Good job. I just subscribed. I'm here in the US and I do appliance repairs. I do refrigeration also. I rarely have to flush but good to know. I work on a lot of LG refrigerators and sometimes they get clogged up with oil. I really have no problems with them and just push the high side back with nitrogen after disconnecting the discharge at the compressor. I do get oil logged evaporators from time to time. I got one right now that has a restricted capillary going to the freezer. Looks like I need to flush or replace the capillary. The evaporator was oiled up pretty bad. Most of the issues on LGs is bad compressor after they overheat from dirty condenser. Good learning from you. Salamat brother.
Bago Lang ako sa channel mo bossing, ac technician din ako, pero marami parin akong natututunan sa mga video mo, Salamat kabayan. More power sa ating mga technician. Watching from Riyadh KSA.
Dapat nitrogen Ang gamitin kung mag flushing with r141b. Para Hindi mag frost Ang moisture sa loob ng system. Kasi kung freon Ang e flushing at may moisture sa loob ng system ay titigas. Kya mag babara.
Salamat sa info. bro., May tanong lang ako sa relay at overload protector ng compressor ko,ang nakita ko sa comp. ay bilog na may dalawabg terminal at isang white na may tatlong butas. alin sa dalawa ang relay at overload protector. ung white na may tatlong butas na nkaattach sa tatlong terminal ng comp. ay parang maliit para maging relay. paki explain bro. salamat
Gud day Kuya j..very clear and informative Ang paliwanag nyo..ask q lng po sa mga inverter ref na r600a, pwede po ba gamitin 134a pang pressure?salamat po and Godbless
Kuya j tech mukhang magandang klasi ang tourch natin..saan ka po naka kuha nyan?i mean may pag kakaiba iba ang kanyang quality..sana ma.pansin mo ang tanung ko.
Hi Sir, tanung ko Lang po Yung refrigerator po namin denefrost ko po sya Kung Gabi Kasi Ang kapal na Ng ice sa gilid. Pagkatapos ko pong malinis sinaksak kna po sya ulit ok Naman gumana po sya, pero pagka fusing ko Ng Umaga Hindi na po sya umaandar at Hindi na nag yelo Yung freezer.
Good day Sir. I just want to ask something. I have an upright freezer that I wanted to make the freezing faster. Can I use the TXV, to modify the speed of running refregerant. Thanks in advance for any info.
@@KuyaJTechnology salamat master, walang bang problema pag gamitan ko ng 141b pag flushing sa evaporator sabi kc ng iba bawal daw pag inverter ang ref.
ako pag nag flushing r22 wala ng gauge deretso n khit wla ng r141b.. pra makatipid kaunting liquid and then sundan ko ng nitro kya tipid s freon.. kung my oil kita m tlaga malapot n oil n mix liquid..
Wow salamat, umabot sa England hehe. Barado yung daanan ng hangin pababa sa chiller compartment. Pwedeng yung damper sir ay di nagbukas dahil nagloko yung sensor. May cover kasi yan (damper) na nag open close kung tama na yung lamig. Now kung nagloko yung sensor na nag command ng open close nung damper yun ang dahilan na walang lamig ang chiller compartment.
Sir additional info..ref timer pwede rin or evaporator heater at sensors problema kaya nagyelo evaporator at di makadaan hangin papunta sa ref compartment.2 klase ang timer electronic at mechanical..pag di nagstop ang compressor at di nagtransfer sa heater yung power mag yeyelo yung evaporator coil at magbabara ng yelo yung daanan ng hangin papunta sa babang compartment kaya di lalamig ang babang compartment
Very informative tutorials KUYA J tech SALAMAT KUYA,SANA wag ka ka MAGSAWA SA pagshare about repair ref & a c. Thanks a lot sir J.
ll
llp00lllpp
Salamat po master..nkapa laking tulong po ito s tulad kng baguhan s ref&aircon..
Good job. I just subscribed. I'm here in the US and I do appliance repairs. I do refrigeration also. I rarely have to flush but good to know. I work on a lot of LG refrigerators and sometimes they get clogged up with oil. I really have no problems with them and just push the high side back with nitrogen after disconnecting the discharge at the compressor. I do get oil logged evaporators from time to time. I got one right now that has a restricted capillary going to the freezer. Looks like I need to flush or replace the capillary. The evaporator was oiled up pretty bad. Most of the issues on LGs is bad compressor after they overheat from dirty condenser. Good learning from you. Salamat brother.
Thanks bro..nadagdagan yon kakarampot kong kaalaman...THANKS..new subscriber
Sir thanks for sharing this video.malaking tulong Ito sa Amin sa paggawa ng mga ref.gidbless po.
Salamat bro sa diskarte na tinuro gusto ko matutonan ganyang trabho
J tech inverter Ang ko kuya. Tnx and more power to you
Nice boss tnx informative talaga solid
Salamt sa pagbahagi bro...Mabuhay ka..
Salamat boss sa pag share ng kaalaman Salamat GodBless
Kuya j tech salamat dagdag kalaman God bless po
Very informative...and knowledge ble video..👍
Saluti di TodoFrigorista 👍
Master nice tutorial watching matagal na kong di naka repair ng ref mula ng nawala yun pang vacuum ko
Snappy Kuya tech! A very impormative tutorial for the newbies. Kudos to you! Very detailed explanation! Salamat!👌🤜🤛
Salamat boss my natutunan ako
Salamat boss naka antabay lagi sa mga upload mo boss
Idol galing talaga
wala na ako masabi kuya. contgrats
Thank you idol...
Bago Lang ako sa channel mo bossing, ac technician din ako, pero marami parin akong natututunan sa mga video mo, Salamat kabayan. More power sa ating mga technician. Watching from Riyadh KSA.
Thank you sir
Naghome service ka ba boss
good job Kuyya, but you forgot change oil in compressor.. like
Just check my previous video
God bless kuya j..
Salamat sa idea master
God job boss j. Ingat..
Ganda ng embudo mo idol para sa 141b
Nice job
salamat po mr kuya..
Dapat nitrogen Ang gamitin kung mag flushing with r141b. Para Hindi mag frost Ang moisture sa loob ng system. Kasi kung freon Ang e flushing at may moisture sa loob ng system ay titigas. Kya mag babara.
bagohan kalng sguro kaya nga meron vacuum pump
Nice sir good job..
good job ❤️❤️
love from india 🇮🇳
Good job sir thanks for sharing new supporters here
another nice one kua jtech..godbless po
Boss good evz saan po ba ntin mabili yang 141b? At ang clasing prisure tank yong gimit mo.....salamat po sa tutorial dahil nkapag review po ako
Good job
hi boss may tanong aq ung bng R32 freon ng split type ppalitan q ng R410 pede ba un sir tnxsss sa mga vlog mo dami me natutunan
Thank you sir
God bless po.
Sir DIY Lang Ako wed bang isalpak ang compressor galing ref tapos ilagay KO Sa be chest freezer ko
Thanks sa n u kuya laking 2long to😀
Ang Cra nian Starting relay.. Bumigay na
Boz ...Anong freon ang pinangtulak mo sa 141b?? Tnx
Boss pwde po ba gwin sa cake chiller?? Ang pag flushing? Antay ko po sir sgot nyo
Salamat sir.
Galing mo sir idol Sana turoan mo ako sa actual😊😊😊
Master ano PO magandang gamitin may silica or Wala salamat master
Salamat sa info. bro., May tanong lang ako sa relay at overload protector ng compressor ko,ang nakita ko sa comp. ay bilog na may dalawabg terminal at isang white na may tatlong butas. alin sa dalawa ang relay at overload protector. ung white na may tatlong butas na nkaattach sa tatlong terminal ng comp. ay parang maliit para maging relay. paki explain bro. salamat
gud am sir,salamat sa demo mo,napanood ko thank you ,sir ask lang anong freon pinang flushing mo sir
Di freon yan. 141B yan
Very informative..thanks 👍👍👍👍👍.Dami ko natutunan
Gud day Kuya j..very clear and informative Ang paliwanag nyo..ask q lng po sa mga inverter ref na r600a, pwede po ba gamitin 134a pang pressure?salamat po and Godbless
Pwede, basta vaccum mu lang ng mabuti
@@KuyaJTechnology Qaqa ni
sir mga ilang cfm ng vacuum pump ang kailangan para sa upright freezer? pwede n po ba ang 3cfm?
Gud day po sir meron ka po ba video pano po magflushing sa r22 po split type po salamat po
Ser matanong lang hinde ba pomotok ang compresur pag barado ang pipe
sir maliban sa swet relay may ibapabang klasi....oh isa lang ang design lahat...
Sir wala na pong r 141b ano po ang pamalit na pang flushing? Salamat sa response.
Wooow happy new year kuya.
Sir gumagawa kayo ng ref na nabutas pwede pong pagawa sa ref namin dito sa Clark Pampanga
Gud day po kuya j..ano po freon gmit nio sa panv pressure ng 141B
Good day sir tuwing kailan Po nag dadagdag Ng oil o kailangan pba magdagdag Ng oil pag nag flushing
Pede ba sa compresor flo..ilagay sa loob ng compresor
Very good information what is the chemical you used and can you translate into English language please thank you
Kuya j tech mukhang magandang klasi ang tourch natin..saan ka po naka kuha nyan?i mean may pag kakaiba iba ang kanyang quality..sana ma.pansin mo ang tanung ko.
Mumurahin lang yan sir nabili ko sa shoppee.
Thank you bro.
Sir tama lang po ba ang singil na halagang 3500 na ang sira nya ay filter dryer?sana po makakuhaako ng advice mola sainyo?
bkit pinapahigop ng glue ang capillari tube?tnx!.
Sir j good day ask ko lang po lverter na reef namin ayaw tumigas ng yelo at ice sa freezer toshiba ang brand
So benta na lang yung yun luma strainer sa junkshop kuys hahaha 😆😆😆
Pag inverter na r600 master ay ganyan din po ba ang peoseso ng pag retropit?
Idol ok lng ba na r22 ang gamiting pang flushing sa mga ref? Tnx idol
Hi Sir, tanung ko Lang po Yung refrigerator po namin denefrost ko po sya Kung Gabi Kasi Ang kapal na Ng ice sa gilid. Pagkatapos ko pong malinis sinaksak kna po sya ulit ok Naman gumana po sya, pero pagka fusing ko Ng Umaga Hindi na po sya umaandar at Hindi na nag yelo Yung freezer.
kua jtech..ask lang po..magka iba un flushing system sa evacution? or d same lang.
Magkaiba po yan sir.
salamat po san po ang Repair Shop nyo sir?
good job sir
Thank you sir
kua jtech ask lang po may vlog din poba sa A/C na mag flushing po slamt po sa sagut godbless po...
Baka sa susnonod sir.
Sir pag flushing mo sa evaporator ilang psi ang pressure?
Good day, ask ko lang. tuwing kailang ginagawa yung flushing? Thank you.
Pwede naman yan lucker thinner gamitin
Good day Sir. I just want to ask something. I have an upright freezer that I wanted to make the freezing faster. Can I use the TXV, to modify the speed of running refregerant. Thanks in advance for any info.
kuya j bat kya pag nagpflushing aq hndi lumalabas ang 141b khit mdami n aqng nilagay?puro hangin lng ang lumalabas.
Very informative tutorial.Kuya ask ko lng ilan po dapat na pressure using manifold gauge pag magleaktest or magfflushing
ng ref.?thanks po in advance
Kung sa refrigerator leak test 50 to 70 PSI, flushing 100 PSI
@@KuyaJTechnologythanks,kapag DIY na compressor gamit ko sa pag flushing kahit di nb gumamit ng manifold gauge derikta na lng sa DIY ko compressor?
Pano po kung nawawalan na ng lamig ang ref sa baba po walang lamig salamat god bless po
Sir Jay 134a ba ang ginamit mong pang FLUSHING sa system?
Thanks and more power to your you tube channel.
Master maliwanag ang mga tutorial, ano refrigerant na gamit pang flushing puede sa r600 ang ref, puede kaya ang r22
R22
@@KuyaJTechnology salamat master, walang bang problema pag gamitan ko ng 141b pag flushing sa evaporator sabi kc ng iba bawal daw pag inverter ang ref.
Sir kun walang 141b ba pwd po ba gamitin ang pang flush ei gas
Kuya ung compressor puedi ba yan gamitin sa pag install ng air condition?
Sir ano po ba mas maganda bilhin sa ngayon? inverter o non-inverter?
Balak ko kasi kunin panasonic inverter direct colling
Magkano po pa sirvice ng pag lagay ng preon
Sir ask ko lang po nag seservice po ba kayo Montalban rizal
Natusok ng knife ung freezer habang nagtatanggal ng yelo?
Nasa negros po ako sir
@@KuyaJTechnology ang layo mo pala sir,kaya po bang marepair ung unit na ganoon.ung nabutas na ang freezer tumagas na ang freon?TIA Kuya JT
Thanks👍
Which gas you are using for pressure 134 or any other
Anong brand po gamit nyo na torch
Yung mabibili sa shoppee lang yan sir
Nag seservice po b kyo
ok lng po b msbaliktad ang pagkabit ng filter dryer s capillery tube?
Follow nyo po may arrow naman yan
Boss ask po ano pinaka liit na size ng compressor 1/8 po ba. Salamat
Parang may 1/10 pa yata.
Gud day kuya j magkano po singil sa ganyan?
ako pag nag flushing r22 wala ng gauge deretso n khit wla ng r141b.. pra makatipid kaunting liquid and then sundan ko ng nitro kya tipid s freon.. kung my oil kita m tlaga malapot n oil n mix liquid..
Kuya j ano laman ng kulay blue na tank
d rin lalabas ang oil kung hindi mo lalagyan ng liquid.. un ang di mo pinakita, gas lng ang kinarga mo.. kanina,
Sir musta po watching from england. Ang refrigerator namin hindi masyadong lumalamig pero ang frezer OK naman ano kaya ang problima?
Wow salamat, umabot sa England hehe. Barado yung daanan ng hangin pababa sa chiller compartment. Pwedeng yung damper sir ay di nagbukas dahil nagloko yung sensor. May cover kasi yan (damper) na nag open close kung tama na yung lamig. Now kung nagloko yung sensor na nag command ng open close nung damper yun ang dahilan na walang lamig ang chiller compartment.
@@KuyaJTechnology thank you and God bless
Sir additional info..ref timer pwede rin or evaporator heater at sensors problema kaya nagyelo evaporator at di makadaan hangin papunta sa ref compartment.2 klase ang timer electronic at mechanical..pag di nagstop ang compressor at di nagtransfer sa heater yung power mag yeyelo yung evaporator coil at magbabara ng yelo yung daanan ng hangin papunta sa babang compartment kaya di lalamig ang babang compartment
Kuya J pwede po b compressor air ang gamitin sa pag flushing kaysa refrigerant sayang kasi at baka mahal, baguhan lang po ako for DIY po
Pwede basta e wash out lang kaagad,wag lang ibabad ng matagal, may moisture kasi yung natural air
Sir pano po kung r600 na refrigerant ano po pwedeng pang flushing pag walang nitro
Sir,,,! Ask ko lang po kung ano sira ng ref kapag nag automatic ng andar at ayaw din lumamig,,?