AM2S and/or AM2 Training, Preparation, Revision - Sample - 3 Phase Motor And D.O.L. Starter

Поделиться
HTML-код
  • Опубликовано: 18 окт 2024

Комментарии • 55

  • @georgeweston9024
    @georgeweston9024 2 года назад +13

    I just recently passed my am2s assessment and want to say thanks. Your videos were very helpful in my preparation.

    • @XSTrainingLtd
      @XSTrainingLtd  2 года назад

      That's very kind of you to take the time to share your comments on our AM2 Preparation Course videos George. We're delighted they helped you pass your Practical examination. All the best :-)

    • @ryansidhu4074
      @ryansidhu4074 2 года назад

      Got mine in a month what kind of revision helped you the most mate?

  • @seanperry8122
    @seanperry8122 2 года назад +7

    Just wanted to say a big thank you for your videos, I found these invaluable for preparation for my AM2 which I was extremely nervous about. I'm happy to say I passed first time. Thanks again guys!

    • @XSTrainingLtd
      @XSTrainingLtd  2 года назад +1

      You're very welcome Sean and thank you for taking the time to stop by and let us know. Our AM2 Preparation course was our very first in house course and it's currently still our most popular with, we're delighted to say, a very high learner pass rate :-)
      Anyone who's interested can find out more at our XS Training Academy site - www.xstrainingacademy.com
      Thanks again Sean - very appreciated. All the best

    • @whitebeltlyfbjj3393
      @whitebeltlyfbjj3393 2 года назад

      Any tips on how to better prepare

    • @XSTrainingLtd
      @XSTrainingLtd  2 года назад

      Hi, Thank for the comment.
      The AM2 preparation course is brilliant to better prepare yourself for the AM2 and is available from the XS Training Academy www.xstrainingacademy.com

  • @almartin727
    @almartin727 2 года назад

    The clearest explanation I have seen for this. Many thanks 👍

    • @XSTrainingLtd
      @XSTrainingLtd  2 года назад

      Thank you, we try our best to include everything to ensure your AM2 experience is less stressful.

  • @oseaghaku
    @oseaghaku 4 года назад +6

    Can you please show the full installation I mean final installation....how it all look

    • @MrBradleya16
      @MrBradleya16 4 года назад

      they do have all the videos but they want 125 + vat for them, so you have to pay if you want to win

  • @nathancurtis2585
    @nathancurtis2585 2 года назад

    Are all the terminals between the isolator and the top of the contactor already done? And is the sy cable already pre made up of is that something you have to run yourself.

    • @XSTrainingLtd
      @XSTrainingLtd  Год назад

      Hi Nathan, thank you for your comment. The control cables are prewired within the DOL, yes. The only part you will need to do, is the supply to the Isolator using singles and then install and gland off the SY cable. Please watch the video in relation to the control cables though, as you will need to know these connections when you come to the fault finding.

  • @jobjoby1336
    @jobjoby1336 2 года назад

    Excellent teaching.

    • @XSTrainingLtd
      @XSTrainingLtd  2 года назад

      Thank you, we try our best to include everything to ensure your AM2 experience is less stressful.

  • @sn2319
    @sn2319 2 года назад

    Hi
    I just wanted to know about the socket for load side: is it a spur/fused spur? or it's just a socket for motor? and what is the termination look like? I can not see the full picture for termination may be its not close enough? I do not know. Even though I had all the videos but there was not any termination for the load end?
    thanks

    • @XSTrainingLtd
      @XSTrainingLtd  2 года назад

      Hello, thank you for your comment. Is it the Motor circuit or the Ring Final circuit that you are referring to?

  • @alanstewart1073
    @alanstewart1073 2 года назад

    The cable coming out of the remote switch is left out for your assessment.....am I right in saying it needs to be terminated into terminal 96

    • @XSTrainingLtd
      @XSTrainingLtd  2 года назад

      Thank you for your comment. This is correct Alan.

  • @alexgiles139
    @alexgiles139 2 года назад

    hold up a second... i swear this guy used to work as a tutor in leeds. pretty sure he tought me in my first year

    • @XSTrainingLtd
      @XSTrainingLtd  2 года назад

      You may very well be right - Jamie Gibbs started out working as an Assessor for XS Training but left the college a couple of years ago now to take a senior manager role with the company. A great guy, we're really lucky to have him :-)

  • @chrissamson6171
    @chrissamson6171 2 года назад

    Do you have to sleeve the L2and L3 with brown at all? Also the grey sleeve with blue?

    • @XSTrainingLtd
      @XSTrainingLtd  Год назад

      Hi Chris, thank you for your comment. L1, L2 and L3 need identifying as Brown, Black and Grey.
      Black and Grey sleeving will be used if your centre has it available. Some centres don’t and this is why the video shows an alternative way.

  • @kendoknackersackee
    @kendoknackersackee 4 года назад

    Is the plastic cable tie OK, or should they now be metal ties to comply with regs?

    • @jamiegibbs5348
      @jamiegibbs5348 3 года назад

      The majority of AM2 centres still use the PVC clips as there would be no risk of the cable dropping in the event of a fire. A longer cable installed horizontally would definitely need metal ties. If the centres have upgraded there specifications and have metal ties, yes use them.

  • @DaveWHU91
    @DaveWHU91 Год назад +1

    Does anyone know how you would do an insulation resistance test on this? I failed this on my AM2

    • @XSTrainingLtd
      @XSTrainingLtd  Год назад +1

      Hi Dave, you need to test IR from the board and then again from the load side to ensure you test the supply and load side. Test between L1 - L2, L1 - L3, L2 - L3, L1 - N, L2 - N, L3 - N, L1 - CPC, L2 - CPC, L3 - CPC and N - CPC from both ends.

    • @maxdunning5612
      @maxdunning5612 Год назад

      did you test both sides of the DOL ? use the plugs on the simulated motor box to test IR to the DOL, same when you do r1+r2. hope this helps

  • @smacznykonsek
    @smacznykonsek 4 года назад +1

    Is there any reason why all line cores of SY cable have been sleeved with brown, if I see correctly, rather than with brown, black and grey (for 3 phase)?

    • @jamiegibbs5348
      @jamiegibbs5348 4 года назад +1

      SY is manufactured with black insulated cores, which are numbered. Some centres ask for the cores to be sleeved brown first. Then number 2 identified with Black sleeving and number 3 with grey. If you look closely they are identified in this way. If the centre have Brown, Black and grey sleeving available, please use this. Thank you

    • @smacznykonsek
      @smacznykonsek 4 года назад

      Jamie,
      Thank you very much for the answer

    • @matthewdavis1875
      @matthewdavis1875 Год назад

      Would you fail the am2 if you failed to sleeve the sy cable all together ?

  • @Kieran-jq5kk
    @Kieran-jq5kk 2 года назад

    Hi, is this rig similar to the actual am2 rig that is used in the prep courses and exam?

    • @ItsmePav
      @ItsmePav 2 года назад +1

      Yes very very similar

  • @gurvinders219
    @gurvinders219 4 года назад

    Add more video for other circuit and Risk assessment for am2

    • @XSTrainingLtd
      @XSTrainingLtd  3 месяца назад

      Please visit www.xstraining.com and see the options for the 14 day and 12 month access to all the videos.

  • @Wawaw738
    @Wawaw738 7 месяцев назад

    Why are they asking for SY cable to be used to supply a motor ?

    • @XSTrainingLtd
      @XSTrainingLtd  7 месяцев назад

      Hi, this is on the specification of the AM2 practical assessment you will have to take.

  • @17italyman
    @17italyman 2 года назад

    does the load side not need a neutral ?

    • @XSTrainingLtd
      @XSTrainingLtd  2 года назад

      Hi,. Thank you for your comment. The AM2 specification states 3 phase , 3 wire is to be installed.

    • @fennybenton8705
      @fennybenton8705 Год назад

      So will the SY cable provided will be 3 core for the 3 phases and cpc is provided by the SY braiding.

    • @uplightuk8924
      @uplightuk8924 Год назад

      @@fennybenton8705 No, the braiding on SY cable cannot be used as a CPC

    • @fennybenton8705
      @fennybenton8705 Год назад

      @@uplightuk8924 Yes found that out but thank you for replying

    • @uplightuk8924
      @uplightuk8924 Год назад

      @@fennybenton8705 So how did you get a CPC to the motor?
      I’m curious because when I done my am2 we used 5 core SY but someone on our firm who just done the Am2 said it was 4 core SY, 3 for phases 1 for neutral so now you run a separate cpc?

  • @Notyel
    @Notyel 6 месяцев назад

    I got my results back and this is the only bit i have to retake 😢

    • @XSTrainingLtd
      @XSTrainingLtd  6 месяцев назад

      All the best for your retake 🤞

  • @deniscotter525
    @deniscotter525 3 года назад

    Your left elbow is practically touching the 3 phase incoming supply

    • @jamiegibbs5348
      @jamiegibbs5348 3 года назад

      The DB is safely isolated. The connection points are not accessible and as a risk assessment has been carried out at the start and therefore I have deemed to be working in a safe manor.

  • @uptimusprime9876
    @uptimusprime9876 4 года назад +1

    Do we have to terminate and 2nd fix the sy cable? Or would that be pre wired already?

    • @robertwilliams7222
      @robertwilliams7222 4 года назад

      Yes you have to run it and terminate it.

    • @jamiegibbs5348
      @jamiegibbs5348 4 года назад

      You do need to first fix and second fix the SY cable.

    • @springhy
      @springhy Год назад

      Will you have to wire the contractor or does it come pre wired? So will you wire the incoming and outgoing to motor only?

  • @salahmoradnezhad2971
    @salahmoradnezhad2971 4 года назад

    Hhh that is exactly test centre of Am2. Make sure NET doesn't know about this video because you will put yourself in trouble mate.