Hoshizaki km clogged drain

Поделиться
HTML-код
  • Опубликовано: 20 янв 2025

Комментарии • 5

  • @atljgaming7762
    @atljgaming7762 11 месяцев назад +2

    Life saver!

  • @FabShopFive
    @FabShopFive 2 месяца назад +1

    Thank you for the video! Im a new owner to a used km630mah after harvest my machine overflows water into the bin like 3gallons worth. Is it supposed to do this?
    Also the hose going from the pump to the part your showing in this video the guy I got it from had hemostats on the big hose pinching it off and I removed them . Maybe that gives insight. If you have any knowledge to share will be much appreciated. Thank you

    • @jimmyc7401
      @jimmyc7401  2 месяца назад +1

      Sounds like the drain is clogged. The part that is removed from the inside is the overflow tube and drains to the rear of the machine. It starts filling for the first minute then compressor comes on, three minutes later the unit starts freezing. if the correct water valve is in place and no one has messed with the dip switches on the board three gallons may be close to correct. Don't know why someone would restrict water flow unless someone placed wrong flow water pump or spring in bypass tube is weak. Hope this helps.

    • @FabShopFive
      @FabShopFive Месяц назад

      @ thank you. It was clogged and now it’s working properly. Now my binstat is acting up but I jumped the wires for time being and have one on the way. Thanks for the video and advice

    • @jimmyc7401
      @jimmyc7401  Месяц назад +1

      @@FabShopFive Glad to be of help.