled with power has rated voltage on it. but one winding can't provide rotating megnetic field to start the motor, so with a capacitor in series with the other two windings the current in these windings has a phase difference, which produces a phase-shifted magnetic flux. When this magnetic flux gets mixed with the oroginal magnetic flux generated by the power-line-paralleled winding, a rotating magnetic field appears in the rotor, which gives starting torque. For this part you can refer to why single phase motors need a capacitor. Due to winding current limitation, the motor can only provide about 1/3 of the original rated power.
    I'm not a pro but this explains things fine to me.
    Accroding to experiences 20-30uF for every kW is useable, the guideline is to ensure that no winding is overloading by monitoring phase current.
    Remember to only use non-polarized capacitor such as oil-paper capacitor or metal-film capacitor, do not use electrolytic capacitors or any polarized capacitors for the risk of cap explosion and fire., and the capacitor used should have a voltage rating no less than the power voltage.

  • @katangaanthony7423
    @katangaanthony7423 2 года назад

    What causes a hammer mill produce sound?

  • @adarshmishra9300
    @adarshmishra9300 2 года назад

    Submersible bhi Chala saktey h Kya ?

  • @jboy4real
    @jboy4real 3 года назад +15

    How did you calculate the capacitor value you connected

    • @osutakizito2688
      @osutakizito2688 2 года назад +3

      A kw of motor per 70micro farad's, I don't know how

    • @chetanaher1487
      @chetanaher1487 2 года назад +1

      @@osutakizito2688 if supply is 220 V then we use 70uf capacitor per KV,

  • @kumaran7052
    @kumaran7052 4 месяца назад

    Hi...I have a 380v sewing machine clutch motor... I need to convert it to 220v...can you assist. thank you.

  • @alexeitarulis5942
    @alexeitarulis5942 2 года назад

    What would happen if it’s done without the capacitor? Will it burn?

  • @MechanicForGMCCars
    @MechanicForGMCCars 2 года назад

    Can some one explain me why peopel back in the days wound coils on brushes and commitators ???
    I see some patents online they have strange coils wound close to brushes for what are they used for exactly are those inductors for speed control???

  • @marinduquenogamer9902
    @marinduquenogamer9902 Год назад

    Can i ask you a question how you calculate the amount of capacitor to be use if the hp is higher or lower hp

    • @9534alex
      @9534alex Год назад

      70ųf per 1 kw of motor power

  • @mihajlokatancic9736
    @mihajlokatancic9736 9 месяцев назад

    Can't see capacitor specifications? Can you write them in comment, please?

  • @ashwinkumarsonkar8810
    @ashwinkumarsonkar8810 3 года назад +2

    Can i use this method for for long time/ permanently
    Does After long time the winding will burn ?

  • @aizammanaf1300
    @aizammanaf1300 3 года назад

    Hi i want to ask something. After u run the motor for 2-3 minutes, do u realize about the motor is become hot easily? I check the amp, i got quite high amp (5A) after run using this connection. And 1 more thing, i actually want to convert the panasonic inverter washing machine to using universal board (no need to replace original 3 phase motor if using this trick). But i have a problem that, while in wash mode, the motor only run in one direction only (usually running in two direction on off, in wash mode). Can u help me if u have any idea. Tq.

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад

      You can use a single phase input , three phase output, can connect reverse and forward signals from the universal board to inverter

  • @bebo5558
    @bebo5558 3 года назад +1

    Clockwise direction.

  • @chucksison9199
    @chucksison9199 Год назад

    this is how aircon compressor works

  • @mdamirul85
    @mdamirul85 2 года назад

    How many hours can be run with capacitor

  • @Afroz591
    @Afroz591 3 года назад

    How can I found cap value

  • @ohmkarvlogs
    @ohmkarvlogs 3 года назад

    Good information Sir, Can we run the motor maximum speed with this method!!

  • @SaffronHanu
    @SaffronHanu 8 месяцев назад

    Hi bro 3phase 3hp motor h.... Capacitor ka nam batao konsa use kru and run hogina motor??

  • @thediyfamilybrubakers4054
    @thediyfamilybrubakers4054 7 месяцев назад

    Is this 220v euro . 1 leg 220v?
    Not 220v 2 wire . USA?

  • @habibhabibov4610
    @habibhabibov4610 2 года назад +3

    how to calculate the capacitor for each power "KW " motor

  • @kurtharaldheitmann4112
    @kurtharaldheitmann4112 3 года назад +2

    Yes,it turns,but totally out of specification

  • @jannlestersinio9607
    @jannlestersinio9607 3 года назад +1

    Can i use 20mfd capacitor? Same motor rating

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад

      Can use , but check if motor start to heat up ?

  • @muraterdogan6516
    @muraterdogan6516 2 года назад

    Motor kW ?

  • @RayThackeray
    @RayThackeray 3 года назад

    Maybe one of you clever people can help. I have a Northern Lights 25kW generator and I planned to run a 3-phase 240v 20kW induction motor from it. The documentation I had said my generator was 3-phase but I just found out it's actually a single-phase output!! Damn. Any ideas how I can connect that to the motor and still run it at about 20kW of power?

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад

      25 kW generator with single phase output , serious problem for you dear.
      If your actual output load is about 5kw , you can use single phase input frequency inverter to give you 3 phase output.

    • @RayThackeray
      @RayThackeray 3 года назад +1

      @@EASYPLCTRAINING The actual power output needed is about 20kW. The generator is rated for 25kW.

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад

      My friend you need three phase generator output.

  • @vicentecarrasco3653
    @vicentecarrasco3653 3 года назад

    hi,a 3 phase 3kw motors for run in single phase is the same connection than the small 3 phase motors?

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад +1

      Up to 1 kw only dear

    • @vicentecarrasco3653
      @vicentecarrasco3653 3 года назад +1

      @@EASYPLCTRAINING OK,but the problem of the biggest motors i hear they need use two different capacitors so that they run well.

    • @vicentecarrasco3653
      @vicentecarrasco3653 3 года назад +1

      up to 1.5kw need use two differents capacitors.

    • @vicentecarrasco3653
      @vicentecarrasco3653 3 года назад

      for example 2.2kw,3kw,4kw,4.5kw 5.5kw motors.

  • @qazibilalrasheed2544
    @qazibilalrasheed2544 3 года назад +2

    Is it going to work for 3HP submersible pump?

  • @krishnapatelpatel7459
    @krishnapatelpatel7459 3 года назад +1

    Three pesh 20 hp pump, single pesh me kese chalaye
    Eske upar video banao

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад

      20 hp not possible

    • @krishnapatelpatel7459
      @krishnapatelpatel7459 3 года назад

      @@EASYPLCTRAINING kiyo Bhai
      Single pesh se 20 hp motor pump nahi chalta Kiya ?

    • @Mr_Cap.
      @Mr_Cap. 3 года назад +1

      @@krishnapatelpatel7459 nahi, itni starting torque produce nahi kar payega.

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад +1

      Rightly said

  • @digitaria
    @digitaria 2 года назад

    Get a schneider inverter/speed control

  • @jaysonlopez6128
    @jaysonlopez6128 2 года назад

    Sir what capacitor fits 3 hp motor? Sir 1 more question, if my motor is 3 HP , will it retain its power if I use capacitor to run it in a single phase power?

  • @TFDCOGI
    @TFDCOGI 2 года назад

    Can you do this on a 3 phase soft serve ice cream machine so it will run on single phased

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  2 года назад

      What is the voltage rating of your motor in delta and star ?

  • @janjanboquia6738
    @janjanboquia6738 2 года назад

    Is the horsepower still the same when we use single phase isntead of the 3phase.?

    • @solotronixTV
      @solotronixTV 2 года назад +2

      No , you lose alot of torque and speed

  • @boybravo689
    @boybravo689 2 года назад

    sir may i know what is the voltage rating of the capacitor

    • @MrRockinneil
      @MrRockinneil Год назад

      Just make sure the rating of the capacitor is higher than the motor rating.

  • @saadunj8317
    @saadunj8317 3 года назад

    Does this machine work with single like three phase?
    It's power i mean...

    • @wangaui
      @wangaui 3 года назад

      No it won't have as much power or torque use a 240v single phase to 240v 3 phase inverter

  • @dsrinivas8914
    @dsrinivas8914 2 года назад

    How much time we run 3hp motor

  • @joemedz3381
    @joemedz3381 3 года назад

    What is the maximum size of 3phase motor that can be run by single phase

  • @bambangtanaman2287
    @bambangtanaman2287 Год назад

    mana spek motornya ,kan berhubungan kw dan mfd kapasitornya,kalau g pas amper akan naik dan motor panas

  • @SudhanshuKumar-it6nj
    @SudhanshuKumar-it6nj 3 года назад +1

    If converting 3phase machine in single phase then motor power increase or decrease karna chahiye.

  • @asakayosapro
    @asakayosapro 3 года назад

    Just go and buy a Variable Frequency Drive of double the amps /ampacity rating of the motor. This capacitor thing is only a quick check and test for a motor with no load attached, and usually the motor will not have the rated horsepower, unlike with a VFD that has true three phase driven by power fets from it's DC bus. Needless to say, with a VFD the consumption and amperage required will be higher.

  • @cooldude44ful
    @cooldude44ful 3 года назад +1

    10 MFD will work in any KW?

  • @JB-Brack99
    @JB-Brack99 5 месяцев назад

    Very informative. I liked ..the best so far explanation.
    I have to hook up a 3 phase air compressor to a 2 phase service.

  • @andychhora3896
    @andychhora3896 2 года назад

    Kitne hp ki moter h ye

  • @sanjaykushwasha4749
    @sanjaykushwasha4749 2 года назад

    Kya 10 hp motr aata cki yali kamyab he

  • @prashanthyagati7727
    @prashanthyagati7727 3 года назад

    Sir, is capacitor voltage rating 230v or 440v?..

    • @richardkaz2336
      @richardkaz2336 3 года назад

      On a 220/240vac single phase system you would us a 440v capacitor note you would only use this for small 3 phase motors

    • @datthuyogu283
      @datthuyogu283 Год назад

      3hp ok na

  • @roylanreyes3241
    @roylanreyes3241 Год назад

    Sir I have 3kw motor wye connection , 3 phase how much capacitor do I install to run the motor.

  • @rashilgagi7738
    @rashilgagi7738 10 месяцев назад

    Sir amar 3 phase 20 hp motor k.. Single phase kore rise mill r jonno chala tey parbo plz sir janaben...

  • @satendrachaturvedi5739
    @satendrachaturvedi5739 Год назад

    sir How much HP of this motor?

  • @hailiesetargie7449
    @hailiesetargie7449 Год назад

    How to convert three phase to single phase?

  • @sonnypillarina6056
    @sonnypillarina6056 8 месяцев назад

    Please help me ..what capacitor i need in this 3 phase motor..to 220v single phase.
    Motot specs..
    Y delta 346-480/200-280volts. 1.40/2.45 A
    Cos♤ 0.84. 0.55 kw. 3400 1/min. 60Hz
    Please what exsact running capacitor i need. Thanks

    • @TheBalconyWorkspace
      @TheBalconyWorkspace 2 месяца назад

      I dont know how to calculate but from experiences a 450VAC nonpolarized capacitor with 20microfarad capacitance should do the job, btw this makeshift can only provide 1/3 of the rated power.

  • @ImranKhanbhatti408
    @ImranKhanbhatti408 3 года назад

    Please sirr help me my problem three face brack to single face

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад

      Three phase input transformer to single phase output

  • @symak2887
    @symak2887 3 года назад +2

    Hi 4kw compressor 3 phrase to single phrase need to use which capacitor size?

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад

      4kw not possible to run , only upto 1 HP

    • @symak2887
      @symak2887 3 года назад +1

      @@EASYPLCTRAINING why is it not possible? Can't I just use higher capacitor? maybe 280 uF?

    • @RaviKumar-uy8ss
      @RaviKumar-uy8ss 2 года назад

      i heard that its danger to running the 3 phase motor with capasitor?

  • @bryansoleta2101
    @bryansoleta2101 2 года назад

    what is the capacitnce value you put on

  • @wazileiyjh
    @wazileiyjh 7 месяцев назад

    He use 10 microfarad ac capacitor

  • @haidernet6112
    @haidernet6112 7 месяцев назад

    2hp motor runing capictor use

  • @alexmorrison3068
    @alexmorrison3068 4 месяца назад +1

    How much uf?

    • @leo959
      @leo959 2 месяца назад

      10

  • @nalin.p3779
    @nalin.p3779 3 года назад

    But y rpm is low?

  • @MrAliusman73
    @MrAliusman73 3 года назад

    Can we run 11kw 3phase motor using this method?

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад

      No .... this is only for small motors

    • @hamzayahya1217
      @hamzayahya1217 3 года назад

      @@EASYPLCTRAINING can we run 3kw 3phase motor using this method

  • @michaelembrado7371
    @michaelembrado7371 3 года назад

    How about the reverse?

  • @rajeshakula8376
    @rajeshakula8376 3 года назад

    It will run on empty, will not take load!

  • @creativeinvention5553
    @creativeinvention5553 3 года назад

    Single phase motor using capacitor couple of seconds just for motor starting up only . So ... 3 phase motor depending capacitor constantly supply power for running not for working ! Isn't it ? How about tork ? Is this reliable and capacitor will generate heat and exploded in couples of minutes ...

  • @sudhangshupal4249
    @sudhangshupal4249 3 года назад

    What is the drawback of this method??

    • @janwelde9569
      @janwelde9569 3 года назад

      The main drawback of the "Steinmetz connection" is less starting torque.
      Secondly, for larger motors the capacitor will be quite expensive.

  • @selfmade128
    @selfmade128 4 месяца назад

    How do I size the capacitor? Or why that particular rating capacitor?

  • @wasimedoo7994
    @wasimedoo7994 2 года назад

    How do you know

    • @wasimedoo7994
      @wasimedoo7994 2 года назад

      What size of capicator to used for what size of motor